HomeMy WebLinkAboutA000.3TOP OF FOUNDATION
TOP OF FLOOR
TOP OF PLATE
WINDOW HEAD HGT.
WINDOW HEAD HGT.
TOP OF PLATE
TOP OF FLOOR
\A1;10'-1{\H0.750000x;\S1#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"
METAL ROOF, PER SPEC
8" TRIM, PER SPEC
ROOF SHINGLES, PER SPEC
ROOF SHINGLES, PER SPEC
STONE SILL, PER SPEC
6" FASCIA, PER SPEC
6" CORNER BOARD, PER SPEC
10" FRIEZE, PER SPEC6" FASCIA, PER SPEC
10" FRIEZE, PER SPEC
16" TAPERED COLUMN W/20" STONE BASE, PER SPEC
STONE VENEER, PER SPEC
STONE, PER SPECSTONE, PER SPEC
FYPON BKT14X16X4 OR EQUAL
BOARD & BATTEN SIDING,\PPER SPEC
4:12 3.5:12 3.5:12 6:12
4:126:12
6:12
6:12
SCALE:FRONT ELEVATION1/4" = 1'-0"
126 126
126
123 1/2 123 1/2
TOP OF PLATE
TOP OF FLOOR
\A1;11'-1{\H0.750000x;\S1#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;10'-1{\H0.750000x;\S1#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"
4:12
4:12
6:12
TOP OF FOUNDATION
TOP OF SLABTOP OF FOUNDATIONWINDOW HEAD HT.\A1;8'-6" \A1;3'-4"\A1;6'-7"\A1;8'-6" \A1;3'-4"\A1;6'-7"
SCALE:REAR ELEVATION1/8" = 1'-0"-
126126
126126
6:12
3.5:12
126
126126
124124 123 1/2
SCALE:LEFT ELEVATION1/8" = 1'-0"-
6:126:12
6:12
3.5:12
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
124
126 126126
126126
124
123 1/2
\A1;1'-0"\PTYP.\A1;3'-0"
MIN. 285 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E"
\A1;4'-0"
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION\A1;4'-0"
MIN. ## SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF
\A1;4'-0"
\A1;4'-0"
SCALE:ROOF PLAN1/8" = 1'-0"-
6:126:12
6:12
4:12
3.5:12 6:126:12
6:12
6:12
6:12
6:12
4:12
4:12
4:12
ROOF AREASQ. FT."A"2136
ROOF AREASQ. FT."B"277
ROOF AREASQ. FT."C"144
ROOF AREASQ. FT."D"294 6:12
6:12
6:12
6:12
3.5:12
3.5:12
4:12
PR3G
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 2136 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 2.85 3.56 3.39 47.47 8 0
AT EAVE 4.27 3.56 3.75 52.53 0 54.00
TOTAL (MIN)7.12 7.12 7.14 100.00
3
HIGH -
RIDGE VENT 2.85 3.56 2.77 42.49 3 0 12.00
AT EAVE 4.27 3.56 3.75 57.51 0 54.00
TOTAL (MIN)7.12 7.12 6.52 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "B"SQ FTG 277 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.37 0.46 0.42 43.26 1 0
AT EAVE 0.55 0.46 0.56 56.74 0 8.00
TOTAL (MIN)0.92 0.92 0.98 100.00
3
HIGH -
RIDGE VENT 0.37 0.46 0.50 47.37 0 0 4.00
AT EAVE 0.55 0.46 0.56 52.63 0 8.00
TOTAL (MIN)0.92 0.92 1.06 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "C"SQ FTG 144 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.19 0.24 0.42 46.56 1 0
AT EAVE 0.29 0.24 0.49 53.44 0 7.00
TOTAL (MIN)0.48 0.48 0.91 100.00
3
HIGH -
RIDGE VENT 0.19 0.24 0.38 43.55 0 0 3.00
AT EAVE 0.29 0.24 0.49 56.45 0 7.00
TOTAL (MIN)0.48 0.48 0.86 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "D"SQ FTG 294 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.39 0.49 0.85 63.54 2 0
AT EAVE 0.59 0.49 0.49 36.46 0 7.00
TOTAL (MIN)0.98 0.98 1.33 100.00
3
HIGH -
RIDGE VENT 0.39 0.49 0.50 50.70 0 0 4.00
AT EAVE 0.59 0.49 0.49 49.30 0 7.00
TOTAL (MIN)0.98 0.98 0.99 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
Joel Hampshire08/04/2014
Garage Left
Truman
1702.300.00 CPM
LOT 660
08/14/20191900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLOTTED: August 15, 2019 / Annie Lee / 1702-TRUMAN-IN-WCLY-EL-CR4G.DWG
A3-CR4G
3SB.1Craftsman 4G3 Car GarageFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule12/16/19
Adam Schriner