HomeMy WebLinkAboutS000 GENERAL NOTESGENERALNOTES: Bl11LDING CRITERIA - 2015 INTERNATIONAL Bl11LDING CODE (IBC) �ESIGN LOA�S: ROOF DEAD LOAD . . . . . . . . . . . . . 20 PSF ROOF LIVE LOAD, SUBJECT TO MAINTENANCE PERSONNEL 'A' OR'B', WHICHEVER PRODUCES THE GREATER LOADS EFFECTS: AJ SURFACE LOAD UNIFORMLV DISTRIBUTED OVER ENTIRE ROOFSURFACE.. ..........20PSF BJ CONCENTRATED LOAD UNIFORMLV DISTRIBUTED OVER AN AREA OF 21/2 FEET BV 2 ii2 FEET AND LOCATED 50 AS TO PRODUCE THE MAXIMUM LOAD EFFECTS.... ......... 3�� LB PLATFORM DEAD LOAD ......... ..... ........ 20PSF PLATFORMLIVELOAD ......... ......... ............. 4�PSF GROUNDSNOWLOAD,PG 20PSF RAT-ROOF SNOW LOAD, PF 15.4 PSF MINIMUM SNOW LOAD, PM 20 PSF SNOWEXPOSUREFACTOR,Ce 1.0 SNOWLOADIMPORTANCEFACTOR,Is 1A THERMAL FACTOR, Ct 1.1 WIND DESIGN DATA ULTIMATEWINDSPEEDVuIt 115MPH ALLOWABLEWINDSPEEDVasd 89MPH WIND RISK CATEGORV II WIND EXPOSURE"B" BUILDING IS DESIGNED AS ENCLOSED (IPC =+/-0.18) COMPONENTS AND CLADDING (Kd = �.85) - EDGE ZONE IS �EFlNE� AS 3.0' FROM ANV BLDG CORNER OR ROOF EDGE. - THEVALUESSHOWNeELOWAREULTIMATEVALUES.MULTIPLVBV0.6T00BTAINASDVALUES. Design Wind Pressure (psf): Effective Wind Area (sqft) Walls: 70 20 50 100 200 500 + ig.q 17.5 16.5 16.0 ifi.0 160 Interior Gea4 199 _�y� _�80 -172 -16.4 -160��� Edge AreaS � 18'4 »-5 16.5 ifi.0 1fi0 16.0 ' '24.5 -22.8 -207 -19.1 -174 -16.0 Roof: 70 20 50 100 200 500 + 16.� 160 16.0 16.0 1fi0 16.0 Interior Prea 1 -20.1 -19.5 -08.9 -18.4 -i8A ...... -18A.... + 18.4 17.5 16.5 16.0 16.0 i60 Edge Area 2 -33.7 30.1 -25.3 -21.8 -21.8 -21.8.... + �g.q 17.5 16.5 16.0 16.0 160 Comer Fvea3 -33] -30.1 -25.3 -21.8 -21�.8 -21.8��� Overhang: 10 20 50 '100 200 500 + 16.0 16.0 16.0 16.0 16.0 i60 Interior Nea 1 -28.9 -28.4 -27] -272 -23.6 -18.8.... + 16.0 16.0 16.0 16.0 16.0 16.0 Edge Gea 2 -28.9 -28.4 -27] -272 -23.6....... -18.8.... + i60 16.0 16.0 i60 ifi.0 16.0 Comer Area3 ����-076 -374 -23.8 -16.0 � -16.0 -160 Parapet Design Pressure (psf): Effective Wind Area (sqft) Parapel: 10 20 50 700 200 500 + 56 2 50.8 43.7 38 3 37.3 36.0 Edge Gea 2 � - � � ...39.3 37.3 347.......327 ......307 -28.1 + 56 2 50.8 43 7 38 3 37.3 36.0 Comer Nea3 ��A49 _q2_0�� -38.0 �35.0 32.0 -28.1 EARTHQUAKE DESIGN DATA OCCUPANCVCATEGORV=11 Ss=0.152g Si =0.083g SEISMICDESIGNCATEGORV=C Sds=0.i62g Sd1=0.133g SEISMIC IMPORTANCE FACTOR, le= 1.0 SITE CLASS= D (ASSIIMED) (Fa=�.B� W =2R�) ANALVSIS: EOUIVALENT LATERAL FORCE PROCEDURE BASIC SEISMIC FORCE RESISTING SVSTEM: WOOD STRUCTURAL PANELS BASE SHEARS: V= 4 KIPS RESPONSE MODIFICATION COEFFICIENT, R= 6S SEISMIC RESPONSE COEFFlQENT. Cs=0.025 GENERAL: 1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL SHOPDRAWINGSANDSPEQFlCATIONS. 