Loading...
HomeMy WebLinkAbout19015_Bharat_Patel_ElecSYMBOLS, ABBREVIATIONS, AND GENERAL SPECIFICATIONSSOME SYMBOLS AND/OR ABBREVIATIONS MAY NOT BE USED ON THIS PROJECTSTANDARD ABBREVIATIONS A AMPERES AC ALTERNATING CURRENT AF AMPERE FUSE AFC ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM ARCH ARCHITECT(URAL) ATS AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AVG AVERAGE BFC BELOW FINISHED CEILING BFG BELOW FINISHED GRADE BHP BRAKE HORSEPOWER BPS BOOSTER POWER SUPPLY BTM BOTTOM C CONDUIT CB CIRCUIT BREAKER C/C CENTER TO CENTER CCTV CLOSED CIRCUIT TELEVISION CF CUBIC FEET CKT CIRCUIT CL CENTERLINE CLG CEILING COMM COMMUNICATIONS COMP COMPRESSOR CONT CONTINUOUS CR CRITICAL LOAD CT CURRENT TRANSFORMER CU COPPER DC DIRECT CURRENT DP DISTRIBUTION PANEL DPST DOUBLE POLE, SINGLE THROW DWG DRAWING DWH DOMESTIC WATER HEATER EC ELECTRICAL CONTRACTOR EF EXHAUST FAN EGC EQUIPMENT GROUNDING CONDUCTOR EM EMERGENCY (LOAD) EPO EMERGENCY POWER OFF EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EX EXIT EXH EXHAUST EXP EXPLOSIONPROOF EXT EXTERIOR FA FIRE ALARM FAAP FA ANNUNCIATOR PANEL FACP FA CONTROL PANEL FC FLAT CABLE FCU FAN COIL UNIT FFC FOOD FACILITY CONTRACTOR FFS FOOD FACILITY SUPPLIER FHC FIRE HOSE CABINET FIXT FIXTURE FLUOR FLUORESCENT FPC FIRE PROTECTION CONTRACTOR FSS FUSED SAFETY SWITCH FTG FOOTING FTL FEED THROUGH LUGS FV FULL VOLTAGE G, GND GROUND GALV GALVANIZED GC GENERAL CONTRACTOR GEC GROUNDING ELECTRODE CONDUCTOR GEN GENERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTOR GFP GROUND FAULT PROTECTION GTB GENERATOR TAP BOX H, HV HIGH VOLTAGE HID HIGH INTENSITY DISCHARGE HO HAND OPERATED HOA HAND-OFF-AUTO HP HORSEPOWER HPS HIGH PRESSURE SODIUM HTR HEATER Hz HERTZ IC INTERCOM ID INSIDE DIAMETER ISG ISOLATED GROUND J, JB JUNCTION BOX KEC KITCHEN EQUIPMENT CONTRACTOR kV KILOVOLTS kVA KILOVOLT-AMPERES kVAR KILOVOLT-AMPERES REACTIVE kW KILOWATTS L or LV LOW VOLTAGE LB POUND LCP LIGHTING CONTROL PANEL LF LINEAR FEET LP LIGHTING PANEL LS LIFE SAFETY LOAD LT LIGHT LTG LIGHTING MAX MAXIMUM MC MECHANICAL CONTRACTOR MCB MAIN CIRCUIT BREAKER MCCB MOLDED CASE CIRCUIT BREAKER MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MIN MINIMUM MISC MISCELLANEOUS MLO MAIN LUG ONLY MSB MAIN SWITCHBOARD NIC NOT IN CONTRACT OCP OVERCURRENT PROTECTION OD OUTSIDE DIAMETER OF/CI OWNER FURNISHED, CONTRACTOR INSTALLED OF/OI OWNER FURNISHED, OWNER INSTALLED OR OPERATING ROOM P POLE PB PUSH BUTTON PC PLUMBING CONTRACTOR PF POWER FACTOR PH, Φ, Ø PHASE PIV POST INDICATOR VALVE PL PILOT LIGHT PNL PANELBOARD PREFAB PREFABRICATED PT PNEUMATIC TUBE PTS