HomeMy WebLinkAboutA2.3-2 Reflected Ceiling Plan- 2nd Floor0 5 ,P ZP �
NORTH
C
219 '
� I
.����
9'-0' AFF
V.I.F.
��
202
�
✓v
9-�
V.I.F.
�
�
OJ� N
206 � �N
� � ��� �
J J J
a < <
� � � 3
�
\��������
\
\ �
�
20]
�
<
�
� �
� 9'-0'•AFF I 9'-0"AFF
V.I.F. I V.I.F.
� I. �
\��������
\ �
„ � „ ,-, ,. .f i. „
�
J
<
� �
• —
9-0"AFF
VIF.
� � � C �
�N
208
� N
/�%N
\
\
�
\
\
\
\
�\\\��
0
STP'�
3
� RENOVATION AREA OF WORK
���i GIVE BACK SPACE
REFLECTED CEILING PLAN NOTES:
• PEFEPENCE SHEEf GO 0, G0.1, G0.3, AN D GOA FOP APPLICABLE GENEPAL NOTES,
SPECIFlCATIONSANDALTERNATES.
• BULLETED NOTES ARE GENERAL CONDITIONS FOR PLAN. NUMBERED NOTATIONS
REFERENCE SPEQFlC LOCATIONS ON THE DPAWINGS.
• CONTRACTOR TO FlELD VERIFV ALL EXISTING CONDITIONS PRIOR TO PRICING
AND CONSTRUCTION AND NOTIFY idGROUP OF ANV DISCREPANCIES.
• REVIEW ENGMEEPING DOCUMENTS IN CONJUNCTION WITH ARCHITECTUML
PLANS AND COORDINATE WORK TO INCLUDE REpUIREMENTS OF BOTH
DISCIPLINES.
• SPACE WILL BE OCCUPIED DURING ALTERATIONS. CONTRACTOR TO PROVIDE A
BARRIER AT AREA OF WORK - TO CONTROL NOISE AND DUST. ONLV �UIET WOFK
CAN TAKE PLACE DORING BOSMESS HOORS.
• ALL APPLICABLE CODES AND REGULATIONS SHALL BE COMPLIED WITH.
• NOTIFV itlGFOUP OF LIGHTING CHANGES OR DISWEPANQES IN LIGHTING
LOCATIONSANDSPECIFICATIONS. PROVIDEAS-BOILTWRITTENINFORMATIONOR
DRAWING WITH NOTED CHANGES.
• ALL CEILING MOUNTED ELEMENST (i.e.: LIGHTS, HVAC DIFFUSERS AND RETURN
GRILLES, SPRINKLER HEADS, WiFi DEVICES, AND FlREAND LIFESAFETV DEVICES)
TO REMAIN, U.O.N.
• PERIMEfER OR CONTINUOUS SLOT DIFFUSERS ARE NOT TO BE CONTINUOUS
OVER PAFTITIONS TO CEILING OR THROUGH PARTITIONS TO DECK.
• FIRE PROTECTION CONTRACTOR TO VERIFY REQUIREMENTS AND QUANTITV OF
FlPE PPOTECTION DEVICES, INCLUDING SMOKE DEfECTOPS, FlPEALAPMS,
SPEAKERS, STROBES, ETC. INCLUDE COSTS TO TIE SUCH DEVICES W TO
BOILDING PANEL CORRENT LOCATIONS FOR SOCH DEVICES SHOWN ON PLAN
ARE EITHER THEIR EXISTING PLACEMENT OR PREFERRED LOCATION. FINAL
PLACEMENT OF THESE DEVICES TO MEET ALL CODE, LOCAL, AND ACCESSIBILITV
REp01REMENTS. COORDINATE FINAL LOCATIONS WITH itlGROOP.
• RELOCATE ANV HORNS OR STROBES AFFECTED BV DEMOLITION AND/OR NEW
CONSTPUCTION TO COMPLV WITH CUPPENT LIFE SAFET' PE�UIPEMENTS.
PROVIDE NEW HORNS AND STROBES AS NEEDED TO MATCH EXISTING ON SITE.
• HORNS AND STROBES TO BE LOCATED IN ROOMS DIRECTLV ABOVE SWITCHES, IN
ENCLOSED POOMS WHEPE PE�UIPED.
• SWITCHES SHOWN INDICATE PFEFEFFED LOCATION ONLV. ALL NEW SWITCHES
TO BE MOUNTED 48" A.F.F. TO CENTERLINE OF SWITCH. ALL SWITCHES TO BE
GANGED TOGETHER UNDER ONE COVER PLATE FlNAL PLACEMENT TO BE
COORDINATED WITH ENGMEERING DOCUMENTS AND CBRE PROJECT MANAGER
• 24-HOOR LIGHT FIXTORES MOST BE TIED TO BOILDING'S EMERGENCV CIRCOITS
OR FITTED WITH BATTERV BACK-UP.
• NEW AND/OF FELOCATED SPFINKLEF HFADS AFE TO BE PLACED WITHIN 3" OF
CENTER OF CEILING TILES AND NOT ON GRID LMES.
