HomeMy WebLinkAbout10475 Hussey Lane Drainage TIR 10-18-19Stormwater Technical Information Report
For:
Proposed Single Family Residence
10475 Hussey Lane
Carmel, Indiana 46032
Job #: 19-01-01
Date: 10/18/2019
Prepared for:
Hoss Building Group, Inc.
11825 Broadway Street
Carmel, IN 46236
Steve Hoss – 317.823.9788
Prepared by:
Red Barn Engineering Company
Chris Hinkle, PE
317 -677-6797
Chris@RedBarnEngineeringCo.com
TABLE OF CONTENTS
Section I: Project Description
A. Project Title
B. Project Description
C. Project Parameters
D. Design Method and Criteria
E. Summary of Proposed Flow rates
F. References
Section II: Appendix
A. Soils Map
B. FEMA Map
C. Existing Conditions Exhibit
D. Proposed Conditions Exhibit
E. Runoff Calculations Including:
1. Basin C Factor Calculations
2. Basin Release Rates
3. Water Quality Calculations
10/17/19 Page 1
Section I: Project Description
A. Project Title
New Single Family Residence
B. Project Description
This project is located at 10745 Hussey Lane in Clay Township, Hamilton County, Carmel,
Indiana. The site is approximately 13.2+/- acres with the proposed disturbed area being
approximately 6.0 acres. The site is currently a combination of wooded and meadow areas.
The proposed development of the site will consist of the construction of a single family
residence along with a couple of associated out buildings. There will be a new driveway,
parking areas, pool, and pond constructed along with the main residence. A majority of the
proposed runoff from the disturbed area will be routed through a new drainage system and
to the proposed wet pond located to the south of the main residence.
C. Project Parameters
Zoning
This site is currently zoned I-3 and I-4 (Industrial District). The I-3 and I-4 zoning
designation permits industrial development. The existing land uses and zoning adjacent to
the site are as follows:
North: Residential, S-2
West: Residential, S-1
South: Residential, S-2
East: Residential, S-2
Soil Type
Soil maps from the United States Department of Agriculture, Soil Conservation Service,
identify the site as having Miami soils (MmB2, MoC3, and MoD3) and Shoals silt loam (Sh),
0 to 2 percent slopes. The Miami soils are a part of Hydrologic Soil Group B and the Shoals
soils are a part of Hydrologic Soil Group C.
Watershed
The site is located within the White River watershed and within the Williams Creek
watershed. The 14-digit Hydrologic Unit Code is 05120201090060. The site is located in
Zone X and Zone AE per Flood Map Panel 041 of the Flood Insurance Rate Map for
Hamilton County, (FIRM Number 18097C0041 F), dated April 19, 2016.
D. Design Methods and Criteria
The stormwater management calculations have been performed based on the criteria
available from the City of Carmel Stormwater Technical Standards Manual. The intent of the
stormwater design is to restrict the proposed runoff rates to ensure they are in accordance
with the City of Carmel Technical Standards Manual. All calculations referred to in this
report can be found in the Appendix of this report.
The Rational Method has been used to generate runoff from the developed watershed and
for the proposed stormwater detention calculations. Factors involved in the use of this
method are the area of the watershed, the runoff coefficient, the time of concentration, and
10/17/19 Page 2
the associated rainfall intensity for the selected rainfall event. The runoff coefficient is
estimated based on the proposed land use.
Pre-Developed Conditions:
Existing storm water runoff from the project area generally sheet drains from the northwest
to southeast corner of the property. Williams Creek runs just to the east of the property and
the majority of the site drains directly to Williams Creek.
Post-Developed Conditions:
The proposed development of the site will consist of the construction of a single family resi-
dence on the site. A new wet pond will be constructed to the south of the residence. The
runoff form the proposed improvements will be collected in foundation drains, roof drains,
and swales and routed to the proposed wet pond.
The goal of the proposed management plan is to reduce the overall runoff from the site in
accordance with the guidelines set forth in the City of Carmel Stormwater Technical Stand-
ards Manual. The proposed watershed for the development encompasses 4.70 acres. The
proposed 10-year runoff will be detained to the 0.1 cfs/acre (0.47 cfs) rate and the proposed
100-year runoff will be detained to the 0.3 cfs/acre (1.41 cfs) rate.
Runoff from the proposed site will be collected in the stormwater collection systems
throughout the site and routed to the proposed wet pond. The proposed release rate from
the pond will be controlled with a 6” diameter pipe. The detention calculation requires a 4”
diameter pipe, but as noted in the City of Carmel Stormwater Technical Standards Manual,
the minimum size of the outlet pipe is 6”. Runoff from the pond will be discharged onto the
ground just to the southeast of the pond where it will eventually make its way to the south-
east and into Williams Creek.
A 2.5” diameter outlet pipe will provide water quality for the proposed wet pond. This pipe
will be set at the normal pool elevation (801.0) and will outlet to the southeast to the same
location as the main pond outlet. In addition to the two main pond outlet pipes, a 25’ wide
spillway will be constructed to allow the pond to overtop and release 1.25 x the proposed
100-year flow from the project site.
E. Summary of Proposed Flowrates:
Post-Developed Runoff (with 4” outlet pipe design): 100yr. = 0.33 cfs
The proposed wet pond has been designed in accordance with the City of Carmel Storm-
water Technical Standards Manual for both water quantity and water quality. Therefore,
there is no negative impact expected from this proposed project.
F. References
1. Herpicc Stormwater Drainage Manual – Revised July 1995.
2. Hamilton County Soil Survey – National Resources Conservation Service.
3. City of Carmel Storm water Design and Construction Manual (Updated 2017).
4. National Flood Insurance Program - Federal Emergency Management Agency.
10/17/19 Page 3
SECTION II:
APPENDIX
10/17/19 Page 4
Soil Map—Hamilton County, Indiana
(10475 Hussey Lane)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
9/19/2019
Page 1 of 344206704420710442075044207904420830442087044209104420950442099044210304420670442071044207504420790442083044208704420910442095044209904421030570890570930570970571010571050571090571130571170
570890 570930 570970 571010 571050 571090 571130 571170
39° 56' 11'' N 86° 10' 13'' W39° 56' 11'' N86° 10' 1'' W39° 55' 59'' N
86° 10' 13'' W39° 55' 59'' N
86° 10' 1'' WN
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 16N WGS84
0 50 100 200 300
Feet
0 25 50 100 150
Meters
Map Scale: 1:1,880 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
10/17/19 Page 5
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Map Unit Polygons
Soil Map Unit Lines
Soil Map Unit Points
Special Point Features
Blowout
Borrow Pit
Clay Spot
Closed Depression
Gravel Pit
Gravelly Spot
Landfill
Lava Flow
Marsh or swamp
Mine or Quarry
Miscellaneous Water
Perennial Water
Rock Outcrop
Saline Spot
Sandy Spot
Severely Eroded Spot
Sinkhole
Slide or Slip
Sodic Spot
Spoil Area
Stony Spot
Very Stony Spot
Wet Spot
Other
Special Line Features
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:15,800.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Hamilton County, Indiana
Survey Area Data: Version 19, Sep 7, 2018
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Aug 1, 2018—Sep
30, 2018
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Soil Map—Hamilton County, Indiana
(10475 Hussey Lane)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
9/19/2019
Page 2 of 310/17/19Page 6
Map Unit Legend
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
MmB2 Miami silt loam, 2 to 6 percent
slopes, eroded
2.2 17.0%
MoC3 Miami clay loam, 6 to 12
percent slopes, severely
eroded
0.5 3.9%
MoD3 Miami clay loam, 12 to 18
percent slopes, severely
eroded
2.6 20.8%
Sh Shoals silt loam, 0 to 2 percent
slopes, frequently flooded,
brief duration
7.4 58.2%
Totals for Area of Interest 12.7 100.0%
Soil Map—Hamilton County, Indiana 10475 Hussey Lane
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
9/19/2019
Page 3 of 3
10/17/19 Page 7
USGS The National Map: Orthoimagery. Data refreshed April, 2019.