PNEUMATIC TUBE STATION PTZ PAN-TILT-ZOOM PW PART WINDING PWR POWER RCPT RECEPTACLE REF REFRIGERATOR RM ROOM RP RECEPTACLE PANEL RPM REVOLUTIONS PER MINUTE SCCR SHORT CIRCUIT CURRENT RATING SG SURGE GUARD SN SOLID NEUTRAL SPEC SPECIFICATIONS SQ FT SQUARE FEET SS SAFETY SWITCH SSBJ SUPPLY SIDE BONDING JUMPER STD STANDARD STN STATION STR STRUCTUR(E),(AL) SUSP SUSPENDED SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TCC TEMPERATURE CONTROL (CONTRACTOR), (CABINET) TELE TELECOMMUNICATION TEMP TEMPORARY TV TELEVISION TYP TYPICAL UCR UNDER COUNTER REFRIGERATOR UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VFD VARIABLE FREQUENCY DRIVE VP VAPORPROOF W/ WITH W/O WITHOUT WP WEATHERPROOF WTR WATER Z IMPEDANCE ADA ACCESSIBLE ROOM - ALL OPERABLE DEVICES SHALL BE MOUNTED BETWEEN 18" AFF TO BOTTOM AND 48" AFF TO TOP OF DEVICE. HEARING IMPAIRED COMMUNICATIONS FEATURE ROOM - VISUAL NOTIFICATION REQUIRED FOR AS SHOWN ON PLANS. KEYED DEMOLITION PLAN NOTE KEYED NEW WORK PLAN NOTE 01 01 SECTION VIEW REFERENCE VIEW REFERENCE, INCLUDING DETAILS & ENLARGED PLANS 1 E-301 1 E-501 1 / E-301 VIEW REFERENCE TAG GENERAL DRAWING ANNOTATIONS 15. ALL WIRING SHALL BE INSTALLED PARALLEL & PERPINDICULAR TO THE BUILDING STRUCTURAL MEMBERS, EXCEPT WHERE INSTALLED UNDERGROUND. 16. A DEDICATED COPPER OR ALUMINUM EGC SHALL BE INSTALLED IN ALL RACEWAYS, EXCEPT IN SERVICE ENTRANCE CONDUITS. PARTICULAR CARE SHALL BE TAKEN TO ELIMINATE OBJECTIONAL CURRENT, SEE GROUNDING & BONDING DETAILS FOR SITE SPECIFIC REQUIREMENTS. 17. IT SHALL BE THE EC'S RESPONSIBILITY TO REVIEW CONDUIT SIZES AND WIRE AMPACITY PRIOR TO INSTALLATION, TO ENSURE A CODE-COMPLIANT INSTALLATION. 18. IT SHALL BE THE EC'S RESPONSIBILITY TO CONTACT THE DESIGNER WITH ANY QUESTIONS, CONCERNS, OR PROPOSED CHANGES BEFORE COMMENCING WORK. 19. CIRCUITS MAY BE COMBINED IN CONDUITS, CABLES, OR RACEWAYS, PROVIDED THAT THE CONDUCTORS ARE PROPERLY DERATED & ALL RACEWAYS ARE SIZED PER THE NEC. 20. CIRCUITS ARE SIZED FOR VOLTAGE DROP BASED ON ESTIMATED ROUTING. THE EC SHALL VERIFY THAT THE ACTUAL ROUTING CHOSEN COMPENSATES FOR VOLTAGE DROP AS FOLLOWS: A. ALL CONDUCTORS SHALL BE SIZED TO PREVENT EXCESSIVE VOLTAGE DROP. FEEDERS SHALL NOT EXCEED 2% VOLTAGE DROP & BRANCH CIRCUITS SHALL NOT EXCEED 3% VOLTAGE DROP. B. IN GENERAL, CONDUCTORS SHALL NOT BE REQUIRED TO INCREASE MORE THAN TWO (2) SIZES FOR THIS PURPOSE, UNLESS NOTED OTHERWISE. C. THE EGC SHALL INCREASE PROPORTIONALLY FROM THE SIZE REQUIRED BY THE NEC, AS REQUIRED BY NEC 250.122(B). 