Loading...
HomeMy WebLinkAboutG0.0 Cover Sheet & IndexVICINITY MAP I.,..., „, _. P18-0312 SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1 ST, 2ND, & 3RD FLOORS I N D IANAPO LI S, I N 46240 38,358 USF (Area of Work) Scope: Remodel SYMBOL LEGEND POOMNAME ROOM MARK 000 p� DOOR MARK �j WINDOW MAPK �Q KEVNOTE REFERENCE �-� FlNISH MAFK WALLMAPK-PEF. -n SHEETAB.OFOFWALL LJ TypES � ELEVATION X/XX.X qEFEFENCE � SECTION X/XX.X pEFEPENCE 1 4 xxx p ELEVATION PEFEPENCE ABBREVIATIONS A AMPERE A.DA. AMEFICANSWITHDISABILITIESACT A.F.F. ABOVEFINISHEDFLOOR A.HJ. AUTHORITIESHAVINGJURISDICTION ADN'L ADDITIONAL BD. BOAFD BLKG. BLOCKING CAB. CABINET CLG. CEILING CLR. CLEAROPENING COL COWMNS CONTF. CONTFACTOF DWGS. DRAWINGS E.C. EXISTING TO BE CAPPED ELEG ELECTFICAL Ep. EpUAL F.E. FIREEXTINGUISHER FEC FlFEEXTINGUISHEF CABMET FHC FIREHOSECABMET FWOP. FWOPESCENT F.P.F. FIPEPETAPDANTTPEATED FFP FlBEFGLASSFEMFOFCEDPLASTIC GA. GAIIGE GG. GENERALCONTRACTOR GWBX TVPE"X"GVPSUM BOAFD GVP.BD. GVPSIIM BOARD H.M. HOLLOWMETAL HDWP HAPDWAPE � I ALIGN TO MULLION ^ CENTERLWE _ �GRIDNo. I GPIDLINE Oa�eiiea qEFEFENCE � REVISION REVISION NUMaea REFERENCE ` I ALIGNFINISHTO EXISTING ALIGN xDIMENSION � MATCHLWE I REFER To I SHEETNO. MATCHLME I e�evniiON iN DATUM OR FLOOR �y aE�nnorvswaro I Y MniNc�ooaoa ELEVATION ' _------ STATE� �ATUM OS/AB-1 I ENL4RGEDPL4N � I DETAIL i,_ _ ; PEFEPENCE X/A5.0 I Bl11LDING � � � � SECTION FEFEFENCE HT HEIGHT HVAC HEATING, VENTILATION &AIR CONDITIONING MAX. MAXIMUM M.D.F. MEDIUM DENSITV FIBEP BOAPD MIN. MINIMUM MFF. MANUFACTUFEF NJ.C. NOTINCONTRACT NS.S. NOTTOSCALE O.C. ON CENTEF OFG. OPENING PAPT. PAPTICLE PP. PAIP PFEFAB. PFEFABFICATED PT.L. PRESSIIRETRE4TEDU1M6ER REF. REFERENCE FE�'D FE�UIFED SIM SIMIL4R S S. STAMLESS STEEL STD. STANDAFD T.B.D. TOBEDETEFMINED TVP. TVPICAL U.O.N. UNLESSOTHEPWISENOTED V VOLTS VCT VINVLCOMPOSITIONTILE V.I.F. VERIFYINFIELD W/ WITH wio wirnour WH WATEF HEATEF < naP4v�Y DD DD , f'kli .F6rewery �akeIXtyfJank nn ,c�ernllq6mup� vem �� aOjiA hWY I..ii... 0 TRAVELERS ,s����� ,�P� ���� . �1� w�:,rv. nJ; ���nec�n�J Q . . . �� Life Time Piness SITE PLAN rv;JO. a �- 34 � f_ .,<,.� �, "'fi �tn� a5 T -� TRAVELERS= _ �' �� � : e . . ' �. �� � � ��� °�� �, � . � 1 � 1 ii�� - . P df�dae� �,_� � 1' vs � I�,ryp+ Y r- .