WOOD ROOF TRUSSES
1.01 WORKINCLUDED
A. FABRICATE AND SUPPLY WOOD TRUSSES AS SHOWN ON THE
DRAWINGS AND AS SPECIFlED. WORK TO WCLUDE ANCHORAGE,
BLOCKING, CURBING, MISCELLANEOUS FRAMING AND BRACING.
1.02 DEFINITIONS
A. TRUSS: THE TERMS "TRUSS" AND "WOOD TRUSS COMPONENT"
REFER TO OPEN WEB LOAD CARRYING ASSEMBLIES SUITABLE
FOR SUPPORT OF ROOF DECKS OR FLOORS IN BUILDINGS.
B.MANUFACTURER:A MANUFACTURER WHOIS REGULARLY
ENGAGED IN DESIGN AND FABRICATION OF WOOD TRUSS
COMPONENTS.
C. TRUSS INSTALLER: BUILDER, CONTRACTOR OR SUB-
CONTRACTOR WHO IS RESPONSIBLE FOR THE FIELD STORAGE,
HANDLING AND INSTALLATION OF TRUSSES.
1.03 TRUSS DESIGN
A. TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THESE
SPEGFICATIONS AND WHERE ANY APPLICABLE DESIGN
FEATURE IS NOT SPECIFIED HEREIN, DESIGN SHALL BE IN
ACCORDANCE WITH APPLICABLE PROVISIONS OF LATEST
EDITION OF NATIONAL DESIGN SPECIFICATION FOR WOOD
CONSTRUCTION (NCD) AMERICAN FOREST AND PAPER
ASSOCIATION (AFPA), AND DESIGN SPECIFICATIONS FOR METAL
PLATE CONNECTED WOOD TRUSSES (ANSIITPI 1), TRUSS PLATE
INSTITUTE (TPI), AND CODE OF JURISDICTION.
B. TEMPORARY BRACING: STRICTLY FOLLOW TPI DSB FOR DESIGN
SPECIFICATIONS FOR TEMPORARY BRACING.
C. HANDLING, INSTALLING AND BRACING: STRICTLY FOLLOW TPI
HIB COMMENTARY AND RECOMMENDATIONS.
D. MANUFACTURER SHALL FURNISH DESIGN DRAWINGS BEARING
SEAL AND REGISTRATION NUMBER OF A CIVIL OR STRUCTURAL
ENGINEER LICENSED IN THE STATE OF INDIANA. DRAWINGS
SHALL BE APPROVED BY ARCHITECT PRIOR TO FABRICATION.
E. TRUSS DESIGN DRAWINGS SHALL INCLUDE AS MINIMUM
INFORMATION:
1. SPAN, DEPTH OR SLOPE AND SPACING OF
TRUSSES;
2. REQUIRED BEARING WIDTH;
3. DESIGN LOADS AS APPLICABLE, TO MEET ALL
CURRENT INDIANA CODES;
4. ADJUSTMENT TO WMBER AND PLATE DESIGN
RELEASED FOR CONSTRl1CTI0N LOADS FOR CONDITION OF USE;
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
`�j sv�� �\'��v�N�nl.� �
�
onrE: 12/18/19
5. REACTIVE FORCES, THEIR POINTS OF
OCCURRENCE AND DIRECTION;
6. PLATE TYPE, GAGE, SIZE AND LOCATION OF PLATE
AT EACH JOINT;
7. LUMBER SIZE, SPECIES AND GRADE FOR EACH
MEMBER;
8 LOCATION OF ANY REQUIRED CONTINUOUS LATER
BRACING;
9. CALCULATED DEFLECTION RATIO AND/OR
MAXIMUM DERECTION FOR LIVE AND TOTAL LOAD;
10. MAXIMUM AXIAL COMPRESSIVE FORCES IN TRUSS
MEMBERS;
1 L LOCATION OF JOINTS;
12. CONNECTION REQUIREMENTS FOR:
a. TRUSS TO TRUSS GIRDERS;
b. TRUSS PLY TO PLY; AND
c. FIELD SPLICES.
F. PROVIDE METAL PLATE CONNECTED WOOD TRUSSES CAPABLE
OF WITHSTANDING DESIGN LOADS WITHIN LIMITS AND UNDER
CONDITIONS INDICATED.
a. DESIGN LOADS:
1. DEAD LOAD: 15 PSF
2. LIVE LOAD: 25 PSF
3. SNOW EXPOSURE FACTOR:.9
4. SNOW LOAD IMPORTANCE FACTOR: 1.0
5. THERMAL FACTOR: 1.0
b. MAXIMUM DEFLECTION UNDER DESIGN LOADS:
1. ROOF TRUSSES: VERTICAL DEFLECTION OF 1I360
OF SPAN.
2. ROOF TRUSSES: HORIZONTAL DEFLECTION AT
REACTIONS OF 1-1/41NCHES.
2.01 MATERIALS
A. LUMBER:
c. LUMBER USED FOR TRUSS MEMBERS SHALL BE IN
ACCORDANCE WITH PUBLISHED VALUES OF LUMBER
RULES WRITING AGENCIES APPROVED BY BOARD OF
REVIEW OF AMERICAN WMBER STANDARDS COMMITTEE.
LUMBER SHALL BE IDENTIFIED BY GRADE MARK OF A
WMBER INSPECTION BUREAU OR AGENCY APPROVED BY
THAT BOARD, AND SHALL BE AS SHOWN ON DESIGN
DRAWINGS.
d. MOISTURE CONTENT OF LUMBER SHALL BE NO LESS THAN
7 PERCENT NOR GREATER THAN 19 PERCENT AT TIME OF
FABRICATION.