21. WIRES SHALL BE COLOR CODED AS FOLLOWS, OR AS REQUIRED BY THE AHJ: A. 240/120V SYSTEMS = BLACK (L1), RED (L2), WHITE (N) B. 208Y/120V SYSTEMS = BLACK (A), RED (B), BLUE (C), WHITE (N) C. 240D/120V SYSTEMS = BLACK (A), ORANGE (B), BLUE (C), WHITE (N) D. 480Y/277V SYSTEMS = BROWN (A), ORANGE OR PURPLE (B), YELLOW (C), GRAY (N) 22. ALL PANELBOARDS, SWITCHBOARDS, AND SWITCHGEAR SHALL HAVE A PERMANENT LEGEND SHOWING THE DESIGNATED CONDUCTOR COLORS, AS REQUIRED BY NEC 210.5(C). 23. WIRING SHALL BE #12 AWG COPPER, UNO. IN ALL CASES, THE EC SHALL VERIFY THE CORRECT SIZE WIRING IS INSTALLED, FOR A CODE-COMPLIANT INSTALLATION. 01. ALL MATERIAL & WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES, SPECIFICATIONS, LOCAL ORDINANCES, AND ACCEPTED INDUSTRY STANDARDS. 02. THIS PROJECT CONSISTS OF TWO PARTS: THE CONTRACT DRAWINGS & THE PROJECT SPECIFICATIONS. WHERE THESE DOCUMENTS ARE NOT IN AGREEMENT, THE MOST STRINGENT CONDITION SHALL APPLY. IN ALL CASES, THE EC SHALL REQUEST WRITTEN CLARIFICATION. 03. ALTHOUGH NOT ALL BRANCH WIRING & CONDUIT ARE SHOWN ON THESE DRAWINGS, IT IS THE INTENT OF THESE DOCUMENTS THAT A COMPLETE AND FUNCTIONING BRANCH WIRING SYSTEM BE INSTALLED. 04. ALL CONDUITS, CABINETS, CABLES, AND BOXES SHALL BE SECURELY FASTENED AND SUPPORTED PER THE NEC. 05. ALL DIMENSIONS SHALL BE OBTAINED FROM ARCHITECTURAL AND CIVIL SITE PLANS. IN NO CASE SHALL THE ELECTRICAL DRAWINGS BE SCALED. 06. ALL DIMENSIONS SHOWN SHALL BE TO THE CENTERLINE OF THE EQUIPMENT OR DEVICE BOX, UNLESS NOTED OTHERWISE. 07. VERIFY ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHERS & CONNECTED BY ELECTRICAL CONTRACTOR, PRIOR TO INSTALLATION OF WIRING, INCLUDING RECEIVING & REVIEWING APPROVED SUBMITTALS FOR EQUIPMENT PROVIDED BY OTHER BUILDING TRADES. 08. THE ENTIRE SET OF PROJECT DRAWINGS HAS INFORMATION PERTAINING TO THE CONSTRUCTION OF THE BUILDING, AND THE ELECTRICAL CONTRACTOR SHALL REVIEW ALL DRAWINGS TO COORDINATE THE INSTALLATION OF ELECTRICAL SYSTEMS. 09. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION OF LIGHTING FIXTURES & EQUIPMENT FURNISHED OR PROVIDED BY OTHERS. EC SHALL TAKE PARTICULAR CARE TO COORDINATE WITH THE FPC, PC, AND THE MC. 10. REFER TO ARCHITECTURAL PLANS & INTERIOR ELEVATIONS TO COORDINATE ALL WALL MOUNTED DEVICES WITH CABINETRY & CASEWORK. ENSURE THAT ALL DEVICE PLATES AND OTHER EQUIPMENT WILL NOT CONFLICT WITH COUNTERTOPS, BACKSPLASHES, WALL TILE, TRIM, ETC. 11. ALL DEVICES MOUNTED ABOVE A COUNTERTOP OR BACKSPLASH SHALL BE INSTALLED AT THE SAME HEIGHT. 12. DEVICES INSTALLED IN BLOCK OR TILED WALLS SHALL BE INSTALLED WITH THE BOX SET ON TOP OF NEAREST COURSE, WITH THE OPENING FOR THE BOX CUT INTO THE COURSE ABOVE. ALL DEVICE BOXES SHALL BE INSTALLED ON TOP OF THE COURSE NEAREST TO THE SCHEDULED MOUNTING HEIGHT. 