�ll.�ir... \vql� r .-� ,�/ I a` V�. •`P�n y�{ �a♦ C,•�A����� � PROJECT SUMMARY •PROJECTDESCRIPTION SEVENPARKWOODCROSSING 2B0 E. 96TH STREET 15T, 2ND, & 3RD FLOORS INDIANAPOLIS, IN 46240 TH E SCOPE OF THIS PROJECT IS A NON-STRUCTURAL INTERIOR MINOR RENOVATION OF AN EXISTING MULTbFL00F TENANT SPACE IN AN EXISTING BUILDING FOF THE ABOVE NAMED TENANT. SCOPE INCLUDES MINOR MODIFICATIONS TO THE HVAQ ELECTRICAL, AND PLUMBING AS NOTED IN PLANS. • SCOPE OF WORK 1. WORKINTHISCONTRACTINCLUDESSOMENEWFLOORANDWALLFINISHESINALTEREDAREAS ONLV. 2. WOFK INCLUDES FELOCATED WOFKSTATIONS IN OPEN OFFlCEAFEA. 3. NO CHANGETO IXISTING BASE Bl11LDING WASHROOMS, JANITOR'S CLOSETS, ETC. NO CHANGE TO BASE BUILDING PLUMBING FIXTUFES OF COUNT. • APPLICABLE BUILDING CODES JUFISDICTION CITVOFCARMEL BUILDING 20121BC 2014STATEOFINDIANA FIRE 20121FC 2014 STATE OF INDIANA PLUMBING 20121PC 20145TATEOFIN�IANA N MECHANICAL 20121MC W 20145TATEOFINDIANA w ELECTRICAL 2W6NEC � 20145TATEOFINDIANA p z GAS N/A � N/A w a ENERGV 20101NDIANAECC N/A ACCESSIBILIIY 20121BGCH.11 N/A OTHEF • BUILDING DATA ZONING CLASSIFICATION: MG MERIDIAN CORRIDOR CONSTRUCTIONTVPE IIB AUTOMATICSPRINKLERSVSTEM: VES NO FIREALARM: DE NO NUMBER OF $TORIES: 3 • PROPERTY DATA LEGAL DESCRIPTION: STATE PARCELNUMBER: PARCEL NUMBER: ACREAGE 4.36 SECTION 11, TOW NSHIP 1 �, RANGE 3 29-13-11-41]-001.003-018 16-13-11-041 ]-001.003 GENERAL NOTES BUILDING PREFERRED SUB-CONTRACTOR i. GONranCroaSNn��veaiFvn��oiMeNSioNSnNoexiSnNGCONomoNSaaioaro5rnanNGOFwoaKnNOSNn��NonFv,wwartwG,ranve�easnNorHe'�tlGaoUaoFnNvoisCaeanNCies. •HVAC:(30PTIONS)FINALSUB-CONTRACTORSELECTEDMUSTUSEONEOFTHESEVENDORS 2. DONOTSCALEDRAWINGS. WRITTENDIMENSIONSTAKEPRECEDENCEWERDRAWINGSCALE. 3. ALLDETAILSSHALLBECONSIDEREDTVPICALATSIMILARCONDITIONS. LFACH&RU$$EL CONTACT:BEN REMPE 4. CONTRHCTORHNDEHCHSUBCONTRHCTORSHHLLBERESPONSIBLEFORHHVINGCOMPLETEKNOWLEDGEOFHLLCONSTRUCTIONDOCUMENTSHNDTHERELEVHNCETOTHEWORK. FHIWRETOBEHCpUHIMEDWITHTHIS TEL31].841.]8�� KNOWLE�GE�OESNOTRELIEVERESPONSIBILITVFORPERFORMINGALLWORKPROPERLV. A��ITIONALGOMPENSATIONSHALLNOTBEALLOWE��UETOTHEFAIWRETOBEGOMEFAMILIAR WITHTHEENTIREGONSTRUGTION b�EmpB@IB2Ch-NSSEIImBCh.COm DOCUMENTPACKAGE. 