National Flood Hazard Layer FIRMette
0 500 1,000 1,500 2,000250Feet
Ü86°10'30.21"W 39°56'21.51"N 86°9'52.75"W 39°55'53.93"N
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOODHAZARD AREAS
Without Base Flood Elevation (BFE)Zone A, V, A99With BFE or Depth Zone AE, AO, AH, VE, AR
Regulatory Floodway
0.2% Annual Chance Flood Hazard, Areasof 1% annual chance flood with averagedepth less than one foot or with drainageareas of less than one square mile Zone X
Future Conditions 1% AnnualChance Flood Hazard Zone XArea with Reduced Flood Risk due toLevee. See Notes.Zone X
Area with Flood Risk due to Levee Zone D
NO SCREEN Area of Minimal Flood Hazard Zone X
Area of Undetermined Flood Hazard Zone D
Channel, Culvert, or Storm SewerLevee, Dike, or Floodwall
Cross Sections with 1% Annual Chance17.5 Water Surface ElevationCoastal Transect
Coastal Transect BaselineProfile BaselineHydrographic Feature
Base Flood Elevation Line (BFE)
Effective LOMRs
Limit of StudyJurisdiction Boundary
Digital Data Available
No Digital Data Available
Unmapped
This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The basemap shown complies with FEMA's basemap accuracy standards
The flood hazard information is derived directly from theauthoritative NFHL web services provided by FEMA. This mapwas exported on 9/20/2019 at 4:11:52 PM and does notreflect changes or amendments subsequent to this date andtime. The NFHL and effective information may change orbecome superseded by new data over time.
This map image is void if the one or more of the following mapelements do not appear: basemap imagery, flood zone labels,legend, scale bar, map creation date, community identifiers,FIRM panel number, and FIRM effective date. Map images forunmapped and unmodernized areas cannot be used forregulatory purposes.
Legend
OTHER AREAS OFFLOOD HAZARD
OTHER AREAS
GENERALSTRUCTURES
OTHERFEATURES
MAP PANELS
8
1:6,000
B 20.2
The pin displayed on the map is an approximate point selected by the user and does not represent an authoritative property location.10/17/19Page 8
EXISTING
BASIN
204,550 SF
EXISTING DRAINAGE BASINS
10475 HUSSEY LANE
CARMEL, IN 46032
Red Barn Engineering Company, LLC
Civil Engineering Consulting Services
317.677.6797
Chris@RedBarnEngineeringCo.com
SCALE: 1"=120'
09/20/19
10/17/19 Page 9
WELL FOR POND PROPOSED NATIVE STREAM BUFFER PRESERVATION EASEMENTSIGNAGE TO BE BE PLACEDALONG BORDER OF EASEMENTENTIRE EASEMENT TO BE BE PLANTED IN NATIVE SEEDINGPROPOSED NATIVE STREAM BUFFER PRESERVATION EASEMENTSIGNAGE TO BE BE PLACEDENTIRE EASEMENT TO BE BE PLANTED IN NATIVE SEEDINGALONG BORDER OF EASEMENT802
