HomeMy WebLinkAboutA1.2 - CEILINGELECTRICAL PLANSDrawn By Checked By
Architecture / Project Managment:
Carmel, Indiana 46032
317.705.7980 (fax)
355 City Center Drive
317.705.7979 (phone)
SEAL:
COPYRIGHT & OWNERSHIP OF DOCUMENTS
ARCHITECT / PROJECT MANAGEMENT
PROJECT
PROJECT NUMBER
SHEET TITLE
SHEET NUMBER
REVISION DATE
ISSUE DATE
Print Date
SUITE 400OLD TOWN SHOPS IEMERSON LAW1 SOUTH RANGELINE ROAD9/30/2019 SATATE REALEASE SET
CARMEL, INDIANA46032PEDCOR DESIGN GROUP
CEILING/
ELECTRICAL
PLANS
9/30/2019
A1.2
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, L.L.C. ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION
AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND
PEDCOR DESIGN GROUP, L.L.C. NO PART OR WHOLE OF THIS DESIGN,
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,
MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE
SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.
STUTZMAN AND PEDCOR DESIGN GROUP, L.L.C. c COPYRIGHT 2019
JAMES R. STUTZMAN, AIA, CARMEL, INDIANA
MC TJ
9/30/2019
7'-6"
TIGHT TO JOIST
8'-0"
8'-0"
8'-0"8'-0"8'-0"
8'-0"
8'-0"
8'-0"
8'-0"8'-0"
8'-0"
8'-0"
8'-0"
CP4
CP4
CP4
CP4
CP4
CP4
CP4
CP4
CP4
CP4 CP5
CP4
CP1 CP3
CP5 CP6
CP1
CP3
CP5
CP6
CP2
CP3
CP5
CP6
CP1 CP3
CP5 CP6
CP6
CP4 CP5
CP6
3
3
3
9 7 6 510
BE.8AC.2EDD 3N
N
NL
NL
NL
NL
D
N
N R
R
R
R
N
R R
REP1
EP1
EP1
EP1
EP1
EP1
REST ROOM
413
REST ROOM
412
RECEPTION
401
OFFICE
404
OFFICE
406
WORK ROOM
402
CLOSET
403
OFFICE
409
CONFERENCE
ROOM
411
CORRIDOR
415
+54
9 7 6 510
BE.8AC.2EDCORRIDOR
416
CORRIDOR
414
C
C
C+54 +54
+54
+54+54
+44 +44
+60 +44
GFI
C +54+54
OFFICE
405
OFFICE
407
SHARED
OFFICE
408
OFFICE
410
N
N
N
N
N
NN N
NN N
NN N
EP1
GENERAL ELECTRICAL/DATA NOTES:
ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL
STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE
PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT
UNLESS OTHERWISE INDICATED.
ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL
ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY
ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR
DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION.
ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED
@ 18" AFF UNLESS NOTED OTHERWISE.
6.
5.
4.
3.
2.
ELECTRICAL/DATA LEGEND:ELECTRICAL/DATA PLAN NOTES:
PROVIDE NEW ELECTRICAL AND DATA OUTLETS AS SHOWN WITH 'N'.
INCLUDE WIRING.
ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. EXPOSED CONDUIT IS TO BE RIGID.
ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO MATCH COLOR OF EXISTING COVER
PLATES.
DUPLEX WALL OUTLET.
PHONE/DATA WALL OUTLET (BOX AND PULL STRING).
DENOTES NEW OUTLET LOCATION.
DENOTES HEIGHT A.F.F. TO CENTER OF OUTLET.
N
+44
DENOTES A DEDICATED OUTLET.D
FLOOR OUTLET WITH DUPLEX POWER AND DATA.
1.FURNITURE SHOWN FOR REFERENCE ONLY.
CABLE OUTLET.C
GROUND FAULT INTERRUPT CIRCUIT.GFI
GENERAL CEILING NOTES:
1.MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING
CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE
PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD
CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL
DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND
FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE
PROCEEDING.
5.
6.
4.
3.
2.
ALL WALLS GO TO UNDERSIDE OF FINISHED CEILING UNLESS NOTED OTHERWISE. SEE
CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION.
EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO
ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE
SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG
PLATE CONDITION.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS.
CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS,
ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY
CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING
PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR
REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW
ONLY.
CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO
ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION.
ALL SUSPENDED CEILING HEIGHTS ARE TO BE 8'-0" UNLESS NOTED OTHERWISE. ADJUST DUCT
HANGERS AS REQUIRED TO PROVIDE CEILING HEIGHT.
CEILING PLAN NOTES:
CP1 REINSTALL DEMO'D LIGHTING WHERE SHOWN WITH AN "R".
REFLECTED CEILING LEGEND:
NEW 2 X 2 FLUORESCENT LIGHT FIXTURE TO BE: METALUX LIGHTING 2GR8-2U6T8PB1S-UNV-L8735-EB81-U OR EQUAL.
EXISTING EMERGENCY LIGHT FIXTURE.
NEW 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, DUNE, BEVELED TEGULAR,
W/ PRELUDE.XL 15/16" GRID.
EXISTING WALL MOUNTED EXIT LIGHT TO BE: LITHONIA LIGHTING, SURFACE MOUNT EDGE-LIT EXIT LIGHT,
EDG 1R 120/277 ELN, OR EQUAL.
TWO WAY SWITCH.
3 THREE-WAY SWITCH.
NL NIGHTLIGHT LOCATION.
CP2 PROVIDE NEW LIGHT FIXTURES TO MATCH EXISTING
METALUX LIGHTING 2GR8-432PB5-UNV-L8735-EB81-U.
E EXISTING LIGHT SWITCH LOCATION.
7.REPLACE MISSING OR DAMAGED CEILING TILES. NEW TILES TO MATCH EXISTING CEILING.
CP3 REWIRE THE LIGHTS SO THEY ARE CONTROLLED BY THE
SWITCH WITHIN THE ROOM.
NEW 2 X 4 FLUORESCENT LIGHT FIXTURE TO BE: METALUX LIGHTING 2GR8-432PB1S-UNV-L8735-EB81-U OR EQUAL.
NEW PENDANT LIGHT FIXTURE TO BE: HUBBARDTON FORGE, SMALL EXOS PENDANT #139590, WITH
SATIN STEEL -19 FINISH, NATURAL LINEN-32 SHADE, AND A-19 100W LAMP.
NEW RECESSED DOWNLIGHT TO BE: PORTFOLIO LIGHTING C6042E 6001LI HB26 OR EQUAL.
D DIMMER SWITCH LOCATION.
CP4 REPLACE LENSES IN ALL FIXTURES AND ALL BURNT-OUT
AND DIFFERENT COLORED LAMPS. ALL LAMPS TO HAVE THE
SAME COLOR TEMPERATURE.
CP5 REWORK HVAC DUCTWORK AS NEEDED FOR NEW OFFICE
LAYOUT.
CP6 ADD FIRE PROTECTION AND LIFE SAFETY ITEMS AS
REQUIRED FOR NEW LAYOUT.
N
N
SCALE: 1/8" = 1'-0"
1 REFLECTED CEILING PLAN
A1.2
SCALE: 1/8" = 1'-0"
2 ELECTRICAL/DATA PLAN
A1.2