13. WHERE MULTIPLE DEVICES OF THE SAME VOLTAGE ARE INSTALLED IN CLOSE PROXIMITY, THEY SHALL BE GANGED TOGETHER IN A COMMON BOX AND COVER PLATE. 14. COORDINATE ALL FASTENERS USED WITH WALL, CEILING, AND STRUCTURAL SYSTEMS. EC SHALL TAKE PARTICULAR CARE NOT TO USE FASTENERS IN A METHOD WHICH VIOLATES MANUFACTURER'S INSTALLATION INSTRUCTIONS. GENERAL PROJECT NOTES / SPECIFICATIONS THE LETTER "X" EQUALS THE DEVICE TYPES LISTED BELOW, UNO: BLANK = NORMAL POWER / STANDARD RECEPTACLE IG = NORMAL POWER / ISOLATED GROUND RECEPTACLE TR = NORMAL POWER / TAMPERPROOF RECEPTACLE WP = NORMAL POWER / WEATHER RESISTANT RECEPTACLE WITH WEATHERPROOF IN-USE COVER EM = EMERGENCY POWER / STANDARD RECEPTACLE WITH RED BODY USB = NORMAL POWER / STANDARD RECEPTACLE WITH (2) INTEGRAL USB CHARGING PORTS AND 5V POWER SUPPLY OC = INSTALL AT 8" ABOVE COUNTERTOP HEIGHT - COORDINATE WITH ANY BACKSPLASH OR TILED FINISHES RECEPTACLES / ELECTRICAL DEVICES SIMPLEX RECEPTACLE, WALL MOUNTED. X X DUPLEX RECEPTACLE, WALL MOUNTED SOLID CENTER INDICATES DEDICATED CIRCUIT.X SPLIT WIRED DUPLEX RECEPTACLE, WALL MOUNTED. DOUBLE DUPLEX (QUAD) RECEPTACLES, WALL MOUNTED. SOLID CENTER INDICATES DUAL DEDICATED CIRCUITS. X GFCI RATED RECEPTACLE, WALL MOUNTED SOLID CENTER INDICATES DEDICATED CIRCUIT. X SPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION AS NOTED ON PLANS, WALL MOUNTED. X DESCRIPTIONSYMBOL MOUNTING HEIGHT +18" AFF +18" AFF +18" AFF +18" AFF +18" AFF +18" AFF DUPLEX RECEPTACLE, CEILING MOUNTED. X N/A JUNCTION BOX X SEE PLANS MULTI-SERVICE CEILING OUTLET, CONFIGURATION AS NOTED ON PLANS, CEILING MOUNTED. X N/A FLOOR MOUNTED RECEPTACLE. N/A J JUNCTION BOX WITH FLEXIBLE EQUIPMENT CONNECTION, (6) FEET MAX LENGTH.SEE PLANSJ DOUBLE DUPLEX (QUAD) RECEPTACLES, CEILING MOUNTED.N/A MULTI-SERVICE POWER POLE, CONFIGURATION NOTED ON PLANS.N/A PUSHBUTTON, TYPE AND QUANTITY OF BUTTONS AS NOTED ON PLANS.SEE PLANS X X X TTHERMOSTAT, FURNISHED BY OTHERS UNO. SEE MECHANICAL SCHEDULES FOR DETAILS.+44" AFF SMOKE DETECTOR CEILING X POWER DISTRIBUTION MAIN SWITCHBOARD, MAY BE SWITCHBOARD OR SWITCHGEAR CONSTRUCTION, SEE PLANS FOR DETAILS. FLOOR MOUNTED, FREE STANDING. DASHED LINES REPRESENT CODE REQUIRED CLEARANCES. DESCRIPTIONSYMBOL MSB-A SURFACE MOUNTED DISTRIBUTION PANELBOARD. DASHED LINES REPRESENT CODE REQUIRED CLEARANCES. SURFACE MOUNTED BRANCH PANELBOARD. DASHED LINES REPRESENT CODE REQUIRED CLEARANCES. FLUSH MOUNTED BRANCH PANELBOARD. DASHED LINES REPRESENT CODE REQUIRED CLEARANCES. HV-1 HV-1 T-1 DRY TYPE