5. FIRESPRINKLERSVSTEMANDFIREALARMSVSTEMAREDESIGNBUILDBVTHECONTRACTOR. CONTRACTORSHALLSUBMITFIRESPRINKLER&FIREALARMDRAWINGSTOTHEJURISDICTION(ANDLANDLORDASRE�UIRED)ANDOBTAIN BRIGHTSHEETMETAL HPPROVHL PRIOR TO BEGINNING HNV WORK ON THE FI RE SPRINKLER OR HLHRM SVSTEM. THE FIRE SPRINKLER HND HLHRM WORK SHHLL BE PERFORMED UNDER H SEPHRHTE PERMIT WHERE HPPLICHBLE. CONTACT: BILL COU RTER fl RREEXTINGUISHERSSHnLLBEINSTnLLEOINnCCORonNCEWITHNFPn]2813nNOTHELOCnLJURISOICTIONRE�UIREMENT5.U5E5EMIRECE55EOWnLLMOUNTEOCnBWETS,U.o.N. TEL:317223.3285 z ALLFLOORINGALONGAMFANSOFEGRESSPAiHOFiRAVELSHALLBESLIPRE515iANiINAGGOROANGEwIiHLOGALGOOEREpUIREMENiS. bcourter@brighLsheetmetaLcom e. CONTRACTORSHALLINSPECTALLE%ISTINGFIREPROOFINGOFSTRUCTURALELEMENTS,DEMISINGWALLS,ANDFLOORCEILINGASSEMBLIESWHICHARERE�UIREDTOBEFIREPROTECTEDBVGWERNINGCODES.CONTRACTOR ENVIRO-MAX SHHLLPHTCHHNDREPHIFHLLDHMHGEDFIFEPFOOFINGHNDSHHLLREPLHCEHLLMISSINGFIREPROOFING.CONTRHCTORSHHLLMHINTHINTHEE%ISTINGFIRERHTINGSOFHLLELEMENTSHNDSHHLLPHTCHHNDREPHIRHNVDHMHGED CONTACT:GARYGRIDER OR REM W ED ELEMENTS nS RE�UIRED TO MnINTnI N nLL FIRE RnTINGS. TEL: 317281 ]870 9. GONraaGroaSNa��eEaE5aoN5ie�EFoaaaa�nNGFoaallooeraimNGa��raaoEaEamirSalloorNEaaEamir5a5maveEaEOUiaEoevrHE�UaiSoiGnoNSNaviNGaUrNoairvovEarHEaaoJEGr,iNGwoiNGeUrNorumirEo Gary.Grider@enviro-ma�e.net TO SPRINKLER REVIEW FROM THE BUREAU OF FlRE PREVENTION. ID. CONTRACTORSHALLBERESPONSIBLEFORSUBMITTINGANVREVISIONSTOTHEAPPROVEDPERMITDOCUMENTSANDPROCESSINGTHEAPPROVALOFTHEREVISEDDOCUMENTSWITHTHEJURISDICTIONSHAVINGAUTHORITV. •ELECTRICAL:MUSTMCLUDETHISVENDORINTHEBIDPROCE55 11. CONTRHCTORSHHLLPHTCHHNDREPHIRHLLE%ISTINGSUBSTRHTESTORECENENEWSCHE�ULE�FINISHES.GENERHLCONTRHCTORTOENSUREHLLSURFHCESHREPREPHRE�HSNECESSHRVFORHCOMPLETEHNDPROPER INSTALLATION OF SAIo FlNISHES. BARTH ELECTRIC iz. aaovioEa�oCKin�GnSaEaUiaEOFoan��wn��MOUn�rEortEMSin�Cwoin�GMi��woaKCnein�ErSnn�oCOUn�rEa5,5NE�vES,ErC.n��w000a�oCKin�GroeEOFFwEaErnaonn�rraEnrEOCon�sraUCrioN. CONTACT:MICHELEGENTFV TEL: 317.921.5121 t3. ALLWALLANDCEILINGFINISHESTOHAVEMINIMUMCLASS"C"FLAMESPREADRATING.