HomeMy WebLinkAboutE310 - FIRST FLOOR POWER PLANiWDPA2 -��..�.�..� - II II I L
iLNRA13 L��I
1LLSA1 -
iHC12A1 iHL3A1 � _
1 LEQA1 I I ���. ���JJJ
iHNLA1 iHE�Ai //////
iLCRAi � ,. /
F--� i
�LNRA� ELEC �
8149 1 LC RA4
iLNRA2 ':6051 i i �
iLUA2
i �N rzna onTn z
- B151 TV SVSTEM
1 W RA11
iLNRA6
I 602
SW� pATA� sEcuRiry
i�Nrzns I aiso I PnNe�
NURSE CALL
SW2 � � PANEL
� � AFIREALARM
PANEL
I l
EXISTING
coRRiooR
� BiC11
RELEASED FOR CONSTRl1CTI0N
Su6jec��o compliance with allregula�ions
04 S�a�e antl Local Codes
City of Carmel
y�,:�v��� �'�a;,v��tiw� �
�
onrE: 11 /22/19
r
� IL
�
_i
�
EXISTING
coaaiooa
aicio
[
EXISTING
coRRiooR
sreisl
i i 3 - �� `'
� � � � � � �J
� �
I I
� � �
�-
i
� �
I � I
I
� � I-
II � I \
- �-EXISTING �
PATIENT
TOILET
'�� Ca155 I '
It.; i I
�. � .
L i �
I
�\ I � _, -
II I
��
_ __ -__�� __' -�i__
EXISTING
coaaiooa
81C06
EXISTING
ME�
8156
ww , � www
60I
I ��2
EPO
�96
CLOCK\
� I
� II I � _. .. �;
� ... \� � ...
�__ __ __ �__ __
�
�
I EXISTING
NURSE
I STATION
i 81NO3
-- ^^ ^^ CATH #3 MAIN
/ y �/ y � PANEL
_ u
I sio_
�
— si i'
EPo
EOUIP II
STORAGE
8165
I 608
aeoesrn� •�oz.
� MONITOR .... �
800M '60I:� � �
� �
CATH LAe 609:� .. - .
IX3
Bi66 '
I
EPO
�l uiw��w�u
I —
i—'. —._
coNTao�
B164
\ 3
3
EXISTING
CIRRI�OR
81C08
I I
�" �
� ,, ; t �o�
� �1
�
- ,_ ��� �_- �
I!
� n -.� -- — -- -
_._ ��� II II II II II I CffiBHII
�1 FIRST FLOOR POWER PLAN
va. = r o.
0
�
\
�
EXISTING
CIRRI�OR
BiC13l
I �- - _
� `r----� �i �
i-;.;;i
i�
1�—�1
I1 �.I� -
I �
I �
I
�/ �I
-�---
GENERALNOTES
A. REFERTOSHEETE001FORELECTRICALSYMBOLSAN�A��ITIONALGENERALNOTES.
B. REFER TO MANIIFACTIIRER SRE SPECIRC �RAWINGS FOR A��RIONAL WFORMATION
nNo woRK scoPE FOR TnE cnTn �na. cooRoiNnTE FiNn� EauiPMENT �ocnnoNs
wiTH veNooa.
PLAN NOTES
W2 �ATARACKS LOCATE� IN �ATA 1.
fi05 ALLPNJELBOAR�SINTHISROOMAREEXISTINGTOREMAIN.
fi0] RECEPTACLEFORNEWWALLMOUNTE�MONITOR.CANNECTTOEXISTING120V/20NiP
NORMAL POWER CIRCUIT W THE AREA.
F09 CONNECTNEWMONITORBOOMELECTRICBRAKETO�E�ICATE�SPARE120V/20NiP
CIRCUIT IN NEARBV NORMAL POWER PANELBOAR�.
fiO3 CONNECTNEWMONITORBOOMCIRCUITSTOTHREEDEDICATEDSPARE120V/20NiP
CIRCOITS IN A NEARBV CRITICAL POWER PANELBOAR�.
610 CONNECTNEWIMEGRATIONCABWETRECEPTACLETO�E�ICATE�SPARE120V/20NiP
CIRCUIT IN NEARBV NORMAL POWER PANELBOAR�.
6n CONNECTNEWINTEGRATIONCABWETRECEPTACLETODEDICATEDSPARE120V/20NiP
CIRCOIT IN NEARBV CRITICAL POWER PANELBOAR�.
Y
� v '
W
m �
f a
w
a
N
a� N w
fj C
GJ � U N m
GJ - �i � '- �u
(O @ (i O ¢J L
���d�
�
�
-- - �
_' _ _
- ' __ - _ �
- - _ R
__ �-_ - ,��'
�:e�G`•'�'ERFa o'':
`- �°; No.11400539 " _'-
':'J St.iTFN]F..c��;:
�
Z
IC.IJ
C
w
U
a
J
d
w
�
�
Z
W
�
�
�
�
LI.�
<D
CO
m
m
J a
2 �
H N
ao�
U = y
Z�aM
� O �
_ � � �
J= W Z
r � _
w¢zW
= W p �
x „ Q
� � � U
0
0
� Q T0
� d � � �
`/ m
Y
W 3
� <<
Q
FIRST FLOOR
POWER PLAN
E310