HomeMy WebLinkAboutE13-01A - REFLECTED CEILING PLAN -LEVEL 01 -AREA A -LIGHTINGGENERAL NOTES: A. REFERTOARCHIiECiIIRALRERECiEDCEILINGPIANANDELEVATIONSFOREXACT LOCATIONS OF ALL LIGHT FIXTURES. B. REFERTOARCHIiECiIIRALPIANSFOREXACTLOCATIONSANDM011NTINGOFLIGHT FlXTURES. G CONNECTEXITLIGHTSAN�EMERGENCYEGRESSLIGHTS,SHOWNCROSSHATCHE�,TO 2]]I20A BRANCH CIRCUIT SERVWG AREA AND WIRE TO CONTINUOUS HOT AHEAD OF ANV SWITCH ING 11NLE55 NOTE� OTHERWISE. D. CONNECTLIGHTWGT02]]VI20ABRANCHCIRCUITSERVWGAREAINDICATEDBV ENCLOSE��ASHE�LINES. LIGHTWG IS CONTROLLED BV SWITCH (AND OCCUPANCV SENSOR WHERE APPLICABLE) IN IMME�IAiE AREA OR AS IN�ICAiE� W IiH LOWER CASE Sl1B5CRIPT (REFER TO ELECiRICAL SYMBOLS LEGENDiE�.�i �. ANY WIRING SHOWN IS FOR SWITCH LEG CLARIFICATION. E INROOMSIN�ICAiE�TOHAVEMOTIONSENSORSFORLIGHTINGCONTROL,ITSHALLBE THE CONTRACTORS RESPONSIBILITV TO LOCATE AND AIM OCCUPANCV SENSORS IN THE CORRECT pUANTITIES AN� LOCATION(S) AS REpUIRE� FOR COMPLEiE AN� PROPER VO W MEiRIC COVERAGE WIiHIN THE RANGE OF COVERAGE�S) OF CONTROLLE� AREAS PER THE MANUFACTURER'S RECOMMENDATIONS. ROOMS SHALL HAVE N INETV (90) TO ONE HUN�RE� (100) PERCENT COVERAGE TO COMPLETELV COVER iHE CONiROLLE� AREA TO ACCOMMODAiE ALL OCCIIPANCY HABITS OF SINGLE OR MIILTIPLE OCCIIPANTS AT ANY LOCATION WITHIN THE ROOM(S�. THE CONTRACTOR SHALL RE�UIRE THE MANUFACTURER TO PROVI�E SENSORS AS REpU IRE� TO PROPERLV AN� COMPIEiELV COVER iHE RESPECTIVE ROOM. SIIBMIT �RAWINGS SHOWING MODEL NIIMBERS AND DEVICE PIACEMEM FOR REVIEW AND APPROVAL. MOTION SENSOR SHALL BE WATTSTOPPER OR APPROVE� EOl11VAlENT WALL MOIINiE� OR CEILWG MOUMED WITH POWER PACK AND ALL RE�UIRED ACCESSOPoES. WALL MOl1NiE�'. PW-3�1 SINGLE RELAY, PW-3�2 �l1AL RELAY, Al1TOMATIGON OR MANl1AL- ON CONFlGURABIE. cEwNc MouNrEo�. a-zoo, nuroMnric-oN oa MnNuu-oN CONFIGURABIE WITH POWER PACK MODEL BZ450. T/ `Zi6' \3i ���4i1 j ��4.3� T r i ROOMS CONTAIN ING CEILING MOl1NTE� OCCl1PANCY SENSOR�S) AN� WALL SWITCH TO BE WIRED SUCH THAT THE WALL SWITCH CONTROLS CIRCUIT TO OCCUPANCV SENSOR(S) POWER PACK(5�. 5i �5.3 �..6% 6:56.7� i i T F. PROVIDEPHOTOCELL(S�,IDAVASTRONOMICALTIMECLOCKANDSEPARATE RELAYICONTACTOR PANELS FOR NORMAL, CRITICAL AN� LIFE SAFEN BRANCH CIRCIIITING. ROIIiE BRANCH CIRCIIIT hiROl1GH ASSOCIATE� RELAY�CONTACTOR PANEL. CONTROL EXTERIOR LIGHTING AND ILW MINATED SIGNAGE VIA PHOTOCELL AND ] DAV ASiRONOMIGAL TIME GLOGK. PHOTOGELL AN� TIME GLOGK SHALL BE FAIV'ON" NPE. SCHEDULE AS FOLLOWS�. EXTERIOR LIGHTSISIGNAGE- "ON"AT DUSK,'DFF" AT DAYLIGHT. G. WHEREMl1LTIPLELIGHTSWITCHESARELOCAiE�TOGEiHER(GANGE��,PROVI�ESINGIE BACK BOX TO ACCOMMODATE QUANTITY INDICATED AND PROVIDE DIVIDERS TO SEPARATE VOLTAGE AND BRANCH CIRCUITING PER NEC ARTICLE 4048 B. SWITCHES TO BE 11N�ER GOMMON SWITGH PIAiE. GOMMON SWITGH PLAiE GOLOR TO REFLEGT EMERGENCY POWER COMMON SWITCH PLATE COLOR TO RERECT EMERGENCY PO REpUIREMENTS WHEN EMERGENCV SWITCHING IS PRESENT. \�_i SW ASSOCIA' Consul6ng Englneers 1 ]00 Patlfic Ave s�nezioo oauas, Tx �zzo� TeP. P103WDP11 �wswne�a��ee,s.