HomeMy WebLinkAboutE200.01901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central Zone...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
Suzette Schuette3/30/2015
GARAGE RIGHT
2975-Naples
1815.0000
LOT 06
11/14/2019
PLOTTED: November 14, 2019 / Kamlesh Bisht / 2975-IN-MEPP.DWG Second FloorElectrical Plan6.12
\A1;3'-0"\pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACLES INTENDED TO SERVE THE COUNTER TOP SURFACES OF A WET BAR THAT ARE LOCATED WITHIN 6'-0" OF THE OUTSIDE EDGE OF THE WET BAR SINK\P - LESS THAN 25'-0" FROM THE AIR CONDITIONING UNIT\P\P3. PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN, DINING AND PANTRY AREAS LIMITED TO ONLY THE REQUIRED WALL AND COUNTERTOP OUTLETS, AND THE REFRIGERATOR.\P\P4. REQUIRED LAUNDRY RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P\P5. REQUIRED BATHROOM RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P \P6. ARC-FAULT CIRCUIT INTERRUPTION PROTECTIONS SHALL BE PROVIDED FOR ALL CIRCUITS SUPPLYING POWER TO BEDROOMS.\P\P7. ALL ELECTRICAL OUTLETS SHALL BE PLACED AT 15" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS NOTED IN THE FOLLOWING NOTES OR ON PLANS.\P\P8. ALL ELECTRICAL OUTLETS AT KITCHEN COUNTERS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P\P9. ALL ELECTRICAL OUTLETS AT BATHROOMS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR AT 36" HIGH COUNTERS, AND 40" ABOVE FINISHED FLOOR AT 32" HIGH COUNTERS, UNLESS OTHERWISE NOTED ON PLANS.\P\P10. ALL SWITCHES SHALL BE PLACED AT 38" TO CENTER OF SWITCH ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P\P11. ALL WALL MOUNTED LIGHT FIXTURES SHALL BE SET AT A HEIGHT OF 66" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P\ptz;\P12. SMOKE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER R314.4. SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER R314.4. INSTALLATION SHALL MEET NFPA 72-70. SMOKE DETECTORS SHALL BE LOCATED ON EACH FLOOR LEVEL IN THE VICINITY OF ALL BEDROOM ENTRANCE DOORS AND WITHIN EACH BEDROOM.\P\pt1;\P13. CARBON MONOXIDE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER R314.4. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER R314.4. A CARBON MONOXIDE ALARM IS REQUIRED OUTSIDE EACH SLEEPING AREA AND/OR IN THE IMMODERATE VICINITY OF SLEEPING AREAS AS REQUIRED PER R315. DETECTORS SHALL COMPLY WITH UL2034-2008.\P\P14. LIGHTING IN CLOTHES CLOSETS SHALL BE FULLY ENCLOSED AND INSTALLED PER N.E.C. 410.16. FIXTURES MAY NE LOCATED ONLY WHERE THERE ARE THE FOLLOWING MINIMUM CLEARANCES TO THE NEAREST POINT OF STORAGE SPACE:\P\pa0.83333; - SURFACE MOUNTED INCANDESCENT FIXTURES: 12" MINIMUM\P - SURFACE MOUNTED FLUORESCENT FIXTURES AND RECESSED FIXTURES: 6" MINIMUM.\P\P15. NO PARTS OF HANGING FIXTURES, TRACK LIGHTING, AND CEILING PADDLE FANS SHALL BE INSTALLED WITHIN 3'-0" HORIZONTALLY OF A BATHTUB, MEASURED FROM THE OUTSIDE EDGE OF THE TUB AND 8'-0" VERTICALLY FROM THE TOP OF THE TUB RIM.\P\pa0.25,tz;\P16. RECEPTACLES SHALL NOT BE INSTALLED WITHIN A TUB OR A SHOWER ENCLOSURE.\P\pt1;\P17. GROUNDING: RECEPTACLE OUTLETS FOR RANGES AND CLOTHES DRYER MUST BE A 3-POLE WITH GROUND TYPE.\P\P18. INTERSYSTEM BONDING TERMINAL SHALL BE PROVIDED FOR GROUNDING COMMUNICATION SYSTEMS (CABLE TV & SATELLITE DISHES).\P\P19. GROUNDING AND BONDING OF METAL PIPING SYSTEMS SHALL MEET THE REQUIREMENTS OF THE N.E.C. SECTION 250.104. \P\P20. MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT.\P\P21. VERIFY LOCATION OF ALL RECEPTACLES FOR APPLIANCES WITH MANUFACTURER SPECIFICATIONS.\P\P22. ALL CONVENIENCE OUTLETS WITH SWITCHES TO BE SWITCH AT TOP ONLY.\P\P23. ELECTRICAL CONTRACTOR SHALL VERIFY SPACE REQUIRED FOR METER INSTALLATION BEFORE CONSTRUCTION AND SHALL NOTIFY GENERAL CONTRACTOR OF ANY DISCREPANCIES.\P\P24. LIGHT FIXTURES ABOVE WHIRLPOOL, TUBS AND SHOWERS SHALL BE G.F.I. (SEC. 680.22.B.4, NEC)}UTILITY NOTESElectrical Schedule TableElectrical Schedule Table
\A1;1'-6"
\A1;4'-6"
\A1;4'-0"
\A1;3'-0"GFI
GFI
3S
3S
SS
SS
R
TO SWITCH BELOW
3S3S
3S
S/C
S
R
R
R
FAN/LIGHT, VENT \PTO EXT.
S
BEDROOM 3LINBEDROOM 2
BATH 2
OPEN TO
BELOW
BONUS ROOM SS
R
OPEN TO
BELOW
SECOND FLOOR ELECTRICAL PLAN1/4" = 1'-0"
12/10/19
David Rutti