HomeMy WebLinkAboutA01-01 - ARCHITECTURAL SITE PLANRELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�7�DwadNOA.tiL
�•/ \\ ST4 N88045'22'E-45184'
_ _ _rL _ _ _ — �—
•
I
I
•
I
I
1
I
I
•
I � I
I � I
I � •
I I
I 0 •
I
I 0 � b •
I
O
I I •
I I
0
0
I � 1
I 0
I DI
I 0
ST4 1I
_ �e
IEE --7 — _ _9i _
1 _I ZL
ST3, H C f �l L ^_I - - -_ -_ - - -
q
LLH •
• I
A01-03 1
J 4 4 4 4 4 4 4 STd
4 T2 N89'i6'40'W-44453'
1 ARCHITECTURAL SITE PLAN
1'= 20' 0"
ARCHITECTURAL SITE
GENERAL NOTES
1. ARCHITECTURAL SITE PLAN IS ISSUED FOR REFERENCE ONLY.
2. RE: CIVIL DRAWINGS FOR ALL SITE CONSTRUCTION INFORMATION
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
- SITE GEOMETRY AND DIMENSIONAL CONTROL
- SITE UTI LITI ES
- SITE GRADI NG AND DRAINAGE
- ASPHALTICONCRETE PAVING DETAILS
- PAVING MARKERS
- CONCRETE SIDEWALK, CURB, AND GUTTER DETAILS
- PARKING WHEEL STOPS
- TRAFFIC SIGNAGE
- PAVING STRIPING AND CURB MARKINGS
- TYPICAL HANDICAP SIGNAGEISPACES
3. RE: ELECTRICAL DRAWINGS FOR SITE INFORMATION INCLUDING, BUT NOT
LIMITED TO THE FOLLOWING:
- SITE LIGHT STANDARD LOCATIONS AND SIZES
- ELECTRICAL SLEEVING LOCATIONS AND SIZES
- TELEPHONE AND CABLE T.V. PULL BOX LOCATIONS
- ELECTRICAL MANHOLE LOCATIONS AND DETAILS
- PULL BOX LOCATIONS AND SIZES FOR VARIOUS SITE LIGHTING
ELEMENTS
- EXTERIOR BUILDING ILLUMINATION AND UTILITY COORDINATION
4. REFERENCE SPECIFICATIONS FOR SITE SIGNAGE PACKAGE INFORMATION.
5. REFERENCE LANDSCAPE DRAWINGS FOR:
- LANDSCAPE PLANTING AND DETAILS
- SODDING AND SEEDING
- LANDSCAPE BED DRAINAGE
- HARDSCAPE LAYOUT AND DETAILS(SPECIALTY PAVING)
6. REFERENCE IRRIGATION IN LANDSCAPE DRAWINGS FOR:
- HEAD AND VALVE LOCATIONS AND SIZES
- IRRIGATION SLEEVING LOCATIONS AND SIZES
- IRRIGATION SYSTEM CONTROLLER LOCATION
- DETAILS AND SPECIFICATIONS
7, DO NOT SCALE THE DRAWINGS. IN CASE OF DISCREPANCIES, OR IF
DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT
PRIOR TO PROCEEDING WITH THE WORK.
8. "TOP OF SLAB' ELEVATION AS REFERENCED THROUGHOUT THE CONTRACT
DOCUMENTS DOES NOT NECESSARILY EQUATE TO "FINISH FLOOR
ELEVATION."
"TOP OF SLAB' AS REFERENCED HEREINAFTER IS DEFINED AS THE FINAL
POURED CONCRETE SUBFLOOR ELEVATION
PRIOR TO APPLICATION OF SCHEDULED FLOOR FINISHES.
"FINISH FLOOR ELEVATION" IS MEASURED TO TOP OF SCHEDULED FLOOR
FINISH MATERIAL.
9. MAINTAIN EXISTING ACCESS TO ALL SITE AND PARKING LOT ENTRANCES,
AND DO NOT BLOCK ACCESS TO DRIVES AND COVERED DROP OFF AREAS.
SITE WORK AND STAGING THAT AFFECT THE AREAS ADJACENT TO
BUILDING ENTRANCES WI LL REQUI RE A WRITTEN COORDI NATI ON PLAN
SUBMITTED TO AND APPROVED BY THE FACILITY.
10. INFORM OWNER PRIOR TO ANY SITE DEMOLITION AND SCHEDULE SUCH
DEMOLITION AS NOT TO INTERFERE WITH THE OWNER'S OPERATIONS AS
OUTLINED IN AN AGREED PHASING PLAN AND SCHEDULE.
PARKING SPACES
REQUIRED
CITY OF CARMEL REQUIRED SPACES'.