�om PROJECTd19298 KEYED NOTES::*'> NOTE'REFERENCENUMBERINSIDEHEXAGON 1 ROUTETHROUGHCONTACTORIREIAVTOBECONTROLLEDBVPHOTOCELLRIMECLOCK. REFER TO GENERAL NOiE (F) hilS SHEET. 2 ALLLIGHTFlXil1RESWIiHINT0ILETR00MSARE120V. N2 � I ' � U U I na �o� n2 u '�' daos �o� na � na L' na �i� �o� n5 u os �» � � i y � ��� r [7j � I I PAT T�T sn no�. smTe srF. r�r I '� a a � I �° I iaioos I � I�PToos I ' ian�ss J '�Nz �Nz' � anr.r�r. � I � ns ns ns L 1$a '$ r �-------' I � iaHiia �O � I ns �s ns ns ns ns ns ns na ns ns a I ns F2 ns anieooMsi i � � sro� � v�. � � xi ���xi � a � � �a � eHRRs ❑° a ❑° a ] os �� X� 61 �0 6 � i �, iRHin i iRHi]B -------i--------------�'--------J----------------------------------------------�----� �X' �--1------------L------,--------------- , i Xi���'�SS�o T gp -,'gH 9 ❑AZ g2❑ � � � O� w ��� M ' y NORMAL277VLIGHTINGCIRCUIT � Na�iso Na�iso i i Na� NaDa Na[]a a�Na �Na a❑ � -1 �� imm�ss�l inmifss� A^ I �Nz I c�E^" INDICATEDAREA: HA_26 A5 i� o A5 A5 Id n i L2 L2 � A5 2 0 0 o L__ J J2 J2 J2 I ❑ 1RHOD4 � Nd i h h i a 2 N5 0 I o J2 0 o A5 0 � NlOftKR00M lY lY � I��-I z0"5 �-G�' � CC1 �— � J �- � ARi S ° ° pA�_�Zo aviso �a �.iecooi� �Meocns� � Bi�eovnc.� � NORMAL120VLIGHTINGCIRCUIT �«, ioioo5 srnFF�ouNce {5� z��o n� � � sroence iecooa i INDICATEDAREA: �A_58 o w �5 i Na Na i $` � � ❑ �❑ i� � i Na � b Na Na Na I ne ne c�nNwnsti � os �nMiex °RD euiKsioence ' � . ns . ns I Na-iso Na-iso ❑ i 9 9 i ❑ b CC� a❑ a❑ a❑ �� �oio7 . o a iecooa _ 1 ioioos rom�a I-1 � rl ' � o o n5 0� o n5 o n5 � A6 LIFE SAFETY 277V LIGHTING CIRCUIT � uai2o o Na-i2o ,,, Na � � b � � �] [ ❑ ❑ � � � �° SERVINGINDICATEDAREA: LSHA�7 i i IftiYWAS � �� �� � �� � o A6 OFC �� Se $ � � N' �5 i i N4 Cf1 � N4 N4 N4 � DIEi.OFC y� � FlRERISER r � � ❑� iallooa ODz � i i ❑ b a❑ ❑ a� � .�oiooa . $o ioioos I�aa ° 09 na .«��s 1z z iec��a �s "' I I � Nai2o� �--N�120 i i vs �, Evs � � � CRITICAL 277VLIGHTINGCIRCUIT i i a owwc �Q$ o ns � � � �G1 CCi I � �ecoos I � � I SERVINGINDICATEDAREA: DPCRHA-2 �— -- i Na Na i I iomoi I �o ns nz�o na na na na na �K na na � E Na� �❑ ■'i � Na b b Nx Na Na I,fl3 n n .