Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M003.0
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). October 31,2019 Liu, Xuegang Pages or sheets covered by this seal: I39117689 thru I39117769 My license renewal date for the state of Indiana is July 31, 2020. TG-190 Pyatt Bldrs - 190 The Grove IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE02 Truss Type Common Supported Gable Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117689 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-xVCE2jkwadBf7YKveMMmK?rHw7mVWJF22aGsDQyNweR Scale = 1:36.7 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 21 22 4x6 3x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 19-7-019-7-0 -1-0-0 1-0-0 9-9-8 9-9-8 19-7-0 9-9-8 20-7-0 1-0-0 0-6-125-5-80-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [10:0-3-8,Edge], [10:0-0-11,0-6-0], [10:0-0-5,0-0-11], [15:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.15 0.11 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.01 0.00 (loc) 11 11 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 73 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-7-0. (lb) - Max Horz 2=71(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 16, 17, 18, 14, 13, 12, 10 Max Grav All reactions 250 lb or less at joint(s) 2, 15, 16, 17, 14, 13, 10 except 18=292(LC 13), 12=292(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 9-9-8, Corner(3) 9-9-8 to 12-9-8, Exterior(2) 12-9-8 to 20-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 16, 17, 18, 14, 13, 12, 10. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE03 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117690 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-QhmcF2kZLwJWkiv5C4t?sDOSRX6jFkFBHE0QlsyNweQ Scale = 1:64.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 37 38 3x6 5x6 3x6 3x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 2x4 2x4 35-6-035-6-0 17-9-0 17-9-0 35-6-0 17-9-0 0-6-129-5-40-6-126.00 12 Plate Offsets (X,Y)-- [1:0-0-5,0-0-11], [1:0-0-11,0-6-0], [1:0-3-8,Edge], [19:0-3-8,Edge], [19:0-0-11,0-6-0], [19:0-0-5,0-0-11], [24:0-1-12,0-0-0], [25:0-0-0,0-1-12], [31:0-0-0 ,0-1-12], [32:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.16 0.11 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 19 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 10-28: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-28 REACTIONS.All bearings 35-6-0. (lb) - Max Horz 1=135(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 29, 30, 32, 33, 34, 35, 36, 27, 26, 24, 23, 22, 21, 20 Max Grav All reactions 250 lb or less at joint(s) 1, 28, 29, 30, 32, 33, 34, 35, 27, 26, 24, 23, 22, 21, 19 except 36=305(LC 13), 20=305(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=36ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-0-0 to 3-9-0, Exterior(2) 3-9-0 to 17-9-0, Corner(3) 17-9-0 to 21-3-10, Exterior(2) 21-3-10 to 35-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 29, 30, 32, 33, 34, 35, 36, 27, 26, 24, 23, 22, 21, 20. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE03A Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117691 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-utK_SOlB6ERMMrUHlnOEPQweIxRY_CuLWulzIIyNweP Scale = 1:61.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 54 53 52 51 50 49 48 4746 45 44 43 42 41 40 39 3837 36 35 34 33 32 31 30 55 56 57 58 3x6 5x6 3x6 3x8 3x6 3x8 3x6 35-6-035-6-0 -1-0-0 1-0-0 17-9-0 17-9-0 35-6-0 17-9-0 36-6-0 1-0-0 0-6-129-5-40-6-126.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-11,0-6-0], [2:0-0-5,0-0-11], [9:0-2-13,0-1-8], [21:0-2-13,0-1-8], [28:0-0-5,0-0-11], [28:0-0-11,0-6-0], [28:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.09 0.07 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.01 (loc) 29 29 28 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 208 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 15-42,14-43,16-41: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-42, 14-43, 16-41 REACTIONS.All bearings 35-6-0. (lb) - Max Horz 2=139(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 44, 45, 46, 48, 49, 50, 51, 52, 53, 54, 40, 39, 38, 36, 35, 34, 33, 32, 31, 30 Max Grav All reactions 250 lb or less at joint(s) 2, 42, 43, 44, 45, 46, 48, 49, 50, 51, 52, 53, 54, 41, 40, 28, 39, 38, 36, 35, 34, 33, 32, 31, 30 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=36ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-6-10, Exterior(2) 2-6-10 to 17-9-0, Corner(3) 17-9-0 to 21-3-10, Exterior(2) 21-3-10 to 36-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 44, 45, 46, 48, 49, 50, 51, 52, 53, 54, 40, 39, 38, 36, 35, 34, 33, 32, 31, 30. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE04 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117692 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-M4uMgkmptYZD_?2TJVvTxeTpxKoZjgBUlYVXqkyNweO Scale = 1:27.3 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x6 4x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-8-010-8-0 -1-0-0 1-0-0 5-4-0 5-4-0 10-8-0 5-4-0 11-8-0 1-0-0 0-9-04-3-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-1-3,0-1-12], [8:0-1-3,0-1-12], [10:0-0-0,0-1-12], [10:Edge,0-3-8], [16:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.10 0.02 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-8-0. (lb) - Max Horz 16=81(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 5-4-0, Corner(3) 5-4-0 to 8-4-0, Exterior(2) 8-4-0 to 11-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE05 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117693 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-qGRkt4nRerh4b9dgtCQiUr0_Jk8WS6KdzCE4MByNweN Scale = 1:52.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 40 41 42 43 2x4 2x4 4x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 25-4-025-4-0 -1-0-0 1-0-0 12-2-12 12-2-12 25-4-0 13-1-4 26-4-0 1-0-0 1-0-07-1-60-6-126.00 12 Plate Offsets (X,Y)-- [20:0-3-8,Edge], [20:0-0-11,0-6-0], [20:0-0-5,0-0-11], [32:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-9-12 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.12 0.04 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 20 20 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 25-4-0. (lb) - Max Horz 39=-95(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 39, 32, 33, 34, 35, 36, 37, 38, 20, 28, 27, 26, 25, 24, 23, 22 Max Grav All reactions 250 lb or less at joint(s) 39, 32, 30, 31, 33, 34, 35, 36, 37, 38, 29, 20, 28, 27, 26, 25, 24, 23, 22 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 12-2-12, Corner(3) 12-2-12 to 15-2-12, Exterior(2) 15-2-12 to 26-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 39, 32, 33, 34, 35, 36, 37, 38, 20, 28, 27, 26, 25, 24, 23, 22. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE05A Truss Type Common Supported Gable Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117694 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-IS?75Qo3P9pxDJCsRvyx03Y9T8TFBYMnCs_dudyNweM Scale = 1:50.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 15 28 29 30 31 2x4 2x4 4x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 25-1-025-1-0 11-11-12 11-11-12 25-1-0 13-1-4 26-1-0 1-0-0 1-1-87-1-60-6-126.00 12 Plate Offsets (X,Y)-- [13:0-0-5,0-0-11], [13:0-0-11,0-6-0], [13:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.10 0.07 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 14 14 13 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 25-1-0. (lb) - Max Horz 27=-106(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 27, 21, 23, 24, 25, 26, 19, 18, 17, 16, 15, 13 Max Grav All reactions 250 lb or less at joint(s) 27, 20, 21, 23, 24, 25, 26, 19, 18, 17, 16, 15, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-1-12 to 3-1-12, Exterior(2) 3-1-12 to 11-11-12, Corner(3) 11-11-12 to 14-11-12, Exterior(2) 14-11-12 to 26-1-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 21, 23, 24, 25, 26, 19, 18, 17, 16, 15, 13. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 13. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE06 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117695 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-mfZVImohATxorTn2_dTAZG5KpYo6w0UwRWjBR3yNweL Scale = 1:42.2 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 103x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-5-119-5-1 9-8-8 9-8-8 19-5-1 9-8-8 6-5-118.00 12 Plate Offsets (X,Y)-- [14:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.12 0.16 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 71 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-14: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-5-1. (lb) - Max Horz 1=-98(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 15, 16, 17, 12, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 1, 9, 13, 15, 16, 12, 11 except 17=263(LC 13), 10=263(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-5-12 to 3-8-8, Exterior(2) 3-8-8 to 9-8-8, Corner(3) 9-8-8 to 12-8-8, Exterior(2) 12-8-8 to 18-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 16, 17, 12, 11, 10. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE07 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117696 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Er7tW6pJxm3fSdMFYK_P6UeMUy?3fNs4fATkzWyNweK Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 23 31 32 33 34 3x6 4x8 3x4 3x6 5x6 3x6 3x6 2x4 3x6 2x4 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-5-1210-5-12 10-7-80-1-12 19-10-49-2-12 30-4-010-5-12 -1-0-0 1-0-0 7-7-11 7-7-11 15-2-0 7-6-5 22-8-5 7-6-5 30-4-0 7-7-11 0-6-128-1-120-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-11,0-6-0], [2:0-0-5,0-0-11], [5:0-1-4,0-1-8], [9:0-0-5,0-0-11], [9:0-0-11,0-6-0], [9:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.70 0.75 0.46 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.80 0.02 (loc) 9-10 9-10 9 l/defl >790 >294 n/a L/d 240 180 n/a PLATES MT20 Weight: 142 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-10,5-12: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 10-12,9-10. WEBS 1 Row at midpt 5-12 JOINTS 1 Brace at Jt(s): 17 REACTIONS.All bearings 10-7-8 except (jt=length) 9=0-3-8. (lb) - Max Horz 2=114(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 15 except 13=-157(LC 2) Max Grav All reactions 250 lb or less at joint(s) 16, 15, 14 except 2=270(LC 13), 12=1402(LC 1), 12=1402(LC 1), 9=713(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=0/397, 5-6=-608/80, 6-8=-761/69, 8-9=-1007/74 BOT CHORD 10-12=0/278, 9-10=0/826 WEBS 5-17=0/651, 10-17=0/651, 8-10=-376/127, 12-23=-998/54, 5-23=-920/27, 3-12=-466/150 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-6, Interior(1) 2-0-6 to 15-2-0, Exterior(2) 15-2-0 to 18-2-6, Interior(1) 18-2-6 to 30-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 15 except (jt=lb) 13=157. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE08 Truss Type Common Supported Gable Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117697 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-i1hFjSqyi4CW4mxR62VeehAfcLVAOwADuqCIVyyNweJ Scale = 1:37.4 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 21 22 4x6 3x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 20-0-020-0-0 -1-0-0 1-0-0 10-0-0 10-0-0 20-0-0 10-0-0 21-0-0 1-0-0 0-6-125-6-120-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [10:0-3-8,Edge], [10:0-0-11,0-6-0], [10:0-0-5,0-0-11], [15:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.17 0.12 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.02 0.00 (loc) 11 11 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 75 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-0-0. (lb) - Max Horz 2=73(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 16, 17, 18, 14, 13, 12, 10 Max Grav All reactions 250 lb or less at joint(s) 2, 15, 16, 17, 14, 13, 10 except 18=310(LC 13), 12=310(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 10-0-0, Corner(3) 10-0-0 to 13-0-0, Exterior(2) 13-0-0 to 21-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 16, 17, 18, 14, 13, 12, 10. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE09 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117698 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BEFdworaTOKNiwWdgl0tBvjqplqq7NjM7Uyr1OyNweI Scale = 1:58.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 48 47 46 45 44 43 42 41 40 3938 37 3635 34 33 32 31 30 29 28 27 26 49 50 3x6 4x6 3x6 3x4 3x6 3x4 3x6 35-1-135-1-1 17-6-8 17-6-8 35-1-1 17-6-8 8-9-46.00 12 Plate Offsets (X,Y)-- [7:0-2-13,0-1-8], [19:0-2-13,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-9-12 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.14 0.10 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 25 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 178 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-7,19-25: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 35-39: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 13-37: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-37 REACTIONS.All bearings 35-1-1. (lb) - Max Horz 1=-113(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 40, 41, 42, 43, 44, 45, 46, 47, 48, 34, 33, 32, 31, 30, 29, 28, 27, 26 Max Grav All reactions 250 lb or less at joint(s) 1, 37, 38, 40, 41, 42, 43, 44, 45, 46, 47, 36, 34, 33, 32, 31, 30, 29, 28, 27, 25 except 48=274(LC 13), 26=274(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=35ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-7-7 to 4-2-8, Exterior(2) 4-2-8 to 17-6-8, Corner(3) 17-6-8 to 21-0-10, Exterior(2) 21-0-10 to 34-5-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 40, 41, 42, 43, 44, 45, 46, 47, 48, 34, 33, 32, 31, 30, 29, 28, 27, 26. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE09A Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117699 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-fQp?87rCEhSEJ45qDTX6j6GwF996srtWM8hOaryNweH Scale = 1:16.7 1 2 3 4 5 6 7 8 2x4 4x6 2x4 2x4 8-9-18-9-1 4-4-8 4-4-8 8-9-1 4-4-8 2-2-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.48 0.16 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=153/8-9-1, 3=153/8-9-1, 4=296/8-9-1 Max Horz 1=-25(LC 7) Max Uplift 1=-9(LC 9), 3=-9(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-7-7 to 3-7-7, Exterior(2) 3-7-7 to 4-4-8, Corner(3) 4-4-8 to 7-4-8, Exterior(2) 7-4-8 to 8-1-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE010 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117700 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-TIerqNjIpJ3oVOli4frXnoI7NjRbnscuqwXJhzyNweS Scale = 1:43.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 27 28 4x6 3x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 23-6-823-6-8 -1-0-0 1-0-0 11-9-4 11-9-4 23-6-8 11-9-4 24-6-8 1-0-0 0-6-126-5-60-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [14:0-3-8,Edge], [14:0-0-11,0-6-0], [14:0-0-5,0-0-11], [22:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.07 0.02 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 15 15 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 95 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 23-6-8. (lb) - Max Horz 2=-84(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 23, 24, 25, 26, 20, 19, 14, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 2, 22, 21, 23, 24, 25, 26, 20, 19, 14, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 1-9-4, Exterior(2) 1-9-4 to 11-9-4, Corner(3) 11-9-4 to 14-9-4, Exterior(2) 14-9-4 to 24-6-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 23, 24, 25, 26, 20, 19, 14, 18, 17, 16. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE10A Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117701 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-fQp?87rCEhSEJ45qDTX6j6Gyt90zslnWM8hOaryNweH Scale = 1:46.7 1 2 3 4 5 6 7 13 12 10 9 8 16 15 14 25 26 27 28 11 29 30 4x6 3x4 4x8 3x6 3x6 2x4 3x6 3x6 3x8 2x4 3x8 3x12 2x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3-9-83-9-8 8-0-104-3-2 15-5-147-5-4 23-6-88-0-10 -1-0-0 1-0-0 5-11-5 5-11-5 11-9-4 5-9-15 17-7-3 5-9-15 23-6-8 5-11-5 0-6-126-5-60-6-126.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-11,0-6-0], [2:0-0-5,0-0-11], [4:0-1-4,0-1-8], [7:0-0-5,0-0-11], [7:0-0-11,0-6-0], [7:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.74 0.44 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.31 0.06 (loc) 8-10 8-10 7 l/defl >999 >758 n/a L/d 240 180 n/a PLATES MT20 Weight: 98 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 15 REACTIONS.All bearings 4-1-0 except (jt=length) 7=0-3-8, 11=0-3-8. (lb) - Max Horz 2=84(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 12, 13 Max Grav All reactions 250 lb or less at joint(s) 12, 13, 11 except 2=765(LC 1), 7=953(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1359/86, 3-4=-1183/102, 4-5=-1181/102, 5-6=-1422/110, 6-7=-1599/99 BOT CHORD 2-13=-24/1124, 12-13=-24/1124, 11-12=-50/1395, 10-11=-50/1395, 8-10=0/948, 7-8=-23/1347 WEBS 4-16=0/525, 8-16=0/526, 6-8=-251/106, 10-15=-25/497, 4-15=-23/453, 3-14=-305/117, 10-14=-312/117, 12-14=-303/69, 14-15=-256/74 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-9-4, Exterior(2) 11-9-4 to 14-9-4, Interior(1) 14-9-4 to 23-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12, 13. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE11 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117702 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-7cNOLTsq??a5xEg0nA3LGKoBLZXKbIGfanRy6HyNweG Scale = 1:36.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 29 28 27 26 25 24 23 22 21 20 19 18 17 30 31 4x6 3x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-9-019-9-0 -1-0-0 1-0-0 9-10-8 9-10-8 19-9-0 9-10-8 0-6-125-6-00-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [16:0-3-8,Edge], [16:0-0-11,0-6-0], [16:0-0-5,0-0-11], [23:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.07 0.03 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 86 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-9-0. (lb) - Max Horz 2=71(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 25, 26, 27, 28, 29, 21, 20, 19, 18, 17 Max Grav All reactions 250 lb or less at joint(s) 2, 23, 24, 25, 26, 27, 28, 16, 29, 22, 21, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 1-10-8, Exterior(2) 1-10-8 to 9-10-8, Corner(3) 9-10-8 to 12-10-8, Exterior(2) 12-10-8 to 19-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 25, 26, 27, 28, 29, 21, 20, 19, 18, 17. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE12 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117703 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-bpwmZptSlJiyZOECLuaapXLMgztYKkyppRAVejyNweF Scale = 1:35.8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 4x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-8-014-8-0 -1-0-0 1-0-0 7-4-0 7-4-0 14-8-0 7-4-0 15-8-0 1-0-0 0-9-05-7-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-1-3,0-1-12], [10:0-1-3,0-1-12], [12:0-0-0,0-1-12], [12:Edge,0-3-8], [20:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.10 0.03 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-8-0. (lb) - Max Horz 20=102(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 7-4-0, Corner(3) 7-4-0 to 10-4-0, Exterior(2) 10-4-0 to 15-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE13 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117704 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3?U8m9u4WcqpBYpOvb5pLluWwMC63BBy25w2B9yNweE Scale = 1:18.0 1 2 3 4 6 5 7 2x4 2x4 3x4 3x6 2x4 2x4 -1-0-0 1-0-0 4-11-8 4-11-8 0-6-123-0-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-1-5,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.07 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=43/4-11-8, 2=169/4-11-8, 6=232/4-11-8 Max Horz 2=77(LC 6) Max Uplift 5=-6(LC 8), 2=-15(LC 9), 6=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 4-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE13A Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117705 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3?U8m9u4WcqpBYpOvb5pLluX6MDe3Cfy25w2B9yNweE Scale = 1:18.0 1 2 3 4 5 8 7 6 9 2x4 2x4 3x4 3x6 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 4-11-8 4-11-8 0-6-123-0-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-1-5,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-9-12 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.12 0.04 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 4-11-8. (lb) - Max Horz 2=70(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-3-8, Exterior(2) 2-3-8 to 4-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 7, 8. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE14 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117706 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-XB2W_VviHwyfohObSIc2uyQggmYLoeQ6GlfcjcyNweD Scale = 1:18.0 1 2 3 4 6 5 7 2x4 2x4 3x4 3x6 2x4 2x4 -1-0-0 1-0-0 4-11-8 4-11-8 0-6-123-0-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-1-5,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.07 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=43/4-11-8, 2=169/4-11-8, 6=232/4-11-8 Max Horz 2=77(LC 8) Max Uplift 5=-6(LC 8), 2=-15(LC 9), 6=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 4-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss GE15 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117707 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-XB2W_VviHwyfohObSIc2uyQhxmZ0ofA6GlfcjcyNweD Scale = 1:18.8 1 2 3 4 5 8 7 6 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 8-2-58-2-5 4-1-2 4-1-2 8-2-5 4-1-2 2-8-128.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.11 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-2-5. (lb) - Max Horz 1=-38(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7, 8, 6 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-5-12 to 3-5-12, Exterior(2) 3-5-12 to 4-1-2, Corner(3) 4-1-2 to 7-1-2, Exterior(2) 7-1-2 to 7-8-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss J01 Truss Type Jack-Open Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117708 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-?NcuBrvL2E4WQrzn007HQAzsGAuDX6yFVPP9F2yNweC Scale: 1.5"=1' 1 2 3 4 2x4 1-8-151-8-15 -1-0-0 1-0-0 1-8-15 1-8-15 0-4-151-0-90-8-51-0-94.38 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=32/Mechanical, 2=148/0-3-8, 4=17/Mechanical Max Horz 2=26(LC 9) Max Uplift 3=-6(LC 6), 2=-27(LC 9) Max Grav 3=32(LC 1), 2=148(LC 1), 4=34(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss J02 Truss Type Jack-Open Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117709 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-?NcuBrvL2E4WQrzn007HQAzsGAuDX6yFVPP9F2yNweC Scale: 1.5"=1' 1 2 3 4 2x4 1-8-151-8-15 -1-0-0 1-0-0 1-8-15 1-8-15 0-4-151-0-94.38 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=32/Mechanical, 2=148/0-3-8, 4=17/Mechanical Max Horz 2=26(LC 9) Max Uplift 3=-6(LC 6), 2=-27(LC 9) Max Grav 3=32(LC 1), 2=148(LC 1), 4=34(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T01 Truss Type COMMON Qty 9 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117710 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-TaAHOBwzpXCN2?YzajeWzNWxja1kGWVOk38jnUyNweB Scale = 1:38.5 1 2 3 4 5 6 7 8 17 18 19 20 21 22 4x8 3x4 4x8 3x4 2x4 4x6 8-0-08-0-0 16-0-08-0-0 -1-0-0 1-0-0 8-0-0 8-0-0 16-0-0 8-0-0 17-0-0 1-0-0 0-9-06-1-00-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [6:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.48 0.85 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.26 0.05 (loc) 8-15 8-15 2 l/defl >999 >742 n/a L/d 240 180 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=816/0-3-8, 6=816/0-3-8 Max Horz 2=96(LC 8) Max Uplift 2=-15(LC 9), 6=-15(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-887/68, 4-6=-887/68 BOT CHORD 2-8=0/654, 6-8=0/654 WEBS 4-8=0/435 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-0-0, Exterior(2) 8-0-0 to 11-0-0, Interior(1) 11-0-0 to 17-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T01A Truss Type COMMON Qty 2 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117711 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-TaAHOBwzpXCN2?YzajeWzNWxba2JGWaOk38jnUyNweB Scale = 1:38.1 1 2 3 4 5 6 7 16 17 18 19 20 21 4x10 4x6 4x8 3x4 2x4 4x6 8-0-08-0-0 15-9-07-9-0 -1-0-0 1-0-0 8-0-0 8-0-0 15-9-0 7-9-0 0-9-06-1-00-11-08.00 12 Plate Offsets (X,Y)-- [2:0-4-13,Edge], [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.49 0.81 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.28 0.06 (loc) 7-14 7-14 2 l/defl >999 >679 n/a L/d 240 180 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x6 SPF No.2 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=746/Mechanical, 2=807/0-3-8 Max Horz 2=92(LC 8) Max Uplift 2=-16(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-843/69, 4-6=-809/73 BOT CHORD 2-7=0/636, 6-7=0/636 WEBS 4-7=0/425 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-0-0, Exterior(2) 8-0-0 to 11-0-0, Interior(1) 11-0-0 to 15-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T03 Truss Type Common Qty 5 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117712 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-ymkfcXxbarKEf97A8R9lWb23F_Ms?vcYzjuGKxyNweA Scale = 1:63.0 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 18 3x6 5x6 3x6 6x6 3x6 3x8 3x6 2x4 3x6 2x4 6x6 3x6 8-11-38-11-3 18-11-1210-0-9 26-6-137-7-1 35-6-08-11-3 -1-0-0 1-0-0 8-11-3 8-11-3 17-9-0 8-9-13 26-6-13 8-9-13 35-6-0 8-11-3 36-6-0 1-0-0 0-6-129-5-40-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-11,0-0-5], [2:0-6-0,0-0-11], [2:Edge,0-2-12], [8:0-0-11,0-0-5], [8:0-6-0,0-0-11], [8:Edge,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.68 0.92 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.66 0.15 (loc) 12-14 12-14 8 l/defl >999 >636 n/a L/d 240 180 n/a PLATES MT20 Weight: 131 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-4,6-9: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-10,3-14: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 2-14. WEBS 1 Row at midpt 7-12, 3-12 REACTIONS.(lb/size)2=1477/0-3-8, 8=1477/0-3-8 Max Horz 2=139(LC 8) Max Uplift 2=-9(LC 9), 8=-9(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2494/81, 3-5=-1617/140, 5-7=-1760/136, 7-8=-2482/90 BOT CHORD 2-14=0/2107, 12-14=0/2107, 10-12=0/2096, 8-10=0/2096 WEBS 5-12=0/942, 7-12=-782/101, 7-10=0/346, 3-12=-889/85, 3-14=0/422 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=36ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-6-10, Interior(1) 2-6-10 to 17-9-0, Exterior(2) 17-9-0 to 21-3-10, Interior(1) 21-3-10 to 36-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T03A Truss Type Common Qty 2 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117713 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-ymkfcXxbarKEf97A8R9lWb2?k_Qz?u?YzjuGKxyNweA Scale = 1:62.4 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 16 17 3x6 5x8 3x6 5x6 3x6 3x8 3x6 2x4 3x6 2x4 3x8 3x6 8-11-38-11-3 18-11-1210-0-9 26-6-137-7-1 35-6-08-11-3 8-11-3 8-11-3 17-9-0 8-9-13 26-6-13 8-9-13 35-6-0 8-11-3 36-6-0 1-0-0 0-6-129-5-40-6-126.00 12 Plate Offsets (X,Y)-- [1:0-0-11,0-0-5], [1:0-6-0,0-0-11], [7:0-0-5,0-0-11], [7:0-0-11,0-6-0], [7:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.91 0.65 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.47 0.03 (loc) 11-13 7-9 7 l/defl >999 >414 n/a L/d 240 180 n/a PLATES MT20 Weight: 129 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 6-9,2-13: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 6-11, 2-11 REACTIONS.(lb/size)1=529/Mechanical, 11=1902/0-3-8, 7=461/0-3-8 Max Horz 1=-138(LC 7) Max Uplift 7=-25(LC 9) Max Grav 1=576(LC 13), 11=1902(LC 1), 7=533(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-723/56, 2-4=0/524, 4-6=0/661, 6-7=-494/100 BOT CHORD 1-13=-7/571, 11-13=-7/571, 9-11=-44/345, 7-9=-44/345 WEBS 4-11=-903/56, 6-11=-839/101, 6-9=0/352, 2-11=-956/85, 2-13=0/431 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=36ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-0-12 to 3-7-6, Interior(1) 3-7-6 to 17-9-0, Exterior(2) 17-9-0 to 21-3-10, Interior(1) 21-3-10 to 36-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T03B Truss Type Common Qty 4 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117714 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-QyI1psyDL9S5HJiMh8h_2obA1NmCkLFhBNdpsNyNwe9 Scale = 1:61.8 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 3x6 5x8 3x6 5x6 3x6 3x8 3x6 2x4 3x6 2x4 5x6 3x6 8-11-38-11-3 18-11-1210-0-9 26-6-137-7-1 35-6-08-11-3 8-11-3 8-11-3 17-9-0 8-9-13 26-6-13 8-9-13 35-6-0 8-11-3 0-6-129-5-40-6-126.00 12 Plate Offsets (X,Y)-- [1:0-0-11,0-0-5], [1:0-6-0,0-0-11], [7:0-0-11,0-0-5], [7:0-6-0,0-0-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.94 0.65 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.51 0.03 (loc) 7-8 7-8 7 l/defl >999 >386 n/a L/d 240 180 n/a PLATES MT20 Weight: 128 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 6-8,2-12: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-10, 6-10, 2-10 REACTIONS.(lb/size)1=527/Mechanical, 10=1911/0-3-8, 7=392/Mechanical Max Horz 1=-135(LC 7) Max Grav 1=575(LC 13), 10=1911(LC 1), 7=463(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-721/54, 2-4=0/529, 4-6=0/666, 6-7=-472/98 BOT CHORD 1-12=-8/570, 10-12=-8/570, 8-10=-42/351, 7-8=-42/351 WEBS 4-10=-906/57, 6-10=-853/102, 6-8=0/358, 2-10=-957/85, 2-12=0/431 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=36ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-0-12 to 3-7-6, Interior(1) 3-7-6 to 17-9-0, Exterior(2) 17-9-0 to 21-3-10, Interior(1) 21-3-10 to 35-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T03C Truss Type Roof Special Qty 4 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117715 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-u9rP1Cyr6SayvTHYFsCDb08Lun50TocrQ1NNOpyNwe8 Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 16 15 14 11 10 13 12 17 18 19 20 3x6 5x8 3x6 5x6 3x6 2x4 4x6 4x6 5x6 5x6 3x6 2x4 8x8 3x6 5x12 3x6 8-11-38-11-3 18-11-1210-0-9 19-1-80-1-12 22-1-83-0-0 26-6-134-5-5 35-6-08-11-3 8-11-3 8-11-3 17-9-0 8-9-13 19-1-8 1-4-8 22-1-8 3-0-0 26-6-13 4-5-5 35-6-0 8-11-3 0-6-129-5-40-6-122-0-06.00 12 Plate Offsets (X,Y)-- [1:0-0-11,0-0-5], [1:0-6-0,0-0-11], [9:0-6-0,0-0-11], [9:0-0-11,0-0-5], [11:0-3-0,0-3-0], [14:0-2-12,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.93 0.74 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.49 0.04 (loc) 14-16 14-16 14 l/defl >999 >459 n/a L/d 240 180 n/a PLATES MT20 Weight: 151 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 6-11,11-14: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud *Except* 2-14,4-14: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 10-11. 6-0-0 oc bracing: 13-14 10-0-0 oc bracing: 11-12 WEBS 1 Row at midpt 2-14, 4-14 JOINTS 1 Brace at Jt(s): 13, 12 REACTIONS.(lb/size)1=744/Mechanical, 9=643/Mechanical, 14=1443/0-3-8 Max Horz 1=-135(LC 7) Max Uplift 1=-16(LC 9), 9=-21(LC 9) Max Grav 1=752(LC 13), 9=651(LC 14), 14=1443(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1099/118, 6-8=-474/163, 8-9=-854/131 BOT CHORD 1-16=-19/902, 14-16=-19/902, 9-10=-25/681, 13-14=-722/71, 12-13=0/337, 6-12=-10/560 WEBS 2-16=0/437, 2-14=-944/87, 4-14=-320/66, 6-13=-597/41, 10-12=-20/749, 8-12=-419/72 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=36ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-0-12 to 3-7-6, Interior(1) 3-7-6 to 17-9-0, Exterior(2) 17-9-0 to 21-3-10, Interior(1) 21-3-10 to 35-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T05 Truss Type Common Qty 4 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117716 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-MLPnEYzTtmipWcslpZjS7DgazBObCIF_fh6wwFyNwe7 Scale = 1:46.9 1 2 3 4 5 6 7 8 11 10 9 19 20 21 22 23 24 5x12 5x6 3x6 3x6 2x4 4x6 3x6 2x4 6x8 7-8-77-8-7 16-9-19-0-10 25-4-08-6-15 -1-0-0 1-0-0 5-8-13 5-8-13 12-2-12 6-5-15 18-8-11 6-5-15 25-4-0 6-7-5 26-4-0 1-0-0 1-0-07-1-60-6-126.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [7:0-0-5,0-0-11], [7:0-0-11,0-6-0], [7:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.65 0.91 0.38 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.39 -0.69 0.06 (loc) 9-11 9-11 7 l/defl >780 >441 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 5-8: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud SLIDER Left 2x8 SP 2400F 2.0E 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS.(lb/size)2=1152/0-3-8, 7=1147/0-3-8 Max Horz 2=-91(LC 7) Max Uplift 2=-10(LC 9), 7=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1681/171, 4-5=-1536/111, 5-6=-1687/110, 6-7=-1864/81 BOT CHORD 2-11=0/1418, 9-11=0/1051, 7-9=-3/1597 WEBS 5-11=0/527, 5-9=0/699, 6-9=-354/118 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-2-12, Exterior(2) 12-2-12 to 15-2-12, Interior(1) 15-2-12 to 26-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T05A Truss Type Common Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117717 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-qXzASu_5e4qg8mRxNHEhgRDljbjgxjQ8tLsUTiyNwe6 Scale = 1:46.4 1 2 3 4 5 6 7 10 9 8 18 19 20 21 22 23 5x12 5x6 3x6 3x6 2x4 4x6 3x6 2x4 6x6 7-8-77-8-7 16-9-19-0-10 25-4-08-6-15 -1-0-0 1-0-0 5-8-13 5-8-13 12-2-12 6-5-15 18-8-11 6-5-15 25-4-0 6-7-5 1-0-07-1-60-6-126.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [7:0-0-11,0-0-5], [7:0-6-0,0-0-11], [7:Edge,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.65 0.92 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.39 -0.69 0.06 (loc) 8-10 8-10 7 l/defl >785 >443 n/a L/d 240 180 n/a PLATES MT20 Weight: 92 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 5-7: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud SLIDER Left 2x8 SP 2400F 2.0E 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS.(lb/size)2=1154/0-3-8, 7=1086/Mechanical Max Horz 2=90(LC 8) Max Uplift 2=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1683/170, 4-5=-1538/111, 5-6=-1693/122, 6-7=-1871/93 BOT CHORD 2-10=-11/1419, 8-10=0/1053, 7-8=-15/1604 WEBS 5-10=0/527, 5-8=0/705, 6-8=-358/118 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-2-12, Exterior(2) 12-2-12 to 15-2-12, Interior(1) 15-2-12 to 25-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T05B Truss Type Common Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117718 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-qXzASu_5e4qg8mRxNHEhgRDoZbi6xhH8tLsUTiyNwe6 Scale = 1:45.9 1 2 3 4 5 9 8 7 6 10 11 12 13 14 15 3x4 4x6 3x6 3x6 4x6 3x6 2x4 5x6 3x6 7-5-77-5-7 16-6-19-0-10 25-1-08-6-15 5-5-13 5-5-13 11-11-12 6-5-15 18-5-11 6-5-15 25-1-0 6-7-5 1-1-87-1-60-6-126.00 12 Plate Offsets (X,Y)-- [5:0-0-5,0-0-11], [5:0-0-11,0-6-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.47 0.96 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.33 -0.54 0.07 (loc) 6-8 6-8 5 l/defl >908 >549 n/a L/d 240 180 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 2-9 REACTIONS.(lb/size)5=1068/Mechanical, 9=1075/Mechanical Max Horz 9=-103(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1530/119, 3-4=-1671/122, 4-5=-1853/92 BOT CHORD 8-9=-8/1367, 6-8=0/1018, 5-6=-15/1577 WEBS 3-8=0/525, 3-6=0/719, 4-6=-357/128, 2-9=-1487/37 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 11-11-12, Exterior(2) 11-11-12 to 14-11-12, Interior(1) 14-11-12 to 25-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T05C Truss Type Common Qty 3 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117719 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-IkXYfE?kPNyXmw?7w_lwDelzJ?2Lg8XH6?b1?8yNwe5 Scale = 1:45.9 1 2 3 4 5 9 8 7 6 10 11 12 13 14 15 3x4 4x6 3x6 3x6 4x6 3x6 2x4 5x6 3x6 7-5-77-5-7 16-6-19-0-10 25-1-08-6-15 5-5-13 5-5-13 11-11-12 6-5-15 18-5-11 6-5-15 25-1-0 6-7-5 1-1-87-1-60-6-126.00 12 Plate Offsets (X,Y)-- [5:0-0-5,0-0-11], [5:0-0-11,0-6-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.47 0.96 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.33 -0.54 0.07 (loc) 6-8 6-8 5 l/defl >908 >549 n/a L/d 240 180 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 2-9 REACTIONS.(lb/size)5=1068/Mechanical, 9=1075/Mechanical Max Horz 9=-103(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1530/119, 3-4=-1671/122, 4-5=-1853/92 BOT CHORD 8-9=-8/1367, 6-8=0/1018, 5-6=-15/1577 WEBS 3-8=0/525, 3-6=0/719, 4-6=-357/128, 2-9=-1487/37 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 11-11-12, Exterior(2) 11-11-12 to 14-11-12, Interior(1) 14-11-12 to 25-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T05D Truss Type Roof Special Qty 3 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117720 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-mw5wta0MAh4ON4aJUhG9lsI5gOSlPdtQLfLaXayNwe4 Scale = 1:49.4 1 2 3 4 5 6 13 12 11 10 9 8 7 14 15 16 17 18 19 3x4 4x6 3x6 4x6 2x4 3x6 4x6 3x6 4x10 3x6 3x6 3x12 7-5-77-5-7 16-6-19-0-10 20-3-03-8-15 20-3-80-0-8 24-11-24-7-10 5-5-13 5-5-13 11-11-12 6-5-15 20-3-8 8-3-12 24-11-2 4-7-10 26-1-0 1-1-14 1-1-87-1-67-8-101-2-150-7-46.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.69 0.76 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.47 0.03 (loc) 10-12 10-12 9 l/defl >959 >517 n/a L/d 240 180 n/a PLATES MT20 Weight: 102 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 4-8: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 9-10. WEBS 1 Row at midpt 3-10, 2-13 REACTIONS.(lb/size)7=159/Mechanical, 13=853/Mechanical, 9=1189/0-3-8 Max Horz 13=-113(LC 7) Max Uplift 7=-39(LC 9) Max Grav 7=187(LC 14), 13=853(LC 1), 9=1189(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1131/110, 3-4=-761/82 BOT CHORD 12-13=0/1034, 10-12=0/637, 4-9=-1158/50 WEBS 3-12=0/561, 4-10=0/661, 2-13=-1106/23 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 11-11-12, Exterior(2) 11-11-12 to 14-11-12, Interior(1) 14-11-12 to 26-1-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T05E Truss Type Roof Special Qty 3 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117721 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-mw5wta0MAh4ON4aJUhG9lsI70OWePWKQLfLaXayNwe4 Scale = 1:49.4 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 3x6 2x4 3x12 2x4 3x8 3x4 3x6 4x6 3x6 4x6 4x6 4x6 5-10-05-10-0 11-0-85-2-8 11-4-80-4-0 18-3-116-11-3 24-11-26-7-7 5-10-0 5-10-0 11-4-8 5-6-8 11-11-12 0-7-4 18-3-11 6-3-15 24-11-2 6-7-7 26-1-0 1-1-14 1-1-87-1-67-8-101-2-150-7-46.00 12 Plate Offsets (X,Y)-- [4:0-3-0,Edge], [6:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.54 0.51 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.13 0.01 (loc) 9-10 9-10 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 103 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-10: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)13=407/Mechanical, 11=1071/0-3-8, 8=571/Mechanical Max Horz 13=-113(LC 7) Max Uplift 13=-12(LC 9), 8=-39(LC 9) Max Grav 13=407(LC 1), 11=1071(LC 1), 8=601(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-444/84, 5-6=-605/76, 6-8=-543/116, 1-13=-355/82 BOT CHORD 11-12=0/336, 10-11=0/353, 3-11=-410/29, 9-10=0/469 WEBS 2-11=-477/50, 5-9=0/269, 6-9=0/325, 5-10=-554/55 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 11-11-12, Exterior(2) 11-11-12 to 14-11-12, Interior(1) 14-11-12 to 26-1-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 8. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T07 Truss Type Common Qty 7 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117722 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-E6fI4w0_x?DF?E9W2PnOI3rG_orI84aaaJ4831yNwe3 Scale = 1:52.9 1 2 3 4 5 6 7 8 11 10 9 12 13 14 15 16 17 3x6 4x8 3x6 3x8 3x8 3x6 2x4 3x6 2x4 3x8 10-5-1210-5-12 19-10-49-4-8 30-4-010-5-12 -1-0-0 1-0-0 7-7-11 7-7-11 15-2-0 7-6-5 22-8-5 7-6-5 30-4-0 7-7-11 0-6-128-1-120-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [8:0-0-5,0-0-11], [8:0-0-11,0-6-0], [8:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.65 0.55 0.42 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.69 0.02 (loc) 9-11 8-9 8 l/defl >834 >341 n/a L/d 240 180 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 7-9,3-11: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-11 REACTIONS.(lb/size)2=300/0-3-8, 11=1623/0-3-8, 8=735/0-3-8 Max Horz 2=114(LC 8) Max Uplift 2=-17(LC 9) Max Grav 2=350(LC 13), 11=1623(LC 1), 8=735(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=0/438, 5-7=-830/98, 7-8=-1085/79 BOT CHORD 8-9=0/898 WEBS 5-9=0/801, 7-9=-450/147, 5-11=-1063/58, 3-11=-479/145 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-6, Interior(1) 2-0-6 to 15-2-0, Exterior(2) 15-2-0 to 18-2-6, Interior(1) 18-2-6 to 30-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T07A Truss Type Common Qty 3 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117723 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:12:59 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-jJDgHG1ciIL6dOkic6JdqHNRVCBatXrjozqhcTyNwe2 Scale = 1:52.9 1 2 3 4 5 6 7 8 11 10 9 12 13 14 15 16 17 3x6 4x8 3x6 4x8 3x8 3x6 2x4 3x6 2x4 4x8 10-5-1210-5-12 19-10-49-4-8 30-4-010-5-12 -1-0-0 1-0-0 7-7-11 7-7-11 15-2-0 7-6-5 22-8-5 7-6-5 30-4-0 7-7-11 0-6-128-1-120-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [8:0-0-5,0-0-11], [8:0-0-11,0-6-0], [8:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.67 0.54 0.42 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.66 0.02 (loc) 9-11 2-11 9 l/defl >837 >356 n/a L/d 240 180 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 7-9,3-11: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-9 REACTIONS.(lb/size)2=806/0-3-8, 9=1625/0-3-8, 8=227/0-3-8 Max Horz 2=114(LC 8) Max Uplift 2=-15(LC 9) Max Grav 2=806(LC 1), 9=1625(LC 1), 8=277(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1100/69, 3-5=-824/91, 5-7=0/437 BOT CHORD 2-11=0/889 WEBS 5-9=-1059/57, 7-9=-485/148, 5-11=0/794, 3-11=-444/144 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-6, Interior(1) 2-0-6 to 15-2-0, Exterior(2) 15-2-0 to 18-2-6, Interior(1) 18-2-6 to 30-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T07B Truss Type Common Qty 6 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117724 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BVn3Vc2EScTzEXJu9qqsNUwYNcTtctlt1dZE8vyNwe1 Scale = 1:53.7 1 2 3 4 5 6 7 8 12 11 10 9 13 14 15 16 17 18 3x6 4x8 3x6 3x8 3x6 3x6 2x4 3x6 3x6 2x4 3x8 6-5-56-5-5 12-9-46-3-15 19-10-47-1-0 30-4-010-5-12 -1-0-0 1-0-0 6-5-5 6-5-5 15-2-0 8-8-11 22-8-5 7-6-5 30-4-0 7-7-11 0-6-128-1-120-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [8:0-0-5,0-0-11], [8:0-0-11,0-6-0], [8:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.91 0.79 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.32 -0.86 0.02 (loc) 8-9 8-9 8 l/defl >645 >244 n/a L/d 240 180 n/a PLATES MT20 Weight: 108 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-9: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 9-11. WEBS 1 Row at midpt 5-11 REACTIONS.(lb/size)2=394/0-3-8, 11=1625/0-3-8, 8=592/0-3-8 Max Horz 2=114(LC 8) Max Uplift 2=-23(LC 9) Max Grav 2=440(LC 13), 11=1625(LC 1), 8=612(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-448/40, 3-5=0/505, 5-7=-559/100, 7-8=-818/80 BOT CHORD 2-12=-36/337, 11-12=-36/337, 8-9=0/665 WEBS 3-12=0/281, 3-11=-698/94, 5-11=-1128/59, 5-9=0/754, 7-9=-462/145 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-6, Interior(1) 2-0-6 to 15-2-0, Exterior(2) 15-2-0 to 18-2-6, Interior(1) 18-2-6 to 30-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T07C Truss Type Common Qty 9 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117725 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BVn3Vc2EScTzEXJu9qqsNUwdpcWKc0Wt1dZE8vyNwe1 Scale = 1:53.4 1 2 3 4 5 6 7 8 9 12 11 10 13 14 15 16 17 18 3x6 4x6 3x6 6x8 3x8 3x6 2x4 3x6 2x4 6x8 10-5-1210-5-12 19-10-49-4-8 30-4-010-5-12 -1-0-0 1-0-0 7-7-11 7-7-11 15-2-0 7-6-5 22-8-5 7-6-5 30-4-0 7-7-11 31-4-0 1-0-0 0-6-128-1-120-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-11,0-0-5], [2:0-6-0,0-0-11], [8:0-0-11,0-0-5], [8:0-6-0,0-0-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.63 0.64 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.37 -0.72 0.08 (loc) 10-12 2-12 8 l/defl >977 >501 n/a L/d 240 180 n/a PLATES MT20 Weight: 107 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 7-10,3-12: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1364/0-3-8, 8=1364/0-3-8 Max Horz 2=-114(LC 7) Max Uplift 2=-12(LC 9), 8=-12(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2265/97, 3-5=-1995/118, 5-7=-1995/118, 7-8=-2265/97 BOT CHORD 2-12=-7/1912, 10-12=0/1300, 8-10=-10/1912 WEBS 5-10=0/766, 7-10=-411/142, 5-12=0/766, 3-12=-411/142 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-6, Interior(1) 2-0-6 to 15-2-0, Exterior(2) 15-2-0 to 18-2-6, Interior(1) 18-2-6 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T07D Truss Type MONOPITCH Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117726 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:01 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-fhKRix3sDwbpshu5jXL5wiTpE0viLSq0GHJogLyNwe0 Scale = 1:42.6 1 2 3 4 5 6 9 8 7 10 113x6 3x4 3x8 3x8 3x4 2x4 7-0-117-0-11 14-3-87-2-13 14-4-80-1-0 -1-0-0 1-0-0 7-0-11 7-0-11 14-3-8 7-2-13 14-4-0 0-0-8 0-6-127-8-120-3-86.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.52 0.44 0.33 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.16 0.02 (loc) 8-9 8-9 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS.(lb/size)8=566/Mechanical, 2=632/0-3-8 Max Horz 2=208(LC 8) Max Uplift 8=-1(LC 9), 2=-10(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-798/47 BOT CHORD 2-9=-136/628, 8-9=-136/628 WEBS 3-9=0/332, 3-8=-695/81 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 14-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T07E Truss Type MONOPITCH Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117727 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-7uupwH3U_DjgUrTHHFsKSv?_lPEt4v?9Ux2LCoyNwe? Scale = 1:42.6 1 2 3 4 5 8 76 9 103x6 3x4 3x8 3x8 3x4 2x4 7-0-117-0-11 14-3-87-2-13 14-4-80-1-0 7-0-11 7-0-11 14-3-8 7-2-13 14-4-0 0-0-8 0-6-127-8-120-3-86.00 12 Plate Offsets (X,Y)-- [1:0-0-5,0-0-11], [1:0-0-11,0-6-0], [1:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.54 0.44 0.33 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.16 0.02 (loc) 7-8 1-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-7 REACTIONS.(lb/size)7=568/Mechanical, 1=560/0-3-8 Max Horz 1=206(LC 6) Max Uplift 7=-2(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-784/57 BOT CHORD 1-8=-137/636, 7-8=-137/636 WEBS 2-8=0/334, 2-7=-704/83 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 14-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T08 Truss Type Common Qty 2 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117728 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-7uupwH3U_DjgUrTHHFsKSv?09P854wm9Ux2LCoyNwe? Scale = 1:36.1 1 2 3 4 5 6 7 8 9 10 11 4x6 4x8 5x12 2x4 2x4 4x8 10-0-010-0-0 20-0-010-0-0 -1-0-0 1-0-0 5-0-11 5-0-11 10-0-0 4-11-5 14-11-5 4-11-5 20-0-0 5-0-11 0-6-125-6-120-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [6:0-3-8,Edge], [6:0-0-11,0-6-0], [6:0-0-5,0-0-11], [7:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.38 0.81 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.55 0.04 (loc) 6-7 6-7 6 l/defl >999 >428 n/a L/d 240 180 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=859/0-3-8, 6=786/0-3-8 Max Horz 2=72(LC 8) Max Uplift 2=-17(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1252/97, 3-4=-958/65, 4-5=-959/73, 5-6=-1257/109 BOT CHORD 2-7=-37/1053, 6-7=-39/1061 WEBS 4-7=0/556, 5-7=-329/116, 3-7=-321/112 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 10-0-0, Exterior(2) 10-0-0 to 13-0-0, Interior(1) 13-0-0 to 19-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T10 Truss Type Common Qty 7 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117729 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-b4SB7d47lXrX5?2TryNZ?7YBapW1pNgJjbovlEyNwe_ Scale = 1:42.2 1 2 3 4 5 6 7 10 9 8 11 12 13 14 15 16 4x6 4x8 3x6 3x6 2x4 3x6 2x4 4x8 8-0-108-0-10 15-5-147-5-4 23-6-88-0-10 -1-0-0 1-0-0 5-11-5 5-11-5 11-9-4 5-9-15 17-7-3 5-9-15 23-6-8 5-11-5 24-6-8 1-0-0 0-6-126-5-60-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [6:0-0-5,0-0-11], [6:0-0-11,0-6-0], [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.41 0.70 0.30 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.32 0.06 (loc) 8-10 6-8 6 l/defl >999 >868 n/a L/d 240 180 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1051/0-3-8, 6=1051/0-3-8 Max Horz 2=84(LC 8) Max Uplift 2=-15(LC 9), 6=-15(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1675/78, 3-4=-1475/98, 4-5=-1475/98, 5-6=-1675/78 BOT CHORD 2-10=-7/1402, 8-10=0/961, 6-8=-10/1402 WEBS 4-8=0/557, 5-8=-303/114, 4-10=0/557, 3-10=-303/114 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-9-4, Exterior(2) 11-9-4 to 14-9-4, Interior(1) 14-9-4 to 24-6-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T11 Truss Type Common Qty 7 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117730 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3G0ZLz5lWrzOj9dgOfuoXK5LqDqeYpbSyFXSGgyNwdz Scale = 1:35.7 1 2 3 4 5 6 7 8 9 10 11 4x6 5x6 5x12 2x4 2x4 5x6 9-10-89-10-8 19-9-09-10-8 -1-0-0 1-0-0 5-9-13 5-9-13 9-10-8 4-0-11 13-11-3 4-0-11 19-9-0 5-9-13 0-6-125-6-00-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [6:0-0-11,0-6-0], [6:0-0-5,0-0-11], [7:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.81 0.33 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.56 0.04 (loc) 6-7 6-7 6 l/defl >999 >418 n/a L/d 240 180 n/a PLATES MT20 Weight: 65 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=852/0-3-8, 6=780/Mechanical Max Horz 2=71(LC 8) Max Uplift 2=-18(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1214/89, 3-4=-942/68, 4-5=-944/76, 5-6=-1225/101 BOT CHORD 2-7=-25/1014, 6-7=-26/1030 WEBS 4-7=0/595, 5-7=-325/113, 3-7=-306/109 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-10-8, Exterior(2) 9-10-8 to 12-10-8, Interior(1) 12-10-8 to 19-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T13 Truss Type MONOPITCH Qty 7 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117731 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3G0ZLz5lWrzOj9dgOfuoXK5MZDzXYugSyFXSGgyNwdz Scale = 1:18.0 1 2 3 4 5 2x4 3x4 3x6 2x4 4-11-84-11-8 -1-0-0 1-0-0 4-10-0 4-10-0 4-11-8 0-1-8 0-6-123-0-82-9-00-3-83-0-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-1-5,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.33 0.24 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.07 0.00 (loc) 2-4 2-4 4 l/defl >999 >788 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=264/0-3-8, 4=178/0-1-8 Max Horz 2=77(LC 6) Max Uplift 2=-24(LC 9), 4=-3(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss T14 Truss Type MONOPITCH Qty 7 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117732 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-XSayYJ6NH85FLJBsyNP14YdXEdK_HLwcBvH?o7yNwdy Scale = 1:19.6 1 2 3 5 4 6 3x4 3x4 3x8 2x4 4-9-104-9-10 -1-1-14 1-1-14 4-8-2 4-8-2 4-9-10 0-1-8 0-11-70-8-03-7-120-3-83-4-40-3-83-7-126.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.33 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.04 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=270/0-1-8, 4=169/0-1-8 Max Horz 5=97(LC 8) Max Uplift 5=-23(LC 9), 4=-16(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-1-14 to 1-10-2, Interior(1) 1-10-2 to 4-7-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5, 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117733 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-XSayYJ6NH85FLJBsyNP14YdRpdAvHCwcBvH?o7yNwdy Scale = 1:36.6 1 2 3 5 4 6 7 8 9 10 11 12 4x6 3x8 3x8 4x8 4x8 5-4-65-4-6 10-7-105-3-5 16-0-05-4-6 8-0-0 8-0-0 16-0-0 8-0-0 0-9-06-1-00-9-08.00 12 Plate Offsets (X,Y)-- [1:0-0-6,0-0-8], [1:0-0-11,0-4-9], [1:Edge,0-1-1], [3:0-0-6,0-0-8], [3:0-0-11,0-4-9], [3:Edge,0-1-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.74 0.80 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.12 0.02 (loc) 1-5 1-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=3105/0-3-8, 3=2456/0-3-8 Max Horz 1=-91(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3526/0, 2-3=-3265/0 BOT CHORD 1-5=0/2752, 4-5=0/1839, 3-4=0/2540 WEBS 2-4=0/1624, 2-5=-1/2110 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-8-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 638 lb down and 29 lb up at 0-6-0, 631 lb down and 33 lb up at 2-6-0, 631 lb down and 33 lb up at 4-6-0, 631 lb down and 33 lb up at 6-6-0, 443 lb down at 8-6-0, 443 lb down at 10-6-0, and 443 lb down at 12-6-0, and 443 lb down at 14-6-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 1-3=-20 Concentrated Loads (lb) Vert: 4=-443(F) 6=-638(F) 7=-631(F) 8=-631(F) 9=-631(F) 10=-443(F) 11=-443(F) 12=-443(F) October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss TG01A Truss Type Roof Special Girder Qty 1 Ply 2 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117734 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-?f8Klf6?2SD6yTm2W4xGdlAYk1UF0cUlPZ0ZLZyNwdx Scale = 1:41.0 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 17 18 19 20 5x8 5x12 6x8 3x12 4x10 4x8 3x6 10x10 6x6 3x6 2x4 5-1-05-1-0 10-7-65-6-7 14-5-33-9-13 16-5-42-0-1 20-0-83-7-4 8-0-0 8-0-0 14-5-3 6-5-3 16-5-4 2-0-1 20-0-8 3-7-4 0-9-01-9-96-1-00-4-38.00 12 3.10 12 Plate Offsets (X,Y)-- [1:0-1-8,0-2-0], [5:1-0-0,0-0-3], [5:1-0-11,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.99 0.92 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.57 0.09 (loc) 7-8 7-8 5 l/defl >931 >412 n/a L/d 240 180 n/a PLATES MT20 Weight: 194 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 1-2: 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* 5-9: 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 2-8,3-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=4285/0-3-8, 5=5819/0-6-7 Max Horz 1=-90(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-6241/0, 2-3=-8393/0, 3-4=-16108/0, 4-5=-17032/0 BOT CHORD 1-10=0/4992, 8-10=0/4065, 7-8=0/15434, 6-7=0/16398, 5-6=0/16398 WEBS 2-10=0/1956, 2-8=0/6625, 3-8=-9065/0, 3-7=0/2164, 4-7=-843/0, 4-6=0/1033 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 22 lb down and 13 lb up at 17-4-15 on top chord, and 393 lb down and 20 lb up at 0-6-0, 387 lb down and 24 lb up at 2-6-0, 387 lb down and 24 lb up at 4-6-0, 833 lb down at 6-6-0, 833 lb down at 8-6-0, 833 lb down at 10-6-0, 1055 lb down at 12-6-0, 1055 lb down at 14-6-0, 647 lb down at 15-10-8, 1055 lb down at 16-6-0, and at 17-4-15, and 1055 lb down at 18-6-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 1-5=-20 Continued on page 2 October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss TG01A Truss Type Roof Special Girder Qty 1 Ply 2 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117734 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:06 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-?f8Klf6?2SD6yTm2W4xGdlAYk1UF0cUlPZ0ZLZyNwdx LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 8=-833(B) 7=-1055(B) 6=-1055(B) 12=-393(B) 13=-387(B) 14=-387(B) 15=-833(B) 16=-833(B) 17=-1055(B) 18=-647(F) 20=-1055(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss TG01B Truss Type Roof Special Girder Qty 1 Ply 2 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117735 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Uriiz?7dpmLzacLE4oSV9zjwqQ0VlFPveDm6t?yNwdw Scale = 1:9.7 1 2 3 5 4 6 7 84x6 2x4 3x6 1-9-121-9-12 4-3-82-5-12 1-9-12 1-9-12 4-3-8 2-5-12 0-7-41-4-113.10 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.13 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 1 1 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=667/Mechanical, 4=1069/0-9-7 Max Horz 4=25(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) 2-ply truss to be connected together as follows: Top chords connected with 10d (0.131"x3") nails as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected with 10d (0.131"x3") nails as follows: 2x8 - 2 rows staggered at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 9 lb down and 13 lb up at 2-10-8 on top chord, and 702 lb down at 0-5-12, and 703 lb down at 2-5-12, and at 2-10-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 1-4=-80, 1-3=-20 Concentrated Loads (lb) Vert: 6=-702(B) 7=-703(B) October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117736 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Uriiz?7dpmLzacLE4oSV9zjrhQqAl3iveDm6t?yNwdw Scale = 1:36.0 1 2 3 4 5 8 7 691011121314 15 16 17 4x10 4x8 4x8 4x6 6x6 2x4 8x8 2x4 6-8-26-8-2 12-10-146-2-13 19-7-06-8-2 5-1-7 5-1-7 9-9-8 4-8-1 14-5-9 4-8-1 19-7-0 5-1-7 0-6-125-5-80-6-126.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-11], [5:0-1-1,0-1-15] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.46 0.94 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.25 0.05 (loc) 1-8 1-8 5 l/defl >999 >919 n/a L/d 240 180 n/a PLATES MT20 Weight: 167 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* 5-7: 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=3595/0-3-8, 5=4217/0-3-8 Max Horz 1=67(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5539/0, 2-3=-5406/0, 3-4=-5691/0, 4-5=-5823/0 BOT CHORD 1-8=0/4822, 6-8=0/3477, 5-6=0/5069 WEBS 3-6=0/2978, 3-8=0/2490 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-8-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 556 lb down at 1-1-0, 556 lb down at 3-1-0, 555 lb down at 5-1-0, 555 lb down at 7-1-0, 555 lb down at 9-1-0, 555 lb down at 11-1-0, 732 lb down and 28 lb up at 13-1-0, 732 lb down and 28 lb up at 15-1-0, and 732 lb down and 28 lb up at 17-1-0, and 739 lb down and 25 lb up at 19-1-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 1-5=-20 Concentrated Loads (lb) Vert: 6=-732(F) 9=-556(F) 10=-556(F) 11=-555(F) 12=-555(F) 13=-555(F) 14=-555(F) 15=-732(F) 16=-732(F) 17=-739(F) October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss TG04 Truss Type Common Girder Qty 1 Ply 2 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117737 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-y1F4AL8Fa3TqCmwRdVzkiAF_rqAbUUq2tsVgPRyNwdv Scale = 1:26.6 1 2 3 456 7 8 4x6 4x10 4x8 4x8 5-4-05-4-0 10-8-05-4-0 5-4-0 5-4-0 10-8-0 5-4-0 0-9-04-3-110-9-08.00 12 Plate Offsets (X,Y)-- [1:0-0-6,0-0-8], [1:0-0-11,0-4-9], [1:Edge,0-1-1], [3:0-0-6,0-0-8], [3:0-0-11,0-4-9], [3:Edge,0-1-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.63 0.87 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.12 0.02 (loc) 1-4 1-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=2969/0-3-8, 3=3118/0-3-8 Max Horz 1=-62(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3255/0, 2-3=-3256/0 BOT CHORD 1-4=0/2557, 3-4=0/2557 WEBS 2-4=0/3472 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1048 lb down at 1-6-0, 1048 lb down at 3-6-0, 1048 lb down at 5-6-0, and 1048 lb down at 7-6-0, and 1066 lb down at 9-6-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 1-3=-20 Concentrated Loads (lb) Vert: 4=-1048(F) 5=-1048(F) 6=-1048(F) 7=-1048(F) 8=-1066(F) October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss TG12 Truss Type Common Girder Qty 1 Ply 2 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117738 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:09 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-QEpSOg9tLNbhpwVdBDUzEOo6HEWBD2mB5WFDxuyNwdu Scale = 1:34.4 1 2 3 4567 8 9 10 11 4x6 3x12 4x8 4x8 7-4-07-4-0 14-8-07-4-0 7-4-0 7-4-0 14-8-0 7-4-0 0-9-05-7-110-9-08.00 12 Plate Offsets (X,Y)-- [1:0-0-6,0-0-8], [1:0-0-11,0-4-9], [1:Edge,0-1-1], [3:0-0-6,0-0-8], [3:0-0-11,0-4-9], [3:Edge,0-1-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.78 0.85 0.46 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.27 0.02 (loc) 3-4 3-4 3 l/defl >999 >641 n/a L/d 240 180 n/a PLATES MT20 Weight: 122 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=2978/0-3-8, 3=3489/0-3-8 Max Horz 1=-83(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3666/0, 2-3=-3662/0 BOT CHORD 1-4=0/2892, 3-4=0/2892 WEBS 2-4=0/3730 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-8-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 760 lb down at 2-2-12, 760 lb down at 4-2-12, 760 lb down at 6-2-12, 760 lb down at 8-2-12, 760 lb down at 10-2-12, and 760 lb down at 12-2-12, and 760 lb down at 12-9-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 1-3=-20 Concentrated Loads (lb) Vert: 5=-760(B) 6=-760(B) 7=-760(B) 8=-760(B) 9=-760(B) 10=-760(B) 11=-760(B) October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V01 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117739 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:09 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-QEpSOg9tLNbhpwVdBDUzEOoCBEi1D8lB5WFDxuyNwdu Scale = 1:25.8 1 2 3 4 5 8 7 6 9 10 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 15-5-115-5-1 7-8-8 7-8-8 15-5-1 7-8-8 0-0-43-10-40-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.40 0.09 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-5-1. (lb) - Max Horz 1=-47(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=275(LC 1), 8=335(LC 13), 6=335(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-253/97, 4-6=-253/97 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-8-8, Interior(1) 3-8-8 to 7-8-8, Exterior(2) 7-8-8 to 10-8-8, Interior(1) 10-8-8 to 14-9-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V02 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117740 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-uQNrb0AW6hjYR44plw?CnbLNKe?AybrLKA_mUKyNwdt Scale = 1:20.7 1 2 3 4 5 6 7 8 3x6 4x8 3x6 2x4 0-0-80-0-8 11-5-111-4-9 5-8-8 5-8-8 11-5-1 5-8-8 0-0-42-10-40-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.29 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=185/11-4-1, 3=185/11-4-1, 4=442/11-4-1 Max Horz 1=34(LC 8) Max Uplift 1=-6(LC 9), 3=-6(LC 9) Max Grav 1=187(LC 13), 3=187(LC 14), 4=442(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-288/87 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 5-8-8, Exterior(2) 5-8-8 to 8-8-8, Interior(1) 8-8-8 to 10-9-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V03 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117741 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-McxDpMA8t_rP3Ef0JeWRJptZq2Cdh3PUZqkK0myNwds Scale = 1:14.0 1 2 3 2x4 3x4 2x4 0-0-80-0-8 7-5-17-4-9 3-8-8 3-8-8 7-5-1 3-8-8 0-0-41-10-40-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.32 0.85 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=246/7-4-1, 3=246/7-4-1 Max Horz 1=-20(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V04 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117742 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-McxDpMA8t_rP3Ef0JeWRJpteG2O8h3PUZqkK0myNwds Scale = 1:7.0 1 2 3 2x4 3x4 2x4 0-0-80-0-8 3-5-13-4-9 1-8-8 1-8-8 3-5-1 1-8-8 0-0-40-10-40-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.04 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=86/3-4-1, 3=86/3-4-1 Max Horz 1=-7(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V05 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117743 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-qpVb0iBmeIzGgOECsL2gs0QmWRkjQV8eoUTtYDyNwdr Scale: 3/8"=1' 1 2 3 4 5 8 7 6 9 10 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-60-0-6 15-1-915-1-3 7-6-12 7-6-12 15-1-9 7-6-12 0-0-45-0-80-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.20 0.09 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-0-13. (lb) - Max Horz 1=-75(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=335(LC 13), 6=335(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-254/107, 4-6=-254/108 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-6-12, Interior(1) 3-6-12 to 7-6-12, Exterior(2) 7-6-12 to 10-6-12, Interior(1) 10-6-12 to 14-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V06 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117744 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-qpVb0iBmeIzGgOECsL2gs0QhIRghQVueoUTtYDyNwdr Scale = 1:25.7 1 2 3 4 5 6 7 8 3x8 4x8 3x8 2x4 0-0-60-0-6 12-1-912-1-3 6-0-12 6-0-12 12-1-9 6-0-12 0-0-44-0-80-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.53 0.35 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=220/12-0-13, 3=220/12-0-13, 4=454/12-0-13 Max Horz 1=-59(LC 7) Max Uplift 1=-9(LC 9), 3=-9(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-283/61 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 6-0-12, Exterior(2) 6-0-12 to 9-0-12, Interior(1) 9-0-12 to 11-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V07 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117745 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:13 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-I?3zD2COPc66IXpOQ2ZvPEzw0r3Q9yxn08DR4fyNwdq Scale = 1:20.6 1 2 3 4 5 6 7 8 3x6 4x6 3x6 2x4 0-0-60-0-6 9-1-99-1-3 4-6-12 4-6-12 9-1-9 4-6-12 0-0-43-0-80-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.19 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=161/9-0-13, 3=161/9-0-13, 4=332/9-0-13 Max Horz 1=-43(LC 7) Max Uplift 1=-7(LC 9), 3=-7(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 4-6-12, Exterior(2) 4-6-12 to 7-6-12, Interior(1) 7-6-12 to 8-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V08 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117746 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-nBdLROD09vEzwhNb_m48xRV6bFIIuP8xFoy_d5yNwdp Scale = 1:14.9 1 2 3 2x4 3x4 2x4 0-0-60-0-6 6-1-96-1-3 3-0-12 3-0-12 6-1-9 3-0-12 0-0-42-0-80-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.23 0.59 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=207/6-0-13, 3=207/6-0-13 Max Horz 1=27(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V09 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117747 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-nBdLROD09vEzwhNb_m48xRV9WFQtuP8xFoy_d5yNwdp Scale: 1.5"=1' 1 2 3 2x4 3x4 2x4 3-1-33-1-3 3-1-90-0-6 1-6-12 1-6-12 3-1-9 1-6-12 0-0-41-0-80-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.04 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=87/3-0-13, 3=87/3-0-13 Max Horz 1=-12(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V10 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117748 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-FOBkekDewDMqYrynYTbNUf2KSflddsO4USiX9YyNwdo Scale = 1:7.3 1 2 3 2x4 3x4 2x4 0-0-60-0-6 2-9-12-8-11 1-4-8 1-4-8 2-9-1 1-4-8 0-0-40-11-00-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.03 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=72/2-8-5, 3=72/2-8-5 Max Horz 1=-10(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V11 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117749 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-FOBkekDewDMqYrynYTbNUf2HrffpdsO4USiX9YyNwdo Scale = 1:14.2 1 2 3 2x4 3x4 2x4 0-0-60-0-6 5-9-15-8-11 2-10-8 2-10-8 5-9-1 2-10-8 0-0-41-11-00-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.19 0.51 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=192/5-8-5, 3=192/5-8-5 Max Horz 1=-25(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V12 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117750 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-jak6s4EGhXUh9?Xz5B6c0saOe34QMJnDi6R5h_yNwdn Scale = 1:19.8 1 2 3 4 5 6 7 8 2x4 4x6 2x4 2x4 0-0-60-0-6 8-9-18-8-11 4-4-8 4-4-8 8-9-1 4-4-8 0-0-42-11-00-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.51 0.17 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=169/8-8-5, 3=169/8-8-5, 4=286/8-8-5 Max Horz 1=-41(LC 7) Max Uplift 1=-13(LC 9), 3=-13(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 4-4-8, Exterior(2) 4-4-8 to 7-4-8, Interior(1) 7-4-8 to 8-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V13 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117751 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-jak6s4EGhXUh9?Xz5B6c0saOy31_MI?Di6R5h_yNwdn Scale = 1:25.1 1 2 3 4 5 6 7 8 3x8 4x8 3x8 2x4 0-0-60-0-6 11-9-111-8-11 5-10-8 5-10-8 11-9-1 5-10-8 0-0-43-11-00-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.49 0.32 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=212/11-8-5, 3=212/11-8-5, 4=438/11-8-5 Max Horz 1=57(LC 8) Max Uplift 1=-9(LC 9), 3=-9(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-273/60 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 5-10-8, Exterior(2) 5-10-8 to 8-10-8, Interior(1) 8-10-8 to 11-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V14 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117752 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BmIU3QFvSqcYn969fudrZ47ecSQI5lANxmBeDQyNwdm Scale = 1:35.6 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 0-0-60-0-6 16-5-116-4-11 8-2-8 8-2-8 16-5-1 8-2-8 0-0-45-5-110-0-48.00 12 Plate Offsets (X,Y)-- [8:0-2-3,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.18 0.19 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-4-5. (lb) - Max Horz 1=-82(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=367(LC 13), 6=367(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-276/113, 4-6=-275/112 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 8-2-8, Exterior(2) 8-2-8 to 11-2-8, Interior(1) 11-2-8 to 15-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V15 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117753 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BmIU3QFvSqcYn969fudrZ47WqSMX5kaNxmBeDQyNwdm Scale = 1:28.4 1 2 3 4 5 6 3x8 4x8 3x8 2x4 0-0-60-0-6 13-5-113-4-11 6-8-8 6-8-8 13-5-1 6-8-8 0-0-44-5-110-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.67 0.43 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=245/13-4-5, 3=245/13-4-5, 4=506/13-4-5 Max Horz 1=-66(LC 7) Max Uplift 1=-11(LC 9), 3=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-316/65 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 6-8-8, Exterior(2) 6-8-8 to 9-8-8, Interior(1) 9-8-8 to 12-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V16 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117754 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-fzssHlGXD8kPPJhMDc846HgmGslcqCuWAQwBmsyNwdl Scale = 1:22.4 1 2 3 4 5 6 7 8 3x6 4x6 3x6 2x4 0-0-60-0-6 10-5-110-4-11 5-2-8 5-2-8 10-5-1 5-2-8 0-0-43-5-110-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.25 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=186/10-4-5, 3=186/10-4-5, 4=384/10-4-5 Max Horz 1=-50(LC 7) Max Uplift 1=-8(LC 9), 3=-8(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 5-2-8, Exterior(2) 5-2-8 to 8-2-8, Interior(1) 8-2-8 to 9-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V17 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117755 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-fzssHlGXD8kPPJhMDc846HgmdslxqDTWAQwBmsyNwdl Scale = 1:17.5 1 2 3 4 2x4 4x6 2x4 2x4 0-0-60-0-6 7-5-17-4-11 3-8-8 3-8-8 7-5-1 3-8-8 0-0-42-5-110-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.35 0.23 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=138/7-4-5, 3=138/7-4-5, 4=240/7-4-5 Max Horz 1=34(LC 8) Max Uplift 1=-11(LC 9), 3=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V18 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117756 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-79QEU5H9_SsG0SGYnJgJeVC?fG6KZgOgP4glIJyNwdk Scale = 1:8.4 1 2 3 4 3x4 3x4 3x4 3x4 0-0-60-0-6 4-5-14-4-11 1-4-14 1-4-14 3-0-2 1-7-4 4-5-1 1-4-14 0-0-40-11-40-0-40-11-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-2-3], [3:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.08 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-1 oc purlins, except 2-0-0 oc purlins: 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=138/4-4-5, 4=138/4-4-5 Max Horz 1=10(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V19 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117757 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-bL_dhRHnll_7ecrkK1BYBil2kgOpI3ppdkPIqlyNwdj Scale = 1:52.6 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 18 19 20 3x6 4x6 3x6 3x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 0-0-80-0-8 31-5-931-5-1 15-8-12 15-8-12 31-5-9 15-8-12 0-0-47-10-60-0-46.00 12 Plate Offsets (X,Y)-- [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.57 0.39 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 96 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-3,7-9: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 31-4-9. (lb) - Max Horz 1=-108(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 13, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 1, 9 except 12=468(LC 1), 13=410(LC 13), 14=627(LC 1), 11=410(LC 14), 10=627(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-14=-411/134, 8-10=-411/134 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=31ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-9-3, Interior(1) 3-9-3 to 15-8-12, Exterior(2) 15-8-12 to 18-10-7, Interior(1) 18-10-7 to 30-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 14, 11, 10. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V20 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117758 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-bL_dhRHnll_7ecrkK1BYBil6lgRgI4JpdkPIqlyNwdj Scale = 1:46.3 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 3x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-80-0-8 27-5-927-5-1 13-8-12 13-8-12 27-5-9 13-8-12 0-0-46-10-60-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.31 0.21 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 27-4-9. (lb) - Max Horz 1=-90(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=466(LC 1), 12=380(LC 13), 13=420(LC 1), 9=380(LC 14), 8=420(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-13=-311/107, 6-8=-311/107 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=27ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 13-8-12, Exterior(2) 13-8-12 to 16-8-12, Interior(1) 16-8-12 to 26-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V21 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117759 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3XY?vnIPW36_GmQxukinjwICn4gW1YIysO9sMByNwdi Scale = 1:39.5 1 2 3 4 5 8 7 6 9 10 11 12 13 143x6 4x6 3x6 2x4 5x8 2x4 2x4 2x4 0-0-80-0-8 23-5-923-5-1 11-8-12 11-8-12 23-5-9 11-8-12 0-0-45-10-60-0-46.00 12 Plate Offsets (X,Y)-- [8:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.61 0.62 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 65 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 23-4-9. (lb) - Max Horz 1=73(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=288(LC 1), 8=651(LC 1), 6=650(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-435/141, 4-6=-431/141 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 11-8-12, Exterior(2) 11-8-12 to 14-8-12, Interior(1) 14-8-12 to 22-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V22 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117760 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3XY?vnIPW36_GmQxukinjwIG_4jg1ZMysO9sMByNwdi Scale = 1:32.8 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 0-0-80-0-8 19-5-919-5-1 9-8-12 9-8-12 19-5-9 9-8-12 0-0-44-10-60-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.34 0.42 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-4-9. (lb) - Max Horz 1=-60(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=450(LC 13), 6=450(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-333/113, 4-6=-330/113 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 9-8-12, Exterior(2) 9-8-12 to 12-8-12, Interior(1) 12-8-12 to 18-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V23 Truss Type GABLE Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117761 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Yk6N67J1HNErtw?7SRD0G7qNRT7Tm0j652uPveyNwdh Scale = 1:25.9 1 2 3 4 5 7 6 8 9 10 11 3x6 3x6 3x6 2x4 2x4 2x4 2x4 15-5-915-5-9 7-8-12 7-8-12 15-5-9 7-8-12 0-0-43-10-60-0-46.00 12 Plate Offsets (X,Y)-- [3:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.62 0.19 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 15-5-9. (lb) - Max Horz 1=47(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 7, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=417(LC 13), 6=417(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-7=-309/116, 4-6=-309/116 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 7-8-12, Exterior(2) 7-8-12 to 10-8-12, Interior(1) 10-8-12 to 14-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 6. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V24 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117762 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Yk6N67J1HNErtw?7SRD0G7qQGT5xm0p652uPveyNwdh Scale = 1:20.8 1 2 3 4 5 6 7 8 3x6 4x8 3x6 2x4 0-0-80-0-8 11-5-911-5-1 5-8-12 5-8-12 11-5-9 5-8-12 0-0-42-10-60-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.29 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=186/11-4-9, 3=186/11-4-9, 4=444/11-4-9 Max Horz 1=34(LC 8) Max Uplift 1=-6(LC 9), 3=-6(LC 9) Max Grav 1=188(LC 13), 3=188(LC 14), 4=444(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-289/87 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 5-8-12, Exterior(2) 5-8-12 to 8-8-12, Interior(1) 8-8-12 to 10-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V25 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117763 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-0wflKTKf2gMiV4ZJ09kFpLNcktIFVUNFJieyR4yNwdg Scale = 1:14.0 1 2 3 2x4 3x4 2x4 0-0-80-0-8 7-5-97-5-1 3-8-12 3-8-12 7-5-9 3-8-12 0-0-41-10-60-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.33 0.86 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=248/7-4-9, 3=248/7-4-9 Max Horz 1=21(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V26 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117764 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-0wflKTKf2gMiV4ZJ09kFpLNeUtNlVUNFJieyR4yNwdg Scale = 1:12.4 1 2 3 2x4 3x4 2x4 0-0-80-0-8 6-3-96-3-1 3-1-12 3-1-12 6-3-9 3-1-12 0-0-41-6-140-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.22 0.57 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=201/6-2-9, 3=201/6-2-9 Max Horz 1=-17(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V27 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117765 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-U6D7XpKIp_UZ7E8WZsFULYwkIHmVEwsPYMNWzWyNwdf Scale = 1:25.7 1 2 3 4 5 6 7 8 3x8 4x8 3x8 2x4 12-0-1512-0-15 12-1-50-0-6 6-0-10 6-0-10 12-1-5 6-0-10 0-0-44-0-70-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.53 0.35 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=219/12-0-9, 3=219/12-0-9, 4=453/12-0-9 Max Horz 1=-59(LC 7) Max Uplift 1=-9(LC 9), 3=-9(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-282/61 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 6-0-10, Exterior(2) 6-0-10 to 9-0-10, Interior(1) 9-0-10 to 11-7-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V28 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117766 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-U6D7XpKIp_UZ7E8WZsFULYwoGHp?ExfPYMNWzWyNwdf Scale = 1:20.6 1 2 3 4 5 6 7 8 3x6 4x6 3x6 2x4 0-0-60-0-6 9-1-59-0-15 4-6-10 4-6-10 9-1-5 4-6-10 0-0-43-0-70-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.19 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=160/9-0-9, 3=160/9-0-9, 4=331/9-0-9 Max Horz 1=-43(LC 7) Max Uplift 1=-7(LC 9), 3=-7(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 4-6-10, Exterior(2) 4-6-10 to 7-6-10, Interior(1) 7-6-10 to 8-7-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V29 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117767 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-yJnVl9LwaIcPkNji7amjumS_rh2xzOtYn073VyyNwde Scale = 1:14.8 1 2 3 2x4 3x4 2x4 6-0-156-0-15 6-1-50-0-6 3-0-10 3-0-10 6-1-5 3-0-10 0-0-42-0-70-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.22 0.59 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=206/6-0-9, 3=206/6-0-9 Max Horz 1=-27(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V30 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117768 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-yJnVl9LwaIcPkNji7amjumS1lhATzOtYn073VyyNwde Scale = 1:7.9 1 2 3 2x4 3x4 2x4 0-0-60-0-6 3-1-53-0-15 1-6-10 1-6-10 3-1-5 1-6-10 0-0-41-0-70-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.04 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=86/3-0-9, 3=86/3-0-9 Max Horz 1=11(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-190 Truss V31 Truss Type Valley Qty 1 Ply 1 Pyatt Bldrs - 190 The Grove Job Reference (optional) I39117769 8.240 s Jul 14 2019 MiTek Industries, Inc. Thu Oct 31 10:13:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-QVLuyVMYLbkGMXIuhHIyQz?Ak5R6ir7i0gsd2PyNwdd Scale = 1:13.3 1 2 3 2x4 3x4 2x4 0-0-60-0-6 5-2-55-1-15 2-7-2 2-7-2 5-2-5 2-7-2 0-0-41-8-120-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.15 0.40 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=169/5-1-9, 3=169/5-1-9 Max Horz 1=-22(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. October 31,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths