Loading...
HomeMy WebLinkAboutA61-50 - INTERIOR PARTITION DETAILSPerkins&Will RELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes City of Carmel �I `��¢m�' lamn�Ml1 � onrE: 11 /19/19 LWEOFSTRUCTURE MWERAL RBER Nsu�nnoN — �OUBLETRACKSYSTEM- ����1� � � STEELSTUDBRACING ♦ @6'0"OC .. �. --- CONTINUOUS HORIZONTALSTEEL I STU� REQUIRE� WHEN GYP 8� .-� � ooEs Nor E�ENo ro siaucruaE � � ��� SEALAROUN�BRACEATRATE� Q � PARTITIONS.WHENSTC i o RE�UIREDANDWHENGYPBD c� r ""���: �-� - CONTINUESUPTOSTRUCTURE w N x > � m _ ....-- srEE� (sruo s¢E aEa � � �:_� . PnaTinoN cHnaT� x o � � � < �- scnEou�EoceuNc � -�-�-����— ncousncn� anns iN sruo CAVITV TO STRUCTURE WHEN STC RWUIRED -� GYPBDEXTENDSTOfi"MIN \ ROOR ABpVEFINISHE�CEILING(UNLESS RATE� OR ACAUSTICAL NOTES�. PARTITIONJ 1. WHERE STC IS NOTA REQUIREMENT. CONTRACTOR HAS THE OPTION TOINCREASE GAGE AND /OR DECREASE STUD SPACING PER STUD MFR ALLOWANCES. PARTITION BRACING SECTION ���2•=���• WHENPARTITIONEXCEEDSMAXIMUMHEIGHTALLOWEDBVSTDMFR cmm m 2F LINE OF STRUCTURE � � ACOUSTICALSEALANT- 1-5/8"GYPBD 3 5/8", 0.018" TKK (25 GAJ STLSTUDS 312'ACOUSTICALBATfS iil`�al�lr� 1�5I8"GYPBD 06I8", OAaB"THK— (25 GA) STL STU�S 3"ACOUSTICAL BATTS ACOUSTICAL SEALANT i�l%�alHlr� `�"� ����' ��-�'—DONOTATTACHGVPBDTO i - DEFLECTIONPLATE ; - �� L_�=-- `DEFLECTIONPLATEWITH9"LONG - OUTERLEG$RE'.12/Afii-50 � � .. �: � ....'.- 2-5I8"GYPBD ) � � �% � 35/8". 0.018"TKK(25GAJ � � STLSTUDS � ._ ... ...............'..-31/2"ACOUSTICALBATTS .0' -1"AIR SPACE rS4 (STC 64) HEAD @ PARTITION'U' c,o,o.os-,F , DERECTIONCLIPS �L :0-1"AIR SPACE // SOUNDATTENUATION -" _ INSUlATIONWHERE �"�� SCHEDULED - NONSTRUCTURAL -.. _. ! � METALSTUDS —2�5I8"GYPBD 06I8".OAaB"TKK�26 GA)STLSTU�S ACOUSTICALSEALANT - FLOOR PARTITION'U' C1010.02-tE srEE� sruo sizEo PER . PPRTITIONCHNRT,0.018"TKK(25 GA) WHEN STC RATED 2lAYERS OF 5I8" GYP B� (EA SI�E) � PERPARTITIONNPE souNonrrENunnoNenrr . (THICKNESSPERPARTITIONTVPE) STEELSTUDRUNNER � REXIBLEACOUSTICALSEALANT F�ooR ACOUSTICAL PARTITION FLOOR �f�%��1� @ FLOOR OF 2-HR RATED PARTITION OF NON-RATED PARITION WITH AN STC REQUIREMENT cmmoa�c '- STEELSTUD(SIZEDPER PARTITONTYP� 0.018" TKK (25 GA) WHEN 3TC � � RATINGRWUIRE� GYPSUM BOAR� . — ACOUSTICAL SEAIANT . .— — . — BATTINSUlATION doiNr REWFORCEMENT ACOUSTICAL SEAIANT STEELSTUD --. �(SIZE�PER PARTITON TVPE) OAtB" THK (25 GA) WHEN STC RATING RWUIRED FlBERGLASSPACKING � (9fl�6fl DENSITY) CTION CONTROL JOINT PARTITION PLAN DETAILS 1 112" = 1,-0" iir`�s���u PnRririoN iNrERSEcrioNs nNo cvP coNrRo� doiNrs ciaia.as-ie : WITH MMERAL L OR GLASS FlBER 1STICALSEALANT 3ACKERROD VE CAST-IN-PLACE AT CONCRETE WALL JTED IN PLACE AT CMU WALL PARTITION-WALL IMERSECTION .,1 � �'. `�.. � ACOUSTICALSEALANT STEEL STUD (SIZED PER PARTITONTYP� 0.018"TKK(25 GA) WHEN 3TC RATING REQUIRED BATTINSUlATION GYPSUM BOARD ACOUSTICALSEALANT BATT WSULATION SEAL VOIDS FROM OUTSIDE AND COVER 80% WITH 1B" MIN SOUN� BATTS CUT GVP BD TO PLLOW 1/4" MIN OVERLAP 8Y FACE PLATE SCHE�ULE� PARTITION A MIN OF 1 STU� BETWEEN BOXES ♦ z ♦ i�r`�s���u REXIBLE CONDUIT LOWRY'SBOXPA� i'---°'1� ,.