2. GENERALCONTRACTORSHALLREVIEWANDSTAMPALLSHOPDRAWINGSBEFORESUBMITTALFOR APPROVAL SHOPDRAWINGS.REVIEWEDBVTHEGENERALCONTRACTOR,FORREWFORQNG.JOIST, DECK, 8 STRUCTURAL MEMBERS SHALL BE SUBMITTED TO THE ARCHITECT AND A STAMPED APPROVAL RECEIVEDPRIORTOFABRICATION. ERECTIONSHALLBEMADEFROMAPPROVEDSHOPDRAWINGS ONLV. & FABRICATORSHALLHIGHLIGHTCHANGESMADEINSHOPDRAWINGSWHICHDONOTCOMPLVWITHTHE DESIGN DRAWINGS. 4. ALLDIMENSIONSANDCONDITIONSMUSTBEVERIREDINTHERELDANDANVDISCREPANQESSHALLBE BROIIGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE AFFECTED PART OF WORK. 5. A RECOR� SET OF SHOP �RAWINGS SHALL BE KEPT IN THE FIEL� BV THE GENERAL CONTRACTOR. 6. THE CONTRACTOR SHALL VERIFV ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECT'S PLANS BEFORE STARTING WORK. ]. VERIFVALLMECHANICALEOUIPMENTWEIGHTS,LOCATIONSANDASSOCIATEDOPENINGSWITH MECHANICALCONTRACTOR. NOTIFVENGWEERIFACTUAL WEIGHTFXCEEDSTHEDESIGNWEIGHT SHOWN ON THE DRAWINGS. e. CONTRACTORSHALLPROVIDEANDMAINTAINTEMPORARVBRACING,SHORING,GUVING,ETC.AND OTHERMETHODSTOPREVENTEXCESSNESTRESSESDURINGCONSTRUCTION. THESEPROVISIONS ARE TO REMAIN IN PLACE UNTIL SUFFlCIENT PERMANENT MEMBERS ARE CONSTRUCTED TO INSURE THE SAFETV OF THE STRUCTURE. 9. UNLESSOTHERWISENOTED.DETAILSSHOWNONANVDRAWINGARETOBECONSIDEREDTVPICALFOR ALL SIMILAR CONDITIONS. u 0 u 1. ANALLOWABLEBEARINGCAPACITVOF2,���PSFHASBEENASSUMEDANDSHALLBECONFIRMED BV A OUALIFlED SOILS ENGWEER PRIOR TO PLACEMENT OF CONCRETE. 2. ALL FOOTINGS, OR PORTIONS THERWF, BELOW GRADE MAV BE EARTH FORMED BV NEAT EXCAVATIONS. 3. ALLFOOTINGSSHALLBEARONUNDISTURBEDEARTHORENGWEEREDRLLATELEVATIONS SHOWN ON PLANS AND DETAILS. ALL FOOTINGS AND SLABS SHALL BEAR ON COMPACTED SIIBGRADEASDIRECTEDBVpl1ALIFIEDSOILSENGINEER. THEMOISTIIRERETARDERSHALLBE PLACED BENJEEN THE STONE AND THE SLAB. 4. SPREAD FOOTINGS SHALL BE CENTERED ON COLUMNS, UNLESS NOTED OTHERWISE. 5. PROXIMITV OF UTILITV TRENCHES TO THE BUILDING FOUNDATION SVSTEM SHALL BE AS APPROVED BV THE ARCHITECT AND/OR SOILS ENGW EER TO INSURE THE INTEGRITV OF THE RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�j sv�� �\'��v�N�nl.� � CONCRETE WORK: 1. CONCRETESHALLHAVETHEMINIMUMSTRENGTHANDMEETTHEPROPERTIESASDESCRIBEDBELOW FOR THE VARIOUS CLASSES OF CONCRETE'. MIXTVPE SUPERP SLUMP ICRATIO COMMENT LOCATION 4000 P51 N/A 4" MAX OAS MAX NOTE 13 FTG, S.O.G. 2. 