Loading...
HomeMy WebLinkAboutA2.2-3 Power & Communications Plan- 3rd Floor3RD FLOOR KEY PLAN ST.�IF H2 H � E .._' � I�' E E 33a ---AREAOFWORK---� � � I ,. . . I '. E"[fE E E �.i.�. E E� I ( O(:aH � EP � � — � E�E. � ; ; � 1g � � E � ���� 333 � � � -------- --1 �'EN N�OMB� 1 � � ,��.�_:fi 330 EIEI.... 332 ` E— � _ _ _ _ _ _ _ _ _ � acr� 1 � � � E � � � ECH � � N �� � � 301 � I 302 I � � E I �/ �- � �L �� � FJR� i�,�E ��— AREAOFWORK--� / � / S � LAW SUITE (325) i��i TRAVELERS SUITE (300) POWER/COMMUNICATIONS LEGEND SYMBOL DESCRIPTION .) WALLMOUNTEDDUPLEXELECTRICALOUTLEf =i�E WALLMOUNTEDDUPLEXELECTRICALOUTLETWITH�2)USBPORTS WALL MOUNTED DEDICATED DUPLEX ELECTRICAL CIRCUIT, NEMA PLUG WHEFENOTED Ir�- WALLMOUNTED�UADPLEXELECTRICALOUTLET,125VOLT,ISAMP I,.q WALLMOUNTEDDATAOUTLET.SUBSCRIPTINDICATESNUMBEROF ��� CONNECTION POFTS I,� WALLMOUNTEDCOMBINATIONVOICE/DATAOUTLET.SUBSCFIPT INDICATES Nl1M6ER OF CONNECTION PORTS W IREMOLD RC4 SERIES FU1SH MOl1NTED ELECTRICAL Fl1RNITl1RE y FEEDFLOORCOREDEVICE.GCTOENSURETOMATCHEXISTINGON SITE � WIREMOLD RC4 SERIES FLUSH MOUNTED DATA FURNITURE FEED � FLOOR CORE DEVICE GC TO ENSURE TO MATCH EXISTING ON SITE WIREMOLD RC4 SERIES COMBINATION ELECTRICALAND DATA FU1SH FLOOR MOUNTED DEVICE TO PROVIDE (2) DUPLIX, (2) CAT 6a srr SHIELDEDAVCABLESAND(2)NEfWORKDROPSFORDIRECTPLUG INCONNECTIONS. PROVIDE�1)CONDUITFORDATA/CAT6aAV CABLESAND (1) CONDUIT FOR POWER CONNECTION TO RUN FROM FLOOR BOX CONNECTION TO WALL WITH NCONNECTION. COMBINATION ELECTRICALAND DATA DIRECT PLUG IN L•J CONNECTIONSCONTAMEDWITHINCONNECTFACSVSTEMTO PROVIDE (2) Dl1PLEX, (2) CAT 6e SHIELDED CABLES AND (1) NEfWORK DROP. �:J�F WALLMOUNTEDJ-BOXFORELECTRICALFURNITUREFEED luc. WALLMOl1NTEDLOWVOLTAGEFl1RNITl1REFEEDJ-BOX I.... N (1) CAT6 DATA DROPTERMINATEDATONE END WITH BLUE RJ45 NETWORK PORT AT WALL RECEPTACLE (1) CAT 6 DATA DROP TERMINATED AT ONE END WITH BUIE RJ45 NETWORK PORT AT WALL RECEPTACLE TO RUN BACK TO CABLE CLOSEf, AND (2) CAT 6a SHIELDED AV CABLES TO RUN FROM TV TO I������ D FLOOR BOX CONNECTION AT TABLE CABLE TO BE UNTERMINATED W ITH 5'-0" SLACK AT N MOUNT LOCATION AND 15-0" SLACK LEFT AT FLOOR BOX �, WALL MOUNTED PANIC BUTTON TO REMAIN VI WALLMOUNTEDVIDEOINTERCOM � SECURITYACCESSCARDREADERASSEMBLV. PROVIDEDAND �� INSTALLEDBVCLIENT'SSECURIT'VENDOR ANNOTATION TYPES E 'E' DENOTES EXISTING ITEM TO REMAIN R 'R' DENOTES ITEM TO BE RELOCATED NOTES'. OUTLET tl I.