«vs �z �° IieH�iss n5 n5 I Ni Ni I NORMAL 277V LIGHTING CIRCUIT I f' e e E' xi ❑ a❑ ❑ a❑ I I o I b � b � b � o � b � b � b � � � I I INDICATEDAREA:HA_30 Ns f � 9 � CC1 evs soueon c n5 0 I e�f E i � a b seaveRv �� �J ibmn n� "' �� � 1o100Y � �',;o p Ro rt KIiCHEN � � E' �'�N3 � i I ��I w o a 1EG06 RECEIVMG NORMAL720VLIGHTINGCIRCUIT � f E e i i Ns �] CCi Na Na Na I �Az ��� KircneN vs na I I INDICATED AREA: LA_39 I N3 ' ' I�qioos I I] A> >oiou e�f .e i i ❑ 6 a❑ a❑ a❑ I na n� n� � ns� I I LIFESAFEN 277VLIGHTINGCIRCUIT � E �� �N3 i Na Na �i a �ri CC1 ��j �pe f� � a �° a coaa. f7 ���B °1� � aa Aa A4 I � � I SERVINGINDICATEDAREA:LSHA-7 � e ' ❑ ❑' Nx Na bNx b Nx Na Nx � �oaI � Ia FRE�zER coo�ER o A1-120 A6 o ENc.o�icE I I j e .E i i I t•�N3� f i 9 9'i Da ❑y ❑a a❑ a❑ a❑ � �na na� LJ liomal �.ioma� I�R��I I� �o '" � � liecoml � A5� I I E. e Na� E i i I �s$ 0 � �vs,o os� I i � � e � i 91�Na Na0 �' ---As J ns ns ns ns ns ns ns ns ns ns � I �osev i 'i I j�l I � � � NORMAL 277V EXTERIOR LIGHTING � � ieHoo2 i i Xi �� � Xi �O � �O �I �O � x� �O � �s �O � � � � �O Xi � � "� N� � O CIRCUIT INDICATED AREA: HA-32 � O9 O9 i Na Na i Na g�]Na Na❑ � � � ❑ ■ i O g 9 � g 3 Ep�A Eo�A �s�A g__ I LIFE SAFETY 277V LIGHTING CIRCUIT _ _ _ _'_'_ _ �—�---- _ _ _ i �'____ ____'_ _________'____ 1 � � �g �i 9 a�ni��� � a$�o N2 vs�og $vs�o � � A� � �vs� �us — � ��� � � I � SERVINGINDICATEDAREA:LSHA-9 � � oFE�Hn Lsnn Na9 Na9 I____ '❑ gOa�� I TYP�� � b�N2 b� n� A� � � I � I �❑MeaMooanF TYP� �Sno2o � woM� nz�o n2�o I I❑ ❑ Od � n2 � ° Ai-12o � n2 � �ssrn�F I Nz� I � �e �e � � � I � X� � �� ----' 9 . iAMom a a na o �oaKee � z � woKee I I �s �� � � � I Ni Ni I � � ❑N3 I Q r�r "' na eusMca H.e. � os I nz � ns� sH ri� p ro�� ��sn�❑ AZ❑ i- --$ — J I I � ,� �ie�iieoe� a• • a b IinMoos] IinMooal I I � !iarno�@e � L ne a,6 � �� Mnm�creicn� I I I ❑ Na � Na Na❑ __$ _ � p� �� ��z - o a EmiERCENcv I�ecoo9 I I I � m v�snau�e � I�� � M�o�i�ooa�j �� � � � MwcoNF � eiecmron� "n «• I I � I ieNom I na na na woruicoF�e I� I na na �nMom ^^ iecooa ,--. m Na II�_I woeK � . na na na o � o o ns ns ns � «» � � I � � Ne �x� ❑ Na Ne ❑ I I" I�nr:ioos �° � �° na �O iw�n ooa � na � � 05 � � L—_' J � 5� � CI a C� b a�. �� Mecnnwcn� I Ni Ni LJ 1EG�n � I I �------------� L-------J ,s�> ,z �z �z � � � � 8° S� S S S�EcoizE- � B � �s $�s � N� N� � ns nz ns as Hnuwnv ns as � ns ns ns �z �z I � Ad � ❑° °s ° ❑° ❑° � I inMois I�� � xi ��c� o b � a b o5 eioecomao I I '". xz t9f �,s inMoro �I �� � vs o � � � � $uvo $uvo $uvo $vs�o $us�o $vs�o Svsm r-------------------- `��',, I Ni Ni � Ai � �� � A4 � A6 � A6 � Ai � A4 � A4 I � OFFICE OFFlCE OFFlCE I I I��,o�a I � or�ice oFFice oFFice o�rice or�icE � CRITICAL 277V LIGHTING CIRCUIT I I I�nMon . I inMme I iaMoiS I�a��ia l inMma.. . inM�is.. �aMo�� ns ns ns I IN�ICATE� AREA: DPCRHA�2 