3. 4. 5. 6. 8 9. i o. 11 12. 13. ,4. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE CURRENT "ACI MANUAL OF CONCRETE PLACEMENT". PORTLAND CEMENT SHALL CONFORM TO ASTM C150, TVPE I OR II. ALL AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL MEET ASTM C33. ALL REWFORQNG SHALL MEET ASTM A615, GRADE 60. ALLREWFORQNGSHALLBEDETAILED FABRICATEDANDPLACEDPERCRSI ANDAQSTANDARDS W C W DING CONCRETE COV ER AND BAR SIIPPORTS (DESIRED METHOD OF SIIPPORTI NG TOP BARS IN THICK MATS SHALL BE VERIFIED WITH ENGINEER J PROVIDE CORNER BARS AT ALL FOOTINGS AND WALL INTERSECTIONS TO MATCH HOPoZONTAL REINFORCING IN SIZE AND SPACING. AT INTERSECTIONSOFCONTINUOUSSPREADFOOTINGS EXTENDALLBARSTOFARSIDEOF INTERSECTINGFOOTING. LAPBARS ATALLSPLICES,INCLUDINGCORNERBARSANDDOWELS,IN ACCORDANCE WITH SPLICE SCHEDULE OR IN LIEU THEREOF40 BAR DIAMETERS. CONCRETE PROTECTION FOR REINFORCING: 3" AT EARTH FORMED FOOTINGS 2" AT FORMED SURFACES LATER E%POSED TO SOIL. ALUMINUM SHALL NOT BE EMBEDDED IN ANV CONCRETE. NO HOLES OR OPENINGS THROUGH FOUNDATION WALL AND/OR FOOTINGS WITHOUT ENGINEERS APPROVAL. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED 3l4". DETAILS WHICH ARE NOT SHOWN SHALL BE ACCORDING TO SPEQFlCATION AND CODE OF THE AMERICAN CONCRETE INSTITUTE. RESULTS OF ALL CONCRETE COMPRESSNE STRENGTH TESTS SHALL BE AVAILABLE ON THE JOB SITE Foa aeview ev rHe iNSPecroa. INDICATED CONCRETE TVPES SHALL HAVE ALLOWABLE UNIT SHRINKAGE OF �.�3 o AT 28 DAVS. E%TERIOR CONCRETE SLAB SHALL HAVE 4 TO 6 PERCENT ENTR4IN ED AIR. FASTENERS: 1. ALL STEEL PLATE WASHERS SHALL BE HOT DIPPED GALVANIZED AND MEETASTM A36. 2. ALL FASTENERS (INCL NAILS)AND HARDWARE IN CONTACT WITH CONCRETE, IN CONTACT WITH PRESSURE TREATED WOOD USED W EXTERIOR FRAMING OR EXPOSED TO THE ENVIRONMENT SHALL BE STAWLESS STEEL OR AT A MINIMIIM HOT DIPPED GALVANIZED. 3. ALL STEEL BOLTS SHALL BE HOT DIPPED GALVANIZED AND MEET ASTM A30]. BOLT HOLES SHALL BE A MA%IMIIM 1/16" LARGER THAN THE BOLT �IAMETER AN� SHALL BE PRE-�PoLLE� PRIOR TO �ELIVERV. BOLTS SHALL NOT BE FORQBLV DRNEN. 4. ALL ANCHOR RODS SHALL BE HOT DIPPED GALVANIZED AND MEETA36. 5. ALL LAG SCREWS SHALL BE HOT DIPPED GALVANIZED AND CONFORM TO STANDARD ANSI/ASME B182.1-1981. THECLEARANCEHOLEFORTHESHANKSHALLHAVETHESAMEDIAMETERASTHE SHANK,ANDTHESAMEDEPTHOFPENETRATIONASTHELENGTHOFUNTHREADEDSHANK. THELEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER W UAL TO 60% T015% OF THE SHANK DIAMETER AND A LENGTH WUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE THREADED PORTION OF THE LAG SCREW SHALL BE INSERTED IN ITS HOLE BV TURNING WITH A WRENCH,NOTBVDRIVINGWITHAHAMMER. SOAPOROTHERLUBRICANTSHALLBEUSEDONTHELAG SCREWS OR IN THE LEAD HOLES TO FACILITATE INSERTION AND PREVENT DAMAGE TO THE LAG SCREW. 