HomeMy WebLinkAboutP3.0ROUiE COMBWED SANITARY DRAIN LWE
TO WALL RWTE VENT UP, AND
SANITARY DOWN AS SHOWN ON PL4N5.
ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FlELD
CONDITIONS OR MEET LOCAL CODE REQUIREMEMS. HUBLESS CAST IRON
PIPE, FlTTINGS AND CONNECTORS ALL AROUND SINK AND TRAP.
CONNECT TRAP FROM CEMER COMPARTMENT.
3-COMP. SINK DETIAL
NOT TO SCALE
PROVIDE CLEANOl1T5 IN
TURNS/ENDS OF PIPE.
DWV FITfINGS IF 9ZE
IS LARGER THAN 1"
'�/ Sl1FFlCIENT TO REMOVE GRATE
SLOPE PIPE 0 V AN� 4RAINER. MINIMIIM
AS Ml1CH AS � GAP = 1W0 PIPE DIAMEfERS
POSSIBLE �
TOWARD �
DISCHARGE � I
MAKE CONNEC?ION
t0 EQUIPMENi
AS REpUIRED
TRAP AND VENT IF
MAKE PIPE MINIMUM ONE 9ZE REpUIRE� FOR THE
LARGER iHAN E�UIPMENi WN- LENGTH OF DRAIN PIPE
NECTION, MINIMUM 3/4'. INSTALLED
ROl1TE PIPE WCONSPICUOUSLY AND UNOBTRUSNELY. HANG
PIPE AS REQl11RED. DO NOT INSULATE INDIRECT DRAIN PIPE
EXCEPi M FREEZER.
INDIRECT DRAIN DETAIL
NOT TO SCALE
co�o wnhe suac�r
i0 WAiER HEAiER
traicn� en��
WATER HEATER SHALL BE
INSTALLE� WITH HEAT TRAPS.
iHERMOSTAPC MI%ING VALVE. 1MV-1
SET AT 110' MA%.
I
O y 110' HOT WATER
SUPPLY ID FlXNRES
I i1PICAL h1ERMOMEiER
�
140' HOT WATER
� SUPPLY 70 DISHWASHER
I
TWICAL �IELECiRIC
uwary
� ASME RAiE� IEMPERARIRE AN�
PRESSURE RELIEF VALVE.
wH-t
�WAiER HEAiER �RAIN VALVE
PLAIFORM
WATER HEATER PIPING DETAIL
NOT TO SCALE
RELEASED FOR CONSTRl1CTI0N
Su6jec��o compliance with allregula�ions
04 S�a�e antl Local Codes
City of Carmel
`�sv���\o,�r�nlfl
SHOT — OFF VALVE
1FRP PFIMER VALVE
1/2"
�ISIRIBOiION llNli(57 h5 REQl11RE�
FOR SEflVING MUL1fPLE iRAPS
ro o�rvER r�oaR ow,iNs
(wnEreE naPucae�E)
CEILING OR
UNDER COUMER
1/Y SOR COPPER
PRIMER LINES
(caNcraico)
ROOR
ROOR DflAIN
i0 SEWER
TRAP PRIMER DETAIL
NOT TO SCALE
NICKEL BRONZE
TRACTOR GRF
B»]dNiQ».Ild[N.9
AWMINUM DOM.
STRAINER
FLOOR SINK DETAIL
NOT TO SCALE
BRASS CLEANOUT PWG�
WIiH COONiERSONK HEAU \
. d. °. . ° $ . .
C.I. WASTE
LENGiH t0
i�R00R
CONCREfE SUB
I/B C.I. BENO
FlNISH FLOOR
11RED— BUT NOT SHOWN
JF INSTLLATION DETAIL
PROVIDE CLEANOUT TEE WITH—
WONrERSIINK ABS PIASiIC
PWG: TAPERED—THREA� WITH
ifE JOINi COMPOUN�
A ROON� 19 GAOGE StAINLE55 4EEL
COVER WITH BEVELE� EDGES ANO
GIAiHEAD MACHWE SCREW
FlNISHED
I �
I I COWMN OR PARTION AS
I I SHOWN ON FLOOR PIAN
I CLEANOIIt PACE SHALL BE
WRHIN 4" OF WALL SURFACE.
PROVIDE PIPE EXTENSION, IG
I I reEouiRco.
