HomeMy WebLinkAboutGN 2CLOSING
ROOM
104
� 0
CLOSING
ROOM
105
d
MHX TRHVEL �ISTHNCE = 05' T'
E%IT � — — — — — — — — — — �
� i
i i
I L — �
� WORK
{ AREA
103
r /OFFICE
102
RELEASED FOR CONSTRl1CTI0N
Su6jec��o compliance with allregula�ions
04 S�a�e antl Local Codes
City of Carmel
���,�,,����
2 /
�
� . /
�
J
_�
�`
CLOSING
ROOM
106
0 0
CORRIDOR
,o3�i
_ _ _ — �Ff
r — — _
�
�
BREAK
ROOM I JANITORS
��� I CLOSET
I108
I
I
I i �
I
I
I WOMENS
HESTROOM
I I115
� i0, (Ol
� �. I >._ >_..
I � `O; .
FI I
� II MEN'S
�� RESTROOM
pl 114
al
�II
I RECEPTION
II 100
ROOM SCHEDULE
R
�
�
�
OFFICI � OFFICE
. 109 � � 110 I
�
\
�.
LHX TRHVEL �IBTHNCE =33'�1"
----�\
\� � EXIT
0
NUMBER NAME AREA
100 RECEPTION 204 SF
101 OPEN OFFICE 626 SF
102 OFFICE 103 SF
103 WORK AREA 99 SF
103C CORRIDOR 348 SF
104 CLOSING ROOM 185 SF
105 CLOSING ROOM 185 SF
106 CLOSING ROOM 216 SF
107 BREAK ROOM 316 SF
108 JANITORS CLOSET 45 SF
109 OFFICE 164 SF
110 OFFICE 162 SF
111 OPEN OFFICE 610 SF
112 OFFICE 169 SF
113 WORKAREA 61 SF
114 MEN'S RESTROOM 100 SF
115 WOMEN'S RESTROOM 116 SF
OPEN
OFFICE
111
FECI
I�
I I
rF
OFFICE
112 I
LIFE SAFETY PLAN
SCALE�. 3116" =1' 0"
�D
LIFE SAFETY LEGEND
CFEC FIREEXTINGUISHERCABINETIBRACKET
a �i DENOTES DIRECTION OF EGRE55 TO EXIT DISCHARGE
NOTE: COORDINATE FlNAL FlRE EXTINGUISHER LOCATIONS W ITH LOCAL FlRE CHIEF AS REQU IRED.
NOTE: REFER TO REFLECTED CEILING PLAN AND OR ELECTRICAL ENGINEER �RAW INGS FOR ALL
EMERGENCV AND EXIT LIGHT LOCATIONS.
CODE ANALYSIS
DESCRIPTION RENOVATION
PROPOSED USE OF FACILITY OFFICE BWLDING
BUILDINGCONSTRUCTIONTYPE VB�TABLE503)
OCCUPANCVCLASSIFICATION(S) BUSINESSGROUPB(SECT3041)
OCCUPANCVSEPERATIONSREQUIRED NOTREQUIRED(TABLE508.4)
TOTAL OCCUPANTS PER LOAD FACTORS 3,958 SF I 100 SF PER OCC FACTOR = 40 OCCUPANTS (TABLE
1004.12)
MAX ALLOWABLE/ACTUAL BLDG AREA(S) 18,000 / 3,892 TOTAL SQUARE FEET (TABLE 503)
MAXALLOWABLE/ACTUALBLDGHEIGHT 2/iSTORIES(TABLE503)
AUTOMATIC SPRMKLER SYSTEM NOT REQl11RE� (SECT 903)
PORTABLEFlREEXTMGUISHERS MAXTRAVELDISTANCETOEXTMGUISHER=75(TABLE906.3)
FIRE ALARM SVSTEM NOT REQUIRED (SECT 90])
SMOKEDETECTION NOTREQUIRED�SECT90�)
COMMON PATH OF EGRESS TRAVEL 75 FEET (TABLE 1014.3)
EXITACCESSTRAVELDISTANCE 200FEET(TABLE10162)
CORRI�OR FIRE-RESISTANCE RATING NOT REQUIRED (TABLE 1018.1)
