HomeMy WebLinkAboutP3.0ROUiE COMBWED SANITARY DRAIN LWE TO WALL RWTE VENT UP, AND SANITARY DOWN AS SHOWN ON PL4N5. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FlELD CONDITIONS OR MEET LOCAL CODE REQUIREMEMS. HUBLESS CAST IRON PIPE, FlTTINGS AND CONNECTORS ALL AROUND SINK AND TRAP. CONNECT TRAP FROM CEMER COMPARTMENT. 3-COMP. SINK DETIAL NOT TO SCALE PROVIDE CLEANOl1T5 IN TURNS/ENDS OF PIPE. DWV FITfINGS IF 9ZE IS LARGER THAN 1" '�/ Sl1FFlCIENT TO REMOVE GRATE SLOPE PIPE 0 V AN� 4RAINER. MINIMIIM AS Ml1CH AS � GAP = 1W0 PIPE DIAMEfERS POSSIBLE � TOWARD � DISCHARGE � I MAKE CONNEC?ION t0 EQUIPMENi AS REpUIRED TRAP AND VENT IF MAKE PIPE MINIMUM ONE 9ZE REpUIRE� FOR THE LARGER iHAN E�UIPMENi WN- LENGTH OF DRAIN PIPE NECTION, MINIMUM 3/4'. INSTALLED ROl1TE PIPE WCONSPICUOUSLY AND UNOBTRUSNELY. HANG PIPE AS REQl11RED. DO NOT INSULATE INDIRECT DRAIN PIPE EXCEPi M FREEZER. INDIRECT DRAIN DETAIL NOT TO SCALE co�o wnhe suac�r i0 WAiER HEAiER traicn� en�� WATER HEATER SHALL BE INSTALLE� WITH HEAT TRAPS. iHERMOSTAPC MI%ING VALVE. 1MV-1 SET AT 110' MA%. I O y 110' HOT WATER SUPPLY ID FlXNRES I i1PICAL h1ERMOMEiER � 140' HOT WATER � SUPPLY 70 DISHWASHER I TWICAL �IELECiRIC uwary � ASME RAiE� IEMPERARIRE AN� PRESSURE RELIEF VALVE. wH-t �WAiER HEAiER �RAIN VALVE PLAIFORM WATER HEATER PIPING DETAIL NOT TO SCALE RELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions 04 S�a�e antl Local Codes City of Carmel `�sv���\o,�r�nlfl SHOT — OFF VALVE 1FRP PFIMER VALVE 1/2" �ISIRIBOiION llNli(57 h5 REQl11RE� FOR SEflVING MUL1fPLE iRAPS ro o�rvER r�oaR ow,iNs (wnEreE naPucae�E) CEILING OR UNDER COUMER 1/Y SOR COPPER PRIMER LINES (caNcraico) ROOR ROOR DflAIN i0 SEWER TRAP PRIMER DETAIL NOT TO SCALE NICKEL BRONZE TRACTOR GRF B»]dNiQ».Ild[N.9 AWMINUM DOM. STRAINER FLOOR SINK DETAIL NOT TO SCALE BRASS CLEANOUT PWG� WIiH COONiERSONK HEAU \ . d. °. . ° $ . . C.I. WASTE LENGiH t0 i�R00R CONCREfE SUB I/B C.I. BENO FlNISH FLOOR 11RED— BUT NOT SHOWN JF INSTLLATION DETAIL PROVIDE CLEANOUT TEE WITH— WONrERSIINK ABS PIASiIC PWG: TAPERED—THREA� WITH ifE JOINi COMPOUN� A ROON� 19 GAOGE StAINLE55 4EEL COVER WITH BEVELE� EDGES ANO GIAiHEAD MACHWE SCREW FlNISHED I � I I COWMN OR PARTION AS I I SHOWN ON FLOOR PIAN I CLEANOIIt PACE SHALL BE WRHIN 4" OF WALL SURFACE. PROVIDE PIPE EXTENSION, IG I I reEouiRco. I I I � � a 8 corvcarrE sueJ I SANITARY PIPE SANITARV PIPE DIRECTION Oi FLOW VB aENo, IF CLEANOIIt �IRECTION OF PLOW OCCURS AT ENO OF PIPE FLOOR CLEANOUT WALL CLEANOUT � L LOCATE AT BUIL�ING E%IT. AT ENDS OF RUNS. AT TURNS OF PIPE creentere tHnry as oecree[s, ar so' irvterevn�s ary stanmHt reuHs, arvo WHERE SHOWN ON PUJJS. PRONDE BACKFlLL PER ARCHRECTURAL SPEQFlCATIONS LOCATE CLEANOUTS WHERE THERE IS 18" CLEPR AROUN�. CONSULi LOCAL CO�ES FOR OiHER FCO REOUIREMENiS. 