HomeMy WebLinkAboutA2.0-1 Construction Plan- 1st FloorPPOJELT COOPDINATOP�DESIGN CONSULTANI
1 ST FLOOR KEY PLAN
�� �
I,
/ �
/
�
�
/
/
/
/
V �
1 ST FLOOR ROOM SCHEDULE
NUMBER ROOM NAME NUMBER
101 qECEPTION 113
102 TRAINING ROOM 114
103 BREAKROOM 115
104 STORAGE 116
1 W CABLE CLOSET 1 n
106 OPENAREA 118
119
RELEASED FOR CONSTRl1CTI0N ,Zo
Su6jec��ocompliancewithallregula�ions 12�
of Sla�e antl Local Codes � pp
CityofCarmel EA 123
�I
`��¢m�' lamn�Mn?>�
�
onrE: 12/09/19
ROOM NAME
OPEN AFEA
OFFICE
OFFICE
OFFICE
OFFICE
COAT CLOSET
STORAGE
HUDDLE
CONFEFENCE
OPEN AREA
CORRIDOR
,o�
, o, ,,,
� 01/A6.0 ��..�v �
�
,��� m
�_���..., / `� \ ' ;� �_p
I
�/ E�. I 5 / E�. /�
��
1
m O
CJ '
32'-9'
r =� _ _
c�
¢
1
CONSTRUCTION PLAN - 1 ST FLOOR
SCALE: 1/e" = 1'-0"
�
� �
� �
0 5 ,0 20
�
NORTH
/
/
/�
x0 CONSTRUCTION KEYNOTES
USED # NOTE
� 1 EXISTINGCONTROLJOINTTOREMAIN.
2 GC TO ENSUFE EXITING PAFTITION CONSTFUCTION MATCHES PAFTITION
TVPE "2X".IFNOT,l1PGRADEASNEEDED.
� 3 INSTALLCLERESTORV WINDOW SALVAGED FROM DEMOLITION STORAGE.
GC TO PROVIDE FRAMING AND BLOCK AS RE�UIRED. REFERENCE
ELEVATION 01/A6.0.
� 4 GCTOPROVIDEBLOCKINGWITHINNEWWALLONCENTERAFFATTHE
FOLLOWING HEIGHTS:
' 633/4"14A) ' 64"14C)
'56"14B) '�2"14D)
BLOCKING TO SUPPORT SX THE WEIGHT OF MONITOR. GC TO
COORDINATE WITH CBRE PROJECT MANAGER AND TRAVELERS AV AND
CABLING VENDOFS FOFADDITIONAL MFOFMATION.
5 GCTOMSTALL36'WX24"HX3/4FRTSURFACEMOUNTEDPLYWOOD
BLOCKING ON CENTER AFF AT THE FOLLO WING HEIGHTS:
" 633/4" (SA) " 84" (SC)
' S6" (5B) ' ]2" (SD)
PLYWOOD TO BE SECl1RELV ATTACHED TO WALL STRl1CTl1RE AND
STUDS SUFFICIENT TO SUPPORT SX TH E WEIGHT OF MONITOR. GC TO
COOPDINATE WITH CBPE PPOJECT MANAGEP AND TPAVELEPS AV AND
CABLING VENDORS. PLYWOODTO BE PAMTED TO MATCH WALL.
REFERENCE SHEET SERIES A25 FOR ADDITIONAL INFORMATION.
6 PROVIDEI;4"COPPERHOTANDCOLDWATERLMEWITHEMERGENCV
SHUT-0FF VALVES AND DFAIN WASTE LME AT SINK AS SGHEDULED.
� GCTOINSTALLSEMI-aECE55EOFIaEEXTINGUISHEPCABMETANDFlPE
EXTINGWSHER SALVAGED FROM DEMOLITION STORAGE. GC TO ENSl1RE
THAT FlRE EXTINGUISHER IS IN PROPER WORKING ORDER. CABINETTO
6E INSTALLED AT 48" AFF TO TOP OF PULL. FEFEPENCE 13/A8.0.
