Loading...
HomeMy WebLinkAboutA2.3-2 Reflected Ceiling Plan- 2nd Floor0 5 ,P ZP � NORTH C 219 ' � I .���� 9'-0' AFF V.I.F. �� 202 � ✓v 9-� V.I.F. � � OJ� N 206 � �N � � ��� � J J J a < < � � � 3 � \�������� \ \ � � 20] � < � � � � 9'-0'•AFF I 9'-0"AFF V.I.F. I V.I.F. � I. � \�������� \ � „ � „ ,-, ,. .f i. „ � J < � � • — 9-0"AFF VIF. � � � C � �N 208 � N /�%N \ \ � \ \ \ \ �\\\�� 0 STP'� 3 � RENOVATION AREA OF WORK ���i GIVE BACK SPACE REFLECTED CEILING PLAN NOTES: • PEFEPENCE SHEEf GO 0, G0.1, G0.3, AN D GOA FOP APPLICABLE GENEPAL NOTES, SPECIFlCATIONSANDALTERNATES. • BULLETED NOTES ARE GENERAL CONDITIONS FOR PLAN. NUMBERED NOTATIONS REFERENCE SPEQFlC LOCATIONS ON THE DPAWINGS. • CONTRACTOR TO FlELD VERIFV ALL EXISTING CONDITIONS PRIOR TO PRICING AND CONSTRUCTION AND NOTIFY idGROUP OF ANV DISCREPANCIES. • REVIEW ENGMEEPING DOCUMENTS IN CONJUNCTION WITH ARCHITECTUML PLANS AND COORDINATE WORK TO INCLUDE REpUIREMENTS OF BOTH DISCIPLINES. • SPACE WILL BE OCCUPIED DURING ALTERATIONS. CONTRACTOR TO PROVIDE A BARRIER AT AREA OF WORK - TO CONTROL NOISE AND DUST. ONLV �UIET WOFK CAN TAKE PLACE DORING BOSMESS HOORS. • ALL APPLICABLE CODES AND REGULATIONS SHALL BE COMPLIED WITH. • NOTIFV itlGFOUP OF LIGHTING CHANGES OR DISWEPANQES IN LIGHTING LOCATIONSANDSPECIFICATIONS. PROVIDEAS-BOILTWRITTENINFORMATIONOR DRAWING WITH NOTED CHANGES. • ALL CEILING MOUNTED ELEMENST (i.e.: LIGHTS, HVAC DIFFUSERS AND RETURN GRILLES, SPRINKLER HEADS, WiFi DEVICES, AND FlREAND LIFESAFETV DEVICES) TO REMAIN, U.O.N. • PERIMEfER OR CONTINUOUS SLOT DIFFUSERS ARE NOT TO BE CONTINUOUS OVER PAFTITIONS TO CEILING OR THROUGH PARTITIONS TO DECK. • FIRE PROTECTION CONTRACTOR TO VERIFY REQUIREMENTS AND QUANTITV OF FlPE PPOTECTION DEVICES, INCLUDING SMOKE DEfECTOPS, FlPEALAPMS, SPEAKERS, STROBES, ETC. INCLUDE COSTS TO TIE SUCH DEVICES W TO BOILDING PANEL CORRENT LOCATIONS FOR SOCH DEVICES SHOWN ON PLAN ARE EITHER THEIR EXISTING PLACEMENT OR PREFERRED LOCATION. FINAL PLACEMENT OF THESE DEVICES TO MEET ALL CODE, LOCAL, AND ACCESSIBILITV REp01REMENTS. COORDINATE FINAL LOCATIONS WITH itlGROOP. • RELOCATE ANV HORNS OR STROBES AFFECTED BV DEMOLITION AND/OR NEW CONSTPUCTION TO COMPLV WITH CUPPENT LIFE SAFET' PE�UIPEMENTS. PROVIDE NEW HORNS AND STROBES AS NEEDED TO MATCH EXISTING ON SITE. • HORNS AND STROBES TO BE LOCATED IN ROOMS DIRECTLV ABOVE SWITCHES, IN ENCLOSED POOMS WHEPE PE�UIPED. • SWITCHES SHOWN INDICATE PFEFEFFED LOCATION ONLV. ALL NEW SWITCHES TO BE MOUNTED 48" A.F.F. TO CENTERLINE OF SWITCH. ALL SWITCHES TO BE GANGED TOGETHER UNDER ONE COVER PLATE FlNAL PLACEMENT TO BE COORDINATED WITH ENGMEERING DOCUMENTS AND CBRE PROJECT MANAGER • 24-HOOR LIGHT FIXTORES MOST BE TIED TO BOILDING'S EMERGENCV CIRCOITS OR FITTED