• NEW CEILING GRIDTO BECENTERED WITHIN ROOM, UAN.
• PEFEPENCE ENGMEEPING DOCUMENTS FOP LOCATIONS OF NEW/PELOCATED
Bl11LDING STANDARD THERMOSTATS AS REpl11RED. IN ROOMS WITH
THERMOSTATS,PLACESWITCHESANDTHERMOSTAT56"APARTANDADJACENT
TO DOOP.
• REPLACE ANV STAW ED OR DAMAGED IXISTING HVAC DIFFUSERS IN AREA OF
WORK. GROUPAIJKE ITEMS IN ROOMS WHERE MORETHAN ONE OCCURS.
• NEW AND/OR EXISTING GVPSUM BOARD CEILING/HEADERS TO BE PAINTED "PT4;'
U.O.N. REFERENCE SHEET SERIES A2b FOR ADDITIONAL MFORMATION.
• RELOCATE EXIT SIGNAGE AFFECTED BV DEMOLITION AND/OR NEW
CONSTRUCTION. NEW LOCATIONSARETO COMPLV WITH CURRENT CODE
FE�UIFEMENTS. ANV NEW SIGNS FE�UIFEDAFETO MATCH IXISTING ON SITE.
REFERENCE ENGMEERING DRAW INGS ADDITIONAL INFORMATION.
• REPLACE ANV STAINED OR DAMAGED CEILING TILES TO MATCH EXISTING. GC TO
ALLOW FOP AN ADDITIONAL 100 SF OF PEPLACEMENT CEILING TILES FOP ATTIC
STOCK IN ADDITION TO TILES REp01RED FOR NEW/PATCHED GRID/TILE.
• PATCH/REPAIR GRID TO "LIKE NEW" CONDITION WHERE AFFECTED BV WALL
DEMOLITION.
• RELAMP ANV IXISTING TO REMAIN AND/OR RELOCATED LIGHT FlXTURES
THROUGHOUT LEASE PREMISES. GC TO ENSURE ALL BALLASTS ARE IN PROPER
WORKINGOPDEPANDSHALLPEPLACEASNEEDED. GCTOPPOVIDESEPAPATE
LIN E ITEM PRICING FOR THIS SCOPE WITHIN BID.
f i. �
\\\\\\\\\
\
\ �
REFLECTED CEILING PLAN - 2ND FLOOR
SCALE 1/e" = 1'-0"
PPOJELT COOPDINATOP� DESIGN CONSULTANT
/
1 %
id
2fi41 IRVING BLVD.
DALLA$ TEXAS �520�
TEL: 214-638-6800
AFCHIiECiiErvGIrvEEF
;+'QP� . D: .M�'� �''•.
J�Q, , P�G\ST EFFQ -9�:
� I� No. AR11800031 �! •
aRo�eci No.:
DRAWN BY'.
CHECKEDBY:
TRnVE�ERs aRo�ECTn:
10.14.19
aas oao
MPNP
HN/NC/CM
P18 0312
, � L1J
n�1
��
�
�
�
�
�
�
INDIANAPOLIS
SEVEN PARKWOOD
CROSSING
280 E. 96TH STREET
1ST, 2ND, & 3RD FLOOR
INDIANAPOLIS, IN 46240
NO. REVISIONS'. DATP.
2ND FLOOR KEY PLAN
STAIR
#2
�
�9-0" AFF
V.I.F.
223
p ��1
— S'�
� 22�
ELEC
inaa
� � �
� 8�-0• I. 8�-0• I. 0�-0• ,0�_p�.
�` �
� �
� � �� �
218
WOMEN
-",I
N �
201
�♦
�
\\\\�
�
STAIR
#1
2ND FLOOR ROOM SCHEDULE
NUMBER ROOMNAME NUMBER ROOMNAME
201 qECEPTION 212 OFFlCE
202 CONFERENCEROOM 213 OFFlCE
203 SERVER ROOM 214 OFFICE
204 CORRIDOR 215 OPENAREA
205 OPENAREA 216 OPENAREA
206 OPENAREA 211 OPENAREA
218 OPENAREA
RELEA$ED FOR CONSTRACTION z�s secuReosTORn�e
Su6jec��ocompliancewithallregula�ions 220 COFFIDOF
of Sla�e antl Local Codes pp� OPEN AREA
CilyofCarmel ppp EVIDENCECLOSET
� � � I '�OOM 223 MAILROOM
`��¢m�' lamn�M�
�
onrE: 12/09/19
CEILING LEGEND
� EXISTING2'X2'CEILINGGFIDANDTRETO DIRECT/INDIRECTSUSPENDEDFWORESCENT
FEMAIN LIGHT FIXTUFE
NEW2'X2'CEILINGGRIDANDTILETOMATCH RECESSEDCOMPACTFWORESCENT
EXISTING � DOWNLIGHTFIXTUFE
� EXISTING5/8"GVPSUMBOARDCEILING/ CEILINGMOUNTEDPENDANTFLUORESCENT
SOFFIT TO REMAIN LIGHT FIXTURE
m 1'X2'�4)CELLPARABOLICADJUSTABLE F�., EWALLMOONTEDAODIO/VISOALALARM
FLUORESCENTLIGHTFlXTURE � I� STROBE/HORN
� 2' X 4' (18) CELL PARABOLIC FLUORESCENT
LIGHT FlXTUPE Q CEILING MOUNTED WIFI DEVICE
� LIGHT(FXCUREPARABOLICFLUORESCENT �/,-../� CEILINGMOUNTEDEXITSIGN. REFERENCE
�. ENGMEEFING DOCUMENTS FOF ADDITIONAL
INFORMATION
THERMOSTAT MOONTED AT 48" AFF, O.O.N.
