Loading...
HomeMy WebLinkAboutP101RELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � onrE: 12/02/19 � 53 R 52 �51 49 � 48 �00l�t 4] q� 46 I�E NI 44 MMO� 43 II 9 4z 0 41 � 39 � 38 3] � 36 33 �Q � 34 � � 32 �� 31 � p� 29 28 n 21 �� 26 �� 24 � 23 p� zz 5] � 56 � �6NNLJ ��MOM'� 11 � 12 R 13 �,a K is � 1] �� 18 u �y �yp 21 58 �� 59 �� 61 � 62 63 '� •noi LJIZ aCNI 66 6] 68 69 �� �� w�F1s �Z u ]3 ]6 �� � LJ�� MIY ��wo l:l°" �� �ny¢m l:l�� N10 KITCHEN EQUIPMENT PLAN scue: �a��=r�a� IEem 6 11 12 13 14 19 42 iS � � � 31 � 41 � 14 � 52 53 81 N 72 73 74 78 �ramrF Fland SNk Yfru er�FihaUon �lam. far YulSpls APP�� Tne (3) CampaiUmnt Sfnk OIM�adier� Undnoounlx Raach-M Fnssr R�odrin R�IAgwoWr Comeelion Own. fletUk Faod Pon Wanw�� Cant�rlaP �I�lO� w01�4 T0� RapiE Cook Oran ICa CIIba1 �1 BYI Rtdwr 16sr Dlop-il $Ylk Orop-M SNk Glan fial Co(fw de�ar CoNw Bre�ar UnOeitoudx Rehlqxotor ka Craam dppa�all Undoroantar Rahlqxatar �IMacMiw S 4Yaq PRcher 16nar 3" HFAT 2" SAN \/ � 2" GW - 12 :ii I � 13 �__ � 8 O FD-1 01=1 � � � p J �� 7' 11P TO 3" V�R �� I- �. p �f O T� — __ �=—,4pF — ___ 1 I I � �� � II � �� �� I �� � � �� ,o �1; � o-_J 1" IN BEAM WEB 2" UP TO 3" VrR 3/4�3/4 � _' 3�4"IN BEAM WEB � .__Me-1 �y� . II i � 140'F O TMV-1 I i LAV 1 WC-1 _____� WHA � � , PLUMBING FLOOR PLAN P100 scn�e: va��=r���� z UNDERFLOOR PLUMBING PLAN P100 scn�e va��=r-o�� DWH-1 Oq 1�2" CW DN i0 WC 1/7' CW �N TO WC 1• ----� \ ---� � � I I � H 1" UP i0 RTU H SCOPE OF PWMBING CONTRACT: THE PLUMBING CONTRACT SHALL CONSIST OF A COMPLEfE INSTALUTI01 COMPLIAM WITH ALL STATE AND LOCAL REQUIREMENTS THIS WORK SHALL INCLU�E BUT NOT BE LIMITED T0: > COMPLETE SANITARY DRAINAGE AND VENT SYSTEM. > COMPLETE �OMESTIC WL� & HOT WATER SUPPLY SYSTEMS INCWDING WAiER HEATERS, AN� THERMOSTA7IC CONTROLS. > PWMBING FlXTl1RES & TRIM > COORDINATION OF AN� WSTALLATION OF PWMBING CONNECTIONS TO KRCHEN EQUIPMENT, FIXTURES AN� APPLIANCES, > FUEL GAS PIPING SYSTEM > ENGINEERING OR �ESIGN SERVICES RE�UIRE� i0 COOR�INAiE BUILDING ARCHITECTURAL, STRUCTURFL, FlRE PROTECTION, ELECTRICAL AND HVAC SVSTEMS. CONTRACTOR DESIGN TASKS: THIS PROJECT IS A DESIGN & WNSTRUCT COMRACT. THE BUIL�MG ARCHITECTURE AS WELL AS THE MECHANICAL & ELECTRICAL SYSTEMS MAV CHANGE DUE TO VAWE ENGMEERING. GENERAL NOTES: 1. ALL WORK SHALL COMPLY WITH THE CURRENT E�ITION OF THE IN�IANA PWMBING CO�E. 2. THE CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED BY STATE AND LOCAL BUIL�ING OFFlCIALS. 