FlRE-RATED STORAGE ROOM OVER 100 SF NOT REQUIRED (TABLE 508.4)
ENCLOSEDEXITACCESSSTAIR NOTREQUIRED(SECT1009)
DEADENDCORRIDORMAX 20FEET�SECT1018.4)
MINCORRIDORWIDTH 361NCHES(TABLE10182)
MIN/MAXDOORWIDTH 32/481NCHE5(SECT1008.1.1)
DOORS EGRESS DOOR MUST SW ING TOWARDS EGRESS WHEN
SERVING SOOR MORE OCCUPANTS. MANUALLY OPERATED
SLIDING DOORS ONLV PERMITTED FROM OCC LOAD SPACES
OF 10 OR LESS (SECT 1008.12)
EXITS REQUIREDIPROVIDED i l3 (TABLE 10212)
VARWNCE�S) NOT REQUIRED
APPLICABLE CODES
CODE DESCRIPTION COMPRISEDOF
GENERALADMINISTRATIONRULES GENERALADMINISTRATIONRULES `6�SIAC12
(ENTIREDOCUMEN� (GAR)(UPDATED08.012014)
(AMENDED 12.012014)
BUILDINGCODE 20141NDWNABWLDINGCODE '2012MTERNATIONAL
(INDIANAAMENDMENTS) QBC)-EFFECTIVE12012014 BWLDINGCODE
FIRECODE 20141NDIANAFIRECODEQFC)- `20121NTERNATIONALFIRECODE
(INDIANAAMENDMENTS) EFFECTNE12.012014 '6151AC22-2S
PLUMBINGCODE 20121NDWNAPLUMBINGCODEQPC�-"2006MTERNATIONALPLUMBING
QNDIANAAMENDMENTS) EFFECTNE12242012 CODE
' 6�51AC 16-1 4
ELECTRICALCODE 20091NDIANAELECTRICAL `2008NFPA]0
QNDIANAAMENDMENTS) CODE QEC)- EFFECTIVE 08282009 ' 8751AC 17-1.8
MECHANICALCODE 20141ND�ANAMECHANICAL '20121NTERNATIONAL
QNDIANAAMENDMENTS) CODEQMC)-EFFECTNE12.012014 MECHANICALCODE
` 6�51AC 18-1 6
HANDICAPACCESSIBILITVCODE 20141NDIANABWLDINGCODE `6�SIAC13-2S-12CHAPTERII
QNDIANAAMENDMENTS) CHAPTERII-ACCESSIBILITI' 'A117.1ACCESSIBLEANDUSABLE
BUILDINGS AND FAQLIITES, 2009
EDITION
ENERGVCODE 20101NDIANAENERGV 'ASHRAE90.12007
QNDIANAAMENDMENTS) CONSERVATIONCODEQECC)- '6151AC19.3
EFFECTNE OS.OL2010
m itsch
�ESIGN
200 s rangeline road
suite 226
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www. m itschdesign.com
z
0
J
�M
W
w
U
�
�
O
N
H
U..�
W
_
U
�
Z
NO
� Q
� O
Z Z
W W
U�
w
J
�
�
Z
0
Zc
G
O
�
�rn
V
Z
�
Z
w
J
w
�
Ov
J
W J
0 w
HU
� >
w�
J w
� �
W
>
�
0
J N
W M
�o
��
Q
U?
� J
Q W
w�
K
vQ
NU
.. . . .
�\ '
PO� ' � � ,
���o v �
m
� W � 0 d r _
N O F =
~d"d �N ♦
¢
6,��5 � P;,_
�
oc
�O2rc€�
°€F'oo
oj�,
a¢ao.¢�
DRAWNBV:
CHECKEDBV:
MDPROJECT#:
KWIRB
RH
19056
H
�
GN
L.L
W
�
LIFE SAFETY PLAN 8
CODE INFORMATION
G001
F �
r oi `o �
y w z no
O
Q W� W U � O�
zln�v�� o
�zoFa � a
W��
w'3orcz
rcttOWO °-°
aa¢mo � '
N��� p m
���� o ry
oo�o� Z N
onrE: 12/02/19