� 1'X4'SUSPENDEDLEDLIGHTFIXTURE � REFERENCEENGINEERINGDOCUMENTSFOR
ADDITIONAL INFOPMATION.
NOTF
I. COORDINATCLOGATIONO�SPRINKLCFHCA�SWITHLIGHTS&MCCH�NIGILGRILLCS.
2 COOH�INA I L �LL W FO FOH CLIIJNG LLLM W I S WI I N W GI�LLHIVG �OCl1MLV I S. Iq ����
3. UPPEPCASE INDICATES FlXTUPET'PE LOWEPCASE INDICATES CIPCUITING. PEFERENCE LIGHTING SCHEDULE I't'' b�I
uGHlswilcN�MouNl�ae•nFFu.o.N.> � RCP KEYNOTES
(n COLOPTOMATCHBUILDINGSTANDAPD,
U.O.N.
USED # NOTE
3 3-POLELIGHTSWITCH(MOUNT@48" � GCTOPFOVIDEPOWEFINCEILINGFOFTENANTPFOVIDEDAND
{{} AFF U.O.N ) COLOR TO MATCH BUILDING MSTALLED CEILING MOONTED PROJECTOR. COORDINATE EXACT
STANDARD, U.O.N. PLACEMENT WITH TENANT'S AV VENDOR AND CBRE PROJECT MANAGER
PPIOP TO INSTALLATION.
2 GCTOPFOVIDEBLOCKINGABOVECEILINGFOFTENANTPFOVIDEDAND
ABOVECEILINGMOUNTEDJ-BOX INSTALLEDPROJECTORMOUNT. COORDINATEEXACTPLACEMENTWITH
{'�C TENANT'S AV VENDOR AND CBRE PROJECT MANAGER PRIOR TO
INSTALLATION.
� 3 FECIFCUIT LIGHTING WITH EXISTINGTO FEMAIN OPEN AFFA LIGHTING
CEILING MOUNTED DUPLEXOURET AS NEEDED DOE TO NEW CONSTROCTION.
� 4 PROVIDEJ-BOXWITHPOLLSTRINGABOVECEILINGFORLOWVOLTAGE
�X'-X"AFF CEILINGHEIGHTABOVEFINISHFLOOR CABLINGTOTENANTPROVIDEDSECURITVHARDWARE.
V.LF � 5 RE-CIRCUITIJGHTSWITHINROOMASSHOWN. REFERENCE
ENGMEEFING DOGUMENTS FOFADDITIONAL MFOFMATION.
N 'N' DENOTES NEW ITEM � 6 NEW CEILING GFID AND TRE SVSTEM TO BE INSTALLED IN THIS FOOM TO
MATCH BUILDING STANDARD.
� ] GCTOENSOREALLLIGHTINGANDHVACEp01MENT,INCLODINGALL
R 'R' DENOTES ITEM TO BE RELOCATED CONTROLS REMAINING IN THE GIVE BACK SPACE ARE SEPARATED FROM
THEFEMAININGTFAVELEFSSUITE. FEMAININGSPACEISTOBELEFT
FUNCTIONALANDCODECOMPLIANT. REFERENCE ENGMEERING
DRAWINGS FOR ADDITIONAL INFORMATION.
� 8 EXISTINGSUSPENDEDDECORATIVEMETALCEILINGELEMENTTOREMAIN
GC TO PPOTECT IN PLACE DUPING ALL PHASES OF CONSTPUCTION.
R
1,
i 9'-0"AFF
V.LF.
I
�I �
� zo3
�FF i �
�.�� �
. i..ii iu 'u.r
\
\
� :
�
9'-0"AFF
V.I.F.
I ■
I
I205
I
� �� �
I J � J
3 < <
3 �
6"AFF � �
HDR.
�
�R ALIGP
\\\\\\
\ \\
LAN�LOR� REVIEW ISSUE �ATE 10.14.19
TENANT REVIEW ISSUE DATE: 1008.19
eioissueonie. m.�a.is
vERMiTissuEonTE: io.ia.is
CONSTRUCTIONISSUEDATH %%�%%2019
�RAWING TITLE:
REFLECTED CEILING
PLAN - 2ND FLOOR
DRAWING NUMBER.
A2.3-2
�O 2019 idGROUP, LLC