(]fiT0200)PERSECTIONB mg0ntry@b2rth010Ctri0.CAm 14. NEWFLOORFINISHESSHHLLMEETCLHSS"II"CRITICHLRHDIHNTFW%OF022ORHIGHER.PERSECTIONe 15. ALLNEW o00R HAROWARE TO MEEf AGGESSIBIUTV RE�UIREMENTS. • FIRE ALARM: MUST INCLUDETHIS VENDOR IN THE BID PROCESS 16. PRIORTOCONSTRUCTIONTHEGENERALCONTRACTORISRESPONSIBLETOOBTAINCOPVOFCONSTRUCTIONRULES&REGULATIONSALONGwITHANVOTHERWFORMATIONORRESTRICTIONSFROMTHELANDLORDANDFOLLOwALL KOORSENFIREPROTECTION SETPROCEDURES. TEL:31Z252.0654 I) CLOSE OUT MHNUHLS IN CD FOFMHT HND (1) HHFD COPV IN BINDER WITH THE FOLLOWING DOCUMENTS�. HLL GUHRHNTEES, HLL WHFFHNTIES, OPEFHTING MHNUHLS, GC CONTHCT INFOFMHTION. RELEASED FOR CONSTRl1CTI0N �Ar�oN �ERr�F��ArE oF o���PAN�� ��EN wA��ERs s��NEo oFF P�N�� ��sr ANo A�R rEsr ANo aA�AN�E REPORr >IBLETOIMMEoIATELVOPENALLAPPLIANGESwHENDELIVEREDANOGHEGKFORDAMAGEDAMAGESARETOBENOTEDONBILLOFLADINGATTIMEOFDELIVERV.NOTIFVGBREPROJEGTMANAGER �FIRESPRINKLER:MUSTMCLUDETHISVENDORINTHEBIDPROCE55 Su6jec��ocompliancewithallregula�ions DISCREPANCIES. KOORSENFIREPROTECTION ofSla�eantlLocalCodes !THATALLSUB-CONTRACTORSRECEIVEACOMPLETESETOFCONSTRUCTIONDRAWINGSTOENSUREFULWNDERSTANDINGANDCOMPLIANCEWITHCONSTRUCTIONDOCUMENTS. TEL:317252.0654 CityofCarmel qryS.wHENPROVIOEo.HREFORCONiRHCiOR'SGENERHLWFORMHiION/COOROINHiIONPURPOSEOONLVHNOHREPROVIOEOONLVFORREFERENCEPLEHSENOiEiHHiwMLEiHE �p,y GOOR�INATE�WITHTHEWFORMATION WITHINTHESEPlANS,THESEVEN�ORPROVI�E��OGUMENTS�ONOTFALLUN�ERTHEARGHITEGT'S/�ESIGNGONSULTANT'SUMBRELLAOF y��«������%`V'�ti�a�l. ;OOR�INATEWITHTENANT'SVEN�ORTOENSURETHATTHEVHAVETHEMOSTGURRENTPLANSPRIORTOGOOR�INATINGANVWORKTOBEGOMPLETE�. 1 onrE: 12/09/19 PROJECT DIRECTORY •PROJECT MANAGER CBRE,INC. GLOBAL WORKPLACESERVICES CONTACT: PYLLIS PARMA PROJECT MANAGER CEL 469-84Z8�25 pparma@Iravelers.com • CORPORATE REAL ESTATE TRAVELERS I CORPORATE RFAL ESTATE 1301 E. COLLINS BLVD. RICHARDSON, TX 75081 CONTACT:KATHVSEPMOREE TEL: 214.570.6091 CEL 214.�28.4641 ksepmore@Iravelers. co m •LANDLORD STRATEGIC CAPITAL PARTNERS 600 E. 96TH STREET SUITE 150 INDIANAPOLIS, IN 46240 CONTACT: BRAIN DISBOROUGH TEL31Y819-08�6 bd isboro ugh @strategiccapitalpartners.com • SECURITY BOBSTEVENS TRAVELERS TEL: 651.310.8100 dsteven@Iravelers.com • AV/IT JAMES BEHAN TRAVELERS TEL 651.310.4242 jbehan@Iravelers.co m • ARCHITECT: THEidGROUP 2641 IRVING BLVD. DALLAS, T%75207 TEL: 214.63B.6B00 EMAIL cmclain@idgroupdallas.com