3. THE WNiRAC70R SHALL BE RESPONSIBLE TO COOR�INAiE THE WORK OF THE UTILItt COMPANIES. OBTAIN UTILItt COMPANY PERMITS AND SCHE�ULE INSTALlATION OF SERVICES AN� ME�ERS. 4. COORDINA7E iHE WORK WITH OTHER 7RADE5 AS IT PROGRESSES. VERIFY THE E%ACT ROUGH-IN LOCATIONS OF FlXTURES WITH THE ARCHRECTURAL FLOOR PLANS FURNISH ROUGH-IN �ATA TO OTHER TRA�ES AS REOUIRED W COORDINA7E PoR PWMBING SYSiEMS AN� EQUIPMENT. 5. THE RE�UIREMEMS OF "SPEQFlCATIONS FOR ROSE & LOIS EXPRESSO" PREPARE� BY DESIGN lAYOIJ� SERVICES OF OF MYRTLE BEACH, S.C. ALONG WITH THE NOTES TO PLUMBING CONTRACTOR ON PAGE 2 SHALL APPLY TO THIS WORK. 6. ALL SANITARY �RAINAGE AND VEM PIPING � 1�8° PER 1�-0' EQUIPMENT�FlXiURES SHALL BE WNNECiED IN ACCORDANCE WIiH KES HANGERS. �0 NOi SUPPORi PIPING FROM OTHER PIPE, �UCiWORK, EfC. 9. SANRARY PIPMG BRANCHES RECEIVING �RAINAGE FROM APPLIANCES THAi UTILIZE WAiER W17H TEMPERATURES HIGHER iHAN 120'F SHALL BE CAST IRON OR POLYPROPYLENE PIPE PoR A DISTANCE OP AT LEAST 10 R. �OWNSTREAM OF THE APPLIANCE(SJ. FlX�URES RECENMG WATER WITH TEMPERATURES LESS iHAN 120'F MAY BE SCHEWLE 40 PVC. 10. GAS PIPING SHALL BE BUCK IRON WITH CAST FITfINGS AN� THREADE� JOINTS. PAINT ALL EXPOSE� GAS PIPING OUTSI�E THE BUILDING. 11. UNDERFLOOR WATER PIPING SHALL BE COPPER WITH BRAZED JOIMS, 1" RUBATEX NPE INSULATION AND PVC SHEATH OR PRE-INSUTATE� PEX PIPE �ESIGNE� FOR UNDERFLOOR APPLICAiIONS. 12. ABOVE GROUND WATER PIPING MAY BE COPPER, PVC, CPVC OR PIX WITH 1/2' INSUlATION IN ACCOR�ANCE WITH THE IN�IANA ENERGY CODE. 13. PROVIDE MAINTENANCE AND OPERATION MANUALS AND RECOR� oanwiNcs. PLAN NOTES: OCONNECT 1 1/4" CW SUPPLY TO EXISTMG CW SUPPLY DOWNSTREAM OF BACKFLOW PREVENTER AND ME�ER. OTMV AT f70" AEF.. 3/4" CW AND 14PF HW DOWN TO TMV, 3�4" 7EMPERED HW FROM 7MV. O3 1 1�7' VENT, 1�Y HW AN� CW DOWN TO LAV. O4 3/4" CW & 140'F HW TO WATER HFATER. 