HomeMy WebLinkAboutA000.31900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
Suzette Schuette06/07/2013
GARAGE RIGHT
Croix
1993.301
LOT 29
11/01/2019
PLOTTED: November 1, 2019 / Nick Musial / 1993-CROIX-CZ-BAS2-EL-HR2C.DWG
A3
HR2C-2GS.1Heartland 2C - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule\A1;1'-1"
1012
1012
\A1;4'-6" A.F.F.
\A1;3'-2" TYP.
SHINGLES PERSUB. SPECS.
SIDING PER SPECS
8" TRIM4" TRIM (TYP.)
4" TRIM (TYP.)
SHINGLES PERSUB. SPECS.
SIDING PER SPECS
SIDING PER SPECS8" TRIM4" TRIM (TYP.)
4" TRIM SURROUND ON DOOR 10" SQ. COLUMN(SEE PORCH DETAIL)8" TRIM4" TRIM BOARD
\A1;3'-0"
SHAKE SIDING PER SPECS
8" TRIM
16x36 LOUV. VENT
SHINGLES PER SPECS.SHINGLES PER SPECS.
ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC\A1;2'-3{\H0.750000x;\S3#8;}"
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
SECOND FLOOR PLATE WINDOW HDR. HGT.
TOP OF FOUNDATION
BRICK WAINSCOTT. \PPER SPEC.
SCALE:FRONT ELEVATION1/4" = 1'-0"-
BRICK WAINSCOTT. \PPER SPEC.T.O. FOUNDATIONT.O. FLOOR
T.O. PLATE\A1;8'-1{\H0.750000x;\S1#8;}"
ROOF SHINGLES, \PPER SPEC
\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
WINDOW HDR. HGT.
SECOND FLOOR \PPLATE WINDOW HDR. HGT.
SCALE:REAR ELEVATION1/8" = 1'-0"-
FIRST FLOOR LINE
10:1210:12\A1;1'-1"
SIDING PER SPECS
\A1;2'-0"
6" CORNER BD.ON FRONT ELEV. &4" ON SIDES& REAR ELEV.
ROOF SHINGLES, \PPER SPEC
6" FASCIA BOARD, \PPER SPEC
BRICK WAINSCOTT. \PPER SPEC.
127127
SECOND FLOOR \PPLATE
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}"
WINDOW HDR. HGT.
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
10:12
T.O. PLATET.O. FLOORWINDOW HDR. HGT.
\A1;1'-1"
\A1;1'-1"
T.O. FOUNDATION
SCALE:LEFT ELEVATION1/8" = 1'-0"-
\A1;24'-0"
\A1;10'-0"
\A1;1'-0"\PTYP.
\A1;6'-0"
\A1;1'-0"\PTYP.
SCALE:ROOF PLAN1/8" = 1'-0"-
ROOF AREA"A"3309 SQ. FT.
7:12
7:12
10:12
10:1210:12
10:12
10:12
ELEVATION HR2C
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3309 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.41 5.52 5.08 49.73 12 0
AT EAVE 6.62 5.52 5.14 50.27 0 74.00
TOTAL (MIN)11.03 11.03 10.22 100.00
3
HIGH -
RIDGE VENT 4.41 5.52 5.00 49.32 0 0 40.00
AT EAVE 6.62 5.52 5.14 50.68 0 74.00
TOTAL (MIN)11.03 11.03 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
BRICK WAINSCOTT. \PPER SPEC.
127127
FIRST FLR LINE
SIDING PER SPECS
6" CORNER BD.ON FRONT ELEV. &4" ON SIDES& REAR ELEV.
ROOF SHINGLES, \PPER SPEC
6" FASCIA BOARD, \PPER SPECSECOND FLOOR \PPLATE
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}"
WINDOW HDR. \PHGT.
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
T.O. PLATET.O. FLOORWINDOW HDR. \PHGT.
T.O. FOUNDATION
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
12/02/19
William Hohlt