HomeMy WebLinkAboutE111 Electrical PlanLEGEND
NEW CONSTRUCTION
� POWEROUTLET,DUPLEX
Jk POWEROUiLEi,
�� Ql1ADRl1PLEX
� JUNCiION BOX
�: CEILWGMOl1MED
iuNcnoNaox
�u BOX,BLANKCOVERPLATE
V BOX,OPEN
P PROVIDEJUNCiION BO%
U ABOVECEILINGFOR
PO W ER POLE
CONNECiION. POWER
POLE BY OiHERS.
FLOOR BOX W IiH PO W ER
�b AND DATA, FLUSH
MOUNiED
FLOOR BOX WIiH
;J�IQ JUNCTION BOXAND
DAiA, FLUSH MOUMED
DAiA/COMMUNICAiION
YJ OUiLEi �PROVIDE BOX
AND PULLSiRWG ONLVJ
DED DEDICAiEDCIRCUIi
GFCI GROUND FAULi QRCUIi
INTERRUPT OUTLEf
+42" HHGHTOFELECTRICAL
OR DAiA DEVICE
EXISTING TO REMAIN
� POWEROUTLET,DUPLEX
� POWEROUiLEi,
Ql1ADRl1PLEX
�J JUNCiION BOX
O CEILWGMOl1MED
iuNcnoNaox
Q BOX,BLANKCOVERPLATE
�o BOX, OPEN
� POWERANDDAiAPOLE
FLOOR BOX WIiH POWER
�b ANDDATA,FLUSH
MOUMED
FLOOR BOX WIiH
QJ IC� JUNCTIONBOXAND
DAiA, FLUSH MOUMED
a DAiA/COMMUNICAiION
OUTLET
GENERAL NOTES
I_ iENANi'S Fl1RNIil1RE VENDOR IS RESPONSIBLE FOR WSiALLAiION OF
FURNIiURE AND FIELD V ERIFICAiION OF ALL CRIiICAL DIMENSIONS.
2. ALLOUTLETSARETOINSTALLEDIS"MIN.AEETOTHECENTEROF
iHE DEVICE PER ADA Gl11DELWES 11NLESS NOiED OiHERWISE ALL
NEW DEVICES AND FACE PLAiES i0 MAiCH EXISiING.
3. REFER TO DOOR SCHEDULE AND COORDINATE W ITH
iENANi/OW NER REGARDWG POWER LOCAiIONS i0
ACCOMMODAiEELECiRIC SiRIKES. CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE iYPICALLY INSiALLED BY iHE
TENANT'S SECURIiV CONTRACTOR AND NOT SPECIFlED BV SDI.
4_ ELECiRICALWORKISLIMIiEDiOADESIGN-BUILDSCOPEANDIS
OUiLINED IN iHESE DRAWINGS. ALL ELECiRICAL WORK IS LIMIiED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHiW G iHAi DO NOi E%CEED iHE CAPACIiV OF iH E
EXISiINGELECiRICALSERVICEINiHEBUILDING. ELECiRICAL
CONiRACiOR IS i0 NOiIFY APPLICABLE PARiIES IF ADDIiIONAL
W ORK IS REQl11RED SO iHAi ADDIiIONAL PLANS CAN BE FlLED AND
MUSi COMPLV W IiH ALL APPLICABLE CODES_
PLAN NOTES
E01 PROVIDEPOWERASREQl11REDFORELECiRICSiRIKEAiDOOR
FOR CARD READER (CARD READER BY iENANi�. COORDINAiE
WIiH iENANi'S SECl1RIiV CONiRACiOR_ SEE DOOR SCHEDl1LE
f-0R MORE DEiAILt_
E02 PROVIDEPOWERANDDAiAFORiENANi'SWALLMOUNiED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACi
LOCAiION WIiH iENANi.
POWER FOR FIiNESS EQUIPMENi IN iHb LOCAiION i0 BE FED
E03 THROUGHCONNECTRAC-ONFLOORWIREWAVSVSTEM.DESIGN
IMENi IS FOR CONNECiRAC SV4EM i0 BE WSiALLED AS CLOSE
i0 WINDOW LWE AS POSSIBLE PROVIDE ALL REQUIRED
ACCESSORIES, TRANSITION PIECES, WALL CONNEQION KITS, ETC.
RNISH i0 BE CLEAR ANODIZED A W MINl1M_ ASSl1ME
� I � 120V/20AMP DEDICAiED OUiLEi FOR EACH PIECE OF
EQUIPMENT. CONFlRM POWER/DATA NEEDS WITH OWNER'S
RiNESS VENDOR_
E04 PROVIDE POWER AS REQUIRED FOR NEW BOIILE FlLLER IN iHIS
LOCATION.
E05 COORDINAiE E%ACi REQl11REMENiS OF RELOCAiED PROJECiOR
SCREEN AND SV4EM WIiH BUILDWG OW NER_
EO] CONFIRMPOWERLOCAiIONSANDCOORDINAiEWIiHBUILDING
MANAGEMENTAND CAMEEN VENDOR FOR VENDING POWER
NEEDS.
E08 PROVIDEPOWERASREQUIREDFORWAiERHEAiER.COORDINAiE
WITH BUILDING MANAGEMENT.
�i
�
�
.� O Y
J
� N b O J
� Q o �
JJ
N Z �
r — n L
m J
�,�M
P Qn 7
LL O c� J
O c ,_ _
`n O p 3
� 0 2
C
rHis oannwiN�. nNo m e ioens.
oesi�Ns nNo coNcePrs coNrnweo
HereeN. nree rHe �cwsive
IMELLECiUAL PROPERtt OF SCHOii
DESIGN. W C.. AND ARE NOi i0 BE
USED OR REPRODUCED IN wHOLE OR
IN PqRi, wIiHOUi iHf wRIIIfN
GONSENi OF SGHOII DESIGN.
�
Z �
� O O
W LL
UQ^
Z ��
W 'v~iN
� Q h .o
w Z o�
� zz
Z � J —
J
O � �_
�/ Z J
UWoo
H N �
. � p Q
U W �Q
z V 30
Q v' o z
V W Z
Q Z Q
` � C
/ — a
� WC
C
ISSUE
DAiE DESCRIPiION
OS/]]/19 CHECKSET
06/0]/19 BIDSEi
REVISIONS
MAR DAiE DB DESCRIPiION
� 06.10.19 MS REVI
� 11.04.19 MS REV2
IVQ.
AR107���17
STATE OF
PROJECT NUMBER
2018.260
PROJ. MGR DRAWN BY
MS NP
1ST FLOOR
ELECTRICAL PLAN
RELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
y\0.v��i �\p;,V`iiY?A�i
\
onrE: 12/16/19
%
■
AREA Nor �N �oNrRA�r
AREA OF WORK
ELECTRICAL PLAN
0 P' 4' 8' 16'
� � —
��
E111