CONTACT: CARRV D. MCLAIN • SENIOR DESIGN CONSULTANT idGFOUP 2641 IRVING BLVD DALLAS, TX 75207 TEL: 214.638.6800 FAX: 214.639.0.301 CONTACT: KIM CUMMINGS kcu mm ings@ itlg ro uptlallas.com • PM DESIGN CONSULTANT idGROUP 2641 IRVING BLVD DALLAS, TX ]520] TEL: 214.638.6800 FAX: 214.639.0301 CONTACT: HOLLV K. NICHOLS hn ich ols@ idg ro updallas.com • DESIGN CONSULTANT idGROUP 2641 IRVING BLVD DALLAS, TX 75207 TEL: 214.638.6800 FAX: 214.639.0301 CONTACT: MELODV POKLADNIK m poklad nik@idgrou pdallas.com • CRITICAL FACILITIES CBRE, INC. I GLOBAL CORPORATE SERVICES CONTACT:GALEN HART TEL:770-246-6B6B • MEP MUSSEfT NICHOLAS AND ASSOCIATES 502 S. WEST STREET INDIANAPOLIS, IN 46225 317.631.9241 CONTACT:PJVOUNGMAN pyoungman@m-ma.com REVISION LOG ALTERNATES �ESCRIPTION SHEETS ACCEPTi DECLME PRICE AS AN ALTERNATE TO PROVIDE NEW STOREFRONT STYLE DOOR AND FRAME ASSEMBLY W ITH TEXTURED GLASS A1 TO MATCH EXISTING 2ND ROOR TRAINING ROOM DOORS IN A2.04 LIEU OF REMOVING �OORSAN� FRAMESAN� RELOCATING TOTHE NEW 1ST FLOOR TRAINING ROOM. DEFERRED SUBMITTALS FIRE ALARM SVSTEM: DEFERRED SUBMITTAL. G.C. SHALL BE RESPONSIBLE FOR PREPARING DRAWINGS AND OBTAINING ALL BUILDING PERMITS AS REQUIRED BY LOCAL JURISDICTION. FlRE SPRINKLER SVSTEM: DEFERRED SUBMITTAL G.G SHALL BE RESPONSIBLE FOR PREPARING DFAWINGS AND OBTAINING ALL BUILDING PEFMITS AS FEQUIFED BY LOCAL JUFISDICTION. SHEET INDEX GOA COVERSHEET&INDEX G0.1 GENERALNOTES G0.3 SPECIFICATIONS GOA SPECIFICATIONS G0.9-1 LIFE 8 SAFETV PLAN- 1 ST ROOR G0.9-2 LIFE&SAFETVPLAN-2N�FLOOR G0.93 LIFE&$AFETVPLAN-3R�FLOOR D1.04 DEMOLITION PLAN- 1 ST ROOR �1.0-2 DEMOLITION PLAN-2ND FLOOR D1.03 DEMOLITION PLAN-3RD FLOOR A2.0-1 CONSTRUCTION PLAN- 1 ST ROOR A2.0-2 CONSTRUCTION PLAN-2ND FLOOR A2.03 CONSTRUCTION PLAN-3RD FLOOR A22-1 POWERSCOMMUNICATIONSPLAN-1STROOR A222 POWER&COMMUNICATIONSPLAN-2N�FLOOR A223 POWER&COMMUNICATIONSPLAN-3RDFLOOR A2 3-1 REFLECTED CEILING PLAN- 1 ST FLOOR A2 3-2 REFLECTE� CEILING PLAN- 2N� FLOOR A2.33 REFLECTED CEILING PLAN- 3RD FLOOR A25-1 FINISH PLAN- 1 ST FLOOR A25-2 FINISH PLAN-2N� FLOOR A2S3 FlNISH PLAN-3RD ROOR A3.0-1 FURNITURE PLAN- 1ST ROOR A3.0-2 FURNITURE PLAN-2N� FLOOR A3.03 FURNITURE PLAN-3RD FLOOR A6.0 INTERIOR ELEVATIONS A].0 �OOR