5 Y' VENT, 3/4" 14PF HW AND CW DOWN TO MOP BASIN, 6 1 1�7' VENi, 1�2" HW, CW & FlLiERE� CW �OWN TO BELOW COUNiER HEIGHi. EX�EN� i0 NIiCHEN E�UIPMENi AS REQUIRE� BY KITCHEN E�UIPMENT SUPPLIEft. PROVI�E � OUARTEft TURN BALL VALVE FOR EACH APPLIANCE � O7' SANITARY FROM BELOW. 1/2" HW & CW FROM BELOW. 1 EXiENO TO KITCHEN E�UIPMENT AS RE�UIRE� BY KITCHEN EQUIPMENT SUPPLIER AN� CIN PIAN REVIEWER. PROVIDE � 1/4 TURN BALL VALVE FOR EACH APPLIANCE. e>>�z° veNt, i/z• cw & Hw oowN ro eE�ow F�ooe. O9 1 1/2" VENT, 3/4" CW & 1/2" HW �OWN IN WALL TO HAN� WASH SINK EX�END 1/2" CW TO WATER FlLTER Sl1PPLIED BY KITCHEN EQUIPMENT SUPPLIER. 10 3/4" CW & 140'F HW �OWN 10 iHREE COMPARiMENi SINK. EXiEND GREASE UDEN WASTE FROM SINK TO THE FLOOR SIN C 1 1 7' VE T F OM BE OW. 11 7' OPEN SITE DRAIN. 7�4" 140'F HW DOWN TO THE DISHWASHER. ip FABRICATE SUPPORTS TO MSTALL A SECOND GAS MEiER ABOVE THE EXISTING ME�ER. IF THE EXISTING GAS PIPING IS LESS THAN 1°, REPUCE THE PIPING TO THE LOCATION SHOWN witn i' PiPE. cooRoiNntE witH tHE cns PRovioER to INSTALL 1W0 MEfERS. INSTALL NEW GAS i0 iHE WATER HEAiER, RELOCATED ROOFfOP UNIT AN� NEW ROOFfOP UNR. CONSULi OWNER ABOUi INSiAWNG PIPE BOLIARDS TO � 13 2�� OPEN SITE �RAIN, IN�IRECT CONNECT WASTE PER CIIY REQUIREMENT. REFER TO KES REQUIREMENTS FOR WAiER CONNECTIONS. SCOPE OF FlRE PROTECTION CONTRACT: THE FIRE PROTEC710N CONTRACi SHALL CONSIS7 OF A COMPLEfE WSTALlATION COMPLIAM WITH ALL STATE AND LOCAL RE4�IREMENTS. THIS WORK SHALL MCWOE BUT NOT BE LIMITE� T0: > OBiAIN HYDRAULIC �A7A FROM iHE INSiALLER OF iHE EXISTING SVSTEM. > HY�RAULIC CALWlA710NS. - > ANY NECESSARY CONNECTIONS TO KITCHEN EQUIPMENT, FI%TURES AN� APPLIANCES. CONTRACTOR DESIGN TASKS: THis aRodEcr is n oEsicN & coNsrRucr coNrancr. rHE eui�oiNc ARCHITECTURE AS WELL AS THE MECHANICAL & ELECTRICAL SYSTEMS MAY CHANGE DUE TO VAWE ENGMEERING. SUBMITfALS: SUBMIT THE FOLLOWING FOR OWNER AN� STATE APPROVAL > PRO�UCT �ATA ON ALL FlRE PROTECiION COMPONENiS. > HYDRAl1LIC CALCl1UTI0NS. > FABRICATION �RAWMGS. � � Q � � O � Q M M � w J Cp � U U � z � � � m w a J Q � � L.L.� z Q W Q U Ll z Ll w � � SCOPE DRAWINGS: Na 20754 ms a , � issueonTe oanwN ev -cNecneo ev �912�12�19 Author Checker DRAWING TITLE: PLUMBING FLOOR PLANS DRAWING NUMBER P101 PROJECTNUMBER 18023 rr p _t,t � ___ 13 � __ li