TRANSFORMER, 15kVA OR LARGER. T DRY TYPE TRANSFORMER, LESS THAN 15kVA. SEE PLANS FOR DETAILS. MGB MAIN GROUNDING BUS. SEE PLANS FOR DETAILS. NF DISCONNECT SWITCH, NON -FUSED. MOUNT AT 48" AFF. DISCONNECT SWITCH, FUSIBLE. FUSE RATING SHOWN. MOUNT AT 48" AFF. COMBINATION MOTOR STARTER / FUSIBLE DISCONNECT. NEMA STARTER SIZE AND FUSE RATING SHOWN. MOUNT AT 48" AFF. 60A N1/60A ELECTRIC MOTOR, NUMBER INDICATES HORSEPOWER. NOT DRAWN TO SCALE.500 25,769 A AVAILABLE BOLTED FAULT CURRENT SF4000N-AL FEEDER TAG, SEE SCHEDULE FOR DETAILS. LIGHTING FIXTURES / DEVICES FIXTURE TYPES AND/OR SWITCHING ARE INDICATED AS LISTED BELOW, UNO: # = FIXTURE TYPE MARK, REFER TO FIXTURE SCHEDULES. NL = "NIGHT LIGHT" FIXTURE, WIRED FOR 24 HOUR OPERATION. a,b = INDICATES SWITCH GROUP WITHIN ROOM OR AREA SHADING INDICATES FIXTURE EITHER CONTAINS AN INTEGRAL BATTERY OPERATED EMERGENCY INVERTER OR IS CONNECTED TO AN EMERGENCY POWER SUPPLY SYSTEM. REFER TO PLANS FOR DETAILS. DESCRIPTIONSYMBOL MOUNTING HEIGHT RECESSED FIXTURE NL # a,b a,b # SURFACE MOUNTED FIXTURE # a,b LINEAR FIXTURE, SUSPENDED. RECESSED DOWNLIGHT. ARROW INDICATES DIRECTION OF WALL WASH LENS, WHERE USED. # a,b # a,b WALL MOUNTED FIXTURES # NL a,b SURFACE MOUNTED STRIP FIXTURES # # # # EMERGENCY EXIT SIGN. SHADING INDICATES FACES USED, ARROWS INDICATE EGRESS PATH. MAY BE CEILING MOUNTED, NOT EXCEEDING +12'-0" AFF. WALL MOUNTED EMERGENCY LIGHTING UNIT SEE SCHEDULES SEE SCHEDULES SEE SCHEDULES SEE SCHEDULES SEE SCHEDULES SEE SCHEDULES +8'-0" AFF +8'-0" AFFEMERGENCY LIGHTING REMOTE HEAD, MOUNT +12" ABOVE DOOR FRAMES OR AS NOTED. WALL = +8'-0" AFF X a THE LETTER "X" EQUALS THE DEVICE TYPES LISTED BELOW, UNO: BLANK = SINGLE POLE TOGGLE SWITCH 2 = DOUBLE POLE TOGGLE SWITCH 3 = THREE WAY TOGGLE SWITCH 4 = FOUR WAY TOGGLE SWITCH M = MOTOR RATED SWITCH LV = DIGITAL LOW VOLTAGE SWITCH D = DIMMING SWITCH T = TIMER SWITCH WP = WEATHERPROOF SWITCH K = KEY OPERATED SWITCH OS = OCCUPANCY SENSOR SWITCH +48" AFF OS a SEE SCHEDULES OCCUPANCY SENSOR, TYPE AS INDICATED IN SCHEDULES. PC a SEE SCHEDULES PHOTOCELL, TYPE AS INDICATED IN SCHEDULES. PP a SEE SCHEDULES LIGHTING CONTROL RELAY, TYPE AS INDICATED IN SCHEDULES. SINGLE-LINE DIAGRAM DESCRIPTIONSYMBOL 400AT 400AF LSI CIRCUIT BREAKER - TRIP RATING / FRAME SIZE, AND/OR NUMBER OF POLES. SETTINGS AND OTHER ACCESSORIES AS NOTED ON PLANS. 400AT 400AF LSIG EB DRAWOUT CIRCUIT BREAKER - TRIP RATING / FRAME SIZE, AND/OR NUMBER OF POLES. SETTINGS AND OTHER ACCESSORIES AS NOTED ON PLANS. TRANSFORMER - VOLTAGE CONFIGURATION, KVA RATING, WIRING CONFIGURATION. SEE PLANS FOR OTHER DETAILS AND REQUIREMENTS. T-1 2,500 kVA 480D-208Y/120V 3000-5 CURRENT TRANSFORMER - RATIO OF PRIMARY TO SECONDARY WINDINGS. 