Loading...
HomeMy WebLinkAboutC514 - PLAN & PROFILE (SANITARY)STR. #F Manhole, 4' Dia.; R-1772TC: 853.68STR. #E Manhole, 4' Dia.; R-1772TC: 853.45STR. #D Manhole, 4' Dia.; R-1772TC: 854.55STRUCTURE D - F 261' 0.50% 8" HDPE 427' 0.50% 8" HDPE FG EG FG EGOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUFHVFDC T TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP TP TP TP TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP TP TP TPTPTP TPTPTP TPTPTPTP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP BUSONLY C .O . T Y P E I I C .O . T Y P E I I C .O . T Y P E I I C.O. C.O. C.O.6''SSD6''SSD6''SSD6 ' 'SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD 6''SS D 6''SSD6''SSD 6''SSD 6' 'SSD 6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSD 6''SSD6''SSD 6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD4 " 6 "DOMFIRE PW RD R D R D R DRDRD RD RDRD R D R D RD RD R D RD RD R D R D R D RD R D R D RD R D C.O. C.O. C.O. C.O. 730 RIM=855.10 758 RIM=855.00 722 RIM=854.80 725 RIM=854.75 752 RIM=854.70 759 RIM=854.50 729 RIM=854.30 719 RIM=854.20 721 RIM=854.10 728 RIM=854.00 727 RIM=854.00762 RIM=854.80 751 RIM=853.20 748 RIM=854.50 753 RIM=853.10 717 RIM=853.00 720 RIM=852.90 718 RIM=852.90 750 RIM=852.70 749 RIM=852.50 760 RIM=852.25 761 RIM=851.80 64' OF 12" RCP@0.31% 1 1 2 ' O F 1 2 " R C P@0. 3 1%30' OF 12" RCP@0.33%23' OF 15" RCP@0.34%61' OF 18" RCP@0.31%109' OF 18" RCP @0.30%65' OF 12" RCP@0.45 % 68' O F 1 2 " R C P @0.5 5 % 24' OF 15" RCP @0.85%73' OF 12" R C P @0.55 % 75' O F 1 2 " R C P @ 0 . 5 3 %106' OF 18" R CP @0.42 %105' OF 24" R CP @0.43 %116' OF 24" RCP@0.43%52' OF 24" RCP@0.48%7 4 ' O F 1 2 " H D P E@0. 8 1%54' OF 12" HDPE@0.56 % 9 8 ' O F 1 2 " R C P@0 . 6 1% 5 3 ' O F 1 2 " H D P E@1 . 1 3% 6 7 ' O F 1 2 " H D P E@1. 7 9% 52' OF 12" RCP @0.97% 29' OF 12" RCP @0.45%427' OF 8" H DPE @0.50%26 1 ' O F 8 " H D P E @ 0 . 5 0 % 68' OF 8" HDPE @0.50% 156' OF 8" HDPE @0.50% 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. C514 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 19012L SANITARY SEWER PLAN SCALE:HORZ.: 1"=30' VERT.: 1"=3' GENERAL NOTES LEGEND Existing Grade New Grade Granular Backfill SCALE: 1" = 30' PLAN & PROFILE (SANITARY)