Loading...
HomeMy WebLinkAboutM0.0-0 Mechanical Abbreviations & SymbolsMECHANICAL & PLUMBING SYMBOLS �I 6ALL VALVE I��1I BUTTERFLY VALVE I�VI BUTTERFLY VALVE 'MTH MANUAL GEAR OPERATOR p� GAiE VALVE 'MiH NON RISING SiEM � GAiE VALVE WIiH OS&Y OR RISING STEM qQ GLOBE VALVE � ANGLE GLOBE VALVE T� ANGLE GATE VALVE I�I cocK (saunRE HEno) ��]I COCK (HAN�LE) � PWG VALVE � 2—WAY VALVE WITH ELECTRONIC (MODULATING) OPERAIOR p'Q 2—WAY SOLENOID VALVE � 3—WAY VALVE WITH PNEl1MATIC OPERATOR � 3—WAY VALVE WITH 2—POSITION OPERATOR � SUCiION DIFFUSER � iRIPLE DUiY VALVE � IN—LME PUMP f I 6ASE MOUNiED OR CLOSE—COUPLED PUMP \ l � HOR20NTAL SPLIT CASE PUMP �� UNION qPRESSUftE GAUGE 'MiH GAUGE COCK 4 iHERMOMEiER �F �f— iHERMOMETER WELL ONLY pb LOCKSHIEL� VALVE �} BALL VALVE WITH BLEED PORT ] CAP OR PLUG �I 6LIND FLANGE � P/T PORT � MANUAL BALANCE VALVE m AUTOMATIC FLOW WNiROL VALVE �' SiRAINER WIiH BLOWDOWN VALVE, HOSE WNNECiION AND CAP � STRAWER WITH BLOWDOWN VALVE AND HOSE CONNECiION �r 51EAM iRAP (i1PE INDICAiED) � PRESSl1RE SWITCH � FLOW SWITCH jV CHECK VALVE � PIPING ELBOW NRNED DOWN � PIPING ELBOW IDRNED UP � PIPING TEE, 6RANCH OUT BOTTOM � PIPING TEE, 6RANCH OUT TOP � PIPING E%PANSION JOINT � CONCENiRIC REDUCER � EccENtRic REoucER (smnicHt iNVERt) � EccENTRic REoucER (srnnicHT cRovmE) PITCH PIPE (RISE) '�� PITCH PIPE (DROP) � PRESSURE RE�UCING VALVE � RELIEF VALVE � AIR ELIMINATOR � AUTOMATIC AIR VENT -0� PIPING BALL JOINT � FLEXIBLE CONNECTOR {}'{ VENIURI FLOW ME1ER QQ iHERMOSiAi OR iEMPERAIDRE SENSOR �r HUMIDISTAT OR Hl1MI01TY SENSOR � CARBON �IOXIDE SENSOR Q �EWPOINi SENSOR � � aeFRiceanNt MONitoR (seNsiNc HecHr) 0 SELF WNiAINED BREAiHING APPARAIDS �F PIPE ANCHOR — PiPE cuioe � FLOW ARROW �G� MANUAL AIR VENi (1/7' BALL VALVE UNLE55 NOTED OTHERWISE) � MANUAL DRAIN VALVE WITH HOSE CONNECTION AND CAP (3/4" UNLESS NOTE� OTHERWISE) O WAiER MEiER ,_+.. R_r.. REDUCED PRESSURE ZONE BACK FLOW PREVENiER ������"� (WITH STRAINER AND AIR GAP FITiING) Y � WATER HAMMER ARRESTER (SHOCK ABSORBER) �� DOUBLE CHECK ASSEMBLY �DOUBLE CHECK �ETECTOR ASSEM6LY � SPRINKLER HEAD RELEASED FOR CONSTRACTION (oowN� Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes LVE City of Carmel �i `��¢m�' lamn�Mn?>� 1 onrE: 12/09/19 A.EF. ABOVE FlNISHED FLOOR ACC AIR COOLED WNDENSER AHU AIR HANDLING UNIT AP ACCE55 PANEL AS AIR SEPARATOR B BOILER BCU BLOWER COIL UNIT BDD BACK DRAFT DAMPER BHP BRAKE HORSEPOWER BTU BRIiISH THERMAL UNITS BTUH BRIiISH THERMAL UNITS PER HOUR •c oECREEs cE�sius CC WOLING COIL CFM CUBIT FEET PER MINUIE CI CAST IRON c CENiERLINE W 0.EAN OUi CP WNTROL PANEL WH CABMET UNIT HEAiER CW WLD WAiER DB DRY Bl1LB DS DOWN SPOUT DTR DUAL TEMPERAIDRE RETURN Di5 DUAL iEMPERAIDRE SUPPLY EA EACH EAT ENTERING AIR iEMPERATURE ECRG EGG CRAiE RETURN GRILLE EF EXHAUST FAN EG E%HAUST GPoLLE OR ETHYLENE GLYCOL ENCL ENCLOSURE ESP E%iERNAL STA71C PRESSURE Ei EXPANSION iANK EWC ELECTRIC WATER COOLER EWT ENTERING WATER iEMPERATURE EXH EXHAUST AIR EX EXIS7ING EXIST E%ISTING F & BP FACE & B1PA55 F& 1 FLOA1 & 1HERM051AiIC (S1EAM 1RAP) F �EGREES FAHRENHEIT FA FACE AREA FCU FAN COIL UNIT FCV FLOW CONiROL VALVE FD FLOOR �RAIN F DMPR FIRE DAMPER FE FIRE EXiINGUISHER FEC FIRE EXiINGUISHER CABMET FHC FIRE HOSE CABMET FLA FULL LOAD AMPS FPHB FREEZE PROOF HOSE BIBB FPF FWS PER FOOT FPI FINS PER INCH FPM FEEi PER MINUiE FPVAV FAN POWERED VARIABLE AIR VOLUME BOX FS FUSED SWIiCH FT FOOT FT. HD. FOOT OF WAIER HEA� FTR FIN TUBE RA�IATION FV FACE VELOCITY G GAS GI GALVANIZED IRON GPH GALLONS PER HOUR GPM GALLONS PER MINUiE HB HOSE BIBB HOA HAND-0FF—AUTOMAiIC HP HORSEPOWER H'STAT Hl1MIDISTAT HTG HEATING HW HOi WAiER HWA HOi WAiER REIURN HHWR HEATING HOT WATER RETURN HHWS HEATING HOT WATER SUPPLY IB INVERTE� BUCKET (STEAM 7RAP) IN INCH IN. W.C. INCHES OF WATER COWMN IN. W.G. INCHES OF WATER GAUGE KW NILOWAiiS KWH NILOWATT HOURS LAV OR L LAVATORY LAT LEAVING AIR iEMPERANRE LBS/HR POUNDS (MASS) PER HOUR LD LINEAR DIFFUSER LWT LEAVING WATER TEMPERAIDRE MAG MAGNEiIC MAN MANUAL MB MOP BASIN MBH 1000 BNH MCC MOTOR CONiROL CENTER AIFR. MANUFACTURER MH MANHOLE MS MOP SUMP OR MOP SINK MSD MUL11—VANE SPL111ER DAMPER MSP MOTOR STARTER PANEL NC NORMALLY CLOSE� NF NON—FUSED N0. Nl1M6ER NO NORMALLY OPEN OA WiSIDE AIR OB OUiLEi BOX OBD OPPOSE� BLADE DAMPER OSD OPEN SIGHT �RAIN OV OUTLET VELOCITY P POLE PB PUSH-6UTTON PBD PARALLEL BLADE DAMPER PCC PREWNDIiIONING COIL ABBREVIATIONS P.D. PRESSURE DROP PG PROPYLENE GLYCOL PHC PREHEAT COIL PL PILOT LIGHT PM PLEATED MEDIA (FlLTERS) PRV POWER ROOF VENTILATOR OR PRESSURE RE�UCING VALVE PSI POUNDS PER SOUARE INCH PSIG POUNDS PER SpUARE INCH GAUGE PUH PROPELLER UNIi HEAiER QiY QUANiIiY RA RETURN AIR RD ROOF �RAIN REC RECESSED RG RETURN GRILLE RH RANGE HOOD RHC REHEAT COIL RN RWF INiANE VENi RPM REVOWiIONS PER MINUiE RRV ROOF RELIEF VENT SA SUPPLY AIR SAN SANITARY SC SILL COCK SCD Spl1ARE CBLING DIFFUSER SD SPLIiiER DAMPER SG SUPPLY GRILLE SH SHOWER SHD SHOWER �RAIN SK SINK SP STAiIC PRESSl1RE SS SOIL STACK SSK SERVICE SINK suRF suRFacE SW SWITCH TA iHROW AWAY (FlLTERS) TB TERMINAL BOX TD TRENCH DRAIN TDH TOTAL DYNAMIC HEA� iMV TEMPERAIDRE MI%ING VALVE iRD 1ROFFER DIFFUSER T'STAT iHERMOSTAT TSP TOTAL STATIC PRESSURE TW iEMPERE� WATER TYP. TYPICAL UH UNIT HEATER UR URINAL VA VENiILAiION AIR (WNDIiIONE� OA) VAV VARIABLE AIR VOWME VD VOWME �AMPER VFD VARIABLE FRE�UENCY DRNE VS VENT STACK VTR VENT THROUGH ROOF VB VACl1l1M 6REAKER W WB WC WH WT. WTD WTR YD 6 0 WASiE WEi BULB WATER CLOSET WALL HY[7RANT WEIGHT WATER TEMPERANRE DROP WATER TEMPERAiURE RISE YARD DRAIN FLA1 OVAL DIAMETER PIPING LEGEND: rva iwa DiS SAN -----SAN----- St _----sr----- fM r c{zasic) uac — RW __________A�__________ VR e� iOWER WAiER SUPPLY TOWER WATER RETURN CMLLED WATER SUPPLY CHILLED WATER RETURN HEATING HOT WATER SUPPLY HEntiNc Hor wntER REtuRN DUAL—TEMPERANRE SUPPLY DUAL—TEMPERANRE RETURN COOLING COIL CONDENSATE DRAIN DOMESTIC COLD WAiER SOFIENED WA1ER DOMESTIC HOT WATER DOMESTIC HOT WAiER RENRN TEMPERED WATER SANITARY WASiE (SUSPENDED) SANIiARY WASiE (BURIED) SANITARY VENT STORM DRAIN (SUSPENDED) STORM DRAIN (BURIED) fORCED MAIN ($ANITARYJ FlRE PROiECiION/SPRINNLER LWE NATURAL GAS (LME PRESSURE) COMPRESSED AIR LOW PRESSl1RE STEAM LOW PRESSURE CONDENSAIE MED PRESSURE SiEAM MED PRESSURE CONDENSATE HIGH PRESSURE STEAM HIGH PRESSl1RE CONDENSATE PUMPED WNDENSAiE ACID WASTE ACID WASTE (BURIED) ACID VENT NON—POTABLE WATER DEIONRED WA1ER REVERSE OSMO515 WAiER VAWUM LWE REFRIGERANT LIQUID REFRIGERANT Sl1CTI0N IiEM i0 6E REMOVED (OEMO) EXISTING TO REMAIN NEW SHEET METAL DUCT STANDARDS MIN. 5 MIiERED SECilONS f ��.� ROUND (OR FLAT OVAL) DUCT ELBOWS: R=LS� USE RADIUS ELBOW (� RADWS = 1.5 � p � DUCT �IAMETER.) h��l � � � RECTANGLE DUCT ELBOWS: 115E MIiERED ELBOW WI1H IDRNING VANES � W � R=1.5W OR USE RADWS ELBOW (� RADWS = If�l 1.5 DUCT WIDTH.) RECTANGULAR DUCT TANEOFF FROM ���� RECTANGULAR DUCT: USE 45 SHOE FITiING. � ROl1ND DUCT TAKEOFF FROM RECiANGULAR DUCi: USE BELL—MOUiH FITTING. (SPIN—IN FITTINGS NOT ; PERMITTED.) > 30' OFFSETS JO' AN� GREATER, USE RADIUS EL60W5. < 30' -. OFFSETS LESS THAN 30', 11SE MITERE� FirnNcs. �12— DUCT ACCESS DOOR (SRE INDICATE�). 121 �Ap ... DOOR SWINGS INTO POSITNE PRESSURE �� - DUCT. �OOR SWINGS OUT FROM NEGATIVE PRESSURE DUCT. AIR HANDLING UNIT SYMBOLS � CENiRIFUGAL FAN � PWG FAN � ELECiRIC HEATING COIL � HYDRONIC OR STEAM COIL � HUMI�IFlER � MIXING BOX HEAi iRANSFER WHEEL DX COIL FlXED PLATE HEAT E%CHANGER ANGLED FlLTERS F- ''SF r=; enc Fat�Rs (oR caRtRiocE Fi�tERs) �� AIR BLENDER 1 ACCESS DOOR � � E%TERNAL F & BP 0 INTERNAL F & BP �\ \ DIVIDE� FLOW iEE USE SPLITiER .... _. DAMPER RauNo ouct (oR F�nt ovn�) TAKEOFF FROM ROUND (OR FLAT OVAL) DUCT: USE CONICAL FliiING OR 45' MIiERED TAKEOFF WITH RADIUS ELBOW. CONTROLS AND INSTRUMENTATION DESIGNATION DEVICE iYPE MARK N0. # # LEADER INDICAiION LOCAiION OF DENCE LIST OF CONTROL AND MSTRUMENTATION DEVICE TMES: CSR CURRENT SENSING RELAY �� ��N�O� �A�� DPS DIFFERENTIAL PRESSl1RE SWITCH DPT DIFFERENTIAL PRESSURE iRANSMITTER FM FLOW MEiER FS FLOW SWITCH PS PRESSURE SWITCH i5 iEMPERAiURE SENSOR GENERAL MECHANICAL NOTES '^_�, ` 1 DEiAIL N0. �SHEEi N0. XXX ELEVAiION LEiiER x XXX SHEET N0. SECTION NUMBER X xxX SHEEi N0. � CONNECiION i0 EXISiING � LIMITS OF DEMOLITION ROOM 1 XXH ROOM IDENTIFlER KEv�o No� oEsicNnnoNs O% NEW WORK �% DEMOLITION �% SPECIALTY REVISION SYMBOL � SHEET METAL SYMBOLS � AIR FLOW MEASURING STAiION � VERiICAL FlRE DAMPER I M010RIZED DAMPER I(MODl1LATING) �MOTORIZED DAMPER (TWO—POSIiION) I GRAVITY BACNDRAPT DAMPER �BAROMEIRIC RELIEF DAMPER �CEILING OR FLOOR MOUNiED FIRE DAMPER � COMBINAiION �FIRE/SMONE DAMPER �'�. SMOKE �AMPER C �I ..,� VOWME DAMPER F FLEXIBLE CONNECiION %iOJECT COOflDINATOfl/DESIGN CONSOLTANT ' � id;�RGJP 2641 IRVING BLVD. DALLAS,TEXAS 75207 TEL 214-638-6800 AflCHRECi/ENGMEEfl 1 1 ' � MUSSETT NICHOLAS + A S S O C I A I t S Engineers +Architecis 502 S. W ESi SiREEi INDIANAPOLIS INDIANA 46225 3 V.631 9241 5974 SIX FORKS ROAD, SUIiE B RALEIGH, NORTH CAROLINA D609 919 ]03 4028 sEn� Na. 10505672 sure or ���iii � PROJECT NO_ DRAWN BY cHEcrcEoer. TRAVELER'S PROJECT IX�. r: ">I. � � � J � � a � � 2019222 DDfl JMF P10-0312 INDIANAPOLIS SEVEN PARKWOOD CROSSING 280 E. 96TH STREET 1ST, 2ND, & 3RD FLOOR INDIANAPOLIS, IN 46240 oanwwcnnE�. MECHANICAL ABBREVIATIONS & SYMBOLS �RAWINGNUMBER'. M0.0-0 �02019 idGROUP, LLC LANDLORD REVIEWISSUE DATP. 10.10.19 TErvnrvTaE�nEwissuEonTE�. io.oe.is BID ISSUE DATE�. 101a 19 PERMITISSUE DATE'. 10.10.19 CONSTRUCTIONISSUE�ATE�. %%�%%�2�19