Loading...
HomeMy WebLinkAboutA000.11901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central Zone........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette3/30/2015 GARAGE RIGHT 2975-Naples 1815.0000 LOT 06 11/14/2019 PLOTTED: November 14, 2019 / Kamlesh Bisht / 2975-IN-NAPLES-EC01.DWG A3-EC01 1FB.1Euro Country2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule2030 FX 8:12 \A1;2'-6" 8:1212:12 8:12 12:1212:1212:12 3:12 \A1;3'-1"\A1;3'-1" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT \A1;1'-0" \A1;7'-8{\H0.750000x;\S3#8;}"\A1;7'-4{\H0.750000x;\S3#4;}" \A1;4'-0"\A1;4'-0"2650 FX SCALE:FRONT ELEVATION1/4" = 1'-0"- ROOF SHINGLES, PER SPEC FYPON #LV12X24 OR APPROVED EQUAL \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION 8" FASCIA, PER SPEC8" FRIEZE, PER SPEC4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC BRICK SOLDIER COURSE, PER SPEC18"x60" PANEL SHUTTERS, PER SPEC BRICK SOLDIER COURSE, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC 4" FRIEZE, PER SPEC STONE SILL, PER SPECSTONE VENEER, PER SPEC 1214 4" FRIEZE, PER SPEC 1214 12141214 1214 1214 1214 1214 1214 BLACKOUT WINDOW 4" TRIM BOARD, PER SPEC 6" TRIM BOARD, PER SPECFYPON BRACKET #DTLB6X6X5\POR APPROVED EQUAL6" TRIM BOARD, PER SPEC \A1;3'-6"\A1;MIN. TOP OF FOOTING STONE SILL, PER SPEC BRICK WAINSCOT, PER SPEC 1214 SCALE:ROOF PLAN1/8" = 1'-0"- \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. "A"2986ROOF AREA:SQ. FT. "B"28ROOF AREA:SQ. FT. 14:12 14:12 14:12 \pxi-4,l4,ql,t3;POT VENT\A1;13'-0" \A1;5'-8{\H0.750000x;\S1#2;}"\A1;2'-7" \A1;7'-5" \A1;1'-3" \A1;2'-7" \A1;6'-10{\H0.750000x;\S1#4;}" \A1;32'-8" \A1;3'-6"\A1;2'-5" \A1;3'-6"\A1;3'-6" 14:1214:12 14:1214:1214:12 14:12 14:12 14:12 14:1214:1214:1214:12 8:12 8:12 8:128:12 8:12 14:128:12 \A1;12'-0" \A1;5'-0" 8:12 8:12 3:12 8:1214:12 \A1;4'-0" SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}"\A1;3'-6"\A1;MIN. ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC BLACKOUT WINDOW BRICK MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC4" TRIM BOARD (TYP.), PER SPEC \A1;3'-6" \A1;7'-1{\H0.750000x;\S1#8;}"\A1;HEAD HT. 123 128128128 1214 128 2030 FX2030 FX 1x3 OVER 6" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC 10" FRIEZE, PER SPEC 4" TRIM BOARD, PER SPEC \A1;15'-6{\H0.750000x;\S1#8;}" TOP OF PLATE ROOF SHINGLES, PER SPEC WINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPEC4" TRIM BOARD (TYP.), PER SPECHORIZONTAL SIDING, PER SPECBRICK MASONRY WRAP, PER SPECSTONE VENEER, PER SPECBRICK SOLDIER COURSE, PER SPEC 4" FRIEZE, PER SPEC10" FRIEZE, PER SPEC SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;3'-6" \A1;15'-6{\H0.750000x;\S1#4;}" TOP OF PLATE1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC 128128 128128 128128 \A1;3'-6"\A1;MIN. TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" 1214 BRICK MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPECHARDIE PANEL (SMOOTH), PER SPEC6" TRIM BOARD (TYP.), PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- \A1;15'-6{\H0.750000x;\S1#8;}"\A1;PLATE HT. 12141214 1214 8" TRIM BOARD, PER SPEC 4" TRIM BOARD, PER SPEC 6" TRIM BOARD (TYP.), PER SPEC ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2986 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.98 4.98 4.66 46.89 11 0 AT EAVE 5.97 4.98 5.28 53.11 0 76.00 TOTAL (MIN)9.95 9.95 9.94 100.00 3 HIGH - RIDGE VENT 3.98 4.98 5.00 50.00 0 0 40.00 AT EAVE 5.97 4.98 5.00 50.00 0 72.00 TOTAL (MIN)9.95 9.95 10.00 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 28 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.04 0.05 0.28 80.00 0 1 AT EAVE 0.06 0.05 0.07 20.00 0 1.00 TOTAL (MIN)0.09 0.09 0.35 100.00 3 HIGH - RIDGE VENT 0.04 0.05 0.13 64.29 0 0 1.00 AT EAVE 0.06 0.05 0.07 35.71 0 1.00 TOTAL (MIN)0.09 0.09 0.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 12/10/19 David Rutti