Loading...
HomeMy WebLinkAboutG02-02 - FIRE RESISTANCE DETAILS AND DIAGRAMSRELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�Ml1 � onrE: 11 /19/19 21i2" MIN MTL STUD 24" OC MAX � � ONE OR TWO LAVERS OF fil8" NPE GVP BD AS RE�UIRED PER - , PARTITIONTVPE �—�� - y -'T� VARIES PROVI�EI6"ORBI '' � STUDS PoR PIPING AT FIRE HOSE ' STL ELECTRICAL PANEL FHG FEC. CABINET ' OTHER RECESSED CABINB OR BOX OVER 16 SQ IN IN FACE SIZE. MAMTAIN FIRE RESISTANT RATING OF THE PARTITION ON ALL SIDES. TOP AND 80TTOM OF THE CA8INET. NOTES'. 1. MAINTAININGFlRERATINGAROUNDCABINBISNOTNECESSARVIFITHASBEENTESTEDASA FIRE-RESISTANT RATE� ASSEMBLV. s. REFERrons�saFORsouNonrrENunrioNOErni�s. � RECESSED WALL CABINET I I � 112„ , �,-0" I RECESSED CABWETS IN RATED WALL � � � THRU-PENETRATION � 3"MINy CENTERLINTEOFSTU�S y3"MIN FIRE STOP SVSTEM , g� 311258" <3" 311258�31H28" .. � / � f 3 T T � �� � � w. ( O � a � o rv� 't -0 E '� OVERSIZEDHOLES < � (BEVOND)THROUGH PARTITION �� TVPE G SCREWS PENETRATION UP TO 3" DIA 0 0 0 � �—� � O � Q � � � t" 0 0 0 o A �� 0 � O f� � NPEGSCREWSfi"OC TVPESSCREWS J�� MIN 2 PER SECTION PENETRATION OVER 3" DIA PATCH � 5/8" GVP BD � JOINTCOMPOUN� (COAT BACK SIDE OF NOTES�. PATCHWITHJOINT 1.APPLVPATCHTOBOTHSIDESOFPARTITION. COMPOUN�) 2.FORABOVECEILINGAN�"BACKOFHOUSE"LOCATIONS. � BASE5�8"GVPB� 3.LEAVEALLSCREWSEXPOSE�. TYP SECTION 4. BUTTER BACK SIDE OF PATCH WITH JOINT COMPoUND. � PENETRATION DETAIL W/ PATCH I V 1 112" =1'-0" I PENETRATIONS IN RATED PARTITION ACOUSTICALSEALANTOR p0"MINBE7WENOUTLET �ONEORTWOLAVERSOF FIRESTOPSEALANTALL gOXESONOPPOSITESI�ESOFWALL 5�8"GVPB�ONEACHSI�E. AROUN�BOX.1i8"MAX i �i REFPARTITIONTVPE ANNULARSPACE . ORSEENOTE4AN�5BELOW pESCRIPTION I I � STEEL TELEPHONE �- MAX 16 SDUARE INCH BO%ES.ELECTRICAL OPENINGINRATE�OR BO%ES. STEELGAS SMOKEWALL OUTLETS. BC. NOTES'. 1. FOR ALL ONE HOOR RATE� PARTITIONS. TWO HOl1R RATE� PARTITIONSAN� SMOKE PARTITIONS. SORFACE AREAOFIN�IVI�UALMETALLICOUTLETORSWITCHBOXESSHALLNOTEXCEE�i65�UAREINCHES. THE AGGREGATED SURFACE OF ALL BOXES SHALL NOT EXCEED 100 S�UARE INCHES IN ANV 100 S�UARE FEET OF WALLAREA 80%ESWHICHE%CEEDTHESESTANDARDSSHALLBERECESSEDASSHOWNIN"RECESSEDWALL CABINET�ETAIL". BOXES<i65�INAN�LOCATE�ONOPPOSITESI�ESOFRATE�FIRESMOKEPARTITI0N5 SHALL BE SEPARATED BV A HORIZONTAL DISTANCE OF 241NCHES M INIMUM. 2. REFERTOPARTITIONDETAILSFORSOUNDATTENUATIONDETAIL. 3. WHERE WALL CAVIN IS FILLE� WITH MINERAL FIBER INSULATION, BO%ES SHALL BE OF ANV MATERIAL AN� SEPARATED BV NOT LESS THAN THE DEPTH OF THE WALL CAVIN. 6. MEMBRANE PENETRATIONS FOR LISTED ELECTRICAL OUTLETS ARE PERMITTED PROVI�E� THEV HAVE BEEN TESTE� FOR USE IN FIRERESISTANT RATE� ASSEMBLIES. 5. ULDESIGNTESTEDLOWRV'SBOXPADSMAVBEUSEDINLIEUOFSEPARATINGTHEBOXESBV24"AND TO PROTECT � 16" SQ e0XE5. NON-LISTED UTILITY BOXES IN RATED � PARTITIONS 3" = 1'-0" I BACK TO BACK OUTLETS .............................. _ � ' 4"MINCTSTUD — STEELJ RUNNER ���� SEAIANT HORIZONTAL DUCT PROTECTI l ll2"=1'-O" I2-HOUR @2HRRATEDASSEMBLV PER USG "SHAFTW SVSTEMS"FOLDER PARTITION 1 AN� 2 UL DESIGN�. U40( SERIES SHAFT WP ASSEMBLV RRERATEDDOOR JAMB ANCHOR CLIP STEELDOORFRAME TAPE AN� JOMT COMPOUND(TVPJ HIGHER PRIORIN PARTITION PARTITION PRIORITY (c� CORRIDOR WALL 3" =1'-0" I PLAN DETAIL