Loading...
HomeMy WebLinkAboutA1.2 - CEILINGELECTRICAL PLANSDrawn By Checked By Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) SEAL: COPYRIGHT & OWNERSHIP OF DOCUMENTS ARCHITECT / PROJECT MANAGEMENT PROJECT PROJECT NUMBER SHEET TITLE SHEET NUMBER REVISION DATE ISSUE DATE Print Date SUITE 400OLD TOWN SHOPS IEMERSON LAW1 SOUTH RANGELINE ROAD9/30/2019 SATATE REALEASE SET CARMEL, INDIANA46032PEDCOR DESIGN GROUP CEILING/ ELECTRICAL PLANS 9/30/2019 A1.2 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, L.L.C. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, L.L.C. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, L.L.C. c COPYRIGHT 2019 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA MC TJ 9/30/2019 7'-6" TIGHT TO JOIST 8'-0" 8'-0" 8'-0"8'-0"8'-0" 8'-0" 8'-0" 8'-0" 8'-0"8'-0" 8'-0" 8'-0" 8'-0" CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP5 CP4 CP1 CP3 CP5 CP6 CP1 CP3 CP5 CP6 CP2 CP3 CP5 CP6 CP1 CP3 CP5 CP6 CP6 CP4 CP5 CP6 3 3 3 9 7 6 510 BE.8AC.2EDD 3N N NL NL NL NL D N N R R R R N R R REP1 EP1 EP1 EP1 EP1 EP1 REST ROOM 413 REST ROOM 412 RECEPTION 401 OFFICE 404 OFFICE 406 WORK ROOM 402 CLOSET 403 OFFICE 409 CONFERENCE ROOM 411 CORRIDOR 415 +54 9 7 6 510 BE.8AC.2EDCORRIDOR 416 CORRIDOR 414 C C C+54 +54 +54 +54+54 +44 +44 +60 +44 GFI C +54+54 OFFICE 405 OFFICE 407 SHARED OFFICE 408 OFFICE 410 N N N N N NN N NN N NN N EP1 GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 6. 5. 4. 3. 2. ELECTRICAL/DATA LEGEND:ELECTRICAL/DATA PLAN NOTES: PROVIDE NEW ELECTRICAL AND DATA OUTLETS AS SHOWN WITH 'N'. INCLUDE WIRING. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. EXPOSED CONDUIT IS TO BE RIGID. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO MATCH COLOR OF EXISTING COVER PLATES. DUPLEX WALL OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). DENOTES NEW OUTLET LOCATION. DENOTES HEIGHT A.F.F. TO CENTER OF OUTLET. N +44 DENOTES A DEDICATED OUTLET.D FLOOR OUTLET WITH DUPLEX POWER AND DATA. 1.FURNITURE SHOWN FOR REFERENCE ONLY. CABLE OUTLET.C GROUND FAULT INTERRUPT CIRCUIT.GFI GENERAL CEILING NOTES: 1.MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 5. 6. 4. 3. 2. ALL WALLS GO TO UNDERSIDE OF FINISHED CEILING UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. ALL SUSPENDED CEILING HEIGHTS ARE TO BE 8'-0" UNLESS NOTED OTHERWISE. ADJUST DUCT HANGERS AS REQUIRED TO PROVIDE CEILING HEIGHT. CEILING PLAN NOTES: CP1 REINSTALL DEMO'D LIGHTING WHERE SHOWN WITH AN "R". REFLECTED CEILING LEGEND: NEW 2 X 2 FLUORESCENT LIGHT FIXTURE TO BE: METALUX LIGHTING 2GR8-2U6T8PB1S-UNV-L8735-EB81-U OR EQUAL. EXISTING EMERGENCY LIGHT FIXTURE. NEW 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, DUNE, BEVELED TEGULAR, W/ PRELUDE.XL 15/16" GRID. EXISTING WALL MOUNTED EXIT LIGHT TO BE: LITHONIA LIGHTING, SURFACE MOUNT EDGE-LIT EXIT LIGHT, EDG 1R 120/277 ELN, OR EQUAL. TWO WAY SWITCH. 3 THREE-WAY SWITCH. NL NIGHTLIGHT LOCATION. CP2 PROVIDE NEW LIGHT FIXTURES TO MATCH EXISTING METALUX LIGHTING 2GR8-432PB5-UNV-L8735-EB81-U. E EXISTING LIGHT SWITCH LOCATION. 7.REPLACE MISSING OR DAMAGED CEILING TILES. NEW TILES TO MATCH EXISTING CEILING. CP3 REWIRE THE LIGHTS SO THEY ARE CONTROLLED BY THE SWITCH WITHIN THE ROOM. NEW 2 X 4 FLUORESCENT LIGHT FIXTURE TO BE: METALUX LIGHTING 2GR8-432PB1S-UNV-L8735-EB81-U OR EQUAL. NEW PENDANT LIGHT FIXTURE TO BE: HUBBARDTON FORGE, SMALL EXOS PENDANT #139590, WITH SATIN STEEL -19 FINISH, NATURAL LINEN-32 SHADE, AND A-19 100W LAMP. NEW RECESSED DOWNLIGHT TO BE: PORTFOLIO LIGHTING C6042E 6001LI HB26 OR EQUAL. D DIMMER SWITCH LOCATION. CP4 REPLACE LENSES IN ALL FIXTURES AND ALL BURNT-OUT AND DIFFERENT COLORED LAMPS. ALL LAMPS TO HAVE THE SAME COLOR TEMPERATURE. CP5 REWORK HVAC DUCTWORK AS NEEDED FOR NEW OFFICE LAYOUT. CP6 ADD FIRE PROTECTION AND LIFE SAFETY ITEMS AS REQUIRED FOR NEW LAYOUT. N N SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 1/8" = 1'-0" 2 ELECTRICAL/DATA PLAN A1.2