� 8 GCTOPFOVIDECONTFOLJOINTATWALLASSHOWN.CONTFOLJOINT
TO MATCH OTHER CONTROL JOINTS ON SITE.
9 GCREMSTALLADJl1STABLESHELVINGSl1PPORTSAND(5)ADJl1STABLE
SHELVES SALVAGED FROM DEMOLITION STORAGE. MODIFY SHELVING AS
NEEDED TO FlT WITHIN NEW CLOSET.
10 GCTOINVESTIGATECAUSEOFWATERDAMAGEANDCOORDINATEWITH
BWLDINGMANAGERTOMAKENECESSARVREPAIRS. ENSl1REWALLS
ARE AND PATCHED AS NEEDED IN PREPARATION FOR REPAINTING ROOM
AS SCHEDULED. COOFDINATE WITH CBFE PFOJECT MANAGEF FOF
ALLOWANCE TO BE INCUIDED IN BID
11 GCTOPROVIDENEWSEMIRECESSEDFIREIXTINGWSHERCABMETAND
FIRE EXTINGUISHER. NEW EQUIPMENTTO MATCH EXISTING ON SITE.
� 12 GC TO MSTALL SIDE LITE WITH FROST FlLM BLOCK DESIGN SALVAGED
FROM DEMOLITION STORAGE LEAVEB"OF DRYWALL BETNEEN FRAMES
ASSHOWN.
WALL LEGEND
IXISTING MTERIOW EXTERIOR WALLTO REMAIN
NEW INTERIOR WALLAS SCHEDULED
r. : MTERIOR/IXTERIORGLAZINGSVSTEM
------- NEW 1-HOUR FIRE RATED INTERIOR WALL
CONSTRUCTION LEGEND
� SEMIRECESSEDFIREEXTINGUISHERCABINETANDFIRE
U EXTINGUISHEFTO COMPLV WITH UL#?A-10B:C
--�X WALLT'PE-PEFEPENCESHEEfA80
�FP FIREALARMPULL
�I� CONTPOLJOINT
III�.,c DOORID-PEFEPENCEDOORSCHEDULEA].0
LU
XX E�UIPMENTTAG.PEFEPENCEG0.IFOPE�UIPMENT
SCHEDULE
R 'F' DENOTES EXISTING ITEM TO BE FELOCATED
N 'N' DENOTES NEW ITEM
ACCESSIBILITY NOTES:
1. NO ABRUPT CHANGES IN ELEVATION ALONG PATH OF TRAVEL SHALL BE
2 SLOPES SHALL NOT TO EXCEED L20 UNLESS A RAMP IS PROVIDED.
3. RAMPSSHALLNOTEXCEED1:12SLOPE.
4. CROSS SLOPES SHALL NOT IXCEED 2%.
5. MAXIMUMI/2"THRESHOLDHEIGHT.
CONSTRUCTION PLAN NOTES:
• FEFEFENCE SHEEf G0 0, G0.1, G0.3, AN D GOA FOF APPLICABLE GENEFAL NOTES,
SPECIFICATIONS AND ALTERNATES.
• BULLETED NOTES ARE GENERAL CONDITIONS REpUIRED FOR THE PLAN.
NUMBEFED NOTATIONS FEFEFENCESPEQFlC LOCATIONS ON THE DFAWINGS.
• GC TO FOLLOW LANDLORD Rl1LES AND REGl1LATIONS AS IT APPLIES TO ALL
CONSTRUCTION GUIDELINES/REpUIREMENTS.
• EXISTING CONDITION MFORMATION HAS BEEN BASED ON AS-BUILT DFAWINGS.
CONTRACTOR TO FIELD VERIFV ALL EXISTING CONDITIONS PRIOR TO PRICING AND
CONSTRUCTION. COORDINATEANV DISCREPANCIES WITH itlGROUP.