��. f� 1.00TLET�EVICEFlNISHESTOMATCHEXISTING,O.O.N. SPAQNG I`� 20lITLBCWERPLATEFlNISHESTOMATCHEXISTING, qTOFRCE ❑.O.N. LOCATIONS. , ��ryl \ 3.OlITLBSTOBEMOIIME�AT1'�6"AFFTOCEMERLWE TYP.U.N.O. I oF o�r�Er � o N. POWER/COMMUNICATIONS NOTES: • REFERENCE SHEET G0.0, G0.1, G03, AN D G0.4 FOR APPLICABLE GENERAL NOTES, SPECIFICATIONS AND ALTERNATES. • BULLETED NOTES AFE GENEFAL CONDITIONS FEQUIFED FOF THE PLAN. NUMBERED NOTATIONS REFERENCESPECIFlC LOCATIONS ON THE DRAWINGS. • EXISTING CONDITION INFORMATION HAS BEEN BASED ON AS-BWLT DRAWINGS. THE GENERAL CONTRACTOR SHALL FlELD VERIFv ALL MEASUREMENTS, LOCATIONS AND CHARACTERISTICS OF ALL WORK AN D EpUIPMENT AND COORDINATE WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF RELATED WORK. • FEVIEW ENGMEEFING DFAWINGS IN CONJUNCTION WITH AFCHITECTUFAL PLANS AND COORDINATE WORK TO INCUIDE REp W REMENTS FOR BOTH DISCIPLMES. COORDINATE ANV DISCREPANCIES WITH itlGROUP. • SPACE WILL BE OCCUPIED DUFING ALTEFATIONS. CONTFACTOF TO PFOVIDE A BARRIER AT AREA OF WORK - TO CONTROL NOISE AND Dl1ST. ONLV p W ET WORK CAN TAKE PLACE DURING BUSINESS HOURS. • WFITTEN DIMENSIONS TAKE PFECEDENCE OVEF SCALED DIMENSIONS ON THE CONSTRUCTION DOCUMENTS. • ALL DIMENSIONS ARE FROM FINISHED FACE TO FINISH ED FACE, U ON. • ALL APPLICABLE CODES AND FEGULATIONS SHALL BE COMPLIED WITH. • ALL ELECTRICAL OURETS PLACED WITHIN 6'-0" OF A WATER SUPPLV SHALL BE GFl. ENSURE EXISTING MEETS THESE REQUIREMENTS WHERE APPLICABLE. • ALL NEW OUTLETS SHOWN ABOVE COUNTER TO BE HORIZONTALLV MOUNTED 42" AF.F. TO CENTER OF OURET, U.O.N. • NEW DATA CABLING LINES MUST BE PROPERLV SECURED AND NOT RESTING ON CEILING GRID. • ALL ELECTFICAL NOT SHOWN AFE EXISTING TO FEMAIN, U.O.N. • ALL Ol1TLETS ARE NEW, LLO.N. • ALL ELECTRICAL DEVICES TO BE CLEARLV LABELED ON THE COVER PLATE WITH PANEL AND CIRCUIT NUMBERS. THIS INCLUDES ALL ELECTRICAL DEVICES WITHIN THE SPACE ALONG WITH CORE DRILLS AND Fl1RNITl1RE WHIPS. • ELECTRICIAN TO PROVIDE J-BOX AND RING AND STRING AT ALL NEW CABLING LOCATIONS AHEAD OF LOW VOLTAGE CABLE INSTALLEF. AT EACH LOCATION FOF NEW TELEPHONE AND/OR DATA LOCATIONS, CONTRACTOR TO PROVIDE AND INSTALLJ-BOX,PULLSTRINGANDGROMMETATTOPOFTRACK LOCATIONS SHOW ING A COMBINATION TELEPHONE/DATA OUTLEf, THE CONTRACTOR SHALL PROVIDE AND W STALL J-BOX AND (2) PULL STRINGS. ALL PHONE AND DATA CABLES MUST BE SECURELV TAGGED. CONTACT CBRE CONSTRUCTION PROJECT MANAGER IF VOU HAVE ANV pUESTI0N5. • PFOVIDE ELECTFICAL SEFVICE FOF