Loading...
HomeMy WebLinkAboutState CDR - Cottage AnimalELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/2 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on:November 13, 2019 Project number Release date 411598 11/13/19 Construction type Occupancy classification Scope of release V-B B, ADD, REM Type of release Project name Street address City County ARCH ELEC FDN MECH STR Standard Cottage Animal Clinic 420 N Rangeline Rd CARMEL HAMILTON To: Owner / Architect / Engineer Cooler Design William H. Cooler AR10000327 9135 N. Meridian Street Suite A1 Indianapolis IN 46260 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: 14B 4G0412AE 4G0603AN 14B0700 14B100811 14B100819 14B1009 14B100915 14B10097 14B101163 14B10275 This project has been reviewed under the 2014 Indiana Building Code. The proposed building, addition, or remodel shall not put the existing building in noncompliance or into further noncompliance in accordance with 675 IAC 12-4-12. This release does not include plumbing work. Plans and specifications for adding or remodeling this system shall be filed as a new project or as a partial before commencing work in accordance with 675 IAC 12-6-3. Fire resistive construction shall be maintained in accordance with Chapter 7, IBC (675 IAC 13-2.6). Doors serving the means of egress shall be sufficient for the occupant load thereof and shall provide a minimum clear width of not less than 32 inches with a height of not less than 80 inches in accordance with Section 1008.1.1, IBC (675 IAC 13-2.6). Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort in accordance with Section 1008.1.9, IBC (675 IAC 13-2.6). Every stairway serving occupied portion of a building shall comform to the requirements of Section 1009, IBC (675 IAC 13-2.6). Stairways shall have handrails in accordance with Section 1009.15, IBC (675 IAC 13-2.6). Stairway steps shall have rise and run dimensions in accordance with Section 1009.7, IBC (675 IAC 13-2.6). Exit illumination and exit signs shall be connected to a separate emergency power source in accordance with Section 1011.6.3, IBC (675 IAC 13-2.6). The exit discharge shall provide a direct and unobstructed access to a public way in accordance with Section 1027.5, IBC (675 IAC 13-2.6). Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 3175730301, bill@coolerdesign.com ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/2 14B12033 14B12091 14B1600 14B16082 9E11026A 9E21008B 9E41036 AREL Crawl space ventilation shall be provided in accordance with Section 1203.3, IBC (675 IAC 13-2.6). Crawl space access shall be provided in accordance with Section 1209.1, IBC (675 IAC 13-2.6). Buildings, or portions thereof, shall be designed and constructed to sustain all dead, live, and environmental loads in accordance with Chapter 16, IBC (675 IAC 13-2.6). Footings shall have a minimum depth in accordance with Table 1608.2 (Indiana Amendments), IBC (675 IAC 13-2.6). Access and working space shall be provided and maintained about all electric equipment in accordance with Section 110.26, IEC (675 IAC 17-1.8). In other than dwelling units all 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (5) shall have ground-fault circuit-interrupter protection for personnel: (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors and (5) within six (6) feet of the outside edge of sinks in accordance with Section 210.8(B), IEC (675 IAC 17-1.8). Luminaires shall be installed and supported in accordance with Section 410.36. IEC (675 IAC 17- 1.8). Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Code review official Address (name,title of local official,street,city,state and ZIP code EDWARD HENN JIM BLANCHARD ONE CIVIC SQUARE CARMEL,IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Indiana State Building Commissioner ehenn@dhs.in.gov