HomeMy WebLinkAboutA2.0-1 Construction Plan- 1st FloorPPOJELT COOPDINATOP�DESIGN CONSULTANI 1 ST FLOOR KEY PLAN �� � I, / � / � � / / / / V � 1 ST FLOOR ROOM SCHEDULE NUMBER ROOM NAME NUMBER 101 qECEPTION 113 102 TRAINING ROOM 114 103 BREAKROOM 115 104 STORAGE 116 1 W CABLE CLOSET 1 n 106 OPENAREA 118 119 RELEASED FOR CONSTRl1CTI0N ,Zo Su6jec��ocompliancewithallregula�ions 12� of Sla�e antl Local Codes � pp CityofCarmel EA 123 �I `��¢m�' lamn�Mn?>� � onrE: 12/09/19 ROOM NAME OPEN AFEA OFFICE OFFICE OFFICE OFFICE COAT CLOSET STORAGE HUDDLE CONFEFENCE OPEN AREA CORRIDOR ,o� , o, ,,, � 01/A6.0 ��..�v � � ,��� m �_���..., / `� \ ' ;� �_p I �/ E�. I 5 / E�. /� �� 1 m O CJ ' 32'-9' r =� _ _ c� ¢ 1 CONSTRUCTION PLAN - 1 ST FLOOR SCALE: 1/e" = 1'-0" � � � � � 0 5 ,0 20 � NORTH / / /� x0 CONSTRUCTION KEYNOTES USED # NOTE � 1 EXISTINGCONTROLJOINTTOREMAIN. 2 GC TO ENSUFE EXITING PAFTITION CONSTFUCTION MATCHES PAFTITION TVPE "2X".IFNOT,l1PGRADEASNEEDED. � 3 INSTALLCLERESTORV WINDOW SALVAGED FROM DEMOLITION STORAGE. GC TO PROVIDE FRAMING AND BLOCK AS RE�UIRED. REFERENCE ELEVATION 01/A6.0. � 4 GCTOPROVIDEBLOCKINGWITHINNEWWALLONCENTERAFFATTHE FOLLOWING HEIGHTS: ' 633/4"14A) ' 64"14C) '56"14B) '�2"14D) BLOCKING TO SUPPORT SX THE WEIGHT OF MONITOR. GC TO COORDINATE WITH CBRE PROJECT MANAGER AND TRAVELERS AV AND CABLING VENDOFS FOFADDITIONAL MFOFMATION. 5 GCTOMSTALL36'WX24"HX3/4FRTSURFACEMOUNTEDPLYWOOD BLOCKING ON CENTER AFF AT THE FOLLO WING HEIGHTS: " 633/4" (SA) " 84" (SC) ' S6" (5B) ' ]2" (SD) PLYWOOD TO BE SECl1RELV ATTACHED TO WALL STRl1CTl1RE AND STUDS SUFFICIENT TO SUPPORT SX TH E WEIGHT OF MONITOR. GC TO COOPDINATE WITH CBPE PPOJECT MANAGEP AND TPAVELEPS AV AND CABLING VENDORS. PLYWOODTO BE PAMTED TO MATCH WALL. REFERENCE SHEET SERIES A25 FOR ADDITIONAL INFORMATION. 6 PROVIDEI;4"COPPERHOTANDCOLDWATERLMEWITHEMERGENCV SHUT-0FF VALVES AND DFAIN WASTE LME AT SINK AS SGHEDULED. � GCTOINSTALLSEMI-aECE55EOFIaEEXTINGUISHEPCABMETANDFlPE EXTINGWSHER SALVAGED FROM DEMOLITION STORAGE. GC TO ENSl1RE THAT FlRE EXTINGUISHER IS IN PROPER WORKING ORDER. CABINETTO 6E INSTALLED AT 48" AFF TO TOP OF PULL. FEFEPENCE 13/A8.0. � 8 GCTOPFOVIDECONTFOLJOINTATWALLASSHOWN.CONTFOLJOINT TO MATCH OTHER CONTROL JOINTS ON SITE. 9 GCREMSTALLADJl1STABLESHELVINGSl1PPORTSAND(5)ADJl1STABLE SHELVES SALVAGED FROM DEMOLITION STORAGE. MODIFY SHELVING AS NEEDED TO FlT WITHIN NEW CLOSET. 10 GCTOINVESTIGATECAUSEOFWATERDAMAGEANDCOORDINATEWITH BWLDINGMANAGERTOMAKENECESSARVREPAIRS. ENSl1REWALLS ARE AND PATCHED AS NEEDED IN PREPARATION FOR REPAINTING ROOM AS SCHEDULED. COOFDINATE WITH CBFE PFOJECT MANAGEF FOF ALLOWANCE TO BE INCUIDED IN BID 11 GCTOPROVIDENEWSEMIRECESSEDFIREIXTINGWSHERCABMETAND FIRE EXTINGUISHER. NEW EQUIPMENTTO MATCH EXISTING ON SITE. � 12 GC TO MSTALL SIDE LITE WITH FROST FlLM BLOCK DESIGN SALVAGED FROM DEMOLITION STORAGE LEAVEB"OF