UNDEFCABMET HOT WATEF SOUFCE. REFERENCE ENGMEERING DRAWINGS FOR EXACT LOCATION. •VERIFY ALL FLOOR PENETRATIONS WITH itlGROUP PRIOR TO INSTALLATION. X-RAV SIAB AS FEQUIFED AND OBTAIN W FITTEN AUTHOFIZATION OF LOCATION FFOM PROPERTY MANAGER. ALL LOCATIONS TO BE IDENTIFIED AND APPROVED BV CBRE PROJECT MANAGER AND idGROUP PRIOR TO INSTALLATION. ALL PENETRATIONS TO BE SEALED PEF APPLICABLE CODE ALL COFE LOCATIONS TO HAVE 3/4" CONTINl10l1S METAL COND WT FROM CORE TO WALL WITH TV MOl1NT OR NEAREST WALL IF N IS NOT PRESENT, U ON. IF SITE CONDITIONS PROHIBITS LOCATION AS INDICATED, GC TO NOTIFV itlGROUP FOR ALTERNATE LOCATION. • ALL ELECTRICAL OURETS AND VOICE/DATA OURETS TO BE OFFSET WITHIN WALLS AND NOT INSTALLED BACK TO BACK. • W ITHIN APEA OF WORK, VEPIFV ALL EXISTING OUTLEfS FUNCTION AS INTEN DED. FEPAIF AS FEQUIFED. • WITHIN AREAOF WORK, REMOVEANV EXISTING OUTLETS NOTSHOWN ON PLAN THAT ARE LOCATED ABOVE 24" AFF. • PFOVIDE A GFEENFlELD REXIBLE CONDUIT AT VOICE/DATA ALONG PEFIMETEF OF SPACE,ASNEEDED. • EXISTING OUTLETS WITHIN 1'-0" OF A NEW OUTLET OF THE SAME 11'PES AS INDICATED ON PLAN AFE TO FEMAIN IN LIEU OF THE NEW OUTLEf. • ALL DATA CABLING TO BE PROVIDED AND MSTALLED BV TRAVELERS' CABLING VENDOR. CABLING VENDOR TO VERIFY ALL REQUIREMENTS. itlGROUP IS NOT PESPONSIBLE FOR �UANTIT' OP CABLE LENGTHS NEEDED FOR NEW PULLS. • SVSTEMS FURNITURE IS A FOUR CIRCUIT SVSTEM THAT SPREADS OUT TH E POWER ACROSS LINES 1, 2, 3, AND 4 TO SERVICE A MAXIMUM OF (9) CUBES PER FEED. IT IS ESTIMATED THAT EACH CUBE WILL PULL 5 AMPS OF POWER. REFERENCE SVSTEMS FURNITURE WIRING SCHEMATIC AND TVPICAL POWER LAVOUT ON 14 & 15/ABA FOR ADDITIONAL INFORMATION. • ELECTPICIAN IS PESPONSIBLE FOP MAKING FlNAL CONNECTIONS TO SVSTEMS FUFNITUFE W HIPS SHALL BE AVAIIABLE TO ELECTFICIAN AT TIME OF FUFNITUFE INSTALLATION. WHIPS WILL BE HARDWIRED TO WALL JUNCTION OR CORE JUNCTIONS AS NOTED ON PLAN. • FEFEFENCE ASSOCIATED SHEET SEFIES A23 FOF ADDITIONAL MFOFMATION. f1AIR #1 � 1 �����i ���—� � E �'; ; E E ;._',� 1 E ,._', � � 1 i �1� 342 . EVF 1 . Fti -, � _ _ — _ — _ _ _ E�_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ � f E 1 i 3'=°°� i �� � y � 311 � �-� � '7e q�_�. q�_�. p3• 310 i ^___ ____� 345 � .� '� ' o � � �:� '�E .i� � �� � � �, �� e � _ _ . 0 � � �' �� OO , a,o. � �' � I 6 � 6 iW ��_3� �_6*3�3�� 3_ �� / / i � � �!4' � � � � � � I lE� '•E�.�� �A N\W� i�..�s�� eo W� 38�• I .ns O � +6�5,3N/4" _ � � � � � � p w 1] .