6. INSTALL ALL PROPRIETARV PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. ]. SIMPSONSTRONG-TIECONNECTORSARESPECIFICALLVREpUIREDTOMEETTHESTRIICTURAL CALCIILATIONSOFPLAN. BEFORESIIBSTITIITINGANOTHERBRAND,CONFIRMLOADCAPACITVBASED UPON RELIABLE PIIBLISHED DATA OR CALCULATIONS. THE ENGINEER OF RECORD (EOR) SHALL EVALUATE AND GNE W RITTE N APPROVAL FOR SUBSTITUTION PRIOR TO INSTALLATION. WALL FRAMING: 1. ALLBEAMSANDJOISTSSHALLBESEATCUTFORFULLIINIFORMBEARINGATSUPPORTS,BEAMSEATS AND COLUMN CAPS. 2. REFPLANFORSTUDTVPEANDSPAQNG. 3. ALL WOOD IN CONTACT WITH CONCRETE, MASONRV, OR GRADE SHALL BE PRESERVATNE TREATED. 4. ALL BOLTED OR NAILED STRAP CONNECTIONS SHALL HAVE AN EpUAL NUMBER OF BOLTS OR NAILS EACHSIDEOFTHESPLICEJOINT. THEFIRSTBOLTORNAILFROMEACHSIDEOFTHESPLICEDOR TREATED MEMBER SHALL BE EpUAL DISTANCE FROM THE SPLICE. STRAPS USING i6d NAILS ON 2x MATERIAL SHALL BE INSTALLED ON THE 1-1/2" EDGE OF THE MEMBER. 5. THECONTRACTORSHALLVERIFVTHATTHEMOISTURECONTENTOFALLFRAMINGLUMBERAND PLVWOOD MEET THE REOUIREMENTS OF THE SPECS. AT THE TIME OF INSTALLATION AND AT CLOS6IN. 6. PROVIDE DOUBLE STUDS @ DOUBLE TRUSSES OR RAFTERS, TVPIGAL. SEE ROOFAND FLOOR FRAMING PLANS FOR TRU55 AND RAFTER LOCATIONS. 1. AMINIMUMOFONEANCHORSHALLBEPROVIDEDWITHIN6T0121NCHESOFEACHENDOFSOLE PLATE AND SHALL BE LOCATED WITHIN 12 INCHES OF ALL CORNERS. LUMBER 8 WOOD STRUCTUR4L PANEL SHEATHING: 1. ALLROOF&FLOORSHEATHINGSHALLBEINSTALLEDWITHLONGDIMENSIONPERPENDIWLARTO FRAMING AND END JOINTS SHALL BE STAGGERED. 2. ALL ROOF DECK SHALL BE APA RATED 40I20. MIN. -SIS" EXPOSURE 1 GRADE WOOD STRUCTURAL PANELS ATTACHED WITH Sd RING SHANK NAILS AT 6" O.G AT SUPPORTED EDGES, NAIL SPAQNG AT DIAPHRAGM BOIINDARV IS 6" O.G AND 12" O.G IN FIELD. INSTALL PSC SHEATHING CLIPS BV SIMPSON STRONGTIE DET 2IS000 AT ALL UNSUPPORTED EDGES OF ROOF DECK ONE PER SPAN . ( ) ( ) 3. PLATFORMSHEATHINGSHALLBE3/4"T&GWOODSTRIICTIIRALPANELSWITHE%TERIORGWE. ELEVATED PLATFORMS'. ATTACH TO ALL SUPPORTED EDGES WITH 10d NAILS AT 6" O.C., NAIL SPAQNG AT DIAPHRAGM BOUNDARV IS 6" O.C., AND RELD NAILINGAT 12" O.C. WITH MIN. 1 1/2" PENETRATION INTO FRAMING MEMBER. 