HomeMy WebLinkAboutA200.01900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
Suzette Schuette06/07/2013
GARAGE RIGHT
Croix
1993.301
LOT 29
11/01/2019
PLOTTED: November 1, 2019 / Rohit Gupta / 1993-CROIX-CZ-BAS2-PLAN.DWG
A1
4-2.1Second Floor Plan.4" Exterior WallsSCALE:SECOND FLOOR PLAN - 4" EXTERIOR WALLS1/4" = 1'-0"-
DN 16R
30X60 TUB/SHOWER
HANDRAIL, PER CODE
123456789101112131415
TRTP
\A1;10'-7{\H0.750000x;\S1#2;}"\A1;4'-0"\A1;14'-7{\H0.750000x;\S1#2;}"\A1;9'-8"\A1;6'-0"\A1;6'-0"\A1;24'-3{\H0.750000x;\S1#2;}"\A1;26'-8{\H0.750000x;\S1#2;}"\A1;2'-0"\A1;67'-0" - OVERALL
\A1;67'-0" - OVERALL \A1;30'-8{\H0.750000x;\S1#2;}"\A1;19'-11"\A1;4'-4{\H0.750000x;\S1#2;}"\A1;12'-0"
\A1;14'-0"
\A1;7'-0"
\A1;14'-0"
\A1;19'-0"
\A1;54'-0" - OVERALL
\A1;8'-8"
\A1;5'-3{\H0.750000x;\S1#2;}"
\A1;13'-8"
\A1;35'-7{\H0.750000x;\S1#2;}"
\A1;40'-0"
\A1;14'-0"
\A1;54'-0" - OVERALL
\A1;3'-8{\H0.750000x;\S1#2;}"\A1;9{\H0.750000x;\S1#2;}"
\A1;17'-2"
\A1;13'-7{\H0.750000x;\S1#2;}"
\pxql;42" WALL w/ \PCAP, PER SPEC
BEDROOM 48'-0" CLG.
WIC8'-0" CLG.
BATH 48'-0" CLG.
LOFT8'-0" CLG.
\A1;7'-0"\A1;12'-7"
\A1;2'-0{\H0.750000x;\S1#2;}"\A1;1'-9"
TB
1R/1S
1R/1S
1R/1S2/10
2/102/10
\A1;8'-0"HVAC8'-0" CLG.
\A1;5'-10{\H0.750000x;\S1#2;}"\A1;1'-11{\H0.750000x;\S1#2;}"
2/8
\A1;1'-6"
FD
(2) 3053 SH
\A1;4'-0"
\A1;18'-5"
\A1;2'-0{\H0.750000x;\S1#2;}"
1A2 S.1
3A2 S.2 3A2 S.2
1A2 S.1
2A2 S.1
2A2 S.1
LINE OF SLOPED CLG.
LINE OF SLOPED CLG.
ATTIC ACCESS
22"x30" ATTIC ACCESS
LINE OF SLOPED CLG.\A1;1'-0"
ATTIC ACCESS THROUGH WALL TO BE INSULATED (TYP.)