• SPACE WILL BE OCCUPIED DUPING ALTERATIONS. CONTPACTOP TO PPOVIDE A
BARRIERATAREAOFWORKTOCONTROLNOISEANDDUSL GCTOCOORDINATE
W ITH CBRE PROJECT MANAGER ON W HETHER THERE WILL NEED TO BE A
TEMPOPAPV WALL PUT IN PLACE FOP THE BAPPIEP OP WHETHEP A POLV VINVL
BAFFIEF WILL BESUFFlQENT.
• GENERAL CONTRACTOR TO MAINTAIN EXITING FOR LIFE SAFETV DURING ALL
PHASES OF CONSTRUCTION.
• ALL WOFK TO BE DONE AREF HOUFS. COOFDINATE ANV CONCEFNS OR
POTENTIAL DEVIATION WITH CBRE PROJECT MANAGER.
• WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS ON THE
CONSTFUCTION DOCUMENTS.
•THEGENERALCONTRACTORSHALLFlELDVERIFYALL MEASUREMENTS,
LOCATIONS AND CHARACTERISTICS OF ALL WORK AN D EpUIPMENT AND
COOPDINATEWITHTHE MANUFACTUPEPOPSUPPLIEPPPIOPTOTHESTAPTOF
RELATED WORK.
• ALL DIMENSIONS SHOWN ARE FROM FINISHED FACE TO FINISHED FACE, UAN.
• PATCH AND PEPAIP WALLS WHERE DEMOLITION, DAMAGE OR INCOMPLETE WOPK
HAS OCCURRED. PREPARE WALLS FOR NEW SCHEDULED FlNISHES. WALL TEXTURE
TO MATCH EXCITING WITHIN SUITE.
• WALLANGLES ARE PARALLEL, PERPENDICULAR OR IN 45 DEGREE INCREMENTS TO
BUILDING PERIMETER WALL, U.O.N.
• ALL NEW PARTITIONS TO BE WALLTVPE "1X", UNLESS OTHERWISE NOTED.
• IF HEIGHT OF STUDS SPANS MORE THAN 15'-0" CONTRACTOR TO COORDINATE
EXACT SRE, GAUGE, AND SPAQNG WITH AFCHITECT PFIOF TO OFDEFING AND
MSTALLATION. MANl1FACTl1RER TO BE DIETRICH OR APPROVED Epl1AL.
•VERIFY AVAILABILI71' OF MATERIALS TO BE USED FROM BWLDING STOCK WITH
BUILDING MANAGEF PFIOFTO PUFCHASING MATEFIALS.
• CONSTRUCTION MATERIAL SPECIFlCATIONS TO BE ASBESTOS FREE.
• PROVIDE DOUBLE METAL STUDS AND BRACING TO UNDERSIDE OF STRUCTURE AT
ALL DOOP FMMES.
• LOCATE DOOR OPENING 4" AWAV FROM ADJACENT CORNER, U.O.N. ALL DOORS TO
OPEN TO A MINIMUM OF 90 DEGREES. MAINTAIN 1'-6" CLEAR ON PULL SIDE OF
DOOR AND 1'-0" ON PUSH SIDE OF DOOR.
• DOORS NOT NOTED ARE IXISTING TO REMAIN. TOUCH UP ALL DOORS AND DOOR
FRAMES WITHIN SCOPETO INDUSTRV STANDARD LEVELOF REFURBISHMENT.
• PROVIDE FlPE PEfAPDANT TPEATED BLOCKING AS PEQUIRED BV CODE WITHIN
WALL, TO SUPPOFT MILLWOFK, MAFKEF BOAFDS, TACKABLE SURFACES, AND
WALL Hl1NG Ep W PMENT.
• PARTITIONS AND GVPSUM BOARD CEW NGS SHALL BE TAPED, FlLLED, SANDED
SMOOTH AND PFEPAFED FOF SCHEDULED FlNISHES.