480-120 75 VA POTENTIAL TRANSFORMER - RATIO OF PRIMARY VOLTAGE TO SECONDARY VOLTAGE, HEAT RATING. 1000A BPS DISCONNECT SWITCH - FRAME SIZE. "BPS" INDICATES BOLTED PRESSURE SWITCH. 1000A CLASS J FUSE - TRIP RATING, FUSE CLASS. ELECTRONIC BREAKER OPERATORS: EB = MOTOR OPERATED CLOSE / OPEN GF = GROUND FAULT TRIP UNIT ST = SHUNT TRIP OPEN UV = UNDERVOLTAGE RELEASE 400AT 400AF LSIG GF GROUND CONNECTION N E TRANSFER SWITCH, SEE PLANS FOR TYPE AND OTHER DETAILS. ARC INDICATES CLOSED TRANSITION. SPD SURGE PROTECTIVE DEVICE, SEE PLANS. ELECTRONIC METER, SEE PLANS FOR TYPE. KEYED INTERLOCK, SEE PLANS FOR DETAILS. PROTECTIVE RELAY, SEE PLANS FOR DETAILS. M K1 R1 ELECTRICAL CONNECTION, BOLT / LUG / SCREW. CIRCUITS PHASE CONDUCTORS GROUND CONDUCTOR (IF TWO ARE SHOWN, THE SECOND SHALL BE AN ISOLATED GROUND) NEUTRAL CONDUCTOR DRAWING No. : DRAWN BY : DATE : SCALE : PROJECT No. :PROJECT NAME :DRAWING TITLE :CERTIFIED BY : ORIGINAL DRAWING IS : 24"x36" DEEM MECHANICAL & ELECTRICAL, LLC. RESERVES THE RIGHT TO REVISE THE DESIGN OF THE ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDING THE CHANGES MEET THE DESIGN/BUILD SPECIFICATIONS FOR THIS PROJECT.6831 East 32nd Street, Suite 200Indianapolis, IN 46226Office: 317.860.2990Fax: 317.860.2964www.deemfirst.com A Mechanical and Electrical Company THIS DRAWING AND ALL INFORMATION ONIT IS THE PROPERTY OF DEEMMECHANICAL & ELECTRICAL, LLC. IT ISCONFIDENTIAL AND IT'S SUBMISSION ORDISTRIBUTION TO MEET OFFICIAL REGULATORYREQUIREMENTS, OR FOR OTHER PURPOSES INCONNECTION WITH THIS PROJECT, IS NOT TO BECONSTRUED AS PUBLICATION IN DEROGATION OFDEEM MECHANICAL & ELECTRICAL, LLC., COMMONLAW COPYRIGHT, OR OTHER RESERVED RIGHTS.NEITHER THIS DRAWING NOR ANY PART OF IT MAYBE REPRODUCED, COPIED, EXHIBITED, ORDISTRIBUTED TO OTHERS, NOR MAY ANY ARTICLEOR ITEM BE FABRICATED OR ASSEMBLED FROMTHIS DRAWING, WITHOUT WRITTEN CONSENTFROM DEEM MECHANICAL & ELECTRICAL, LLC.A 1 B C D A B C D 2 3 4 5 1 2 3 4 5 1/8" = 1'-0"8/19/2019 9:42:03 AMAuthor 05/28/2019 19015 10209 DITCH ROAD,CARMEL INDIANASYMBOLS & ABBREVIATIONS BHARAT PATEL HOUSEE-01 ELECTRICAL SHEET INDEX-D SHEET No. SHEET NAME REV No. REV DATE E-01 SYMBOLS & ABBREVIATIONS E-10 SITE ELECTRICAL PLAN E-20 LOWER LEVEL POWER PLAN E-21 CLERESTORY POWER PLAN E-23 UPPER LEVEL POWER PLAN E-24 UPPER ROOF POWER PLAN E-30 LOWER LEVEL LIGHTING PLAN E-31 CLERESTORY LIGHTING PLAN E-32 MAIN LEVEL LIGHTING PLAN E-33 UPPER LEVEL LIHTING PLAN E-50 ONE LINE DIAGRAM E-60 PANEL SCHEDULE REVISION