4. OPENINGS IN HORIZONTAL DIAPHRAGMS WITH A DIMENSION PERPENDICULAR TO THE JOISTS GREATER THAN 4 FEET SHALL BE BLOCKED BEVOND THE HEADERS AND METAL TIES NOT LE55 THAN 18 GAGE BV 1 1/2" WIDE WITH (8) i8tl COMMON NAILS ON EACH SIDE OF THE HEADER-JOIST INTERSECTION SHALL BE PROVIDED. 5. AS A MINIMUM ANCHORAND NAIL FR4MING SHALL COMPLV WITH THE SCHEDULE ON THIS SHEET. 6. ALL MULTIPLE PIECE WOOD BEAMS SHALL BE CONNECTED TOGETHER WITH (3) ROWS OF GALV. 12d COMMON W IRE NAI LS @ 12" O.G (lINO). 1. ALL LUMBER DESIGNATED AS'PSL" SHALL BE PARALLAM PARALLEL STRAND LUMBER WITH E=1,800,000 OR 2,��Q��� PSI AND Fb=24�� PSI AT 100 % LOAD DURATION FOR SERVICE LEVEL 2(OR APPRV EQUAL). ALL LUMBER DESIGNATED AS "LVL" SHALL BE MICROLLAM LAMINATED VENEER LUMBER WITH E=1,900,000 PSI AND Fb=ffi00 PSI AT 100% LOAD DIIRATION. 8. IINLESS NOTED OTHERWISE, ALL W MBER SHALL BE p2 SOIITHERN VELLOW PINE AND SHALL HAVE A MA%IMUM MOISTURE CONTENT OF 19%. 9. REFERENCE PLANS AND DETAILS FOR SIMPSON STRONG-TIE CONNECTORS. 10. ALLLUMBEREXPOSEDTOTHEEXTERIORENVIRONMENTSHALLBEPRESSUREIMPREGNATEDTOA MINIMUM RETENTION OF 025 LBS. OF ACO OR MCO PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTV pUALITV MARK "ABOVE GROUND USE" 11. ALL WMBER W CONTACT WITH THE GROUND ICONCRETE I MASONRV SHALL BE PRESSURE IMPREGNATED TO A MINIMUM RETENTION OF 0.40 LBS. OF ACQ OR MCQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTV OUALITV MARK "GROUND CONTACT USEI' 12 REF.STANDARDAWPAC2ANDASTMDI]6�FORPRESSURETREATMENTOFTIMBERPRODUCTS. MASONRV: 1. HOLLOW CONCRETE BLOCK (MASONRV) UNITS SHALL CONFORM TO ASTM C9q LIGHTWEIGHT, TVPE N-1 WITH A MINIMUM COMPRESSNE STRENGTH OF 19�� PSI ON THE NETAREA(fm = 15�� PSI). 2. ALL MORTAR FOR USE IN MASONRV SHALL CONFORM TO ASTM C210, TVPE M OR 5. ALL GROUT FOR USE IN MASONRV SHALL W NFORM TO ASTM C416. MIN. 2500 P51 AND NOT LE55 THAN A 6-ii2 SACK MIX. 3. REWFORQNG BARS SHALL MEET ASTM A615, GRADE 60. 4. REINFORCE MASONRV AT BEARING POINTS OF ALL BEAMS, LINTELS, ETC. WITH 2p5 (CONTINUOUS TO FOIINDATION) IN EACH BLOCK CORE BENEATH BEARING PLATES (IINLESS NOTED OTHERWISE). 5. PROVIDE AT LEAST 2 VERTICAL BARS AT EACH END, CORNERS, AND INTERSECTIONS OFALL WALLS. SEE WALL SECTIONS FORTVPICAL VERTICAL REWFORQNG. 6. BOND BEAM BLOCKS SHALL MEAN OPEN BOTTOM LINTELS UNLESS NOTED OTHERWISE.PROVIDE METAL LATH IN JOINTS BELOW BOTTOM OF BOND BEAM OVERTHOSE CELLS THAT ARE NOT GROUT RLLED. ]. VERTICALAND HORIZONTAL REINFORCING SHALL BE CONTINl10lIS AND LAPPEDA MINIMIIM OF 36 BAR DIAMETERS. 