AT CROSS CORRIDOR WALL DUCT OPENING STEELJ-RUNNER CEILING STEELCHCHANNEL REXIBLE (OPTIONA srEE� E-sruos BACK-TO-BACK STEELJRUNNER ELEVATION AT DUCT OPENING N.T.S. DAMPER SLEEVE STEELJ-RUNNERHEA�ER j�-�'z'MAX STEELE-STU� � MOUNTINGANGLE -- MOIINTINGANGLE ��- DAMPERSLEEVE SECTION A SECTION B 1-112 HR FIRE DAMPER 1-112 HR FIRE DAMPER u� No R�sais u� no R��ais DUCT OPENING THROUGH SHAFT WALL 1 112" = 1'-0" I DUCT OPENING THRU SHAFT WALL SCHEDULED PARTITION r\ PRovioEFiREREsisrnNr�omrsysrEM z, k: #� ATPENETRATIONTHROUGHFLOORAND ' MM� I BELOWANDDECKABOVE � � FLOOR OR ROOF ASSEMBLV ASINDICATED SEALANT srEE� d RUNNER oucr 1"GVPSUM LINER PANEL 2 ii2" MIN CT STUD 2 LAVERS Si8" GVPBOARD a�nvERs 6/8" GVP BOARD RATED AND SMOKE WALLS SHALL BE CONT BEHIND PIPE TAPE AN� SEAL CONCEALE� JOINTS IN RATED OR SMOKE WALL PER UL �ESIGN OF PARTITION rvaF VERIFV PIPE SIZE 2112" MTL STUDS E%TEN� GVP B� TO 4" MIN ABOVE CEILING LINE PoR FURR-OUT ONLV PARTITION PRIORITY i 1112"=1'-0" IPLANDETAILINTERSECTION OF FIRE-RATED PARTITION AN� NON-FR4TE� EXTERIOR WALL MTLSTUDS �'��� E%TERIOR WALL CLADDING � ti2"GVPSUMSHEATHING 98"GVPBOARD TAPE A� JOMT COMPOUN� 5�8" GVP BOAR� FIRERATED PARTITION EXTERIOR WALL CONTINUOUS GVP BOARD ON HIGHER PRIORITV WALL HIGHER PRIORIN (FIRE-RATE�) PARTITION REF PARTITION CHARTS FOR RATING TAPEAN�JOMTCOMPOUN� LOWER FIRERATING OR NO FlRERATING REF PARTITION CHARTS FOR RATING PARTITION PRIORITY AT PIPE E� 1 112" = 1'-0" I PLAN DETAIL, FURR OUT @ RAIN WATER LEADER � INTERSECTION OF RATED WALLS SHOWING RE � PARTITION PRIORITY � 1 112" = 1'-0" I PLAN DETAIL � ig�_g�� � REFERTOFLOORPLAN FOR DIMENSION �L---------, SIB" GVP BD �I ��. �� � PROVIDE SECOND LAVER OF GVP BD TO BE CONTAROUN� COLUMN WHERE 2- E HOURRATEDPARTITIONABUTSCOLUMN. -- �I�-� _ REFPARTITIONNPE i-------- � i X'-X"MIN I � I x 2 1�2" MIN MTL STU�S WITH 1 112" MWERAL WOOL PARTITION 1 AND 2-HR u� oesicN uaie FIRE-RATED PARTITION COLUMN 1 112" = 1'-0" I PLAN DETAIL FIRE-RATED PARTITION ADJACENTTO STEEL COLUMN 'RIORIN WALL iIORIN WALL WALL PRIORITY LEGEND 2HOORFIREAN�SMOKEWALL PRIORITVI 2HOURFIREWALL PRIORIN2 2 HOUR SHAFiWALL ' 1HOURFIREANDSMOKEWALL PRIORITV3 iHOURFIREWALL PRIORIN4 NON-RATED WALL PRIORIN 5 PARTITION PRIORITY DIAGRAM 1 112" = 1'-0" I PLAN DETAIL Perkins&Will 2218 BRVAN STREEL SUITE 200 DALLAS.TX ]5201 � 214283.8]56 www.perklnswlll.com CONSULTANTS QVIL AMERICAN STRUCTUREPOINT �ssa sHnoE�nNo srnrioN iNoinNnaous, iN aezea STRUCTURAL STANTEC 6080TENNVSON PARKWAV,SUITE200 Pallo, rx isazacaa� MEP $W A$$���ATE$ 1I00 PACIFlC AVE SUITE 2100 �ALLA$ TX ]5201 LANOSCAPING AMERICAN STRUCTUREPOINT INC. ]2605HA�ELAN� STATION INDIANAPOLI$ IN 4fi25fi FOOD SERVICE BOSMA DESIGN SOLUTIONS, INC. ssa� �oNc PRniRiE Ro. suirE �m-�s� FLOWER MOUN�, T%]5022 CONTRACTOR MEYERNAJEM CONSTRUCTION,LLC 11I8] LANTERN ROA�. SUITE 100 FlSHER$ IN 4fi038 STATE OF OBN512019 PROJECT FACILITY: o INDIANAPOLIS � REHABILITATION � HOSPITAL � 1260 CITY CENTER DRNE z0 CARMEL, INDIANA46032 H U � F DEVELOPER: � � WB DEVELOPMENT o PARTNERS LL 4441 WAIRPORT j FREEWAY, SUITE 330 � IRVING, TX 75062 — KEYPLAN ISSUE CHART MARK ISSUE �ATE JOBNOMBER 14]396.000 DRAWN Author CHECKED Checker APPROVED Approver TITLE FIRE RESISTANCE DETAILS AND DIAGRAMS SHEETNUMBER G02-02