HomeMy WebLinkAboutE2.0-2 Power & Communications Plan- 2nd FloorvaaEcr cooaoiNnroai oEsicN coNsu�rnNr RELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�MNi� onrE: 12/09/19 RECEPTION � CORRIDOR � zo1 18 204 P]A-]8 � � �oRTH POWER 8� COMMUNICATIONS PLAN - 2ND FLOOR SCALEI/8"=1'-0" �� 0 Z 0 6' 8' GENERAL NOTES: G1. HORNS AND SiROBES i0 BE LOCAiED IN ROOMS DIRECiLY ABOVE SWITCHES W ENCLOSED ROOMS WHERE REQUIRED. G2 FIRE ALARM CONiRACiOR i0 VERIFY REQUIREMENiS AND QUANTITY OF FlRE ALARM DEVICES, INCLU�ING SMOKE DEiECTORS, FlRE ALARMS, SPEAKERS, STROBES, ETC. INCWDE COSiS i0 ilE SUCH DEVICES INiO BUILDING PANEL CURRENi LOCATIONS FOR SUCH �ENCES SHOWN ON PLAN ARE EITh'ER THEIR EXISTING PLACEMENT OR PREFERRED LOCAiION. COORDINAiE FINAL PLACEMEMS OF iHESE DEVICES WIiH idGROUP. G3. OUiLEi DEVICE AND WVER PLAiE FINISHES i0 MAiCH E%ISiING UNLESS O7HERWISE NOTE�. ca. nu E�ECTRicn� ounEn a�ncEo win�m e' oF n wn�R SUPPLY SHALL BE GFl. ENSURE EXISTING MEEiS THESE REOUIREMENTS WHERE APPLICABLE. G5. ALL NEW OUTLETS SHOWN ABOVE COUNiER TO BE HORIZONTALLY MOUNTE� AT 47' AFF TO CENTER OF OUiLET UNLE55 O7HER'MSE NOTED. G6. ALL OUTLETS ARE NEW 11NLE5S OTHERWISE NOiED. G7. ALL ELECTRICAL DENCE$ TO BE CLEARLY LABELED ON THE WVER PLATE WITH PANEL AND CIRCUIT NUMBERS. THIS INCLU�ES ALL ELECTRICAL DEVICES WITHIN iHE SPACE ALONG WITH CORE DRILLS AND FURNIIDRE wHIPS. G8. ROUGH-IN AND PONE iHROUGH i0 ALLOW FOR NEW CA6LING WHERE NECESSARY. ALL �ATA CABLING TO BE PROVIDE� AN� INSiALLED BY iRAVELERS' CABLING VENDOR. CA6LING VENDOR TO VERIFY ALL REQUIREMENTS. PROVIDE AT LEAST 1" CONDl11T FOR NEW CABLING. G9. REFERENCE SYSiEMS FURNIiURE WIRING SCHEMAiIC AND iYPICAL POWER LAYOUi ON 14 & 15/A8A FOR FURNIiURE WHIP WSTALLATION WFORMAiION. G10. ALL ELECTRICAL EQUIPMENT NOT SHOWN IS EXISTING TO REMAIN UNLE55 O7HER'MSE NOTED. G11. VERIFY ALL FLOOR PENETRATIONS WITH idGROl1P PRIOR TO INSiALLA110N. REFERENCE ARCH11EC1URAL DRAWINGS FOR AD�ITIONAL MFORMAiION. ciz REFERENCE Eo.o-q Ea.o-i, nNo Eo.o-z FaR E�Ecrnicn� SYM60L5 AN� SPECIFlCAiIONS. G13. REMOVE ALL CABLING WITHIN iHE 'GNE BACK' SPACE. G14. LEAVE POWER IN 'GIVE BACK' SPACE, ENSl1RING ALL CIRCUITS IN TRAVELERS' RETAWED SPACE AND THE 'GIVE BACK' SPACE ARE SEPARAiE. REFER i0 ED2.0-2 FOR FURiHER INFORMAiION. � KEYED NOTES: 1. CONFIRM MOUNiING HEIGHT OF POWER AND DATA RECEPTACLES WIiH iRAVELERS AV CABLING VENDORS PRIOR i0 INSiALLAiION. 2 CABLING VENDOR SHALL MODIFY EXISTING CABLING 'MTHIN MODIFlED WORKSiAiION CONFIGURAilONS AS SHOWN. REMOVE ANY UNUSE� CABLING BACK TO SOURCE OR PULL NEW CABLING AS NEEDE� OUT OF E%IS71NG CABLING CLOSETS. 3. PROVI�E JUNCTION BOX FOR FURNITURE WHIP. REFERENCE 14 & 15/A 8A FOR ADDIiIONAL MFORMAiION. 4. PROVIDE JUNCTION BOX W1TH RING & STRING FOR LOW VOLiAGE CABLING i0 PASS iHROUGH & INiO FURNIIDRE. WNNECTIONS & CABLING WSTALLED BY TRAVELERS CABLING VENDOR 5. PROVIDE FLUSH MOUME� POWER AND/OR DAiA FURNIIDRE FEED POKE 7HROUGH �ENCE TO BE HAR� WIRED TO FURNINRE. MATCH DEVICE TO EXISTING ON SITE. 6. COOR�INATE WSTALLATION OF NEW OR RELOCATE� CARD READER WITH TRAVELERS SECURITY VENDOR. 