SCHEDULENo. DESCRIPTION DATE08/23/19 David Rutti GYM 008 POW. 010 CHANGE 012 STEAM RM 013 MECH / STORAGE 015 COVERED PATIO 005 PARTY LOUNGE 006 BAR 007 MECH / WATER 016 STEAM MECH 014 BATH 002A BEDROOM 002 BEDROOM 001 MECH. 003 HALL 004 ELEV MECH 009 BATH 001A CLOSET 001B CLOSET 002B HALL 011TVTVTV WP WP WP 3 3 ELEVATOR CONTROLLER ELEVATOR CAB LIGHTS INSTALLED IN ELEV. PIT 200A PANEL 200A PANELS BREAKER DISCONNECT LOCATION DRAWING No. : DRAWN BY : DATE : SCALE : PROJECT No. :PROJECT NAME :DRAWING TITLE :CERTIFIED BY : ORIGINAL DRAWING IS : 24"x36" DEEM MECHANICAL & ELECTRICAL, LLC. RESERVES THE RIGHT TO REVISE THE DESIGN OF THE ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDING THE CHANGES MEET THE DESIGN/BUILD SPECIFICATIONS FOR THIS PROJECT.6831 East 32nd Street, Suite 200Indianapolis, IN 46226Office: 317.860.2990Fax: 317.860.2964www.deemfirst.com A Mechanical and Electrical Company THIS DRAWING AND ALL INFORMATION ONIT IS THE PROPERTY OF DEEMMECHANICAL & ELECTRICAL, LLC. IT ISCONFIDENTIAL AND IT'S SUBMISSION ORDISTRIBUTION TO MEET OFFICIAL REGULATORYREQUIREMENTS, OR FOR OTHER PURPOSES INCONNECTION WITH THIS PROJECT, IS NOT TO BECONSTRUED AS PUBLICATION IN DEROGATION OFDEEM MECHANICAL & ELECTRICAL, LLC., COMMONLAW COPYRIGHT, OR OTHER RESERVED RIGHTS.NEITHER THIS DRAWING NOR ANY PART OF IT MAYBE REPRODUCED, COPIED, EXHIBITED, ORDISTRIBUTED TO OTHERS, NOR MAY ANY ARTICLEOR ITEM BE FABRICATED OR ASSEMBLED FROMTHIS DRAWING, WITHOUT WRITTEN CONSENTFROM DEEM MECHANICAL & ELECTRICAL, LLC.A 1 B C D A B C D 2 3 4 5 1 2 3 4 5 1/8" = 1'-0"8/19/2019 9:42:03 AMWV 05/28/2019 19015 10209 DITCH ROAD,CARMEL INDIANALOWER LEVEL POWER PLANBHARAT PATEL HOUSEE-20REVISION SCHEDULENo. DESCRIPTION DATE1/8" = 1'-0" 1 LOWER LEVEL POWER PLAN 200A, 120V/240V,1P PANELBOARD UTILITY METERING CABINET UTILITY FEED (4) 3/0, (1)#6G, 4"C. ONE LINE DIAGRAM 200A BREAKER DISCONNECTS 200A, 120V/240V,1P PANELBOARD 200A, 120V/240V,1P PANELBOARD 08/23/19 David Rutti ENTRY 109 POW. 110 CLOSET 100B TEMPLE 103 MASTER BEDROOM 1 100 MASTER BEDROOM 2 101 LIVING ROOM 104 DINING ROOM 108 KITCHEN 112 PANTRY 1 113 LAUNDRY 115 MAIN ROOF PATIO 107 STORAGE 117 PANTRY 2 111 BATH 101A LOUNGE 106 MUDROOM / CLOSET 101B GARAGE 116 BATH 100A HALL 102 HALL 114 MASTER ROOF PATIO 118 BENCH BENCH J 3 3 33 3 3 33 WPWP WP DRAWING No. : DRAWN BY : DATE : SCALE : PROJECT No. :PROJECT NAME :DRAWING TITLE :CERTIFIED BY : ORIGINAL DRAWING IS : 24"x36" DEEM MECHANICAL & ELECTRICAL, LLC. RESERVES THE RIGHT TO REVISE THE DESIGN OF THE ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDING THE CHANGES MEET THE DESIGN/BUILD SPECIFICATIONS FOR THIS PROJECT.6831 East 32nd Street, Suite 200Indianapolis, IN 46226Office: 317.860.2990Fax: 317.860.2964www.deemfirst.com A Mechanical and Electrical Company THIS DRAWING AND ALL INFORMATION ONIT IS THE PROPERTY OF DEEMMECHANICAL & ELECTRICAL, LLC. IT ISCONFIDENTIAL AND IT'S SUBMISSION ORDISTRIBUTION TO MEET OFFICIAL REGULATORYREQUIREMENTS, OR FOR OTHER PURPOSES INCONNECTION WITH THIS PROJECT, IS NOT TO BECONSTRUED AS PUBLICATION IN DEROGATION OFDEEM MECHANICAL & ELECTRICAL, LLC., COMMONLAW COPYRIGHT, OR OTHER RESERVED RIGHTS.NEITHER THIS DRAWING NOR ANY PART OF IT MAYBE REPRODUCED, COPIED, EXHIBITED, ORDISTRIBUTED TO OTHERS, NOR MAY ANY ARTICLEOR ITEM BE FABRICATED OR ASSEMBLED FROMTHIS DRAWING, WITHOUT WRITTEN CONSENTFROM DEEM MECHANICAL & ELECTRICAL, LLC.A 1 B C D A B C D 2 3 4 5 1 2 3 4 5 1/8" = 1'-0"8/19/2019 9:42:04 AMWV 05/28/2019 19015 10209 DITCH ROAD,CARMEL INDIANAMAIN LEVEL POWER PLANBHARAT PATEL HOUSEE-22REVISION SCHEDULENo. DESCRIPTION DATE1/8" = 1'-0"1 MAIN LEVEL POWER PLAN 08/23/19 David Rutti PARTY ROOM 201 GAME ROOM 202 UPPER ROOF PATIO 209 GUEST ROOF PATIO 208 BEDROOM 206 BEDROOM 207 CLOSET 207A HALL 205 BATH 207B POWDER 204 BAR 203 BATH 206B CLOSET 206A FIREPIT / TABLE TV TVJ WP WP DRAWING No. : DRAWN BY : DATE : SCALE : PROJECT No. :PROJECT NAME :DRAWING TITLE :CERTIFIED BY : ORIGINAL DRAWING IS : 24"x36" DEEM MECHANICAL & ELECTRICAL, LLC. RESERVES THE RIGHT TO REVISE THE DESIGN OF THE ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDING THE CHANGES MEET THE DESIGN/BUILD SPECIFICATIONS FOR THIS PROJECT.6831 East 32nd Street, Suite 200Indianapolis, IN 46226Office: 317.860.2990Fax: 317.860.2964www.deemfirst.com A Mechanical and Electrical Company THIS DRAWING AND ALL INFORMATION ONIT IS THE PROPERTY OF DEEMMECHANICAL & ELECTRICAL, LLC. IT ISCONFIDENTIAL AND IT'S SUBMISSION ORDISTRIBUTION TO MEET OFFICIAL REGULATORYREQUIREMENTS, OR FOR OTHER PURPOSES INCONNECTION WITH THIS PROJECT, IS NOT TO BECONSTRUED AS PUBLICATION IN DEROGATION OFDEEM MECHANICAL & ELECTRICAL, LLC., COMMONLAW COPYRIGHT, OR OTHER RESERVED RIGHTS.NEITHER THIS DRAWING NOR ANY PART OF IT MAYBE REPRODUCED, COPIED, EXHIBITED, ORDISTRIBUTED TO OTHERS, NOR MAY ANY ARTICLEOR ITEM BE FABRICATED OR ASSEMBLED FROMTHIS DRAWING, WITHOUT WRITTEN CONSENTFROM DEEM MECHANICAL & ELECTRICAL, LLC.A 1 B C D A B C D 2 3 4 5 1 2 3 4 5 1/8" = 1'-0"8/19/2019 9:42:04 AMWV 05/28/2019 19015 10209 DITCH ROAD,CARMEL INDIANAUPPER LEVEL POWER PLANBHARAT PATEL HOUSEE-23REVISION SCHEDULENo. DESCRIPTION DATE1/8" = 1'-0"1 UPPER LEVEL POWER PLAN 08/23/19 David Rutti