Loading...
HomeMy WebLinkAboutLighting Plan_Stamped Approved 12-03-192,077± G S F 20' SAN . SEWER ESMT .25' WATERMAIN ESMT . 15' EL E C . E S M T . 10' TE L E C O M E S M T .15' UT IL ITY ESMT .ACCESS ESMT . INST . #2011068594 ,#201168418, #20130763198' TELECOM ESMT . 15' UTILITY ESMT.S 31°29'44" W 56.50'N 69°4 8' 1 6 " E 2 7 6 . 5 5'S 20°11 '44" E 125 .39 ' S 70°0 3' 3 3 " W 23 5 . 0 0'N 20°25'02" W 125.88'N 17°33'17" W 48.94'N 17°34'49" W25.66'N 89°33'49" E 11.90' S 09°16'26" E 23.16' F.F.E. = 885.25 E 808.0'378.0 ' E G CU WALNUT CREEK DRIVE WM MH: 10 WM MH: 10 WM-2 MH: 11 WM MH: 12 S5 MH: 24 S4-IL MH: 24 S4-IL MH: 24 S2-IL MH: 12 0.5 0.1 1.4 3.0 0.1 1.4 4.8 0.3 0.1 0.9 5.5 6.0 0.0 0.1 0.2 0.3 4.1 6.8 0.2 0.2 0.3 0.4 1.1 4.1 0.7 0.3 0.6 0.8 0.8 1.7 1.4 0.3 0.2 0.2 0.5 1.3 2.0 1.9 1.5 1.3 1.0 1.1 0.9 0.5 0.3 0.7 1.5 3.0 4.2 3.8 2.3 1.8 2.1 2.6 3.0 2.9 1.1 0.5 0.5 1.1 1.3 0.3 5.4 3.3 2.6 2.3 2.8 3.6 4.4 5.5 6.8 4.9 3.0 1.0 0.4 0.3 0.7 2.2 2.4 1.7 2.1 3.0 4.3 5.4 5.7 6.1 6.3 5.2 3.6 2.3 1.0 0.3 0.2 0.4 0.9 3.3 2.4 3.4 4.6 5.8 6.1 5.8 5.5 4.2 3.0 1.8 0.9 0.5 0.3 0.2 0.5 1.3 3.9 4.1 2.8 3.5 4.4 5.1 5.0 4.3 3.0 1.8 1.0 0.6 0.4 0.3 0.3 0.3 0.2 0.2 0.5 1.3 3.0 3.4 6.2 6.5 2.4 1.2 1.5 1.9 2.5 3.0 3.4 3.4 2.6 1.7 1.1 0.7 0.5 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.4 0.7 1.4 2.1 3.9 5.8 4.6 4.0 4.5 0.6 0.6 0.8 1.3 1.8 2.3 2.4 2.1 1.6 1.2 0.9 0.7 0.6 0.5 0.4 0.4 0.4 0.4 0.3 0.2 0.1 0.2 0.4 0.6 1.0 1.8 3.2 4.5 5.3 7.6 7.8 3.8 1.7 0.8 0.9 1.1 1.4 1.6 1.6 1.5 1.5 1.3 0.9 0.8 0.7 0.6 0.5 0.4 0.4 0.0 0.1 0.1 0.2 0.4 0.8 1.5 2.8 4.3 4.9 5.1 5.5 4.8 3.0 1.8 1.4 1.2 1.2 1.2 1.2 1.3 1.7 1.7 1.3 1.3 1.0 0.7 0.5 0.4 0.3 0.0 0.0 0.1 0.1 0.2 0.6 1.4 2.7 4.2 5.6 6.2 6.2 5.4 4.1 3.0 2.4 1.9 1.4 1.2 1.1 1.3 1.5 1.6 1.6 1.6 1.0 0.7 0.5 0.4 0.3 0.0 0.0 0.1 0.4 1.2 2.4 3.7 5.1 5.9 6.4 6.3 5.7 4.3 3.3 2.4 1.6 1.3 1.2 1.5 1.8 1.5 1.5 1.2 0.8 0.6 0.4 0.3 0.1 0.2 1.1 2.6 4.4 6.9 6.5 6.0 5.6 4.8 3.5 2.3 1.5 1.1 1.1 1.3 1.4 1.4 1.7 1.1 0.7 0.5 0.4 0.3 0.1 0.4 2.6 4.6 5.5 4.3 3.6 2.9 1.9 1.2 0.9 0.8 0.9 0.9 1.0 1.2 1.0 0.7 0.5 0.4 0.2 0.3 0.9 2.3 2.4 2.0 1.3 0.8 0.6 0.6 0.6 0.6 0.7 0.8 0.7 0.6 0.4 0.3 0.2 0.4 0.6 0.6 0.5 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.4 0.3 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.3 0.1 0.2 0.2 0.3 0.3 0.3 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.3 0.3 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.0 0.1 0.0 0.0 0.0 0.00.1 0.2 0.3 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.1 0.1 Luminaire Schedule Symbol Qty Label Arrangement Lum. Lumens LLF Lum. Watts Description 1 S2-IL SINGLE 4717 0.900 53 MRM-LED-07L-SIL-2-50-70CRI-IL 1 WM-2 WALL MOUNT 4508 0.900 38 XWM-FT-LED-04-50 1 S5 SINGLE 12775 0.900 94 MRM-LED-12L-SIL-5W-50-70CRI 2 S4-IL SINGLE 25075 0.900 317 MRM-LED-36L-SIL-FT-50-70CRI-IL 3 WM WALL MOUNT 6523 0.900 53.9 XWM-FT-LED-06-50 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Calc Pts Illuminance Fc 1.79 7.8 0.0 N.A. N.A. Property Line Illuminance Fc 0.16 0.3 0.0 N.A. N.A. Paved Areas & Drives Illuminance Fc 2.79 7.6 0.5 5.58 15.20 National Lighting Vendor: For pricing and technical assistance contact: Russ Miller of CBMC INC, tel# 317-697-7510, rmiller@cbmcinc.com All electrical work shall comply with National, State, and Local codes including and not limited to the National Electric Code, NFPA 101 Life Safety Code, ASHREA and /or IECC Energy Codes. The information contained in this document is proprietary to CBMC Lighting Solutions. This document is prepared for a specific site and incorporates calculations based on data available from the client at this time. By accepting and using this document, the recipient agrees to protect its contents from further dissemination, (other than that within the organization necessary to evaluate such specification) without the written permission of CBMC Lighting Solutions. the contents of this document are not to be reproduced or copied in whole or in part without the written permission of CBMC Lighting Solutions. copyright © 2018 CBMC Lighting Solutions all rights reserved.CB15372-SITE-4 5855 KOPETSKY DR. SUITE G. | INDIANAPOLIS, IN 46217 317-780-8350| WWW.CBMCINC.COM SITE LAYOUTSEE MORE This lighting pattern represents illumination levels calculated from laboratory data taken under controlled conditions in accordance with IESNA approved methods. Actual performance of any manufacturer's luminaire may vary due to variation in electrical voltage, tolerance in lamps and LED lumen package, location adjustments, and other variable field conditions. Contractor to check and verify all dimensions on site before commencing any work shown. Valvoline Instant Oil Change Site Project No: Scale: Date: Drawn By: LP1Drawing No: SJM - 1" = 20' 9/19/19 LIGHTING NOTES: - Mounting Height = 24' Pole (Unless Noted) Building Fixture Vary See Drawing - Light Loss Factor = 0.90 - Footcandle Values Calculated @ Grade - Reflectance Values - 80/50/20 (office spaces) 50/30/20 (warehouse areas) 12/03/19