Loading...
HomeMy WebLinkAboutA01-01 - ARCHITECTURAL SITE PLANRELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �7�DwadNOA.tiL �•/ \\ ST4 N88045'22'E-45184' _ _ _rL _ _ _ — �— • I I • I I 1 I I • I � I I � I I � • I I I 0 • I I 0 � b • I O I I • I I 0 0 I � 1 I 0 I DI I 0 ST4 1I _ �e IEE --7 — _ _9i _ 1 _I ZL ST3, H C f �l L ^_I - - -_ -_ - - - q LLH • • I A01-03 1 J 4 4 4 4 4 4 4 STd 4 T2 N89'i6'40'W-44453' 1 ARCHITECTURAL SITE PLAN 1'= 20' 0" ARCHITECTURAL SITE GENERAL NOTES 1. ARCHITECTURAL SITE PLAN IS ISSUED FOR REFERENCE ONLY. 2. RE: CIVIL DRAWINGS FOR ALL SITE CONSTRUCTION INFORMATION INCLUDING BUT NOT LIMITED TO THE FOLLOWING: - SITE GEOMETRY AND DIMENSIONAL CONTROL - SITE UTI LITI ES - SITE GRADI NG AND DRAINAGE - ASPHALTICONCRETE PAVING DETAILS - PAVING MARKERS - CONCRETE SIDEWALK, CURB, AND GUTTER DETAILS - PARKING WHEEL STOPS - TRAFFIC SIGNAGE - PAVING STRIPING AND CURB MARKINGS - TYPICAL HANDICAP SIGNAGEISPACES 3. RE: ELECTRICAL DRAWINGS FOR SITE INFORMATION INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: - SITE LIGHT STANDARD LOCATIONS AND SIZES - ELECTRICAL SLEEVING LOCATIONS AND SIZES - TELEPHONE AND CABLE T.V. PULL BOX LOCATIONS - ELECTRICAL MANHOLE LOCATIONS AND DETAILS - PULL BOX LOCATIONS AND SIZES FOR VARIOUS SITE LIGHTING ELEMENTS - EXTERIOR BUILDING ILLUMINATION AND UTILITY COORDINATION 4. REFERENCE SPECIFICATIONS FOR SITE SIGNAGE PACKAGE INFORMATION. 5. REFERENCE LANDSCAPE DRAWINGS FOR: - LANDSCAPE PLANTING AND DETAILS - SODDING AND SEEDING - LANDSCAPE BED DRAINAGE - HARDSCAPE LAYOUT AND DETAILS(SPECIALTY PAVING) 6. REFERENCE IRRIGATION IN LANDSCAPE DRAWINGS FOR: - HEAD AND VALVE LOCATIONS AND SIZES - IRRIGATION SLEEVING LOCATIONS AND SIZES - IRRIGATION SYSTEM CONTROLLER LOCATION - DETAILS AND SPECIFICATIONS 7, DO NOT SCALE THE DRAWINGS. IN CASE OF DISCREPANCIES, OR IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. 8. "TOP OF SLAB' ELEVATION AS REFERENCED THROUGHOUT THE CONTRACT DOCUMENTS DOES NOT NECESSARILY EQUATE TO "FINISH FLOOR ELEVATION." "TOP OF SLAB' AS REFERENCED HEREINAFTER IS DEFINED AS THE FINAL POURED CONCRETE SUBFLOOR ELEVATION PRIOR TO APPLICATION OF SCHEDULED FLOOR FINISHES. "FINISH FLOOR ELEVATION" IS MEASURED TO TOP OF SCHEDULED FLOOR FINISH MATERIAL. 9. MAINTAIN EXISTING ACCESS TO ALL SITE AND PARKING LOT ENTRANCES, AND DO NOT BLOCK ACCESS TO DRIVES AND COVERED DROP OFF AREAS. SITE WORK AND STAGING THAT AFFECT THE AREAS ADJACENT TO BUILDING ENTRANCES WI LL REQUI RE A WRITTEN COORDI NATI ON PLAN SUBMITTED TO AND APPROVED BY THE FACILITY. 10. INFORM OWNER PRIOR TO ANY SITE DEMOLITION AND SCHEDULE SUCH DEMOLITION AS NOT TO INTERFERE WITH THE OWNER'S OPERATIONS AS OUTLINED IN AN AGREED PHASING PLAN AND SCHEDULE. PARKING SPACES REQUIRED CITY OF CARMEL REQUIRED SPACES'. 