I � � I A; �° �° A4 �° A4 �° na �° A4 I� na �° A4 �° A4 �` � b a� I CRITICAL 120V LIGHTING CIRCUIT I �� �� I I SERVING INDICATED AREA: CRLB-53 I I _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _i LIFESAFEN 277VLIGHTING ONORMAL277VEXTERIORLIGHTING � � � i CIRCUITSERVINGIN�ICATE�AREA:�SHA-7 LIGHT FIXTURE LEGEND (PARTIAL) CIRCUITINDICATEDAREA:�SHA-9 � I N N I NORMAL 120V LIGHTING CIRCUIT svMeo� oescaiaiioN LIFESAFEN277VLIGHTINGCIRCUIT f � IN�ICATE�AREA:�p_58 SERVINGINDICATEDAREA: HA_32 � i L I I I I �° LIGHTFIXTURE-NORMALPOWERINDICATEDBYOPENCIRCLE. � I � NPICAL FOR ANY LIGHT FIXTl1RE. NORMAL 277V LIGHTING CIRCUIT Az'a . . I � � I I I I � I I INDICATEDAREA:HA-28 NOTe.TexToeNOTesnssocinTeo�FixTUReTvae�nz�;swiTCH�ec��a�. I I — iYPICAL FOR ANY LIGHT RXil1RE. 01, REFL _ vs„_�,o„ li����:��������i,���i���i��������i Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�Ml1 � onrE: 11 /19/19 I�Zy�l�l►[H,�_1►0���/���50_1:��_�:d�[el:��l �LIGHTFlXTURE-LIFESAFETYPOWERINDICATEDBYCROSSHATCH. TVPICAL FOR ANV LIGHT FI%TUPE. �LIGHTFIXTl1RE-CRITICALPOWERIN�ICAiE�BYRLLE�CIRCLE. NPIGLL FOR ANY LIGHT FlXiURE. �DllA1 CIRCIIIT LIGHT RXil1RE - CRITICAL DRNER WILL CONTROL OIIiER LIGHT(S�ANDNORMALDRIVERWILLCONTROLINNERLIGHT(S�. pg�, CEILINGMOIINiE��l1ALiECHNOLOGY0CCIIPANCYSENSORWIiHSWITCH - ' IEGIDENTIFlER. �:v5`� CEILINGMOUNiE��UALiECHNOLOGYVACANCYSENSORWITHSWITCHLEG ' mENnFiER. S' LOWVOLTAGECONiROLLERIETTERDENOTESCONiROLCIRCUITSWITCHLEG. S3 3-WAY LOW VOLTAGE CONiROLLER. S�s WALLMOUMEDDUALTECHNOLOGYOCCUPANCYSENSOR�SWITCH. s"s wu�MouNrEoouurEcnNo�ocvvncnNcvsENsowswircn. $� DIMMERSWITCHICONTROL. REFER TO SHEET E001 FOR COMPLETE ELECTRICAL SYMBOL LEGEND Perkins&Will 2210 BRYAN STREET, SUITE 200 DALLAS, T% ]5201 1214203.0]56 www.peMinswill.com CONSULTANTS CIVIL AMERICANSTRUCTUREPOINT ]260 SHA�EIAN� STATION iNoinNnaous, iN aszss STRULTURNL STANTEC fi�0� TENNYSON PAAKWAY, SI11iE 2�� PLANO, TX ]5024-6003 MEP swassoaares 1]00 PAQFIC AVE, SUITE 2100 onuns, � �szoi LANDSCAPMG AMERICAN STRUCNREPOINT INC. ]2fi� SHADELAND STATION INDIANAPOLIS, IN 46256 F00� SERVICE BOSMA DESIGN SOLUTIONS, INC. 2201 LONG PRAIRIE R�. Sl11TE 10]-]2] FLOWER MOl1Nq iX ]5�22 CONTRACTOR �� oe�isiis OSNS@019 PROJECT rn � 0 N � � 0 Z O F U 7 d' F N Z O U � O LL W � � � FACILITY: INDIANAPOLIS REHABILITATION HOSPITAL PENNSYLVANIA ST AND CITY CENTER DR CARMEL, INDIANA46033 DEVELOPER: WB DEVELOPMENT PARTNERS 4441 W AIRPORT FREEWAY, SUITE 330 IRVING, TX 75062 KEYPLAN A m. ��� ISSUE CHART MARK ISSl1E �AiE JOBNOMBER 14]396000 �RNWN Author CHELKE� Checker NPPROVE� Approver TITLE REFLECTED CEILING PLAN-LEVEL01- AREA A - LIGHTING SHEETNUMBER E13-01A