HomeMy WebLinkAboutA12-01A - REFLECTED CEILING PLAN -LEVEL 01 -AREA AMA
SE
1 1.1 2 2.4 O 3.7 4 4.3 5 5.3 6 6.1 7 7.8 8 9 9.2
ADL.
A36oz
I I I I I I I I I I I I I I I I
I I I I I I I I I I I I I I I I
I I I I I I I I I I I I I I I I
REFLECTED CEILING PLAN - LEVEL 01 -
AREA A
\ ' / 118w = 1'-Ow
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
�N;T�v3lDw�,D>,S>Z
RCP PLAN GENERAL NOTES
1. THE CONTRACTOR SHALL COMPARE THIS REFLECTED CEILING PLAN WITH
ELECTRICAL LIGHTING PLANS, MECHANICAL SUPPLY, RETURN, AND
EXHAUSTPLANS, THE CONTRACTOR SHALL REPORT ANY OMISSIONS OR
INCONSISTENCIES TO THE ARCHITECT,
2. SEE ELECTRICAL DRAWINGS FOR THE LOCATIONS OF CEILING MOUNTED
SMOKE DETECTORS, SPEAKERS, NURSE CALL DOME LIGHTS, EXIT SIGNAGE,
FIRE ALARM DEVICES, WALL MOUNTED EXIT LIGHTS, ETC.
3, FOR FURTHER DIMENSIONS SEE LARGE SCALE PLANS,SECTIONS,
ELEVATIONS, AND DETAILS.
4. COORDINATE GYPSUM BOARD FURR DOWN HEIGHTS WITH FULL HEIGHT
CABINETS AND INTERIOR ELEVATIONS (A-45 SERIES)
5, SPRINKLER HEAD LOCATIONS ARE NOT SHOWN ON ARCHITECTURAL
REFLECTED CEILING PLANS. (BUILDING IS TO BE 'FULLY SPRINKLERED-) PER
NFPA 13 AND OWNER'S INSURANCE COMPANY'S REQUIREMENTS.
6. 18' MINIMUM VERTICAL CLEARANCE SHALL BE MAINTAINED BETWEEN THE
BOTTOM OF EXTENDED SPRINKLER HEADS AND THE TOP OF ANY FILES,
SHELVING, LOCKERS, ETC.
7. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF TYPE
SPECIFIED ARE INSTALLED IN NON -ACCESSIBLE TYPE CEILINGS WHERE
SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING, OR ELECTRICAL
ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE THE FIRE RATED TYPE
EQUAL TO THE RATING OF THE CEILING IN WHICH THEY OCCUR.
8. RELOCATE SUPPLY DRAIN AND VENT PIPES TO MAINTAIN SCHEDULED
CEILING HEIGHTS, COORDINATE RELOCATIONS WITH MEP ENGINEERS,
9. REFERTOA-64-01 INTERIOR FINISH SCHEDULE FOR VP ROLLER SHADE
TYPES.
10. ALL CEILINGS LOCATED AT 9'-0'AFF UNLESS OTHERWISE NOTED.
RCP LEGEND
SUSPENDED 2'X 2'ACOUSTICAL
CEILING SYSTEM
SUSPENDED 2'X 4'ACOUSTICAL
CEILING SYSTEM
RECESSED LED LIGHT FIXTURE
® SUPPLY AIR GRILLE
REFERTO MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION
® RETURN AIR GRILLE
REFERTO MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION
EXHAUST AIR GRILLE
® REFERTO MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION
® SUPPLY STRIP DIFFUSER RE: MECHANICAL
C.J. CONTROL JOINT
SIM
CEILING DETAIL ISECTION TAG
A-XXX
AFF CEILING HEIGHT DESIGNATION PER AREA. WHERE
49'-V
NO HEIGHT IS DESIGNATED, ASSUME 9'-0P
o CONTINUOUS RECESSED LINEAR FIXTURE, LENGTH VARIES
LINEAR'FIN' LIGHT FIXTURE 0'
LINEAR GRID MOUNTED LIGHT FIXTURE, LENGTH VARIES
® GYPSUM BOARD FURR DOWN OVER WALL CABINET OR LOCKER
(REF 011A51-01 TYP)
Ho WALL MOUNTED LIGHT FIXTURE
+ PENDANT
���❑
RECESSED SQUARE LIGHT FIXTURE
0 RECESSED CAN LIGHT FIXTURE
® SHOWER DOME LIGHT (BY SHOWER MANUFACTURER)
WALL MOUNTED LIGHT FIXTURE
GYPSUM BOARD CEILING
SUSPENDED CEMENT PLASTER SOFFIT
WOOD -LOOK LAMINATE
ES EXPOSED STRUCTURE
WOOD GRAIN DIRECTION
RCP PLAN GENERAL NOTES
Q
<<< Indicates Sheet Keynote on Plan
R2
RECESSED MOTORIZED ROLLER SHADE TYPE WT2'
R4
CENTER LIGHT I N ROOM I N BOTH DIRECTIONS
R5
ROOF HATCH
R6
CENTER LIGHT ABOVE SINK
R7
SURFACE MOUNTED MANUAL ROLLER SHADE TYPE WTY, REF OBIA51-01
RB
PAINT GYP CEILI NO ACCENT COLOR'P3'
R10
61N ALUMI NUM PERI METER EDGE TRIM
R15
CENTERLI NE OF BED BELOW
R16
CONTINUOUS LINEAR SLOT DIFFUSER, REF MEP
R21
IBOTTOM UP MOTORIZED ROLLER SHADE'WT4'
Perkins&Will
2218 BRYAN STREET, SUITE 200
DALLAS, TX 75201
t 214 283 8756
www. perkinswilLcom
CONSULTANTS
CIVIL
AMERICAN STRUCTUREPOINT
7260 SHADELAND STATION
I NDIANAPOLIS, IN 46256
STRUCTURAL
STANTEC
6080 TENNYSON PARKWAY, SUITE 200
PIANO, TX 75024-6003
MEP
SWASSOCIATES
1 MID PACIFIC AVE, SUITE 21 TO
DALLAS, TX 75201
LANDSCAPING
AMERICAN STRUCTUREPOINT INC.
7260 SHADELAND STATION
I NOIANAPOLIS, IN 462%
FOODSERVICE
BOSMA DESIGN SOLUTIONS, INC.
2201 LONG PRAIRIE RD. SUITE 107-T27
FLOWER MOUND, TX 75022
CONTRACTOR
MEYER NAJEM CONSTRUCTION, LLC
11787 LANTERN ROAD, SUITE 100
FISHERS, IN 46038
08/15/2019 PROJECT
FACILITY:
o
INDIANAPOLIS
REHABILITATION
HOSPITAL
1260 CITY CENTER DRIVE
zz
CARMEL, INDIANA46032
H
v
DEVELOPER:
N
0
WB DEVELOPMENT
PARTNERS
o
LL
4441 WAIRPORT
LU
FREEWAY, SUITE 330
N
IRVING, TX 75062
—
KEYPLAN
ISSUE CHART
IMARKI
ISSUE
DATE
JOB NUMBER
147396.000
DRAWN
SH
CHECKED
SA
APPROVED
CG
TITLE
REFLECTED CEILING
PLAN - LEVEL 01 -
AREA A
SHEETNUMBER
Al 2-01 A
DATE: 1 1 / I `,1/ I `,1