I I
I � �
a 8
corvcarrE sueJ I
SANITARY PIPE SANITARV PIPE
DIRECTION Oi FLOW VB aENo, IF CLEANOIIt �IRECTION OF PLOW
OCCURS AT ENO OF PIPE
FLOOR CLEANOUT WALL CLEANOUT
�
L LOCATE AT BUIL�ING E%IT. AT ENDS OF RUNS. AT TURNS OF PIPE
creentere tHnry as oecree[s, ar so' irvterevn�s ary stanmHt reuHs, arvo
WHERE SHOWN ON PUJJS. PRONDE BACKFlLL PER ARCHRECTURAL
SPEQFlCATIONS LOCATE CLEANOUTS WHERE THERE IS 18" CLEPR
AROUN�. CONSULi LOCAL CO�ES FOR OiHER FCO REOUIREMENiS.
2 FLOOR CLEANOOtS NOi ID BE LOCAtE� IN CARPEfE� AREAS.
3. PROVIDE WALL CLEANOUTS (WCO) WHERE SHOWN ON PIAN AN� ON
sr.Nrtnav eRncHEs Nor sERVEo er n F�aoa c�Eallour: �ocnrEo
neave Fia�uee aaao eiu withiry a^ aF aaore. corvsu�t �ocn�
caocs rore otHCR wca recouireEMcrrts.
SANITARY CLEANOUT DETAILS
NOT TO SCALE
io'—o"
CEARANCE FROM INTAKES
FOR PIPE SLOPE—
PROVIDE COPPER
OR NON—MEfALLIC
COATING WHERE
HANGERS COMACT
6ARE COPPER PIPE
VENT PIPE THRU ROOF DETAIL
NOT TO SCALE
w000
TOP BEAM C-CUMF
IF STEEL 6AR JOIST
ADJUSTABLE BAND HANGER
FOl1R INCH OR LESS PIPES
CLEVIS HANGER FOR
PIPE OVER FOUR INCH
�O NOt HANG PIPE PROVIDE GALVANRED SiEEL SADDLE FOR ALL
URGER THAN b" FROM INSULATE� PIPE LARGER THAN b/4". VERIFY
60TTOM OF JOISTS. INSULATION THICKNESS WHEN SIZING HANGERS.
�llE TO CHANGES IN WATER VELOCITV. PROVI�E SEISMIC BRACING I
REpUIRED BY LOCAL AUTHORITIES CHAINS OR PERFORATED STRAP
OR STEEL IS NOT ACCEPTABLE REFER W CODES FOR FURTHER
��FORMPIPE SUPPORT DETAIL
NOT TO SCALE
FlNISH
DECK
FLOOR
�' • '� �CONCREfE FlLL
� WATERPROOF MEMBRANE
. • 7-0" BEYOND DRAIN
o- SIAB
6
� � •}.
1I2AP RE�UIRED- 6Ut NOi SHOWN
AS PNRT OF INSTLLATION DETAIL
FLOOR DRAIN DETAIL
NOT TO SCALE
No.
,�4�3982
S��-,r-a
_XGIV--RNG
is33 Ensr NORrHriE�o oarvE
suite aoo
BROWN56lIRG IN 46112
WWVI.SPENCERMEP.COM
- ARCIIITCCTUR
298 south lOth street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
studio@petersonarch itecture.com
naf
c naf
MIDDLE EASTERN GRILL
Z
W
i
W`
/
O
�
�C
L
�
Z
Z
W
�
J
�
Z
�
WL
1
�
Q
W
W
J
�
0
L
�
Q
Z
�
Q
Z
w
¢
�
N N
¢ �
0
z �
¢
�Q
r=
Ul Q
=o
w=
a_
x w
� �
K �.
O ¢
� U
r
N
PERMIT SET
DECEMBER 3, 2019
REVISIOpNEyS�:S
1� DpAIE ION
QOEVISIOPI
AlE
0 �p����
Q OEVISIOPI
pAEylE�5
5� DAIE ION
DRAINJ BY: SiAFF
CHECKED BY: M CokoRAY
PROJECT NUMBER: 19-0139
PLUMBING
DETAILS
P��O
ncg nuwxa ua aw� x caxrmia
.wo sw� a usn air x wxsuwt m nc
nc�r rnx
PEiERSON ARCHITECiURE, P.C.
MO O11ER IH qt WPIlG1XW WY 9E W➢E
■mwr nc raaa wirtn casHr a
PElER50N ARCHITECIURE, P.C.
,uL onEx cromaart wo cara uw
au�ts x� �wr �[mcuir �+�m.
onrE: 12/18/19
ROOF PENEfRATI0N5 ONLY 9Y WJOLOR�
CONiRACTOR. ONLY BUTI£R APPROVEO
MATERIAL ID 9E WE�
THREE COMPARTMENT SINK