1 SPACE PER BED 40 BEDS = 40 SPACES
1 SPACE FOR EVERY 2 EMPLOYEES AT MAX SHIFT 57 EMPLOYEES =29 SPACES
TOTAL=69 SPACES
ACCESSIBLE SPACES REQUIRED:
ACCESSIBLE VISITOR/ PATIENT SPACES(20% OF104)=21SPACES
ACCESSIBLE EMPLOYEE SPACES 3612 SPACES FOR26TO 50SPACESI=2SPACES
TOTAL ACESSIBLE SPACES REQUIRED = 23
VAN ACCESSIBLE SPACES REQUIRED:
1 PER60F23=4
TOTAL 104 SPACES (INCL. 30 ACCESSIBLE)
PARKING SPACES
PROVIDED
TOTAL SPACES PROVIDED.
VISITORIPATIENT 68SPACES
EMPLOYEE SPACES 36 SPACES
TOTALSPACES 104 SPACES PROVIDED
OF WHICH:
ACCESSIBLE VISITOR I PATIENT PROVIDED =21
ACCESSIBLE EMPLOYEE PROVIDED =2
TOTAL ACCESSIBLE SPACES PROVIDED 23 SPACES PROVIDED
OF WHICH:
VAN ACCESSIBLE VISITOR I PATIENT PROVIDED =2
VAN ACCESSIBLE EMPLOYEE PROVIDED =1
TOTAL ACCESSIBLE SPACES PROVIDED 3 SPACES PROVIDED
2 OF 12 DESIGNATED FORVAN SPACE
NOTES:
9
1, PER OBC LOSS, 1 IN EVERY 6 ACCESSIBLE SPACES SHALL BE SERVED BY A 96
INCH WIDE ACCESS AISLE AND SHALL BE DESIGNATED AS VAN ACCESSIBLE'. SO
FOR THIS PROJECT, SIBLE SPACES ARE REQUIRED
ARCHITECTURAL SITE
PLAN LEGEND
NEW CONCRETE SIDEWALK OR PAVING
® NEW HOSPITAL FOOTPRINT
NEWASPHALT PAVING
NEWLY SODDED OR LANDSCAPED AREA
PROPERTY LINE
EASEMENT, BUILDING SETBACK 8 R.O.W.
12 NEWPARKING SPACE COUNT
—FL —FL —FL —FL —FL —FL —FL —FL— FIRE LANE PATH
b b REQUIRED ACCESSIBLE PATH
Q SECURITY CAMERA
ARCHITECTURAL SITE PLAN
NOTES BY NUMBER
O
<<< Indicates Sheet Keynote on Plan
ST3
ILLUMINATED MONUMENTAL SIGN REF :2 a 3IA-01-03
SITE LIGHTING FIXTURE REF. ELECTRICAL
CHAIN LINKED FENCE
ST4
ST8
ST14
EMERGENCY GENERATOR ENCLOSURE
DUMPSTER ENCLOSURE
METAL PIPE BOLLARD PAINTED
ST15
ST16
ST18
TRASH CAN
ST21
HANDICAP ACCESSIBLE PARKING SIGN
Perkins&Will
2218 BRYAN STREET, SUITE 200
DALLAS, TX 75201
t 214 2B3 8756
www.perkinswill.com
CONSULTANTS
CIVIL
AMERICAN STRUCTUREPOINT
7260 SHADELAND STATION
I NDIANAPOLIS, IN 46256
STRUCTURAL
STANTEC
6080 TENNYSON PARKWAY, SUITE 200
PIANO, TX 75024-6003
MEP
SWASSOCIATES
1700 PACIFIC AVE, SUITE 2100
DALLAS, TX 75201
LANDSCAPING
AMERICAN STRUCTUREPOINT INC.
7260 SHADELAND STATION
I NDIANAPOLIS, IN 462%
FOOD SERVICE
BOSMA DESIGN SOLUTIONS, INC.
2201 LONG PRAIRIE RD. SUITE 107-727
FLOWER MOUND, TX 75022
CONTRACTOR
MEYER NAJEM CONSTRUCTION, LLC
11787 LANTERN ROAD, SUITE 100
FISHERS, IN 46038
08/15/2019 PROJECT
FACILITY:
o INDIANAPOLIS
REHABILITATION
HOSPITAL
1260 CITY CENTER DRIVE
zz CARMEL, INDIANA46032
U
DEVELOPER:
Cn
o WB DEVELOPMENT
o PARTNERS
LL. 4441 WAIRPORT
LU FREEWAY, SUITE 330
cn IRVING, TX 75062
Cn
KEYPLAN
ISSUE CHART
IMARKI ISSUE
DATE
JOB NUMBER
147396.000
DRAWN
SH
CHECKED
SA
APPROVED
CG
TITLE
ARCHITECTURAL
SITE
PLAN
SHEET NUMBER
A01-01
DATE: -I -I / I W I `)