2 FLOOR CLEANOOtS NOi ID BE LOCAtE� IN CARPEfE� AREAS. 3. PROVIDE WALL CLEANOUTS (WCO) WHERE SHOWN ON PIAN AN� ON sr.Nrtnav eRncHEs Nor sERVEo er n F�aoa c�Eallour: �ocnrEo neave Fia�uee aaao eiu withiry a^ aF aaore. corvsu�t �ocn� caocs rore otHCR wca recouireEMcrrts. SANITARY CLEANOUT DETAILS NOT TO SCALE io'—o" CEARANCE FROM INTAKES FOR PIPE SLOPE— PROVIDE COPPER OR NON—MEfALLIC COATING WHERE HANGERS COMACT 6ARE COPPER PIPE VENT PIPE THRU ROOF DETAIL NOT TO SCALE w000 TOP BEAM C-CUMF IF STEEL 6AR JOIST ADJUSTABLE BAND HANGER FOl1R INCH OR LESS PIPES CLEVIS HANGER FOR PIPE OVER FOUR INCH �O NOt HANG PIPE PROVIDE GALVANRED SiEEL SADDLE FOR ALL URGER THAN b" FROM INSULATE� PIPE LARGER THAN b/4". VERIFY 60TTOM OF JOISTS. INSULATION THICKNESS WHEN SIZING HANGERS. �llE TO CHANGES IN WATER VELOCITV. PROVI�E SEISMIC BRACING I REpUIRED BY LOCAL AUTHORITIES CHAINS OR PERFORATED STRAP OR STEEL IS NOT ACCEPTABLE REFER W CODES FOR FURTHER ��FORMPIPE SUPPORT DETAIL NOT TO SCALE FlNISH DECK FLOOR �' • '� �CONCREfE FlLL � WATERPROOF MEMBRANE . • 7-0" BEYOND DRAIN o- SIAB 6 � � •}. 1I2AP RE�UIRED- 6Ut NOi SHOWN AS PNRT OF INSTLLATION DETAIL FLOOR DRAIN DETAIL NOT TO SCALE No. ,�4�3982 S��-,r-a _XGIV--RNG is33 Ensr NORrHriE�o oarvE suite aoo BROWN56lIRG IN 46112 WWVI.SPENCERMEP.COM - ARCIIITCCTUR 298 south lOth street suite 500 noblesville in 46060 p 317.770.9714 f 317.770.9718 studio@petersonarch itecture.com naf c naf MIDDLE EASTERN GRILL Z W i W` / O � �C L � Z Z W � J � Z � WL 1 � Q W W J � 0 L � Q Z � Q Z w ¢ � N N ¢ � 0 z � ¢ �Q r= Ul Q =o w= a_ x w � � K �. O ¢ � U r N PERMIT SET DECEMBER 3, 2019 REVISIOpNEyS�:S 1� DpAIE ION QOEVISIOPI AlE 0 �p���� Q OEVISIOPI pAEylE�5 5� DAIE ION DRAINJ BY: SiAFF CHECKED BY: M CokoRAY PROJECT NUMBER: 19-0139 PLUMBING DETAILS P��O ncg nuwxa ua aw� x caxrmia .wo sw� a usn air x wxsuwt m nc nc�r rnx PEiERSON ARCHITECiURE, P.C. MO O11ER IH qt WPIlG1XW WY 9E W➢E ■mwr nc raaa wirtn casHr a PElER50N ARCHITECIURE, P.C. ,uL onEx cromaart wo cara uw au�ts x� �wr �[mcuir �+�m. onrE: 12/18/19 ROOF PENEfRATI0N5 ONLY 9Y WJOLOR� CONiRACTOR. ONLY BUTI£R APPROVEO MATERIAL ID 9E WE� THREE COMPARTMENT SINK