\A1;1'-0"LINE OF WALL BELOWLINE OF WALL BELOW
LINE OF WALL BELOW
LINE OF WALL BELOW
LINE OF WALL BELOW
LINE OF PORCH BELOW
LINE OF WALL BELOWLINE OF WALL BELOW
LINE OF WALL BELOW
LINE OF WALL BELOW
LINE OF WALL BELOW
\A1;2'-0"
\pxql;DOUBLE 2X4 WALL
\A1;{\LGENERAL SPECIFICATIONS\P\P\pxi-2,l2,t2;}1. ALL ANGLED WALLS (OTHER THAN THOSE AT 90%%D) SHALL BE CONSIDERED TO BE AT 45%%D UNLESS NOTED OTHERWISE\P2. ALL STUDS AT EXTERIOR AND INTERIOR WALLS SHALL BE 2x4 UNLESS OTHERWISE NOTED\P3. ALL STUDS AT EXTERIOR WALLS AND INTERIOR BEARING WALLS TO BE FRAMED AT 16" O.C. UNLESS NOTED OTHERWISE\P4. ALL NON-BEARING WALLS, OTHER THAN IN THE KITCHEN AND PLANNING CENTERS, TO BE 2x4 STUDS AT 24" O.C. UNLESS OTHERWISE NOTED OR RESTRICTED BY LOCAL CODES OR ORDINANCES. KITCHEN AND PLANNING CENTER WALLS WHERE WALL CABINETS ARE TO BE HUNG SHALL BE FRAMED AT 16" O.C.\P5. PROVIDE DOUBLE 2x TOP PLATES AT ALL LOAD BEARING WALLS.\P6. PROVIDE SINGLE TOP PLATE AT ALL INTERIOR NON-LOADING BEARING WALLS.\P7. PROVIDE A 1-3/8" OR LARGER SOLID CORE WOOD DOOR, SOLID CORE STEEL DOOR OR HONEYCOMB CORE STEEL DOOR, OR 20 MINUTE FIRE-RATED DOOR EQUIPPED WITH A SELF-CLOSING DEVICE BETWEEN GARAGE AND LIVING SPACE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE. \P8. PROVIDE FIRE SEPARATION BETWEEN DWELLING AND GARAGE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P9. PROVIDE {\H0.7x;\S1#2;}" DRYWALL AT WALLS, CEILING AND UNDERSIDE OR STAIR ASSEMBLY ACCESSIBLE SPACE UNDER STAIRS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P10. ALL GLAZING INSTALLED IN HAZARDOUS LOCATIONS AS DEFINED BY THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE SHALL HAVE A PERMANENT DESIGNATION OR LABEL AFFIXED TO EACH PANE OF GLAZING BEARING THE MANUFACTURER'S LABEL SHOWING THE TYPE AND THICKNESS OF GLASS. FOR OTHER THAN TEMPERED GLASS, LABELS MAY BE OMITTED PROVIDED THE BUILDING OFFICIAL APPROVES THE USE OF A CERTIFICATE, AFFIDAVIT OR OTHER EVIDENCE CONFIRMING COMPLIANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P11. ALL BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT NOT LESS THAN 72" ABOVE THE FLOOR PER THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P12. PROVIDE THERMO-PLY SHEATHING AND BATT INSULATION FILLING ALL CAVITIES AT EXTERIOR WALLS SURROUNDING TUBS AND SHOWERS.\P13. ALL REQUIRED GUARDRAILS AND GUARDWALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. GUARDS SHALL NOT BE LESS THAN 36" HIGH MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE AND NOT LESS THAN 34" HIGH MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS.\P14. ALL REQUIRED HANDRAILS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS. HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34" OR MORE THAN 38" AS MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS AND SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL.\P15. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM MUST HAVE AT LEAST ONE EMERGENCY ESCAPE OR RESCUE OPENING IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. WHERE THE BASEMENT CONTAINS 1 OR MORE SLEEPING ROOMS, EMERGENCY ESCAPE OR RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. THE EMERGENCY ESCAPE OR RESCUE OPENING SHALL HAVE A CLEAR 5.7 SQUARE FEET OF OPEN AREA WITH A SILL HEIGHT OF NO MORE THAN 44" ABOVE THE FLOOR OR 5.0 SQUARE FEET OF OPEN AREA FOR GRADE-FLOOR WINDOWS. THE CLEAR OPENING SHALL A MINIMUM OF 24" OF OPENING HEIGHT AND 20" OPENING WIDTH. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE ADJACENT GROUND LEVEL ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL AND LADDER IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P16. FOR ADDITIONAL INFORMATION SEE STRUCTURAL DRAWINGS AND NOTESFLOORPLAN NOTES
12/02/19
William Hohlt