• ALL MILLWORK DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO THE
COMMENCEMENTOFWORK.
• NEW MILLWOPK CABMEfS TO BE FLUSH OVEPLAV STVLE, U.O.N.
• PROVIDE WATER RESISTANT GVPSUM BOARD AT PLUMBING LOCATIONS.
• REFERENCE EQUIPMENT SCHEDULE ON SHEET G0.1 FOR EpUIPMENT TO BE
PROVIDED BV CONTPACTOP. PPOVIDE AND INSTALL WATERLME AND DPAIN LME
FOR ALL APPLIANCES AS REp W RED.
• PROVIDE FIRESAFING ON STEEL BW LDING COLUMNS THAT ARE DAMAGED OR
MISSING AS PE�UIPED BV LOCAL BUILDING AND FlPE CODES.
• FIFE ALAFM PULLS AND LIFE SAFEiV SVSTEMS SHALL CONFOFM TO TO LOCAL,
MUNICIPALAND FIRE PREVENTION CODES. EXISTING PULLS TO REMAIN, UAN.
NOTIFV idGROUP OF ANV DISCREPANCIES.
• CONTFACTOF TO COOFDINATE TENANT PFOVIDED TRAVELEFS STANDARD OFFlCE
ANDCOMMONAREASIGNAGEINAREAOFWORK. SIGNAGETOBEPROVIDEDAND
INSTALLED BV TENANT VENDORS.
• EXISTING WINDOW COVERINGS TO FEMAIN. MODIF/AS NECESSAFV WHEFE
AFFECTED BV NEW WALL CONSTRl1CTION. NOTIFV IDGROl1P OF ANV
DISCREPANCIES.
• ENSUPE BLIND CONTPOLS ARE AT OPERABLE LOCATION W ITHIN ROOM. IF NOT DUE
TO NEW WALL CONFlGURATION, REVISE OPERATING LOCATION OR REPLACEAS
REQUIREDTO MATCH EXISTING.
• FIRE EXTINGUISHER CABINETS AND FIRE EXTINGUISHERS TO CONFIRM TO LOCAL,
MUNICIPAL AND FlRE PREVENTION CODES. GC TO CONFlRM THAT ANV
REUSED/RELOCATED FIRE EXTINGUISHERS ARE IN PROPER WORKING ORDER.
• GC TO MAINTAM EXISTING CONTPOL JOINT AND PPOVIDE NEW CONTROL JOINTS
AS NEEDED DUE TO NEW CONSTFUCTION.
�
��
y6•
•I� 13
12
` 'CJ
/
1 %
id
2fi41 IRVING BLVD.
DALLA$ TEXAS �520�
TEL: 214-638-6800
AR���rE�r,E����EER
' QP� . D: .M�! ��"'••.
: �Q, , P�G\ST EFFQ -9�:
• (No.naneaaaaal. •
aao�ECT No.:
DRAWN BY'.
CHECKEDBY:
TRAVELERB PROJECTY:
__f LI
�n
��
�
�
�
�
�
�
INDIANAPOLIS
10.14.19
aas oao
MPNP
HN/NC/CM
P10 0312
SEVEN PARKWOOD
CROSSING
280 E. 96TH STREET
1ST, 2ND, & 3RD FLOOR
INDIANAPOLIS, IN 46240
NO. REVISIONS'. DATP.
LAN�LOR� REVIEW ISSUE �ATE
TENANT REVIEW ISSUE DATE:
eio issue onie.
PERMIT ISSUE �ATE
CONSTRUCTION ISSUE DATH
10]4]9
100019
m�ais
10]4]9
%%/%%2019
�RAWING TITLE:
CONSTRUCTION PLAN -
1 ST FLOOR
DRAWING NUMBER.
A2.0-1
�O 2019 idGROUP, LLC
� RENOVATION AREA OF WORK