Loading...
HomeMy WebLinkAboutC505 - PLAN & PROFILE (STORM)OHUOHUOHUOHUOHUOHUOHUOHUOHUC.O. C.O. 6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD6''SSDRDRD R D RD R D R D R D C.O. 726 RIM=855.10 725 RIM=854.75 719 RIM=854.20 728 RIM=854.00 RIM=854.00 717 RIM=853.00 716 RIM=853.00 718 RIM=852.90 105' OF 24" RCP @0.43 %116' OF 24" RCP@0.43%52' OF 24" RCP@0.48%54' OF 12" HDPE@0.56 % 9 8 ' O F 1 2 " R C P@0 . 6 1% 6 7 ' O F 1 2 " H D P E@1. 7 9% 52' OF 12" RCP @0.97%427' OF 8" H DPE @0.50 % STRUCTURE 726-725,717 STRUCTURE 719-715STR. #726 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 855.10INV. OUT 851.10 (12" HDPE (SE)) 67' 1.7 9 % 1 2 " H D P E STR. #725 MH 4' DIA; R-3405TC: 854.75INV. IN 849.90 (12" HDPE (NW))INV. OUT 849.80 (12" RCP (E)) 52' 0.97% 12" R C P STR. #717 MH 4' DIA; R-3405TC: 853.00INV. IN 847.30 (24" RCP (S))INV. IN 849.30 (12" RCP (W))INV. OUT 847.20 (24" RCP (N))STR. #719 MANHOLE, 4' DIA.; R-1772TC: 854.20INV. IN 848.45 (18" RCP (SW))INV. IN 849.00 (12" RCP (NW))INV. OUT 848.35 (24" RCP (NE)) 105' 0.43% 24" RCP STR. #718 MH 4' DIA; R-3405TC: 852.90INV. IN 847.90 (24" RCP (SW))INV. OUT 847.80 (24" RCP (N)) 116' 0.43% 24" RCP STR. #717 MH 4' DIA; R-3405TC: 853.00INV. IN 847.30 (24" RCP (S))INV. IN 849.30 (12" RCP (W))INV. OUT 847.20 (24" RCP (N)) 52' 0.48% 24" RCP STR. #716 MH 4' DIA; R-3405TC: 853.00INV. IN 846.95 (24" RCP (S))INV. OUT 846.85 (24" RCP (N)) 142' 0.44% 24" RCP STR. #715 MH 4' DIA; R-3405TC: 851.50INV. IN 846.22 (24" RCP (S))INV. OUT 846.12 (24" RCP (N))10 - YEAR HGL 10 - YEAR HGL FG EG FG EG FG EGOHUOHUOHUOHUOHUOHUOHUOHUOHUC.O. R D R DRDRD RDRD R D R D R D R D 726 RIM=855.10 725 RIM=854.75 717 RIM=853.00 716 RIM=853.00 715 RIM=851.50 116' OF 24" RCP@0.43%52' OF 24" RCP@0.48%142' OF 24" RCP@0.44%60' OF 24" RCP6 7 ' O F 1 2 " H D P E@1. 7 9% 52' OF 12" RCP @0.97% 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 19012L STORM SEWER PLAN SCALE:HORZ.: 1"=30' VERT.: 1"=3' GENERAL NOTES LEGEND Existing Grade New Grade Granular Backfill SCALE: 1" = 30' C505 PLAN & PROFILE (STORM)