� in E � -`y' � 308 �� a 38" I ,.t._��t � � 346 +� �.+ O � � � - � �� �_6.� 3 �`oa______________ AREAOFWORK _----------- // JJ E �•�E�E •�EGE / / / I J. e � I ".�� 306 E �` F � � �t I �? � �m � ,, � L4J,� _ _ _ ;E C _ 1 _ UJ.,E _ — ,, i � �� � �' � ` ��,� �. �,�,� aw�q �� �o �..; .�,I \�� �r`E � � � .. �J �=V �aar `o � �� a I� ���� , e� � s � E l� � �,m -1 „-J #�oa ,�n ,�ns �� 1 EE J pc 321 � �________� _.� � _ � � :I_i � E�r � � � � I I � 3 � I I I �r;'e I � �. I \ I .� 309 � � I I� � E�y I I �I� � I_ � � � � � i E11�... i ELI�.�. ,..t::e 320 � � EtJ II I `--AREA OF WORK--� •.FLF •_�_F.iL • .. E E � � 314 E(� arE E � �L �u � � � -E E I;E +E EE J � ST'.IF / #3 F � - ] 1I' — � POWER & COMMUNICATIONS PLAN — 3RD FLOOR 01 0 5 ,o Zo SCALE: 1/8'• = 1'-0'• � � �;' OO POWER/COMMUNICATIONS KEYNOTES NORTH 11SED # NOTE 11SED # NOTE 1 PROVIDEWALLMOUNTEDJ-BOXFORELECTRICALSERVICETOBEHARDWIREDTOTENANTPROVIDEDSVSTEMSFURNITURE. � 13 CONVERTEXISTINGELECTRICALRECEPTACLETODEDICATEDOUTLETFORNOTEDEpUIPMENT.REFERENCEENGINEERINGDRAWINGSFOR ELECTRICIANTOPULLINATOTALOFFOURCIRCUITSTOTHENEWFURNITUREWHIPLOCATIONS.REFERENCEI4&15/ABAFOR AooITIONALMFORMATION. AND ADDITIONAL INFORMATION. 2 PROVIDEWALLMOUNTEDJ-BOXWITHRINGANDSTRINGFORLOWVOLTAGECABLINGTOPASSTHROUGHANDINTOTENANT 14 PROVIDEPOWERANDDATATHROUGHWALLANDINTOINCARPETCONNECTRACSVSTEM#IN-096-ALWITHTRANSITIONWALLADAPTERAND � PROVIDEDSVSTEMSFURNITURECONNECTIONS ANDCABLINGTOBEINSTALLEDBVTRAVELERSCABLINGVENDOR ENOTRAN51TI0NRAMPS. TERMINATIONPOINTTOPROVIDE�UADRAPLEXOUTLETAND(2)DATACONNECTIONPOINTSWITHINADECORAFACE PLATE MSTALLED W ITH W TOP COVER OF CONNECTRAC SVSTEM. � 3 GC TO ENSUFE EXISTING J-BOX CAN BE USED FOF ELECTIFCAL AND/OF DATA TO TENANT PFOVIDED FUFNITUFE SVSTEM AS 15 GC TO PFOVIDE AND INSTALL CONDUIT FOF CABLING CONNECTIONS FEQUIFED FOF CEILING MOUNTED SPFAKEFS AND PFOJECTOF FFOM SHOWN. ENSUREEXISTINGELECTRICALAND/ORDATAFALLSWITHIN6"OFPANELIFNOT,PROVIDENEW.REFERENCEI4& WALLOUTLETNOTEDONPLAN.COORDINATEWITHTRAVELERSANTEAMANDCBREPROJECTMANAGER. 15/A80 FOR ADDITIONAL MFORMATION. 4 PFOVIDEFLUSHMOUNTEDPOWEFAND/OFDATAFUFNITUFEFEEDPOKETHFOUGHDEVICETOBEHAFDWIFEDTOTENANT 16 TENANT'SAWENDOFTOPFOVIDEPOWEFCUBBVATTABLESUFFACEASNEEDEDFOFNEWFULLAVSETUPWITHINFOOM. COOFDINATE PROVIDED SVSTEMS Fl1RNITl1RE. DEVICE TO MATCH EXISTING ON SITE WITH CBRE PROJECT MANAGER PRIOR TO MSTALLATION ON SITE TO ENSl1RE WHICH TABLE TO RECENE POWER C1166V. � 5 GC TO PROVIDE POWER