803
804
803
802
804
805
804
803
802 805806
801
800
806
SIGN799
793
795
790
787
PROPOSED IRR
E
G
U
L
A
R
DRAINAGE EAS
E
M
E
N
T
20 LF OF 6" SCH40
PVC STORM SEWER
@ 2.00% SLOPE
INV.=801.20
INV.=800.80
INV.=801.00
20 LF OF 2.5" SCH40
PVC STORM SEWER
@ 1.00% SLOPE
PR
O
P
O
S
E
D
I
R
R
E
G
U
L
A
R
DR
A
I
N
A
G
E
E
A
S
E
M
E
N
T
PROPOSED
RESIDENCE
FFE=808.4±
PROPOSED
BARN
FFE=804.3±
PROPOSED
GARAGE
FFE=806.2±
PROPOSED
GARAGE
FFE=806.2±
PROPOSED
BASIN
204,550 SF
PROPOSED DRAINAGE BASINS
10475 HUSSEY LANE
CARMEL, IN 46032
Red Barn Engineering Company, LLC
Civil Engineering Consulting Services
317.677.6797
Chris@RedBarnEngineeringCo.com
SCALE: 1"=120'
09/20/19
10/17/19 Page 10
WATERSHED TOTAL TOTAL Roof (sf)Pond (sf)Pavement (sf)Lawn (sf)Light Woods Bare Earth Woods (sf)
AREA (ac)AREA (sf)WEIGHTED
Runoff Coefficient 0.90 0.90 0.85 0.20 0.25 0.55 0.20 RUNOFF C
Existing Basin 4.70 204550 0 0 0 102275 102275 0 0 0.23
Proposed Basin 4.70 204550 24637 45220 28370 75098 31225 0 0 0.54
DEVELOPED SITE DRAINAGE BASIN C FACTOR CALCULATIONS
10/17/19 Page 11
0.54
4.70 4.70
0.47 1.41
Total Tc(A) Area(C) Runoff Coef.(I) Intensity(Q) Runoff CFSOutlet CFSStorage RateVolume acre-ftTotal Tc(A) Area(C) Runoff Coef.(I) Intensity(Q) Runoff CFSOutlet CFSStorage RateVolume acre-ft0.08 4.70 0.54 6.12 15.533 0.47 15.06 0.100 0.08 4.70 0.54 9.12 23.1 1.41 21.737 0.145
0.17 4.70 0.54 5.22 13.248 0.47 12.78 0.181 0.17 4.70 0.54 7.78 19.7 1.41 18.336 0.260
0.25 4.70 0.54 4.55 11.548 0.47 11.08 0.231 0.25 4.70 0.54 6.77 17.2 1.41 15.772 0.329
0.33 4.70 0.54 4.02 10.203 0.47 9.733 0.268 0.33 4.70 0.54 5.99 15.2 1.41 13.793 0.379
0.50 4.70 0.54 0.33 0.8249 0.47 0.355 0.015 0.50 4.70 0.54 4.84 12.3 1.41 10.874 0.453
0.66 4.70 0.54 2.71 6.878 0.47 6.408 0.352 0.66 4.70 0.54 4.05 10.3 1.41 8.8689 0.488
1.00 4.70 0.54 2.03 5.1521 0.47 4.682 0.390 1.00 4.70 0.54 3.03 7.7 1.41 6.2801 0.523
2.00 4.70 0.54 1.11 2.8172 0.47 2.347 0.391 2.00 4.70 0.54 1.87 4.7 1.41 3.3361 0.556
3.00 4.70 0.54 0.84 2.1319 0.47 1.662 0.415 3.00 4.70 0.54 1.42 3.6 1.41 2.194 0.548
6.00 4.70 0.54 0.50 1.269 0.47 0.799 0.400 6.00 4.70 0.54 0.85 2.2 1.41 0.7473 0.374
12.00 4.70 0.54 0.29 0.736 0.47 0.266 0.266 12.00 4.70 0.54 0.48 1.2 1.41 -0.192 -0.192
24.00 4.70 0.54 0.16 0.4061 0.47 -0.06 -0.128 24.00 4.70 0.54 0.27 0.7 1.41 -0.725 -1.449
0.415 0.556
18098 24220
D = 4" Orifice
Q=CA(2gh)^1/2
C =0.61
A =0.087
g =32.2
h =0.60
Q=0.33 cfs
Estimated 100-year flow (x1.25) =21.48 cfs
Q=(1.49/n)*(R^2/3)*A*(S^1/2)
Manning's "n" = 0.02
Bottom width =25
Height =0.45
Side slope (1/x) x=3
Slope (ft/ft)=0.0022
Wetted Perimeter = 27.846
Area =11.858
Hydraulic Radius =0.4258
Q=23.452
Area (acres) = Area (acres) =
Allow. Release Rate x0.1 (cfs) = Allow. Release Rate x0.3 (cfs) =
Residential Construction - 10475 Hussey Lane
Runoff Coef. =
10-Year 100-Year
10 Year Post-Developed Storm 100 Year Post-Developed Storm
Detention Volume Required
10-Year Event (acre-ft) = 100-Year Event (acre-ft) =
100-Year Event (ft^3) =
Detention Volume Provided
Surface Storage
Contour Area (S.F.)Average (S.F.)Vol. (acre-ft)
10-Year Event (ft^3) =
801.60 47260
4713 0.1082
11636 0.2671
Pond Spillway Calculations
801.00 45220
Total (acre-ft)=0.6374
RATIONAL DETENTION CALCULATIONS
4" Orifice Discharge Computations Equation
Total (ft^3)27764
801.25 46100
11415 0.2621
801.50 46990
10/17/19 Page 12
A=Drainage area 4.70 Ac
I=Post-development impervious percentage 48.0%
P=Precipitation 1.00 in
Rv=Volumetric Runoff Coefficient
Rv = 0.05 + .009 (I) =0.482 in/in
WQv=Water Quality Volume
WQv = (P) (Rv) (A) / 12 =0.19 ac-ft 0.21 Provided at
or 8227 ft^3 Elev. =801.20
ENp=Elevation of Normal Pool 801.00
ESt=Elevation of Water Quality 801.20
h=Height
Height (h) = (Enp - Es) / 2 =0.1 '
Q=Water Quality Release Rate (over 24 hours)
Q = (WQv * 43560) / (24 * 3600) =0.095 cfs
a=Q Orifice Equation
C * 2 * (g *h) ^0.5
C=Orifice constant 0.6
g=Gravity constant 32.2
a=Area of orifice
a=0.044 sq.ft.
d=Diameter of Orifice
d=0.237 '
or 2.848 "
Designed orifice = 2.5 inches
m Area Area Volume Volume
(msl)(sf)(ac)(cu-ft)(ac-ft)
801.00 45220 1.0381 0 0.0000
801.15 45730 1.0498 6814 0.1564
801.20 45900 1.0537 9103 0.2090
801.25 46070 1.0576 11400 0.2617
801.60 47260 1.0849 27716 0.6363
9103 0.2090
Total Storage Volume = 9103 cu-ft x 3 =
27309 cu-ft
Pond Volume (under NP) = 438325 cu-ft
Therefore, Total Pond Volume is greater than 3x WQv
WATER QUALITY DESIGN CALCULATIONS
Proposed Retention Pond
WQv TOTAL
WQ Storage Volume
10/17/19 Page 13
WATER QUALITY DESIGN CALCULATIONS
m Area Area Volume Volume
(msl)(sf)(ac)(cu-ft)(ac-ft)
801.00 45220 1.0381 0 0.0000
799.00 36755 0.8438 81747 1.8767
787.00 11480 0.2635 356577 8.1859
438325 10.06
Level Spreader Pipe
Total Flow leaving pond (entering spreader pipe) =0.40 ft^3 / sec
1" depth of flow leaving pipe =0.08 feet
1" deep flow per linear foot of pipe =4.8 ft^2 / sec
Total length of spreader pipe =10.0 feet
Velocity per linear foot of spreader pipe =0.48 foot / sec ( below maximum
1 ft / sec allowable
sheet flow velocity)
TOTAL VOLUME
Pond Volume
10/17/19 Page 14