Loading...
HomeMy WebLinkAboutA000.1\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION ARCHED SOLDIER COURSE, PER SPEC 18"x72" PANEL SHUTTERS, PER SPEC ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC 10" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK VENEER, PER SPECSTONE SILL, PER SPEC STONE VENEER, PER SPEC 1214 1214 SHAKE SIDING, PER SPECARCHED STONE SOLDIER COURSE, PER SPEC 1214 1214 1214 1214 1214 BRICK SOLDIER COURSE, PER SPEC 4" FRIEZE, PER SPEC BRICK SOLDIER JACK ARCH, PER SPECBOX BAY w/ 8" TRIM BOARDS, PER SPECHARDIE PANEL (SMOOTH), PER SPEC \A1;2'-7" SCALE:FRONT ELEVATION1/4" = 1'-0"- 8:12 8:12 8:12 8:12 8:12 \A1;10'-1{\H0.75x;\S1#8;}"\A1;PLATE HEIGHT\A1;9'-2{\H0.75x;\S1#2;}"\A1;PLATE HEIGHT \A1;8'-0" \A1;13'-1{\H0.75x;\S1#8;}"\A1;PLATE HEIGHT \A1;3'-6"\A1;MIN. \A1;R7'-1" \A1;2'-1" \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. \A1;5'-1{\H0.750000x;\S3#4;}" \A1;24'-0" \A1;10'-0" \pxi-4,l4,ql,t3;POT VENTS \A1;8'-0" "A"3352ROOF AREA:SQ. FT. 14:12 8:12 8:12 SCALE:ROOF PLAN1/8" = 1'-0"- 8:128:12 8:12 8:12 8:12 8:12 8:12 8:128:12 14:12 14:12 14:12 14:1214:12 14:12 14:12 14:12 128 BRICK VENEER, PER SPEC 8" FASCIA BOARD, PER SPEC ROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;3'-6"\A1;MIN. 128 128 128 128 STONE SOLDIER COURSE, PER SPEC \A1;3'-6" SCALE:LEFT ELEVATION1/8" = 1'-0"- ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC BRICK VENEER, PER SPEC TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" 128 STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC4" FRIEZE, PER SPEC 10" FRIEZE, PER SPEC \A1;3'-6"\A1;MIN. 128 128 128 128 128 128 SCALE:RIGHT ELEVATION1/8" = 1'-0"- TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" BRICK VENEER, PER SPEC 8" FASCIA, PER SPECROOF SHINGLES, PER SPEC 12141214 4"TRIM, PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- \A1;3'-6" \A1;11'-1{\H0.75x;\S1#8;}"\A1;PLATE HEIGHT ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3352 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.47 5.59 5.51 49.16 13 0 AT EAVE 6.70 5.59 5.69 50.84 0 82.00 TOTAL (MIN)11.17 11.17 11.20 100.00 3 HIGH - RIDGE VENT 4.47 5.59 5.52 49.23 3 0 34.00 AT EAVE 6.70 5.59 5.69 50.77 0 82.00 TOTAL (MIN)11.17 11.17 11.22 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE PLOTTED: October 14, 2019 / Annie Lee / 2600-IN-MONACO-EC01.DWG A3-EC01 1FB.3Euro Country2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette3/30/2015 GARAGE RIGHT 2600-Monaco 1837.0000 LOT 08 10/14/2019 No Window Well Here. 11/18/19 William Hohlt