DRYWALL BETNEEN FRAMES ASSHOWN. WALL LEGEND IXISTING MTERIOW EXTERIOR WALLTO REMAIN NEW INTERIOR WALLAS SCHEDULED r. : MTERIOR/IXTERIORGLAZINGSVSTEM ------- NEW 1-HOUR FIRE RATED INTERIOR WALL CONSTRUCTION LEGEND � SEMIRECESSEDFIREEXTINGUISHERCABINETANDFIRE U EXTINGUISHEFTO COMPLV WITH UL#?A-10B:C --�X WALLT'PE-PEFEPENCESHEEfA80 �FP FIREALARMPULL �I� CONTPOLJOINT III�.,c DOORID-PEFEPENCEDOORSCHEDULEA].0 LU XX E�UIPMENTTAG.PEFEPENCEG0.IFOPE�UIPMENT SCHEDULE R 'F' DENOTES EXISTING ITEM TO BE FELOCATED N 'N' DENOTES NEW ITEM ACCESSIBILITY NOTES: 1. NO ABRUPT CHANGES IN ELEVATION ALONG PATH OF TRAVEL SHALL BE 2 SLOPES SHALL NOT TO EXCEED L20 UNLESS A RAMP IS PROVIDED. 3. RAMPSSHALLNOTEXCEED1:12SLOPE. 4. CROSS SLOPES SHALL NOT IXCEED 2%. 5. MAXIMUMI/2"THRESHOLDHEIGHT. CONSTRUCTION PLAN NOTES: • FEFEFENCE SHEEf G0 0, G0.1, G0.3, AN D GOA FOF APPLICABLE GENEFAL NOTES, SPECIFICATIONS AND ALTERNATES. • BULLETED NOTES ARE GENERAL CONDITIONS REpUIRED FOR THE PLAN. NUMBEFED NOTATIONS FEFEFENCESPEQFlC LOCATIONS ON THE DFAWINGS. • GC TO FOLLOW LANDLORD Rl1LES AND REGl1LATIONS AS IT APPLIES TO ALL CONSTRUCTION GUIDELINES/REpUIREMENTS. • EXISTING CONDITION MFORMATION HAS BEEN BASED ON AS-BUILT DFAWINGS. CONTRACTOR TO FIELD VERIFV ALL EXISTING CONDITIONS PRIOR TO PRICING AND CONSTRUCTION. COORDINATEANV DISCREPANCIES WITH itlGROUP. • SPACE WILL BE OCCUPIED DUPING ALTERATIONS. CONTPACTOP TO PPOVIDE A BARRIERATAREAOFWORKTOCONTROLNOISEANDDUSL GCTOCOORDINATE W ITH CBRE PROJECT MANAGER ON W HETHER THERE WILL NEED TO BE A TEMPOPAPV WALL PUT IN PLACE FOP THE BAPPIEP OP WHETHEP A POLV VINVL BAFFIEF WILL BESUFFlQENT. • GENERAL CONTRACTOR TO MAINTAIN EXITING FOR LIFE SAFETV DURING ALL PHASES OF CONSTRUCTION. • ALL WOFK TO BE DONE AREF HOUFS. COOFDINATE ANV CONCEFNS OR POTENTIAL DEVIATION WITH CBRE PROJECT MANAGER. • WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS ON THE CONSTFUCTION DOCUMENTS. •THEGENERALCONTRACTORSHALLFlELDVERIFYALL MEASUREMENTS, LOCATIONS AND CHARACTERISTICS OF ALL WORK AN D EpUIPMENT AND COOPDINATEWITHTHE MANUFACTUPEPOPSUPPLIEPPPIOPTOTHESTAPTOF RELATED WORK. • ALL DIMENSIONS SHOWN ARE FROM FINISHED FACE TO FINISHED FACE, UAN. • PATCH AND PEPAIP WALLS WHERE DEMOLITION, DAMAGE OR INCOMPLETE WOPK HAS OCCURRED. PREPARE WALLS FOR NEW SCHEDULED FlNISHES. WALL TEXTURE TO MATCH EXCITING WITHIN SUITE. • WALLANGLES ARE PARALLEL, PERPENDICULAR OR IN 45 DEGREE INCREMENTS TO BUILDING PERIMETER WALL, U.O.N. • ALL NEW PARTITIONS TO BE WALLTVPE "1X", UNLESS OTHERWISE NOTED. • IF HEIGHT OF STUDS SPANS MORE THAN 15'-0" CONTRACTOR TO COORDINATE EXACT SRE, GAUGE, AND SPAQNG WITH AFCHITECT PFIOF TO OFDEFING AND MSTALLATION. MANl1FACTl1RER TO BE DIETRICH OR APPROVED Epl1AL. •VERIFY AVAILABILI71' OF MATERIALS TO BE USED FROM BWLDING STOCK WITH BUILDING MANAGEF PFIOFTO PUFCHASING MATEFIALS. • CONSTRUCTION