Loading...
HomeMy WebLinkAboutE2.0-3 Power & Communications Plan- 3rd FloorPFOJECL H ii Z �IAIF «, � � � � � ,� STr�IR #2 � .� .�I. WORK AREA 334 ) PANEL 'P3�'- ELEG � � -� � 1 I�ili� NiOMBu 1 �'� 14 N F - 10 OPEN AREA � 333 GONFEFENCE ROOM 331 �, � l4 I FECEPTION � 330 l4 ■ � ��l ` 10 RECEPTION 14 301 2 3 CORRIDOR 304 �oRTH CONFERENCE ROOM 346 COPV/WORK ARE4 305 OPEN ARE4 306 � 13 aao-u,is,ie � 1 POWER 8� COMMUNICATIONS PLAN - 3RD FLOOR s�A�E:,iB�.-,,o�. �n�'1..r� 0 T 6' B' ! OPEN 11 ARFA 309 OPEN AREA 321 13 P3U-14.1fi.1B � ♦ � OPEN AREA 314 �� F OPEN ARFA 320 � � � ST�.IR #3 GENERAL NOTES: G1. HORNS AND SiR06E5 TO BE LOCATED IN ROOMS �IRECTLY ABOVE SWITCHES W ENCLOSED ROOMS WHERE REOUIRED. G2 FIRE PROTECTION CONTRACTOR TO VERIFY REOUIREMENTS AND QUANTITY OF FlRE PROTECiION DEVICES, INCWDING SMOKE DETECTORS, FlRE ALARMS, SPEAKERS, STROBES, ETC. INCWDE COSTS TO TIE Sl1CH DEVICES INTO Bl11LDING PANEL Cl1RRENT LOCAilONS FOR SUCH �EVICES SHOWN ON PLAN ARE EIiHER iHEIR EXISTING PLACEMENT OR PREFERRED LOCATION. COORDINATE FINAL PLACEMENTS OF THESE DEVICES 'MTH idGROUP. G3. OUTLET �EVICE AND COVER PLATE FINISHES TO MATCH EXISTING UNLE55 OTHERWISE NOTED. G4. ALL ELECTRICAL OUTLETS PLACED WITHIN 6' OF A WATER SUPPLY SHALL BE GFI. ENSURE EXISiING MEEiS iHESE RE�UIREMENTS WHERE APPLICABLE. G5. ALL NEW OUiLETS SHOWN ABOVE COUNTER TO BE HORRONTALLY MOUNTE� AT 47' AFF TO CENTER OF OUTLET UNLESS OTHERWISE NOTED. G6. ALL OUiLETS ARE NEW UNLESS OiHERWISE NOTED. G7. ALL ELECTRICAL DEVICES TO BE CLEARLY LABELED ON THE COVER PLAiE WIiH PANEL AND CIRCUIi NUMBERS. iH15 MCWDES ALL ELECiRICAL �EVICES WITHIN iHE SPACE ALONG WITH CORE DRILLS AND FURNITURE WHIPS. G8. ROUGH—IN AND POKE THROl1GH TO ALLOW FOR NEW CA6LING WHERE NECESSARY. ALL DAiA CABLING i0 BE PROVIDED AND INSTALLE� BY TRAVELERS' CABLING VEN�OR. CA6LING VENDOR TO VERIFY ALL REQUIREMENTS. PROVIDE AT LEAST 1" CONDUIT FOR NEW CABLING. G9. REFERENCE SYSiEMS FURNIIDRE 'MRING SCHEMAiIC AND TYPICAL POWER LAYOUT ON 14 & 15/ABD FOR FURNITURE WHIP INSTALLAiION WFORMATION. G10. ALL ELECTRICAL EOUIPMENT NOT SHOWN IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. G11. VERIFY ALL FLOOR PENEiRATIONS WITH idGROUP PRIOR TO INSiALLAiION. REFERENCE ARCHIiECIDRAL DRAWINGS FOR A�DIiIONAL WFORMATION. ciz REFERENCE Ea.o—a, Eo.a—i, nNo Eaa—z FOR E�EcrRicn� SYMBOLS AND SPECIFICATIONS. 0 KEYED NOTES: 1. CONFIRM MOUNTING HEIGHT OF POWER AND �ATA RECEPTACLES WITH TRAVELERS AV CABLING VENDORS PRIOR TO MSTALLATION. 