HomeMy WebLinkAboutD111 Demolition PlanLEGEND
E%ISTING TO BE REMOVED E%ISTING TO REMAIN
------ WALL WALL
______ PARiIAL HEIGHi WALL ----- PARiIAL HEIGHi WALL
� DOORANDFRAME � DOORANDFRAME
-�--r-WINDOW/SIDELIGHi xWINDOW/SIDELIGHi
�i I CNLWGGRIDAND
7_____r TILES, 2'x4'
�i -L -�CHLINGGRIDAND
�__T__r iILES 2'XL'
�JC� SUPPLV AIR DIFFUSERS
r_v
i,�i EXHAUSiFAN
LnJ
�� �� LIGHi FIXiURE
�L __ J� FWORESCENL 2%4'
?'� u�nrFaruRE,
�,1 FwoeesceNr,zxz
rz ���HrF�xr�RE.�A�
�_-_. ���r F�xr�RE.
FLUORESCENi
-ri IJGHTRRTURE,TRACK
z; u�nrFixruae,scoNce
LIGHi FlXiURE
� PENDANi
$ ���HrsW�r�H
t^, Exir ucnr
��
�-� EMERGENCY LIGHi
�������'� ELECiRIC OUiLEi�S�
DAiA OR
�� COMMUNICATION
o�r�Er
NOTE: EkISTINGRXTURESTHATAREREMOVEDCANBEREUSEDIHN
GOOD CONDIiION_
GENERAL NOTES
I_ REFERiOALLDECONSiRIICiIONNOiESONiIiLESHEEiilll_
2 ALLIiEMSBEINGREMOVE�FROMPROJECiAREAAREiOBE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJEQ OR
Bl11LDWG IF POSSIBLE FOR ALL IiEMS DEiERMWED FOR
REMOVAL, REFER iOiHE �ECONSiRUCiION MANAGEMENi
CHECKLIST BROW.
DECONSTRUCTION MANAGEMENT CHECKL
UNIQUETO EACH PROJECT:
CONTAINER:
ITEM BEING z i� z REMARKS
REMOVED w � � w o
¢ Up �U
3 �U Y�
DOORS FRAMES,
DOORHARDWARE
JECORAiIVE LIGHiING �
CARPET TILE
BROADLOOM
VCi ✓
WALLCOVERWG ✓
TYPICAL FOR EACH PROJECT:
COORDINAiE WIiH BUILDING MANAGEMENi FORSiORAGE LOCAiION OF
SEE BELOW FOR CONiACi
CO�MINGLE CONiAINER: SHIPPWG/PACKAGWG, WOOD SIDDS, WOOD iRIM, HVAC COMPONENiS, CEILWG GRID,
MEiAL SiUDS, W IRING/ CONDUIi, AN� OUiLEiS/S W RCHES
WASiECONiAINER: DRVWALLINSULATION,VINVLBASEANDLVT�W%URVVINVLTILE�
CONTACTS:
COORDINAiE PICK UP AND REQUIREMENiS W IiH SUSAN SHAFER 31 ] 33].1950
PLAN NOTES
i
DOt REMOVEE%ISiWGCABWEfRVANDCOIIMERiOP_
D02 REMOVEEXISiINGSINK. NOSERVICESINKSAREBEINGREMOVED.
D03 REMOVE PORTION OF EXISTING DRYWALL/CEILING BULKHEADAS
REQIII RED_ REFER i0 A I21 FOR DEiAILt_
�04 REMOVEAN�SALVAGEEXISiINGPROJECiORSCREENAN�
SYSiEM. COORDINAiE W IiH iHE BUILDING OWNER FOR NEW
LOCATION.
DOS REMOVEEXISiWGSHOWERUNIi.
D06 REMOVEALLEXISiINGACCESSORIESFROMWALLS.PAiCHWALL
AND REPAIR IS REQUIRED FOR NEW FlNISHES TO BE APPLIED.
DO] REMOVEEXISiWGiOILEi/URINALPAiCHWALLANDREPAIRAS
REOUIRED FOR NEW FINISHES i0 BE APPLIED.
DOB SALVAGEEXISTINGMAILBOXESFORRELOCATION.SEEAIIIFOR
MORE DEfAILt_
D09 COOR�INAiE WIiH BUIL�ING MANAGEMENi FOR RELOCAiION
OF EXISTING WATER HEATER.
D10 SALVAGE EQl11PMENi f-0R RELOCAiION IN WESi CORRIDORSEE
Alll.
�11 REMOVEEXISiWGLOCKERS.REiURNiOBUILDWGMANAGEMENi
FOR REUSE OR RECYCLE. REFER i0 il I I SHEEi FOR ADDIiIONAL
WFORMATION.
p�Z REMOVE EXISiWG WALLS IN iH1S LOCAiION AS REQUIRED FOR
NEW CASED OPENING. DESIGN INiENi IS i0 MAXIMIZE OPENING.
REFER TO ARCHITECTURAL PLAN FOR ADDITIONAL W FORMATION.
0
�
�
.� o Y
J
� N b O J
� Q o �
o�
in Z �. .
r ^ y
m J
� .� � .
P Qn 7
LL O c� J
O c
`n O p 3
� � 2
C
iHIS DRA W ING. AND iH E IDEAS.
DESIGNS AND CONCEPiS CONiA W ED
HEREIN. ARE iHE E%CW $NE
IMELLECiUAL PROPERtt OF SCHOii
DESIGN. WC..ANDARENOiiO BE
useo ore reePreoouceo w wHo�e ore
IN PqRi, wliu0ui iuE wRIIIEN
CONSENi OF SCHOII DESIGN.
�
Z �
olj O O
W LL
UQ^
Z ��
W 'v~iN
� Q h .�
wZo�
LL Z �
Z � J —
J
O � �_
� Z J
UWoo
H N �
U. � p Q
"' � Q
z V 30
Q H 0 z
y � —
V W a
Q` � �
/ ~ �
� WC
C
ISSUE
DAiE DESCRIPiION
OS/]]/19 CHECKiEi
06/0]/19 BIDSEi
REVISIONS
MAR DAiE DB DESCRIPiION
� 06.10.19 MS REVI
� 11.04.19 MS REV2
IVQ.
AR107���17
STATE OF
RELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
y\0.v��i �\p;,V`iiY?A�i
\
onrE: 12/16/19
� ARE4 NOT IN CONTR4Q
� ARFA OF WORK
��
PROJECT NUMBER
2018.260
PROJ. MGR DRAWN BY
MS NP
1 ST FLOOR
DECONSTRUCTION
PLAN
D111
DECONSTRUCTION PLAN
0 P' 4' 8' 16'
� � -