CONNECTION BELOW SINK FOR MSTANTANEOl1S WATER HEATER. COORDINATE WITH ENGMEERING � 1] GC TO ENSl1RECONDWT PATHWAV FROM IXISTING FLOOR CORE DEVICETO WALL WITH NEW POWER CONNECTIONS FOR WALL MOl1NTED DOCUMENTSFORADDITIONALINFORMATION. MONITORLOCATIONASSHOWN. MAKEROUTINGADJUSTMENTSASNEEDEDTOPROVIDEPROPERCONNECTIVITYNEEDEDBETNEENFLOOR BOX AND MONITOR WALL CONNECTION. � 6 PFOVIDE�2)WALLMOUNTEDDEDICATEDDUPLEXOUTLETSATMICFOWAVETOWEFS.FEFEFENCEELEVATIONSONSHEETA60 18 TENANTSCABLINGVENDOFTOCONVEFTEXISTINGBLANKPLATETONEWDATACONNECTIONFOFNEWAUDIOEQUIPMENTTOBEPFOVIDED FOR ADDITIONAL INFORMATION. AND MSTALLED BV TRAVELERS AV VENDOR. TENANT'S CABLING AND AV VENDORS TO Pl1LL ALL AV AND DATA CABLING NEEDED FOR Fl1Tl1RE INSTALLATION OF N MONITOR CONNECTIVITY WITHIN ROOM TO MATCH FULL INSTALLATION OFTENANT'S HUDDLE/CONFERENCE ROOM CONFlGUMTION. ALLCABLINGTOBECOILEDABOVECEILINGANDSUPPOPTEDOVEPHEADSOTHATCABLINGISNOTPESTINGONCEILING 3RD FLOOR ROOM SCHEDULE GRID. � ] OURETS SHOWN TO BE MOUNTED HORRONTALLV ON CENTER AT HEIGHT NOTED ON PLAN. � 19 TRAVELERS CABLING VENDOR TO COORDINATE WITH AV VENDOR TO ENSURE THAT EXISTING FLOOR CORE HAS THE APPROPRIATE ROOM ROOM ROOM ROOM DATA/VOICE CONNECTIONS NEEDED FOR NEW AUDIO EQUIPMENT. TENANT'S CABLINGANDAV VENDORS TO PULLALL AVAND DATA CABLING NUMBER ROOMNAME NUMBER ROOMNAME NUMBER ROOMNAME NUMBER ROOMNAME NEEOEOFoaFUTuaEiNSTn�unoNOFTVMONiToacoNNECTivilvwirHiNaooMTOMnrcHFuuiNSTn�urioNOFTENnNrs HUDDLE/CONFERENCEROOMCONFlGURATION. ALLCABLINGTOBECOREDABOVECEILINGANDSUPPORTEDOVERHEADSOTHATCABLING 301 qECEPTION 313 OPENAFEA 325 OFFICE 33l OFFlCE ISNOTRESTINGONCEILINGGRID. 302 CONFERENCEROOM 314 OPEANAREA 326 OPENAREA 338 OFFICE � 8 GCTOCOORDINATEINSTALLATIONOFNEWORRELOCATEDCARDREADERWITHTRAVELERSSECURITVVENDOR. 20 TENANT'SSECURITYVENDORTORELOCATETHEFOLLOWINGDEVICESTONEWWORKSTATIONASSHOWN: * VIDEO INTERCOM MASTER WITH DOOR RELEASE 303 CABLE CLOSET 315 OFFICE 32] OPEN AREA 339 OPEN AREA ' REMOTE DOOR RELEASE 304 CORRIDOR 316 CONFERENCE ROOM 328 OFFICE 340 OFFICE ' PANIC Bl1TTON NOTIFICATION 305 COPV/WOFKAFEA 31� OFFICE 329 OFFICE 341 OFFICE � 9 POWERANDDATARECEPTACLESNOTEDABOVEIB"A.F.F.TOBEHELDTIGHTTOEITHERSIDEOFSl1RFACEMOl1NTED6LOCKING. 