2 TENANT'S CABLING VEN�OR TO ENSURE EXISTING FLOOR CORE HAS CAPACITY FOR (1) DUPLE% RECEPTACLE CAT6, (1) DATA CONNECiION 'MiH BLUE RJ45 1ERMINA110N A1 FLOOR CORE AND WIRE BACK TO WIRING CLOSET, (2) CAT6 SHIELDEO DATA CONNECiION 'MiH BLACK RJ45 iERMINAiION Ai EACH END CONNECiED BETWEEN FLOOR CORE AND WALL DEVICE GC TO INSTALL PULL STRING BETWEEN WALL CONNECiION TO FLOOR CORE. 3. GC TO ENSl1RE CONDUIT PATHWAY FROM EXISTING FLOOR CORE DEVICE i0 WALL WIiH NEW POWER WNNECilONS FOR WALL MOUNTED MONITOR LOCATION AS SHOWN. MAKE ROUTING ADJUS7MENT5 AS NEEDED TO PROVIDE PROPER CONNECTIVITY NEEDE� BEiWEEN FLOOR BO% AND MONIiOR WALL CONNECiION. 4. PROVIDE HOPoZONTAL Ol1TLET WITH USB CONNECTIVITY AT INDICAiE� HEIGHi. 5. PROVIDE (2) WALL MOUNTED DEDICATED DUPLE% OUTLETS AT MICROWAVE TOWERS. REFERENCE ELEVATIONS ON SHEET A6.0 PoR ADDIiIONAL INfORMATION. 6. PROVIDE �EDICATED OUTLET FOR NOiED EQUIPMENT. 7. PROVIDE NEW 'P3D' 120/208V PANEL FE� FROM 'P3B'WITH (4) �3 &(1) j�8 IN 1-1/4"G FlELD VERIFY 7HAT IS THE BEST LOCATION. 8. PROVIDE NEW FIRE ALARM DEVICE. MODIFY AND/OR AD� TO SYSiEM AS NECESSARY i0 SUPPORi �EVICE. 9. PROVIDE THERMOSTAT. COORDINATE W1TH MECHANICAL. 10. COORDINATE WITH SECURITY VENDOR FOR NEW /RELOCATED DEVICE REQUIREMENTS. n. CABLING VENDOR SHALL MODIFY EXISTING CABLING WIiHIN MODIFlED WORNSTAiION WNFIGURAiIONS AS SHOWN. REMOVE ANY UNUSED CABLING BACK TO SOURCE OR PULL NEW CABLING AS NEEDED OUT OF EXISTING CABLING CLOSETS. 12 PROVIDE NEMA 3, D7V, 7�A, 2P DISCONNECT FOR TANKLESS WATER HEATER. REFERENCE G0.1 FOR MORE MFORMATION. 13. CONNECT JUNCTION BO% TO NEW INDICATED CIRCUIT. 14. PROVIDE JUNCiION BOX WIiH PULL STRING ABOVE CEILING FOR LOW VOLTAGE CA6LING TO SECURITY HARDWARE COORDINAiE WITH SEWRITY VENDOR. �I � id�RC�;�P 26411RVING BLVD. DALLAS,TEXAS 75207 TEL: 214-fi38-fi800 nacrviTecTieNciNeea 1 1 ' � MUSSETT NICHOLAS + A S S O C I A T F S Engineers +Archifeds 502 5. wEST STREET INDIANAPOLIS, INDIANA 46225 317.631.9241 59]45IX FORKS ROAD, SUITE B RALEIGH, NORTH CAROLINA 27609 919J03.4028 sEn� .`�`�� `O's'' oeR�9 � s� e o ��� — No. — --0 10505670 �_ "� srn�or �� ��S �ND I PNP�J \_`�� '''"'� �l� III\\ "'"\ � � vRodeci rvo.�. 2m s222 oanwrvsr dac CHECKED BY'. DPB TRAVELER'SPROJECTIX�. P100312 r., I � � � J � � a � � INDIANAPOLIS SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1 ST, 2ND, & 3RD FLOOR INDIANAPOLIS, IN 46240 DRAWING TITLP. POWER & COMMUNICATIONS PLAN - 3RD FLOOR RELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�Ml1 � onrE: 12/09/19 OPEN AFEA 339 OPEN AFEA 342 ` COPV ARFA 345 OFFICE 34] ' STOFAGE 311 � aao-is V� BREAK 12 ROOM 3oB aw-ia � $ +38" P]0-I} 6 4 +38" N T � PdD-13 �P30-13 PJO-ll F q 9 8 b 4 �P�e_, DRAWINGNUMBER'. E2.0-3 �02019 idGROUP, LLC LANDLORD REVIEWI$$UE DATE'. 10.10.19 TENANT REVIEW ISSUE �ATE�. 10.00.19 BID ISSUE �ATE�. 10.14.19 PERMITISSUE �ATE' 10.10.19 CONSTRUCTIONISSUE�ATE�. %%/%%/2019