• - �- CAULKALLVOIDSBEIWEEN � GYPBDANDBOX NOTES. 1. 1P' MINIMUM UNLESS NOTE� OTHERWISE IN PARTITION CHART. @ BACK BO% INSTALlATION �ETAIL @ NON-FlRE RATE� PARTITION C1010.02-0A @ PIPE PENETRATION THRU CONCRETE OR CMU C1010]03D If�%��1� ^� � �� � GVPSUM BOARD T I R: —_ �........_ _1 .. _ � .I —._....�.. .,: � ACOUSTICAL __ 1.` SEALANT .-" �naouNo . �������--� PERIMETERI LINE OF STRUCTURE , GVP B� EXTEN�S TO 6" I ABOVE FINISHE� CEILING SLIP TRACK WITH 1" EXPANSIONATSTRUCTURE. RE�1?fA6250 SOUN� ATfENUATION BATTS WHERE LOCATE� ON RERECTE� CEILING PLAN � �-'�1�--��'� —SCHEDULEDCEILING STEELSTUDS y (PER PARTITIONTYPE) - SOUNDATTENUATIONBATfS 0.018" TKK (25 GA) (THICKNESS PER PARTITION TYPE) WHEN STC E%TEND FROM FLOOR TO RATINGREQUIRE�� � STRUCTUREABOVE @ NOPFRATED W/ GVP BD TO B"ABOVE CEILING fITION HEAD SECTION °,°,°'028 �ir`�s���u FlRERESISTIVE JOINT SYSTEM S/8"GVPBDEACHSIDE . SHEETMETAL ENCLOSURE SOUN�ATTENUA BATfS STEELSTUDS(PE PARTITION TYPE) 0.018" TKK (25 GA WHEN STC RATINe aeouiaeo METALCLOSUREWHERE REQUIRE� FOR STU� SUPPORT LINE OF STRUCTURE -� DEFLECTION SPACE. RE�. 11fA62fi0 �� DEFLECTIONTRACK il � F a w ' � ��'^l- w � �`—CEILING RUNNER 1"MAXAIRSPACE p � 1P2"MINAIRSPACE � o" _ STEEL STUDS (PER PARTITION TYPE) �������— SOUND ATTENUATION BATTS (THICKNESS PER PARTITION NPE) E%TEN� FROM FLOOR TOSTRUCTUREABOVE NOTES 1. CONTRACTORTOCOMPLVWITH�ETAILSHOWNORUSEPROPRIETARVSVSTEMAS�ESCRIBE�INTHESPECIRCATIONS. 2. U419-1-HRRATEDSTUDSTOBECUT3/B"T03/4"LESSTHANASSEMBLVHEIGHT. ��r`�s���u CMU PPCK WITH FlBERGLPSS INSULATI ON (9X TO 6B oeNsirh ACOUSTICALSEALANT SHEET METAL ENCLOSURE @ �UCT PENETRATION THRU NON�FIRE RATE� PARTITION rnnr is souNo ranNSMissioN cwssiFiEo cima.aa-sc C10IDA94K c�� �< WALL TO STRUCTURE U485 Q-HR), U4H (2-HRJ, U419 Q-HRJ C1010.10.2A 2218 BRYAN STREET. SUITE 200 DALLAS.TX ]5201 �214283.8ISfi www.perklnswlll.com CONSULTANTS ava AMERICAN STRUCTUREPOINT ]2fi0 SHADELAND STATION INDIANAPOLIS, IN 66256 STRUCTURAL STANTEC 6080TENNYSON PARKWAY,SUITE200 PlANO,T% ]5024-6003 MEP $WA$$��IATE$ 1I00 PACIRC AVE SUITE 2100 DALLAS.TX ]5201 LANOSCAPING AMERICAN STRUCTUREPOINT INC. �isosHnoe�nNo srnrioN INDIANAPOLIS, IN 4fi25G F00� SERVIGE BOSMA DESIGN SOLUTIONS, INC. 2201 LONG PRAIRIE RD.SUITE 10]-]2] F�owea MouNo, rx �eo�z GONTRAGTOR MEYERNAJEM CONSTRUCTION.LLC 11I8] LAMERN ROAD. SUITE 100 FisHEas. iN asoae STATE OF OBN512019 PROJECT FACILITY: o INDIANAPOLIS � REHABILITATION � HOSPITAL � 1260 CITY CENTER DRIVE � CARMEL, INDIANA46032 � U � � DEVELOPER: N Z � WB DEVELOPMENT o PARTNERS LL 4441 W AIRPORT j FREEWAY, SUITE 330 � IRVING, TX 75062 — KEYPLAN ISSUE CHART MARK ISSUE �ATE JOBNUMBER 14]396.000 ORAWN SH CHECKE� SA APPROVE� CG TITLE INTERIOR PARTITION DETAILS SHEETNUMBER A61-50