1 SPACE PER BED 40 BEDS = 40 SPACES 1 SPACE FOR EVERY 2 EMPLOYEES AT MAX SHIFT 57 EMPLOYEES =29 SPACES TOTAL=69 SPACES ACCESSIBLE SPACES REQUIRED: ACCESSIBLE VISITOR/ PATIENT SPACES(20% OF104)=21SPACES ACCESSIBLE EMPLOYEE SPACES 3612 SPACES FOR26TO 50SPACESI=2SPACES TOTAL ACESSIBLE SPACES REQUIRED = 23 VAN ACCESSIBLE SPACES REQUIRED: 1 PER60F23=4 TOTAL 104 SPACES (INCL. 30 ACCESSIBLE) PARKING SPACES PROVIDED TOTAL SPACES PROVIDED. VISITORIPATIENT 68SPACES EMPLOYEE SPACES 36 SPACES TOTALSPACES 104 SPACES PROVIDED OF WHICH: ACCESSIBLE VISITOR I PATIENT PROVIDED =21 ACCESSIBLE EMPLOYEE PROVIDED =2 TOTAL ACCESSIBLE SPACES PROVIDED 23 SPACES PROVIDED OF WHICH: VAN ACCESSIBLE VISITOR I PATIENT PROVIDED =2 VAN ACCESSIBLE EMPLOYEE PROVIDED =1 TOTAL ACCESSIBLE SPACES PROVIDED 3 SPACES PROVIDED 2 OF 12 DESIGNATED FORVAN SPACE NOTES: 9 1, PER OBC LOSS, 1 IN EVERY 6 ACCESSIBLE SPACES SHALL BE SERVED BY A 96 INCH WIDE ACCESS AISLE AND SHALL BE DESIGNATED AS VAN ACCESSIBLE'. SO FOR THIS PROJECT, SIBLE SPACES ARE REQUIRED ARCHITECTURAL SITE PLAN LEGEND NEW CONCRETE SIDEWALK OR PAVING ® NEW HOSPITAL FOOTPRINT NEWASPHALT PAVING NEWLY SODDED OR LANDSCAPED AREA PROPERTY LINE EASEMENT, BUILDING SETBACK 8 R.O.W. 12 NEWPARKING SPACE COUNT —FL —FL —FL —FL —FL —FL —FL —FL— FIRE LANE PATH b b REQUIRED ACCESSIBLE PATH Q SECURITY CAMERA ARCHITECTURAL SITE PLAN NOTES BY NUMBER O <<< Indicates Sheet Keynote on Plan ST3 ILLUMINATED MONUMENTAL SIGN REF :2 a 3IA-01-03 SITE LIGHTING FIXTURE REF. ELECTRICAL CHAIN LINKED FENCE ST4 ST8 ST14 EMERGENCY GENERATOR ENCLOSURE DUMPSTER ENCLOSURE METAL PIPE BOLLARD PAINTED ST15 ST16 ST18 TRASH CAN ST21 HANDICAP ACCESSIBLE PARKING SIGN Perkins&Will 2218 BRYAN STREET, SUITE 200 DALLAS, TX 75201 t 214 2B3 8756 www.perkinswill.com CONSULTANTS CIVIL AMERICAN STRUCTUREPOINT 7260 SHADELAND STATION I NDIANAPOLIS, IN 46256 STRUCTURAL STANTEC 6080 TENNYSON PARKWAY, SUITE 200 PIANO, TX 75024-6003 MEP SWASSOCIATES 1700 PACIFIC AVE, SUITE 2100 DALLAS, TX 75201 LANDSCAPING AMERICAN STRUCTUREPOINT INC. 7260 SHADELAND STATION I NDIANAPOLIS, IN 462% FOOD SERVICE BOSMA DESIGN SOLUTIONS, INC. 2201 LONG PRAIRIE RD. SUITE 107-727 FLOWER MOUND, TX 75022 CONTRACTOR MEYER NAJEM CONSTRUCTION, LLC 11787 LANTERN ROAD, SUITE 100 FISHERS, IN 46038 08/15/2019 PROJECT FACILITY: o INDIANAPOLIS REHABILITATION HOSPITAL 1260 CITY CENTER DRIVE zz CARMEL, INDIANA46032 U DEVELOPER: Cn o WB DEVELOPMENT o PARTNERS LL. 4441 WAIRPORT LU FREEWAY, SUITE 330 cn IRVING, TX 75062 Cn KEYPLAN ISSUE CHART IMARKI ISSUE DATE JOB NUMBER 147396.000 DRAWN SH CHECKED SA APPROVED CG TITLE ARCHITECTURAL SITE PLAN SHEET NUMBER A01-01 DATE: -I -I / I W I `)