HomeMy WebLinkAboutLifeSafety_G001RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `� s��� �\o,v�N�n� � \ onrE: 12/17/19 ROOM SCHEDULE NUMBER NAME Area 101 BOA 377 SF 102 FA OFFICE 170 SF 104 EQUIP. SUPP. 165 SF 106 OPEN 225 SF 107 OPEN 132 SF 1 LIFE SAFETY PLAN SCALE: 3/16" =1'-0" �A 1 � � N L MITSCH D E S I G N 200 S. Rangeline Rtl.l Suite 226 Carmel, intliana a6032 31]5]32222 www. m i[schtlesign.com I�'1 �1 W � 0 W � O w � � 0 � LL � � w � Z � � w � � � � w w � � N � a l9 LJJ Q �t Z�a O>z n�Q Oz° � w Z Q a J 3Zw � W N V �JPR�s RR�Y UJ:; P Fo � :: m- � AR00034184 i� - 9� iP °G'� % ✓! ..,ET i rn h .- ¢ II U W m O z a 3 a � K � � z O H ��� w� ��� ww ��# � � M U � z o' N j W W Q Q W W � O Z�N �Z� — WUd' � KKW aan ,�Smk��,�,�w�k�oF wa nxeo iH a.aHee�e MeowM or exa Aessiorv� u�NoicArEo oa �aEse+rm e. r�ESE oaAwwcs w�o PeR.rar Mi.scn Risn.saEseavme arron�sEs � ExraEss�.>wmrtrEowv+anwc LIFE SAFETY PLAN & CODE INFORMATION �00� LIFE SAFETY LEGEND NOT IN CONTRACT, IF APPLICABLE FE �--�—I--� RECESSED CABINET OR WALL MOUNTED FIRE EXTINGUISHER � DENOTESDIRECTIONOFEGRESSTOEXIT/EXITDISCHARGE � DENOTES 1-HR RATED WALL DENOTES2HR RATED WALL NOTE: COORDINATE FINAL FIRE EXTMGUISHER LOCATIONS W ITH LOCAL FIRE CHIEF AS REQUIRED. NOTE REFER TO RERECTED CEILING PLAN AND OR ELECTRICAL ENGMEER DRAWINGS FORALL EMERGENCV AND EXIT LIGHT LOCATIONS. CODE ANALYSIS DESCRIPTION RENOVATION PROPOSED USE OF FACILITY B BUILDINGCONSTRUCTIONTVPE II-B(TABLE601) OCCUPANCVCLASSIFICATION(S) 6(SECT302) OCCUPANCV SEPERATIONS REQUIRED NOT REQUIRED (TABLE 508.4) TOTAL OCCUPANTS PER LOAD FACTORS 1100 SF / 100 SF PER OCC FACTOR = 11 OCG (TABLE 1004.1 2) AUTOMATICSPRINKLERSVSTEM FULL PORTABLEFlREEXTINGUISHERS MAXTRAVELDISTANCETOEXTINGUISHER=15(TABLE906.3) COMMON PATH OF EGRESSTRAVEL 100 FEET (TABLE 1014_3) EXITACCESSTRAVELDISTANCE 300FEET�TABLE10162) CORRIDOR FIRE-RESISTANCE RATMG NOT REQUIRED (TABLE 1018.1) ENCLOSEDEXITACCESSSTAIR NOTREQUIRED(SECT1009) DEAD END CORRIDOR MAX 50 FEET (SECT 10184) MINCORRIDORWIDTH 441NCHES(TABLE10182) MIN/MAXDOORWIDTH 3Z481NCHES(SECT1008.1.1) DOORS EGRESS DOOR MUST SW ING TOW ARDS EGRESS W HEN SERVING SOOR MORE OCCUPANTS. MANUALLV OPERATED SLIDMG DOORS ONLV PERMITTED FROM OCC LOAD SPACES OF 10 OR LESS. (SECT 1008.12) PANIGFlRE EXIT HARDWARE IS ONLV REQUIRED WHEN SERVING SOOR MORE OCCUPANTS. (SECT 1008.1.10) EXITS F2EQUIF2EDIPF20VIDED � I 1(SECT 1015) APPLICABLE BUILDINC CODES CODE DESCRIPTION COMPRISEDOF GENERALADMINISTRATIONRULES GENERALADMINISTRATIONRULES "615WC12 (ENTIRE DOCUMENT) (GAR) (UPDATED 08.012014) (AMENDED 1201 2014) BUILDINGCODE 20141NDIANABUILDINGCODE '20121NTERNATIONAL QNDIANAAMENDMENTS) QBC)-EFFECTIVE12012014 BUILDINGCODE ' 6�5 IAC 13-2.6 FlRECODE 20141NDIANAFlRECODEQFC)- '2012MTERNATIONALFlRECODE QNDIANAAMENDMENTS) EFFECTIVE 12.012014 ' 8�5 WC 22-2.5 PLUMBING CODE 20121NDIANA PLUMBING CODE ' 20061NTERNATIONAL PLUMBING QNDIANAAMENDMENTS) QPC)-EFFECTIVE12242012 CODE " 815 IAC � &�.4 ELECTRICALCODE 20091NDIANAELECTRICAL "2008NFPA10 QNDIANAAMENDMENTS) CODE(IEC)-EFFECTIVE08262009 "6]SIAC1]-iB MECHANICALCODE 20141NDIANAMECHANICAL '20121NTERNATIONAL QNDIANAAMENDMENTS) CODEQMC)-EFFECTIVE12.012014 MECHANICALCODE LL s�s wc i e-i.s HANDICAP ACCESSIBILITV CODE 20141NDIANA BUILDMG CODE ' 6�5 WC 13-2.6-12 CHAPTER 11 (INDIANAAMENDMENTS) CHAPTERII-ACCESSIBILITV 'A111.1ACCESSIBLEANDUSABLE BUILDINGS AND FACILITIES, 2009 EDITION ENERGVCODE 20101NDIANAENERGV 'ASHRAE90.1200] QNDIANAAMENDMENTS) CONSERVATION CODE QECC) - ' 6�5 �AC 19.3 EFFECTNE 05.012010 ELEVATORSAFETYCODE 20111NDIANAELEVATORSAFETY '6�SIAC21,'ANSVASMEA1].1200�, CODEQESC)(UPDATED 'ANSI/ASMEA90.1,2003,' 09282011) ANSIIA10.4,2004,"ASMEIA18.1,2005, "A1L3,2005, "ASME QEI-1,200