WITH BATTERV BACK-UP. • NEW AND/OF FELOCATED SPFINKLEF HFADS AFE TO BE PLACED WITHIN 3" OF CENTER OF CEILING TILES AND NOT ON GRID LMES. • NEW CEILING GRIDTO BECENTERED WITHIN ROOM, UAN. • PEFEPENCE ENGMEEPING DOCUMENTS FOP LOCATIONS OF NEW/PELOCATED Bl11LDING STANDARD THERMOSTATS AS REpl11RED. IN ROOMS WITH THERMOSTATS,PLACESWITCHESANDTHERMOSTAT56"APARTANDADJACENT TO DOOP. • REPLACE ANV STAW ED OR DAMAGED IXISTING HVAC DIFFUSERS IN AREA OF WORK. GROUPAIJKE ITEMS IN ROOMS WHERE MORETHAN ONE OCCURS. • NEW AND/OR EXISTING GVPSUM BOARD CEILING/HEADERS TO BE PAINTED "PT4;' U.O.N. REFERENCE SHEET SERIES A2b FOR ADDITIONAL MFORMATION. • RELOCATE EXIT SIGNAGE AFFECTED BV DEMOLITION AND/OR NEW CONSTRUCTION. NEW LOCATIONSARETO COMPLV WITH CURRENT CODE FE�UIFEMENTS. ANV NEW SIGNS FE�UIFEDAFETO MATCH IXISTING ON SITE. REFERENCE ENGMEERING DRAW INGS ADDITIONAL INFORMATION. • REPLACE ANV STAINED OR DAMAGED CEILING TILES TO MATCH EXISTING. GC TO ALLOW FOP AN ADDITIONAL 100 SF OF PEPLACEMENT CEILING TILES FOP ATTIC STOCK IN ADDITION TO TILES REp01RED FOR NEW/PATCHED GRID/TILE. • PATCH/REPAIR GRID TO "LIKE NEW" CONDITION WHERE AFFECTED BV WALL DEMOLITION. • RELAMP ANV IXISTING TO REMAIN AND/OR RELOCATED LIGHT FlXTURES THROUGHOUT LEASE PREMISES. GC TO ENSURE ALL BALLASTS ARE IN PROPER WORKINGOPDEPANDSHALLPEPLACEASNEEDED. GCTOPPOVIDESEPAPATE LIN E ITEM PRICING FOR THIS SCOPE WITHIN BID. f i. � \\\\\\\\\ \ \ � REFLECTED CEILING PLAN - 2ND FLOOR SCALE 1/e" = 1'-0" PPOJELT COOPDINATOP� DESIGN CONSULTANT / 1 % id 2fi41 IRVING BLVD. DALLA$ TEXAS �520� TEL: 214-638-6800 AFCHIiECiiErvGIrvEEF ;+'QP� . D: .M�'� �''•. J�Q, , P�G\ST EFFQ -9�: � I� No. AR11800031 �! • aRo�eci No.: DRAWN BY'. CHECKEDBY: TRnVE�ERs aRo�ECTn: 10.14.19 aas oao MPNP HN/NC/CM P18 0312 , � L1J n�1 �� � � � � � � INDIANAPOLIS SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1ST, 2ND, & 3RD FLOOR INDIANAPOLIS, IN 46240 NO. REVISIONS'. DATP. 2ND FLOOR KEY PLAN STAIR #2 � �9-0" AFF V.I.F. 223 p ��1 — S'� � 22� ELEC inaa � � � � 8�-0• I. 8�-0• I. 0�-0• ,0�_p�. �` � � � � � �� � 218 WOMEN -",I N � 201 �♦ � \\\\� � STAIR #1 2ND FLOOR ROOM SCHEDULE NUMBER ROOMNAME NUMBER ROOMNAME 201 qECEPTION 212 OFFlCE 202 CONFERENCEROOM 213 OFFlCE 203 SERVER ROOM 214 OFFICE 204 CORRIDOR 215 OPENAREA 205 OPENAREA 216 OPENAREA 206 OPENAREA 211 OPENAREA 218 OPENAREA RELEA$ED FOR CONSTRACTION z�s secuReosTORn�e Su6jec��ocompliancewithallregula�ions 220 COFFIDOF of Sla�e antl Local Codes pp� OPEN AREA CilyofCarmel ppp EVIDENCECLOSET � � � I '�OOM 223 MAILROOM `��¢m�' lamn�M� � onrE: 12/09/19 CEILING LEGEND � EXISTING2'X2'CEILINGGFIDANDTRETO DIRECT/INDIRECTSUSPENDEDFWORESCENT FEMAIN LIGHT FIXTUFE NEW2'X2'CEILINGGRIDANDTILETOMATCH RECESSEDCOMPACTFWORESCENT