SCHE�ULE, SECTIONS, & �ETAILS AB.O SECTIONS & DETAILS MECHANICAL M00-0 MECHANICALABBREVIATIONSAN�SVMBOLS M0.0-1 MECHANICALSPECIFICATIONS M00-2 MECHANICALSPEqFICATIONS M003 MECHANICALSPECIFICATIONS MD1.0-1 MECHANICAL �EMOLITION PLAN - 1 ST FLOOR MD1.0-2 MECHANICALDEMOLITIONPLAN-2NDROOR M�1.0-3 MECHANICAL�EMOLITIONPLAN-3R�FLOOR M1 0-1 MECHANICAL PLAN - 1 ST FLOOR M10-2 MECHANICALPLAN-2NDROOR M103 MECHANICALPLAN-3RDFLOOR ELECTRICAL E0.0-0 ELECTRICALABBREVIATIONSANDSVMBOLS E0.04 ELECTRICALABBREVIATIONSANDSVMBOLS E0.0-2 ELECTRICALSPECIFICATIONS ED104 LIGHTINGDEMOLITIONPLANS-1STFLOOR E�1 0-2 LIGHTING �EMOLITION PLANS-2N� FLOOR ED103 LIGHTWG�EMOLITIONPLAN$-3R�FLOOR E1.04 LIGHTING ROOR PLAN - 1 ST ROOR E1.0-2 LIGHTING FLOOR PLAN -2N� FLOOR E1.03 LIGHTING FLOOR PLAN -3RD FLOOR ED2 04 POWER AND COMMUNICATIONS DEMOLITION PLAN - 1 ST ROOR E�20-2 POWERANDCOMMUNICATIONSDEMOLITIONPLAN-2NDFLOOR ED2.03 POWERANDCOMMUNICATIONSDEMOLITIONPLAN-3RDFLOOR E2.04 POWERANDCOMMUNICATIONSPLAN-1STROOR E20-2 POWERANDCOMMUNICATIONSPLAN-2NDFLOOR E2.03 POWERAN�COMMUNICATIONSPLAN-3R�FLOOR ED30-1 PANELSCHEDULESDEMOLITION-1STFLOOR E�30-2 PANELSCHEDULESDEMOLITION-2NDFLOOR ED303 PANELSCHE�ULES�EMOLITION-3R�FLOOR E3.04 PANELSCHEDULES-1STROOR E3.0-2 PANELSCHEDULES-2NDFLOOR E3.03 PANELSCHEDULES-3RDFLOOR PLUMBING P�1.0-2 PWMBINGDEMOLITIONPLAN-2NDFLOOR PD1.03 PLUMBING DEMOLITION PLAN-3RD FLOOR P1.0-2 PLUMBINGPLAN-2NDROOR P1.0-3 PLUMBINGPLAN-3RDFLOOR FIRE PROTECTION FP1.04 FIRE PROTECTION PLAN - 1 ST FLOOR FP1.0-2 FIRE PROTECTION PLAN - 2ND FLOOR FP1.03 FIRE PROTECTION PLAN - 3R� FLOOR PFOJELT COOFDINATOFi DESIGN CONSULTAN7 / 1 / id 2fi41 IRVING BLVD. DALLA$ TEXAS �520� TEL: 214-638-6800 AFCHITECT�ENGINEEF ' PP� - D ..M�'<'`••. :�Q.,P���srpqFQ 9�: � I�No.AR11800W1�! � PRo�E�r�o DRAWN BY'. CHECKEDBY: TRAVELERB PROJECTY: � � n�1 �� � � � � � � INDIANAPOLIS ,0,4,9 �=030 MPNF HNMC/CM P10 0312 SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1ST, 2ND, & 3RD FLOOR INDIANAPOLIS, IN 46240 NO. REVISIONS'. DATP. LAN�LOR� REVIEW ISSUE �ATE 10.14.19 TENANT REVIEW ISSUE DATE: 1000.19 eioissueonTe�. �o.�a.is PERMITISSUE�ATE 10.14.19 CONSTRUCTIONISSUEDATE: %%i%%i2019 oanwirvc nT�E: COVER SHEET & INDEX DRAWING NUMBER. G0.0 �O 2019 idGROUP, LLC