8. HOLD VERTICAL BARS STRAIGHT, TRUE, AND ACCURATE IN ALL WALLS AS DETAILEDJNSTALL REBAR POSITIONERS @ 4'-0" OA. MA%IMUM THAT ARE DESIGNED TO HOLD REBAR IN PROPER LOCATION W ITHIN THE CELL PRIOR TO GROUTING. 9. PROVIDEAMINIMUMOFI/2"GROUTBETWEENMAINREWFORCINGANDMASONRVUNITS. 1�. PROVIDESTANDARDGAGETRUSSTVPEJOINTREINFORCEMENTATI6"O.C. 11. ALLREWFORCEDMASONRVCOLUMNANDWALLSECTIONSRWUIREDOWELSFROMFOOTING.SAMESIZEAND QUANTITV AS VERTICAL REWFORCEMENT IN COWMN OR WALL UNLE55 NOTED OTHERWISE. 12. GROUTRLLALLCELLS.ALLWALLSBELOWGRADESLUSHJOINTBETWEENWVTHESBELOWGRADE. 13. ALL CMU SHALL BE LAID IN RUNNING BOND PATTERN. 14. GROUT FILLALL CELLS THAT CONTAIN REINFORCING. MASONRV VENEER TIES 1. FORADJUSTABLETWO-PIECEANCHORS,ANCHORSOFWIRESIZEWI]AND22GAGECORRUGATESHEETMETAL ANCHORS. PROV IDE AT LEAST ONE ANCHOR FOR EACH 2.615Q FT OF WALL AREA. 2. SPACE ANCHORS AT A MAXIMUM OF 321N. HORIZONTALLV AND i81N. VERTICALLV. 3. PROVIDEADDITIONALANCHORSAROUNDOPENINGSLARGERTHAN161N.WEITHERDIRECTION.SPACEANCHORS AROIINDPERIMETEROFOPENINGATAMA%IMIIMOF361N.ONCENTER. PLACEANCHORSWITHIN121N.OF OPENINGS. VENEER LINTEL SCHEDULE MAX.QEAR STEELVENEERLINTEL SPAN WHERE APPUCABLE 5'-0"ORLESS L4x4x3/BLLV ��'-8"MAX Vx4x3/BLLV VENEER LINTEL NOTES: ALL STEEL BRICK VENEER LINTELS SHALL BE HOT-DIPPED GALVANIZED AND HAVE A MINIMUM BEARING OF 61NCHES AT EACH END. RE WOOD TRUSSES: 1. ALL PREFABRICATED TRUSSES SHALL BE DESIGNEDTO MEET THE LOADINGS SPEQRED. FABRICATION AND ERECTION SHALL BE PER TRUSS PLATE INSTITUTE RECOMMENDATIONS AS CONTAWED IN THEAPPROPRIATE PUBLICATIONS. 2 SHOPDRAWINGSANDCALCULATIONSSHALLBESUBMITTEDFOREACHTYPEOFTRUSSSPEQFlED AND SHALL BEAR THE SEAL OFA REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE OF THEPRaECT. 3. ALL LUMBER USED IN THE MANUFACTURING OF WOOD TRUSSES SHALL BE tl2 SOUTHERN VELLOW PWE OR BETTER. 4. PROVIDEALLTEMPORARVANDPERMANENTTRIISSBRACINGANDBRIDGINGASREpl11REDAND SHOWN ON THE TRIISS MANIIFACTIIRERS SHOP �RAWINGS. BRACING SHOWN ON STRIICTIIRAL DRAWINGS IS IN ADDITION TO ANV BRAQNG SHOWN ON THE SHOP DRAWINGS. 5. PROVIDE2x4CONTINUOUSBOTTOMCHORD/CEILINGBRAQNGAT4FEETO.C.MAXIMUMWHERE GVPSUM BOARD IS NOT ATTACHED DIRECTLV TO BOTTOM CHORD OF WOOD TRUSSES. 