POOL HOUSE FOUNDATION PLAN
SCALB 1/4" = 1'-0"
e. ADJUSTMENT OF VALUES FOR DURATION OF LOAD OR
CONDITIONS OF USE SHALL BE IN ACCORDANCE WITH THE
NATIONAL DESIGN SPECIFICATIONS FOR WOOD
CONSTRUCTION (NDS).
f. FIRE RETARDANT TREATED LUMBER, IF APPLICABLE SHALL
MEET SPEGFICATIONS OF TRUSS DESIGN AND ANSI/TPI 1-
1995, PAR 9.1.5 AND SHALL BE RE-DRIED AFTER
TREATMENT IN ACCORDANCE WITH AWPA STANDARD C20.
ALLOWABLE VAW ES MUST BE ADJUSTED IN ACCORDANCE
WITH NDS PAR 2.3.6. LUMBER TREATER SHALL SUPPLY
CERTIFICATE OF COMPLIANCE.
B.METAL CONNECTOR PLATES:
METAL CONNECTOR PLATES SHALL MEET OR EXCEED ASTM A653-
94 GRADE 3 AND SHALL BE HOT DIPPED GALVANIZED ACCORDING
TO ASTM A653-94, COATING DESIGNATION G60. WORKING
STRESSES IN STEEL ARE TO BE APPLIED TO EFFECTIVE RATIOS
FOR PLATES AS DETERMINED BY TESTING IN ACCORDANCE WITH
APPENDIX E AND F OF ANSI?PI 1-1995.
2.02 TRUSS FABRICATION
TRUSSES SHALL BE FABRICATED IN A PROPERLY EQUIPPED
MANUFACTURING FACILITY OF A PERMANENT NATURE.
TRUSSES SHALL BE MANUFACTURED BY EXPERIENCED
WORKMEN, USING PRECISION CUTTING, JIGGING, AND PRESSING
EQUIPMENT MEETING REQUIREMENTS OF ANSIITPI 1-1995,
SECTION 4. TRUSS MEMBERS SHALL BE ACCURATELY CUT TO
LENGTH ANGLE AND TRUE LWE TO ASSURE PROPER FITTING
JOINTS WITHIN TOLERANCES SET FORTH IN ANSIITPI 1-1995,
SECTION 4, AND PROPER FIT WITH OTHER WORK.
3.01 HANDLING, INSTALLATION AND BRACING OF ROOF AND FLOOR
TRUSSES
1. TRUSS DELIVERY SHALL BE SCHEDULED REASONABLY NEAR
THE SCHEDULED TIME OF ERECTION.
2. TRUSSES SHALL BE HANDLED DURING FABRICATION,
DELIVERY AND AT JOB SITE SO AS NOT TO BE SUBJECTED
EXCESSIVE BENDING.
3. TRUSSES SHALL BE UNLOADED ON SMOOTH GROUND TO
AVOID LATERAL STRAIN. TRUSSES SHALL BE PROTECTED
FROM DAMAGE THAT MIGHT RESULT FROM ON-SITE ACTIVITIES
AND ENVIRONMENTAL CONDITIONS. PREVENT TOPPLING
WHEN BANDING IS REMOVED.
4. UPON ARRIVAL AND DURING THE UNLOADING PROCESS,
TRUSSES SHALL BE INSPECTED FOR DAMAGE.
5. HANDLE DURING INSTALLATION IN ACCORDANCE WITH
HANDLING, INSTALLING AND BRACING WOOD TRUSSES (HIB-
91), TPI, AND ANSI/TPI 1-1995. INSTALLATION SHALL BE
CONSISTENT WITH GOOD WORKMANSHIP AND GOOD BUILDING
PRACTICES AND SHALL BE RESPONSIBILITY OF TRUSS
INSTALLER.
6. APPARENT DAMAGE TO TRUSSES, IF ANY, SHALL BE
REPORTED TO MANUFACTURER PRIOR TOINSTALLATION.
7. TRUSSES SHALL BE SET AND SECURED LEVEL AND PWMB,
AND IN CORRECT LOCATION. TRUSSES SHALL BE HELD TO
CORRECT ALIGNMENT UNTIL SPEGFlED PERMANENT BRACING
ISINSTALLED.
8. CUTTING AND ALTERING OF TRUSSES IS NOT PERMITTED.
9. CONCENTRATED LOADS SHALL NOT BE PLACED ATOP
TRUSSES UNTIL ALL SPECIFIED BRACING HAS BEEN INSTALLED
AND DECKING IS PERMANENTLY NAILED IN PLACE.
SPEGFICALLY AVOID STACKING FULL BUNDLES OF DECKING
OR OTHER HEAVY MATERIAL ONTO UNSHEATHED TRUSSES.
10. ERECTION BRACING IS REQUIRED. PREVENT TOPPLING OR
"DOMINOING" (CASCADING COLLAPSE) OR TRUSSES DURING
INSTALLATION.
11. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND
FURNISHING THE MATERIALS USED FOR INSTALLATION OF
PERMANENT BRACING.
3.02 REPAIRS AND PROTECTION:
REPAIR DAMAGED GALVANIZED COATINGS ON ESPOSED SURFACES
WITH GALVANIZED REPAIR PAINT ACCORDING TO ASTM A 780.
REPAIR OR REPLACE TRUSSES OR ACCESSORIES DAMAGED IN
DELIVERY OR INSTALLATION IMMEDIATELY.
END
�
�
