HomeMy WebLinkAboutA000.7MIN. 22 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C"
MIN. 100 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E"
MIN. 85 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION POT VENTS
GUTTER AND DOWNSPOUTS
\A1;1'-0"\PTYP.
\A1;14'-6"
\A1;4'-0{\H0.75x;\S1#4;}"
\A1;2'-11"\A1;1'-0"
\A1;24'-0"
\A1;9'-0"
\A1;7'-0"
\A1;2'-11"
\A1;9{\H0.75x;\S1#2;}"
9:12
9:12
8:12
8:12
9:12
9:129:12
3.5:12
8:128:12
3.5:12
9:12
9:12
9:12
9:12
9:12
9:129:12
8:12
8:12
"A"
2421ROOF AREA:
SQ. FT.
"B"
476ROOF AREA:
SQ. FT.
9:129:12
9:12
9:12ELEVATION HR3SATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "A"SQ FTG2421AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.234.044.2450.00100AT EAVE4.844.044.2450.00061.00TOTAL (MIN)8.078.078.47100.003 HIGH -RIDGE VENT3.234.044.1349.340033.00AT EAVE4.844.044.2450.66061.00TOTAL (MIN)8.078.078.36100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEELEVATION HR3SROOF AREA "B"SQ FTG476AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.630.790.8548.4120AT EAVE0.950.790.9051.59013.00TOTAL (MIN)1.591.591.75100.003 HIGH -RIDGE VENT0.630.790.8849.22007.00AT EAVE0.950.790.9050.78013.00TOTAL (MIN)1.591.591.78100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE8:12
A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc.
PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Skyview
2056.300Home for * Market Home *, 5782-124003326 Spruce Wood Court, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
12/02/19
William Hohlt