6. INSTALL STRONG BACKS, BRACING ANDIOR BRIDGING PRIOR TO DECK INSTALLATION AND AS TRUSSES AREERECTED. FASTENALLBRACINGTOEACHTRUSS. �REFERENCE REFERENCE� COMPONENTS& COMPONENTS& CLADDINGTABLE CLADDINGTABLE REFERENCE COMPONENTS & CLADD WG TABLE 20 PSF (MINJ l0 PSF �aaa�v ro roa cNoao� 10 PSF (APPLVTO BOTfOM CHORDJ WIND LOA� PARAPET wwo �oAo LIVE LOAD SNOW LOAD (SEE D WGRAMJ DEADLOAD ������ NOTE:ALSOAPPLVROOFTOPANDSUSPENDEDPOINTLOADS. WEIGHTANDLOCATIONOFUNITSAS NOTEDARE SHOWN ON THE ROOF FRAMING PLAN AND ARE NOT INCWDED IN THEA80VE LOAOING DIAGRAM. VERIFV THESE LOADS WITH MECHANICAL SUPPLIER BEFORE DESIGNING TRUSS. NOTE'. THIS DIAGRAM IS A SCHEMATIC SHOWING THE APPLICATION OF LOADS STATED HEREIN. LOADS SHALL BE COMBINEDAS PROVIDED BV THE GOVERNING BUILDING CODE TO DETERMINE THE MOST UNFAVOR4BLE EFFECT. TVPICAL WOOD ROOF TRIISS DIAGRAM BLOCKINGATALL pROVIDEWOOD STUDWALL PANELEDGES STRUCTURALPANELS, FRAMING REF PLAN FOR SHEATHING TVPE AND FASTENER PATTERN � TO FRAMING II II II I I �I II II II II II I SHAML BE FASTENED NOTE . .. . .. .. . . . . .. . . . . . . . TO SHEATHING W/ ORIENTATION OF WALL SHEATHING SHALL BE NAILS @ 12" OC (TVP) AT CONTRACTOR'S OPTION'. HOWEVER, BLOCKING SHALL BE INSTALLED AT ALL PANEL EDGES NOT BACKED BV WALL FRAMING. TVPICAL E%TERIOR AND SHEAR WALL ATTACHMENT DET�Nor ro sca�e s000 Pd = 2o psf W=49ft Pd = 28 psf Pf=15Apsf W=6.8ft Ptl = 28 psf W=6Bft Pd = 20 psf W = 4.9 f[ SNOW LOAD DIAGRAM DET�NOT TO SCALE 5000 FASTENING SCHEDIILE: 1. TRUSSTOTOPPLATE,TOENAIL 2 PLATFORM JOIST TO TOP PLATE, TOENAIL z 3. BLOCKINGTOR4FTEWTRUSS,TOENAIL � � 4. RIM BOARD TO RAFTER/TRIISS, END NAIL O 5. TOP PLATE TO TOP PLATE, FACE NAIL � 6. TOP PLATE AT INTERSECTIONS, FACE NAIL ]. DOUBLESTUDS,FACENAIL 8. DOUBLETOP PLATES, LAP SPLICE z 9. TOPORBOTTOMPLATETOSTUDS,ENDNAIL � � 10. SOLEPLATETOJOISTORBLOCKINGATSHEARWALL,FN � a � � 11. BUILT-UPCORNERWITH35TUD5 z ¢ 12. BUILT-UP CORNER WITH 4 STUDS � � w � O W^ V ZQ � O W 2 � c� Uz Q Z = JQm OU -�o �� �=a ZO _ LnU? O� � LLI�J WY Yrn� �� Qa'� � �d�U � � BRIT� A 5 5 O C I A T E 5 consW�-ng eng-neer 1100 pueensborough Blvd. Sui[e 2�2 ML Pleasan[, SC 29464 (843) 284-W00 BPA Job No. 190668 l ��a����� �erzm z�we, cn am ��w� ��s _ �: = r - ' sn�rt a ¢' ♦ W. 9 ryDl b A A ���. ��/OV��,���'. 8/r/�/% � NAILINGlINO: �� �� 4-10d 4-10tl 2-Sd 2-�Bd 3��d PER FOOT 6-10d aaows i od @ a• oc REF DET 1�IS1�� 3-i6d REF SCHEDULE ON PLAN 2-ROWS i6tl @ 12OC 2-ROWS 16d @ 12OC, EA SIDE PLVWOODROOF DECKSHEATHING ��1I8" GAP (1) SI MPSON PSCL PANEL SHEATHING CLIPS EQl1ALLV SPACED BETWEEN EACH RAFTEPoSUPPORT TYPICAL PLVWOOD EDGE SUPPORT DET�NOTTO SCALE 5��� TVPICAL-BRIDGING LAP NOTE: REFER TO TRIISS SCHEMATIC ON SHT 5000 DETAIL 3 NOT TO SCALE 5000 � Ptl = 28 psf W=68ft Pd = 20 psf W=49ft o8-z,-zo,9 GENERAL NOTES Y�I�I17 onrE: 12/12/19