CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on:November 13, 2019
Project number Release date
411598 11/13/19
Construction type Occupancy classification
Scope of release
V-B B, ADD, REM
Type of release
Project name
Street address
City County
ARCH ELEC FDN MECH
STR
Standard
Cottage Animal Clinic
420 N Rangeline Rd
CARMEL HAMILTON
To: Owner / Architect / Engineer
Cooler Design
William H. Cooler AR10000327
9135 N. Meridian Street
Suite A1
Indianapolis IN 46260
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
4G0412AE
4G0603AN
14B0700
14B100811
14B100819
14B1009
14B100915
14B10097
14B101163
14B10275
This project has been reviewed under the 2014 Indiana Building Code.
The proposed building, addition, or remodel shall not put the existing building in noncompliance or
into further noncompliance in accordance with 675 IAC 12-4-12.
This release does not include plumbing work. Plans and specifications for adding or remodeling this
system shall be filed as a new project or as a partial before commencing work in accordance with
675 IAC 12-6-3.
Fire resistive construction shall be maintained in accordance with Chapter 7, IBC (675 IAC 13-2.6).
Doors serving the means of egress shall be sufficient for the occupant load thereof and shall
provide a minimum clear width of not less than 32 inches with a height of not less than 80 inches in
accordance with Section 1008.1.1, IBC (675 IAC 13-2.6).
Exit doors shall be openable from the inside without the use of a key or any special knowledge or
effort in accordance with Section 1008.1.9, IBC (675 IAC 13-2.6).
Every stairway serving occupied portion of a building shall comform to the requirements of Section
1009, IBC (675 IAC 13-2.6).
Stairways shall have handrails in accordance with Section 1009.15, IBC (675 IAC 13-2.6).
Stairway steps shall have rise and run dimensions in accordance with Section 1009.7, IBC (675 IAC
13-2.6).
Exit illumination and exit signs shall be connected to a separate emergency power source in
accordance with Section 1011.6.3, IBC (675 IAC 13-2.6).
The exit discharge shall provide a direct and unobstructed access to a public way in accordance
with Section 1027.5, IBC (675 IAC 13-2.6).
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
3175730301, bill@coolerdesign.com
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
14B12033
14B12091
14B1600
14B16082
9E11026A
9E21008B
9E41036
AREL
Crawl space ventilation shall be provided in accordance with Section 1203.3, IBC (675 IAC 13-2.6).
Crawl space access shall be provided in accordance with Section 1209.1, IBC (675 IAC 13-2.6).
Buildings, or portions thereof, shall be designed and constructed to sustain all dead, live, and
environmental loads in accordance with Chapter 16, IBC (675 IAC 13-2.6).
Footings shall have a minimum depth in accordance with Table 1608.2 (Indiana Amendments), IBC
(675 IAC 13-2.6).
Access and working space shall be provided and maintained about all electric equipment in
accordance with Section 110.26, IEC (675 IAC 17-1.8).
In other than dwelling units all 125-volt, single-phase, 15- and 20-ampere receptacles installed in the
locations specified in (1) through (5) shall have ground-fault circuit-interrupter protection for
personnel: (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors and (5) within six (6) feet of the
outside edge of sinks in accordance with Section 210.8(B), IEC (675 IAC 17-1.8).
Luminaires shall be installed and supported in accordance with Section 410.36. IEC (675 IAC 17-
1.8).
Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from
required compliance with all applicable rules of the commission, even if noncompliant conditions
appear in the plans and specifications that have been filed with the division. The owner is
responsible for correcting any and all areas of noncompliance even if they are discovered
subsequent to the issuing of this design release.
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
EDWARD HENN
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL,IN 46032
DEPT OF COMMUNITY SERVICE
Fax & e-mail: 3175712499, jblanchard@carmel.in.gov
Indiana State Building Commissioner ehenn@dhs.in.gov