Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Carfagna Iron Ridge
System Weight Total system weight 1 ,61 4.2 lbs Weight/attachment 25.2 lbs Racking weight 308.9 lbs Distributed weight 2.7 psf Load Assumptions Wind exposure B Wind speed 1 1 0 mph Ground snow load 20 psf Attachment spacing 4.0' Span Details XR1 00 - Portrait Zone Max span Max cantilever 1 7' 2' 1 0" 2 7' 2' 1 0" 3 7' 2' 1 0" Reaction Forces XR1 00 - Portrait Zone Down (lbs) Uplift (lbs) Lateral (lbs) 1 1 60 1 00 70 2 1 60 1 24 70 3 1 60 1 24 70 Project Details Name Mark Carfagna Date 1 0/1 8/201 9 Location 31 1 1 st Avenue Northwest, Carmel, IN, 46032 Total modules 32 Module Panasonic: VBHN340SA1 7 (40mm) Total watts 1 0,880 Dimensions 62.6" x 41 .46" x 1 .57" (1 590.0mm x 1 053.0mm x 40.0mm) Attachments 64 Roof Information Roof material Comp Shingle Building height 30 ft Roof attachment Flashfoot2 Roof slope 35 ° Attachment hardware Square Risk category II Last updated by Joel Walsman on 1 0/1 8/1 9 09:30 AM Page 1 of 7 Mark Carfag na (#560352) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 11/15/19 Mike Sheeks Roof Section 1 Definition Roof Section Weights Roof Section (all segments) 1 6 modules Total weight: 795.1 lbs Provided rail: 1 36' [8 x 1 7'] Portrait orientation Weight/attachment: 24.8 lbs Attachments: 32 Graphical entry Total Area: 295.1 sq ft Splices: 0 Distributed weight: 2.7 psf Clamps: 24 Diagram 1 3' 1 1 "21'Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 4 1 4' 1 " 1 ' None 34' [2 x 1 7'] 8 0 6 Row segment totals (x 4) → 1 36' [8 x 1 7'] 32 0 24 Roof Section 2 Definition Roof Section Weights Roof Section (all segments) 1 0 modules Total weight: 51 7.3 lbs Provided rail: 1 1 2' [8 x 1 4'] Portrait orientation Weight/attachment: 25.9 lbs Attachments: 20 Graphical entry Total Area: 1 83.8 sq ft Splices: 4 Distributed weight: 2.8 psf Clamps: 1 6 Diagram 1 7' 5"10' 6"Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 5 1 7' 7" 9" None 56' [4 x 1 4'] 1 0 2 8 Row segment totals (x 2) → 1 1 2' [8 x 1 4'] 20 4 1 6 Last updated by Joel Walsman on 1 0/1 8/1 9 09:30 AM Page 2 of 7 Mark Carfag na (#560352) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 11/15/19 Mike Sheeks Roof Section 3 Definition Roof Section Weights Roof Section (all segments) 6 modules Total weight: 302.1 lbs Provided rail: 56' [4 x 1 4'] Portrait orientation Weight/attachment: 25.2 lbs Attachments: 1 2 Graphical entry Total Area: 1 1 0.9 sq ft Splices: 0 Distributed weight: 2.7 psf Clamps: 8 Diagram 1 0' 5"10' 6"Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 3 1 0' 7" 1 ' 4" None 28' [2 x 1 4'] 6 0 4 Row segment totals (x 2) → 56' [4 x 1 4'] 1 2 0 8 Side View (portrait) 35° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Joel Walsman on 1 0/1 8/1 9 09:30 AM Page 3 of 7 Mark Carfag na (#560352) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 11/15/19 Mike Sheeks Front View (portrait) ATTACHMENT SPAN 4.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Splice Details XR1 00 SIDE-FACING SLOT INTERNAL SPLICE TOP-FACING SLOT Splice Connection INTERNAL SPLICE RAIL SELF-DRIVING SCREW Last updated by Joel Walsman on 1 0/1 8/1 9 09:30 AM Page 4 of 7 Mark Carfag na (#560352) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 11/15/19 Mike Sheeks Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULE FRAME UNIVERSAL FASTENING OBJECT PV MODULE FRAME RAIL CAMO CAMO End Clamp, Plan CAMO RAIL CAMO End Clamp, Front PV MODULE FRAME FlashFoot2 Detail Plan View 9” 1 2” 2 “3 1 6 Side View 1 “1 1 1 6 Perspective View Front View 1 “5 8 3 “5 16 “5 16 Last updated by Joel Walsman on 1 0/1 8/1 9 09:30 AM Page 5 of 7 Mark Carfag na (#560352) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 11/15/19 Mike Sheeks Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 1 0 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by Joel Walsman on 1 0/1 8/1 9 09:30 AM Page 6 of 7 Mark Carfag na (#560352) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 11/15/19 Mike Sheeks Bill of Materials Part Spares Total Qty Rails & Splices XR-1 00-204B XR1 00, Rail 204" (17 Feet) Black 0 8 XR-1 00-1 68B XR1 00, Rail 1 68" (14 Feet) Black 0 1 2 XR-1 00-SPLC-M1 XR1 00 Bonded Splice (Incl. Self-tapping Screws) 0 4 Clamps & Grounding UFO-CL-01 -B1 Universal Module Clamp, Black 0 48 CAMO-01 -M1 Hidden End Cam (universal clamp) 0 32 XR-LUG-03-A1 Grounding Lug, Low Profile 0 8 Attachments FF2-01 -B1 FlashFoot2, Black 0 64 BHW-SQ-02-A1 Square-Bolt Bonding Hardware 0 64 Accessories 29-4000-077 Wire Clips, Molded PVC Black, Polybag 20 0 4 XR-1 00-CAP Kit, End Cap XR100 (10 sets per bag) 0 2 BHW-MI-01 -A1 Microinverter Bonding Hardware, T-Bolt 0 32 Last updated by Joel Walsman on 1 0/1 8/1 9 09:30 AM Page 7 of 7 Mark Carfag na (#560352) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 11/15/19 Mike Sheeks