MATERIAL SPECIFlCATIONS TO BE ASBESTOS FREE. • PROVIDE DOUBLE METAL STUDS AND BRACING TO UNDERSIDE OF STRUCTURE AT ALL DOOP FMMES. • LOCATE DOOR OPENING 4" AWAV FROM ADJACENT CORNER, U.O.N. ALL DOORS TO OPEN TO A MINIMUM OF 90 DEGREES. MAINTAIN 1'-6" CLEAR ON PULL SIDE OF DOOR AND 1'-0" ON PUSH SIDE OF DOOR. • DOORS NOT NOTED ARE IXISTING TO REMAIN. TOUCH UP ALL DOORS AND DOOR FRAMES WITHIN SCOPETO INDUSTRV STANDARD LEVELOF REFURBISHMENT. • PROVIDE FlPE PEfAPDANT TPEATED BLOCKING AS PEQUIRED BV CODE WITHIN WALL, TO SUPPOFT MILLWOFK, MAFKEF BOAFDS, TACKABLE SURFACES, AND WALL Hl1NG Ep W PMENT. • PARTITIONS AND GVPSUM BOARD CEW NGS SHALL BE TAPED, FlLLED, SANDED SMOOTH AND PFEPAFED FOF SCHEDULED FlNISHES. • ALL MILLWORK DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO THE COMMENCEMENTOFWORK. • NEW MILLWOPK CABMEfS TO BE FLUSH OVEPLAV STVLE, U.O.N. • PROVIDE WATER RESISTANT GVPSUM BOARD AT PLUMBING LOCATIONS. • REFERENCE EQUIPMENT SCHEDULE ON SHEET G0.1 FOR EpUIPMENT TO BE PROVIDED BV CONTPACTOP. PPOVIDE AND INSTALL WATERLME AND DPAIN LME FOR ALL APPLIANCES AS REp W RED. • PROVIDE FIRESAFING ON STEEL BW LDING COLUMNS THAT ARE DAMAGED OR MISSING AS PE�UIPED BV LOCAL BUILDING AND FlPE CODES. • FIFE ALAFM PULLS AND LIFE SAFEiV SVSTEMS SHALL CONFOFM TO TO LOCAL, MUNICIPALAND FIRE PREVENTION CODES. EXISTING PULLS TO REMAIN, UAN. NOTIFV idGROUP OF ANV DISCREPANCIES. • CONTFACTOF TO COOFDINATE TENANT PFOVIDED TRAVELEFS STANDARD OFFlCE ANDCOMMONAREASIGNAGEINAREAOFWORK. SIGNAGETOBEPROVIDEDAND INSTALLED BV TENANT VENDORS. • EXISTING WINDOW COVERINGS TO FEMAIN. MODIF/AS NECESSAFV WHEFE AFFECTED BV NEW WALL CONSTRl1CTION. NOTIFV IDGROl1P OF ANV DISCREPANCIES. • ENSUPE BLIND CONTPOLS ARE AT OPERABLE LOCATION W ITHIN ROOM. IF NOT DUE TO NEW WALL CONFlGURATION, REVISE OPERATING LOCATION OR REPLACEAS REQUIREDTO MATCH EXISTING. • FIRE EXTINGUISHER CABINETS AND FIRE EXTINGUISHERS TO CONFIRM TO LOCAL, MUNICIPAL AND FlRE PREVENTION CODES. GC TO CONFlRM THAT ANV REUSED/RELOCATED FIRE EXTINGUISHERS ARE IN PROPER WORKING ORDER. • GC TO MAINTAM EXISTING CONTPOL JOINT AND PPOVIDE NEW CONTROL JOINTS AS NEEDED DUE TO NEW CONSTFUCTION. � �� y6• •I� 13 12 ` 'CJ / 1 % id 2fi41 IRVING BLVD. DALLA$ TEXAS �520� TEL: 214-638-6800 AR���rE�r,E����EER ' QP� . D: .M�! ��"'••. : �Q, , P�G\ST EFFQ -9�: • (No.naneaaaaal. • aao�ECT No.: DRAWN BY'. CHECKEDBY: TRAVELERB PROJECTY: __f LI �n �� � � � � � � INDIANAPOLIS 10.14.19 aas oao MPNP HN/NC/CM P10 0312 SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1ST, 2ND, & 3RD FLOOR INDIANAPOLIS, IN 46240 NO. REVISIONS'. DATP. LAN�LOR� REVIEW ISSUE �ATE TENANT REVIEW ISSUE DATE: eio issue onie. PERMIT ISSUE �ATE CONSTRUCTION ISSUE DATH 10]4]9 100019 m�ais 10]4]9 %%/%%2019 �RAWING TITLE: CONSTRUCTION PLAN - 1 ST FLOOR DRAWING NUMBER. A2.0-1 �O 2019 idGROUP, LLC � RENOVATION AREA OF WORK