EXISTING � DOWNLIGHTFIXTUFE � EXISTING5/8"GVPSUMBOARDCEILING/ CEILINGMOUNTEDPENDANTFLUORESCENT SOFFIT TO REMAIN LIGHT FIXTURE m 1'X2'�4)CELLPARABOLICADJUSTABLE F�., EWALLMOONTEDAODIO/VISOALALARM FLUORESCENTLIGHTFlXTURE � I� STROBE/HORN � 2' X 4' (18) CELL PARABOLIC FLUORESCENT LIGHT FlXTUPE Q CEILING MOUNTED WIFI DEVICE � LIGHT(FXCUREPARABOLICFLUORESCENT �/,-../� CEILINGMOUNTEDEXITSIGN. REFERENCE �. ENGMEEFING DOCUMENTS FOF ADDITIONAL INFORMATION THERMOSTAT MOONTED AT 48" AFF, O.O.N. � 1'X4'SUSPENDEDLEDLIGHTFIXTURE � REFERENCEENGINEERINGDOCUMENTSFOR ADDITIONAL INFOPMATION. NOTF I. COORDINATCLOGATIONO�SPRINKLCFHCA�SWITHLIGHTS&MCCH�NIGILGRILLCS. 2 COOH�INA I L �LL W FO FOH CLIIJNG LLLM W I S WI I N W GI�LLHIVG �OCl1MLV I S. Iq ���� 3. UPPEPCASE INDICATES FlXTUPET'PE LOWEPCASE INDICATES CIPCUITING. PEFERENCE LIGHTING SCHEDULE I't'' b�I uGHlswilcN�MouNl�ae•nFFu.o.N.> � RCP KEYNOTES (n COLOPTOMATCHBUILDINGSTANDAPD, U.O.N. USED # NOTE 3 3-POLELIGHTSWITCH(MOUNT@48" � GCTOPFOVIDEPOWEFINCEILINGFOFTENANTPFOVIDEDAND {{} AFF U.O.N ) COLOR TO MATCH BUILDING MSTALLED CEILING MOONTED PROJECTOR. COORDINATE EXACT STANDARD, U.O.N. PLACEMENT WITH TENANT'S AV VENDOR AND CBRE PROJECT MANAGER PPIOP TO INSTALLATION. 2 GCTOPFOVIDEBLOCKINGABOVECEILINGFOFTENANTPFOVIDEDAND ABOVECEILINGMOUNTEDJ-BOX INSTALLEDPROJECTORMOUNT. COORDINATEEXACTPLACEMENTWITH {'�C TENANT'S AV VENDOR AND CBRE PROJECT MANAGER PRIOR TO INSTALLATION. � 3 FECIFCUIT LIGHTING WITH EXISTINGTO FEMAIN OPEN AFFA LIGHTING CEILING MOUNTED DUPLEXOURET AS NEEDED DOE TO NEW CONSTROCTION. � 4 PROVIDEJ-BOXWITHPOLLSTRINGABOVECEILINGFORLOWVOLTAGE �X'-X"AFF CEILINGHEIGHTABOVEFINISHFLOOR CABLINGTOTENANTPROVIDEDSECURITVHARDWARE. V.LF � 5 RE-CIRCUITIJGHTSWITHINROOMASSHOWN. REFERENCE ENGMEEFING DOGUMENTS FOFADDITIONAL MFOFMATION. N 'N' DENOTES NEW ITEM � 6 NEW CEILING GFID AND TRE SVSTEM TO BE INSTALLED IN THIS FOOM TO MATCH BUILDING STANDARD. � ] GCTOENSOREALLLIGHTINGANDHVACEp01MENT,INCLODINGALL R 'R' DENOTES ITEM TO BE RELOCATED CONTROLS REMAINING IN THE GIVE BACK SPACE ARE SEPARATED FROM THEFEMAININGTFAVELEFSSUITE. FEMAININGSPACEISTOBELEFT FUNCTIONALANDCODECOMPLIANT. REFERENCE ENGMEERING DRAWINGS FOR ADDITIONAL INFORMATION. � 8 EXISTINGSUSPENDEDDECORATIVEMETALCEILINGELEMENTTOREMAIN GC TO PPOTECT IN PLACE DUPING ALL PHASES OF CONSTPUCTION. R 1, i 9'-0"AFF V.LF. I �I � � zo3 �FF i � �.�� � . i..ii iu 'u.r \ \ � : � 9'-0"AFF V.I.F. I ■ I I205 I � �� � I J � J 3 < < 3 � 6"AFF � � HDR. � �R ALIGP \\\\\\ \ \\ LAN�LOR� REVIEW ISSUE �ATE 10.14.19 TENANT REVIEW ISSUE DATE: 1008.19 eioissueonie. m.�a.is vERMiTissuEonTE: io.ia.is CONSTRUCTIONISSUEDATH %%�%%2019 �RAWING TITLE: REFLECTED CEILING PLAN - 2ND FLOOR DRAWING NUMBER. A2.3-2 �O 2019 idGROUP, LLC