HomeMy WebLinkAboutL100 Life Safety�i
CODE SUMMARY
1 I SCOPEOFWORK
p PREVIOUSUSEOFSPACE
3 OCCUPANCVCLASSIFlCATION
q CHANGEOFOCCUPANCVCLASSB
5 TOTALBUILDINGAREA
5 TOTALPROJECTAREA
� I OCCUPANCVCALCULATIONS
8 NUMBEROFEXIiS
g SPRINKLER SVSTEM �VES/NO�
10 �OiAL AREA OFACCESSORY USES
7 � iOiAL AREA ON iHE FLOOR
�p ACCESSORVAREAEXCEE9S10%
13 FIREWALLS,AND/OROCCUPANCY
SEPARATIONS �IF REQl11RED�
14 ASHRAE90JSlIMMARV
15 Bl11LT BEf-0RE 19]82
ifi Bl11LDWGCONSTRIICTIONTVPE
LEGEND
OFFlCE REMODEL OF PREVIOUSLV BUILi-OUi OFFlCESPACE
B�USWESSf
B�USWESSf
NO
2235] SHFLOOR X 6STORIES = 134J42SF
4,918 SF
SPACETVPE I AREA I SFPEROCCUPANT I OCCUPLOAD
80SWESSAREA 2500SF 100 13
TOTAL OCCUPANTS IN PROJECTAREA
BUSINESSAREA: REOUIRED:I PROVIDEDP4
FIiNESS CENiER: REOUIRED: I PROVIDED: I
CONFERENCE: REOUIRED:2 PROVIDED:2
YES-EXISiINGiO REMAIN
0 SF
22,35] SF
NO
N/A
REQUIREMENiS WILL BE MEi �SEE REFLECiED CEWNG PLAN)
NO
IIC_\
Ep EXISiINGELECiRICALPANELLOCAiION
EX exisriNc exir
�I re FIRE EXiINGUISHER
� exirsicN
--- iRAVELDISiANCE
O NIGHiLIGHi/EMERGENCYLIGHiING
H�i -SEE REFLECiED CEILING PLAN
98
LIFE SAFETY NOTES
I. PROVIDE EMERGENCY LIGHiING IN iENANi SPACE AS REQUIRED PER
NEMAAND IB0. EMERGENCV BATfERV PACKS OR LIGHTS
CONNECiED i0 AN EMERGENCY POW ER SOURCE ARE R EQUIRED IF
iHE SPACE CONiAINS 50 PERSONS OR MORE. FIXiURES SHOW N ON
PLAN ARE FOR REFERENCE ONLY.
2 PROVIDEALARM NOiIFICAiION APPLIANCES �HORNS/SiROBE$�,
EMERGENCY SPEAKERS, SMOKE DEfECTORS, FlR E PULLS, AND ANY
OTH ER R EQUIRED ALARM & DETECTION SVSTEMS AS NECESSARV TO
MEEi ALLAPPLICABLE CODES �INiERNAiIONAL BUILDING CODE,
IMERNAiIONAL RRE CODE, N FPA�_ IN RECEPiION AREAS,
CONFERENCE ROOMS AND OiHER HIGH PROFlLEAREAS WIiHIN SUIiE,
ALL LOCATIONS OFSUCH DEVICES MUST BE APPROVED BYSDI OR
TENANT PRIOR TO I NSTALLATION. FAI W RE TO DO SO MAV R ESULT IN
CONiRACiOR RELOCAiWG iHESE IiEMS Ai iHEIR E%PENSE
3. FIRE EXiINGUISHERS: CONiRACiOR i0 ENSURE ALL NEW AND
EXISTING FlRE EXrINGUISH ERS ARE INSTALLED ACCOR DING TO NFPA
10- COORDINAiE WIiH OWNER/LANDLORD ON E%iWGUISHER iVPE
AND HOUSING. MAXIMUM iRAVEL DISiANCE OF J5 FEEf FROM ANY
POINT TO A VISIBLE EXTINGUISH ER.
iHE f-0LLOW WG NOiES APPLV ONLV W E%ISiWG SPRW KLERED FACILIiIES_
d. FIRE PROiECiION WORK IS i0 BE PROVIDED BY DESIGN/BUILD
SERVICESUNDERiHEGENERALCONiRACi. PROVIDEACOMPLEiE
WORKWGSVSiEM_ SCHOii DESIGN, INC_ IS NOi RESPONSIBLE FOR
iHE DESIGN, WSiALUiION, OR RENOVAiION OF iHE FlRE SPRWKLER
SYSiEM.
5. THE FlRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIR ED
DRAW WGS. AND SHALL FlLEiHOSE DRAW WGS. AND REUiED
GENERAL NOTES
LI. REFER i0 ARCHIiECiURAL PLAN FOR WALL iYPEAND CONSiRUQION
DETAILS.
L2_ E%ISiWG E%li SIGNS FlRE PULLS, FRE E%iWGUISHERS. AURM
NOTIFlCATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS FlR E PULLS, FlRE EXTINGUISHERS AND ALARM NOTIFlCATIONS AS
REQl11RED i0 MEH ALL LOCAL AND SiAiE CODES_
c
�
•� o
� � J
� N b � J
� Q o �
JJ
�nZ� .—
L — I� y
� J
a Q _ 'o
� O c+� j
O c
� O p 2
� 2
C
rHis orenwiNc. nNo m E ioEns.
oesi�Ns nNo coNcePrs coNrnweo
HereeN. nree rHe Excwsive
IMELLECiUAL PROPERtt OF SCHOii
�ESIGN. WC..AN�ARENOiiO BE
useo ore reePreoouceo w wHo�e ore
iN PnRr, wirHOUr rHE wRinEN
CONSENi OF SCHOII DESIGN.
�
O
Z
� O O
W `L
UQ^
Z � o
W 'v~iN
� Qh�
W Z O�
I,L W Z Z
Z � J —
J
O � �_
�/ Z J
UWoo
H N �
. � p Q
U "' � Q
z V 30
Q v� o z
U w z
Q Z a
' � c
_ �
� WC
C
ISSUE
DAiE DESCRIPiION
OS/2]/19 CHECKSEi
06/0]/19 BIDSEi
REVISIONS
MAR DAiE DB DESCRIPiION
� 06.10.19 MS REVI
� 11.04.19 MS REV2
IVQ.
AR107���17
STATE OF
PROJECT NUMBER
2018.260
PROJ. MGR DRAWN BY
MS NP
1ST FLOOR
LIFE SAFETY
RELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
y\0.v��i �\p;,V`iiY?A�i
\
onrE: 12/16/19
1�
��
� � o0
❑ AREAOFWORK `