21 GCTOWSTALLAL5200SERIESRACEWAVATFLOORTOBEHELDTIGHTTOMl1LLIONATIXTERIORWINDOW.GCTOPl1LLPOWERANDDATA POWERAND DATA RECEPTACLE MOUNTING HEIGHT TO BEON CENTER A.F.F. AS NOTED. GC TO CONFIRM MOUNTING HEIGHT OF DOWN COWMN TO RUN THROUGH RACWAV WHICH WILLTHEN PROVIDE POWERAND/OR DATA AS NOTEDTO FURNITURE. VERIFY LENGTHS 306 OPENAREA 318 OPENAREA 330 RECEPTION 342 OPENAREA POWEFANDDATAFECEPTAQESWITHTFAVELEFSANANDCABLEVENDOFSPFIOFTOINSTALLATION.BLOCKINGSHOWNFOF PFIOFTOOFDEFING. REFERENCE ONLV. REFERENCE APPROPRIATE SHEET SERIES A2.0 FOR ADDITIONAL INFORMATION. �m aooev eooe 319 OFFICE 331 CONFERENCE ROOM 343 OFFICE RELEASED FOR CONSTRACTION 320 OPEN AREA 332 GOAT GLOSET 344 OFFlCE 'O GO IN9TALLATION OUNTING HEIGHTOF POWERAND DATA RECEPTACLES WITH TRAVELERS ANAND CABLING VENDORS PRIOR 22 Vy0 KST CABLING VENDORTO REPULL CABLING, REMOVED FROM WORKSTATIONS AT DEMOLITION PHASE, WTO RECONFlGURED ATIONS AS SHOWN. 321 OPENAFEA 333 OPENAFFA 345 COPVAFEA �>> TENATN'SCABLINGVENDORTOENSUREEXISTINGFLOORCOREHASCAPACITVFOR�1)DUPLEXRECEPTACLECAT6,ry)DATA � 23 TENANT'SCABLINGVENDORTOMODIFVEXISTINGCABLINGWITHINMODIFIEDWORKSTATIONCONFIGURATIONSASSHOWN.REMOVEANV Su6jec��ocompliancewithallregula�ions CONNECTIONWITHBLUEFJ45TEFMINATIONATFLOOFCOFEANDWIFEBACKTOWIFINGCLOSET,�2)CAT6SWELDEDDATA UNUSEDCABLINGBACKTOSOUFCEOFPULLNEWCABLINGASNEEDEDOUTOFEXISTINGCABLINGCLOSETS. ofSla�eantlLocalCodes 322 CONFERENCEROOM 334 GOPV�INORKAREA 346 CONFERENCEROOM CONNECTIONWITHBLACKRJ45TERMINATIONATEACHENDCONNECTEDBETWEENFLOORCOREANDWALLDEVICEGCTO CilyofCarmel 323 OFFICE 335 BREAKROOM 34� OFFICE INSTALLPULLSTRINGBETNEENWALLCONNECTIONTOFLOORCORE. " 12 ENSUREALLELECTRICALATDEMISED'GIVE-BACK"SPACEISCOMPLETELVSEPARATEDFROMTRAVELERS'RETAINEDSUITE. � 24 GCTOPROVIDEJUNCTIONBOXWITHPULLSTRINGFORVIDEOINTERCOMEQUIPMENTTOBEINSTALLEDBVTENANT'SSECURITYVENDOR �.`�i,\�'`�,��,�ti�fl 324 OFFICE 336 OFFICE REFEPENCEENGMEERINGDRAWINGSFORADDITIONALMFORMATION. � onrE: 12/09/19 339 E, ,I 34] 303 IcH E 'E 305 PPOJELT COOPDINATOP� DESIGN CONSULTAN7 / 1 % id 2fi41 IRVING BLVD. DALLA$ TEXAS �520� TEL: 214-638-6800 AFCNIiECii ErvG W EEF �PP�_ D� MC�''-.. , �Q, P�G\STEqeQ -9�': � I� No. AR11800034 �! � aRo�eci No.: DRAWN BY'. CHECKEDBY: TRAVELERB PROJECTY: io.ia.is ms oao MPNP HN/NC/CM P18 0312 ...�'� __f LI �n �� � � � � � � INDIANAPOLIS SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1ST, 2ND, & 3RD FLOOR INDIANAPOLIS, IN 46240 NO. REVISIONS'. DATP. LAN�LOR�REVIEWISSUE�ATE 10]4]9 TENANTREVIEWISSUEDATH 1008.19 eioissueonTe. m.�n.is PERMITISSUE�ATE 10]4]9 CONSTRUCTIONISSUEDATH %%�%%2019 �RAWING TITLE: POWER & COMMUNICATIONS PLAN - 3RD FLOOR DRAWING NUMBER. � A2.2 3 �O 2019 idGROUP, LLC