7. CABLING VENDOR SHALL ENSURE EXISTING FLOOR WRE HAS cnanatr FOR (i) ouP�ex RecePtnae cnts, (i) onrn WNNECTION WITH BWE RJ45 iERMINATION AT FLOOR CORE AND WIRE BACK TO WIRING CLOSET, (2) CAT6 SMELDED DATA WNNECTION WITH BLACK RJ45 iERMINATION AT EACH END CONNECTED BETWEEN FLOOR CORE AND WALL �EVICE GC TO INSTALL PULL SiRING BETWEEN WALL CONNECTION TO FLOOR WRE. 8. POWER AND DATA RECEPTACLES NOTED ABOVE 18" AEF. TO BE HEL� TIGHT TO EITHER SIDE OF SURFACE MOUNiED BLOCKING. POWER AND DATA RECEPTACLE MOUNTING HEIGHT TO BE ON CENTER AEE AS NOTED. GC TO CONFIRM MOUNTING HEIGHT OF POWER AND �ATA RECEPTACLES WITH TRAVELERS A/V AND CABLE VENDORS PRIOR TO WSTALLATION. 6LOCKING SHOWN FOR REFERENCE ONLY. REFERENCE APPROPRIAiE SHEEi SERIES A2.0 FOR A��ITIONAL WFORMATION. 9. GC i0 ENSURE WNDUIi PAiHWAY FROM E%ISiING FLOOR CORE �ENCE TO WALL WITH NEW POWER CONNECTIONS FOR WALL MOUNTED MONITOR LOCAiION AS SHOWN. MAKE ROU7ING ADJUSiMENiS AS NEEDED i0 PROVIOE PROPER CONNECiIVIiY NEEDE� BETWEEN FLOOR BOX AND MONITOR WALL WNNECTION. 1�. SECURIiY VENDOR SHALL RELOCAiE iHE FOLLOWING DEVICES TO NEW WORKSTATION AS SHOWN: s NDEO WTERCOM MASiER WITH DOOR RELEASE ' REMOiE DOOR RELEASE ' PANIC BUTTON NOTIFlCAiION n. iNsrnu oEoicnt�o ouner. 12. PROVIDE NEW RRE ALARM DEWCE MODIFY AND/OR ADD i0 SYSiEM AS NECESSARY TO SUPPORT �EVICE. 13. MSTALL SALVAGED FIRE ALARM DEVICE MODIFY/ADD TO SYSiEM AS NECESSARY TO SUPPORT DEwCE. 14. PROVIDE JUNCTION BOX 'MTH PULL SiRING A60VE CEILING FOR LOW VOLTAGE CABLING TO SECURITY HARDWARE COORDINATE WITH SECURITY VEN�OR. 15. INSTALL RELOCATED THERMOSTAT. COORDINATE WITH MECHANICAL. 16. CONVERT ExISTING BLANK PLAiE TO NEW DATA CONNECTION FOR NEW AUDIO EQUIPMENT PROVI�ED AND INSTALLED BY TRAVELERS AV VEN�OR. CABLING AND AV VENDORS TO PULL ALL AV AND DATA CABLING NEEDED FOR FUIDRE INSTALLATION OF TV MONITOR CONNECTIVITY WIiHIN ROOM TO MATCH FULL INSiALLAiION OR HUDDLE/WNFERENCE ROOM CONFlGURAiION. ALL CABLING TO BE COILED ABOVE CEILING AN� SUPPORiED OVERHEAD SUCH THAT CABLING IS NOT RESTING ON CEILING GRID. 17. PROVIDE DEDICATED OUTLET FOR INDICATED EQUIPMENT. 18. RECONNECT DEVICE TO NEW IN�ICATE� CIRWIT. �I � idGRC=�P 2641 IRVING BLVD. DALL45,TEXAS 75207 TEL 214-638-6800 nacw�cueNeweea 1 1 ' � MUSSETT NICHOLAS � A S S O C I A T E S Engineers +Archiiecis 502 5. wEST STREET INDIANAPOLIS, INDIANA 46225 31].6319241 59]4 51% f-0RKS ROAD, SUITE B RALEIGH, NORiH CAROLINA D609 919.]03.4028 sEn� ���""`� uu ��R ���. p�F,`� �c�sieqFQ�'q i:6 No. ��10505670 �_ � srnrz or W� �ii(�S �rvo i nH� ��: � '''�����miin� o"` � � PROJECT NO_ 2019222 DRAWN BY'. JPG cHecrceoer. oPe TRAVELER'S PROJECT IX�. P18-0312 � � � J � � a � � INDIANAPOLIS SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1 ST, 2ND, & 3RD FLOOR INDIANAPOLIS, IN 46240 oanwwc TiT�E�. POWER & COMMUNICATIONS PLAN - 2ND FLOOR �RAWINGNUMBER'. E2.0-2 OO 2019 idGROUP, LLC LANDLORD REVIEW ISSUE DATE�. 10.14.19 TENANT REVIE W ISSUE �ATE�. 10.08.19 BIDISSUEDATE' 10.10.19 PERMIT ISSUE DATE�. 10.14.19 corvsTaucTiorvissueonTe�. xx�xwzms