Loading...
HomeMy WebLinkAboutA000.31900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette06/07/2013 GARAGE RIGHT Croix 1993.301 LOT 29 11/01/2019 PLOTTED: November 1, 2019 / Nick Musial / 1993-CROIX-CZ-BAS2-EL-HR2C.DWG A3 HR2C-2GS.1Heartland 2C - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule\A1;1'-1" 1012 1012 \A1;4'-6" A.F.F. \A1;3'-2" TYP. SHINGLES PERSUB. SPECS. SIDING PER SPECS 8" TRIM4" TRIM (TYP.) 4" TRIM (TYP.) SHINGLES PERSUB. SPECS. SIDING PER SPECS SIDING PER SPECS8" TRIM4" TRIM (TYP.) 4" TRIM SURROUND ON DOOR 10" SQ. COLUMN(SEE PORCH DETAIL)8" TRIM4" TRIM BOARD \A1;3'-0" SHAKE SIDING PER SPECS 8" TRIM 16x36 LOUV. VENT SHINGLES PER SPECS.SHINGLES PER SPECS. ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC\A1;2'-3{\H0.750000x;\S3#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT SECOND FLOOR PLATE WINDOW HDR. HGT. TOP OF FOUNDATION BRICK WAINSCOTT. \PPER SPEC. SCALE:FRONT ELEVATION1/4" = 1'-0"- BRICK WAINSCOTT. \PPER SPEC.T.O. FOUNDATIONT.O. FLOOR T.O. PLATE\A1;8'-1{\H0.750000x;\S1#8;}" ROOF SHINGLES, \PPER SPEC \A1;7'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" WINDOW HDR. HGT. SECOND FLOOR \PPLATE WINDOW HDR. HGT. SCALE:REAR ELEVATION1/8" = 1'-0"- FIRST FLOOR LINE 10:1210:12\A1;1'-1" SIDING PER SPECS \A1;2'-0" 6" CORNER BD.ON FRONT ELEV. &4" ON SIDES& REAR ELEV. ROOF SHINGLES, \PPER SPEC 6" FASCIA BOARD, \PPER SPEC BRICK WAINSCOTT. \PPER SPEC. 127127 SECOND FLOOR \PPLATE \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}" WINDOW HDR. HGT. \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" 10:12 T.O. PLATET.O. FLOORWINDOW HDR. HGT. \A1;1'-1" \A1;1'-1" T.O. FOUNDATION SCALE:LEFT ELEVATION1/8" = 1'-0"- \A1;24'-0" \A1;10'-0" \A1;1'-0"\PTYP. \A1;6'-0" \A1;1'-0"\PTYP. SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREA"A"3309 SQ. FT. 7:12 7:12 10:12 10:1210:12 10:12 10:12 ELEVATION HR2C ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3309 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.41 5.52 5.08 49.73 12 0 AT EAVE 6.62 5.52 5.14 50.27 0 74.00 TOTAL (MIN)11.03 11.03 10.22 100.00 3 HIGH - RIDGE VENT 4.41 5.52 5.00 49.32 0 0 40.00 AT EAVE 6.62 5.52 5.14 50.68 0 74.00 TOTAL (MIN)11.03 11.03 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE BRICK WAINSCOTT. \PPER SPEC. 127127 FIRST FLR LINE SIDING PER SPECS 6" CORNER BD.ON FRONT ELEV. &4" ON SIDES& REAR ELEV. ROOF SHINGLES, \PPER SPEC 6" FASCIA BOARD, \PPER SPECSECOND FLOOR \PPLATE \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}" WINDOW HDR. \PHGT. \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" T.O. PLATET.O. FLOORWINDOW HDR. \PHGT. T.O. FOUNDATION SCALE:RIGHT ELEVATION1/8" = 1'-0"- 12/02/19 William Hohlt