Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S000.3
PLAN NAME SHEET COMMUNITY NAME PRODUCTION MANAGER LAWSON COMMUNITY ID RELEASE DATE:DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME SPECIFICATION LEVEL GARAGE HANDING REV # PROJECT TYPENOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS CURRENT ARCHITECT OF RECORD:ENGINEER OF RECORD: 4/25/13JGF (c) Copyright PulteGroup, Inc. - 2011 Pulte Central Zone1901 North Roselle Road, Suite 1000Schaumburg, Indiana 60195SINGLE FAMILY -------- ---- ---- ---- ---- ---- ---- ---- PULTE GROUPMULHERN & KULP 16TYPICAL COLUMN TO FOOTING CONNECTION w/ STEEL BEAMSCALE: 3/4"=1'-0" \A1;ADJUSTABLE PIPE COLUMN\P-SEE PLAN FLOOR JOISTS -SEE PLAN CONC. FTG.\P-SEE PLAN \A1;COLUMN CAPACITY MUST BE RATED FOR A MINIMUM OF 18k @ 8'-3" TALL W/0 SCREW JACK EMBEDDED IN CONCRETE. 11TYPICAL WALKOUT BASEMENT FOUNDATIONSCALE: 3/4"=1'-0" \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL CODE) \A1;8" MIN \A1;{\H1x;GRADE} \A1;TYP. SILL PLATE -SEE 1/SD.01 TYP. BSMT. SLAB\P-SEE 1/SD.01 FASTEN SHEATHING TO SILL PLATE PER EXT. WALL/ SHEARWALL EDGE NAILING REQUIREMENTS (SEE PLANS) TYP. BSMT. SLAB\P-SEE 1/SD.01 15TYPICAL THICKENED SLAB @ INTERIOR BEARING WALLSCALE: 3/4"=1'-0" 2x P.T. BOTTOM PLATE w/ HILTI DNI 72 P8 PINS OR EQUAL @ 36" o.c. INTERIOR BEARING WALL \A1;16" \A1;8" TYP. BSMT. SLAB\P-SEE 1/SD.01 10SCALE: 3/4"=1'-0" GRADE \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL CODE) BRICK VENEER (QUEEN BRICK) \Pw/ 1" W. x 22GA CORRUGATED GALV. METAL WALL TIES \P@ 32" o.c. HORIZ.\P& @ 16" o.c. VERT. (TYP.) GROUT SOLID TO \PWEEP HOLES @ 24" o.c. 1" AIR SPACE \A1;VARIESTYP. GARAGE SLAB\P-SEE 5/SD.01 \A1;2x4 WALL\P-SEE PLANS 12TYPICAL WALKOUT BASEMENT FOUNDATION @ DOORSCALE: 3/4"=1'-0" \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL CODE) \A1;8" MIN \A1;7 {\H0.7x;\S1#2;\H1.4286x;"} PLAIN CONC. FDN. STEM WALL \A1;{\H1x;GRADE} \A1;3 {\H0.7x;\S1#2;}"\A1;4" TYP. BSMT. SLAB\P-SEE 1/SD.01 DOOR PER ARCH\P-SEE PLANS \A1;DOOR THRESHOLD OVER 3 BEADS OF CAULK 13TYPICAL GARDEN BASEMENT FOUNDATIONSCALE: 3/4"=1'-0" \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL CODE) \A1;8" MIN \A1;7 {\H0.7x;\S1#2;\H1.4286x;"} PLAIN CONC. FDN. STEM WALL\A1;{\H1x;GRADE} \A1;TYP. SILL PLATE -SEE 1/SD.01FASTEN SHEATHING TO SILL PLATE PER EXT. WALL/ SHEARWALL EDGE NAILING REQUIREMENTS (SEE PLANS) TYP. FOOTING \P-SEE 1/SD.01 TYP. BSMT. SLAB\P-SEE 1/SD.01 TYP. FOOTING w/ BRICK\P-SEE 2/SD.01 \A1;TYP. SILL PLATE -SEE 1/SD.01 TYP. FOOTING\P-SEE 1/SD.01 \A1;3'-8 1/2" 2x PLATE FASTENED TO STEEL BEAM\P-SEE STRUCT. NOTESSTEEL BEAM\P-SEE PLAN \A1;COLUMN CAP w/ TABS BENT AROUND BOTTOM FLANGE OR "H" SHAPED PLATE w/ (2) {\H0.7x;\S1#2;}" BOLTS \A1;7 {\H0.7x;\S1#2;\H1.4286x;"} PLAIN CONC. FDN. STEM WALL 11ATYPICAL WALKOUT BASEMENT FOUNDATIONSCALE: 3/4"=1'-0" \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL CODE) \A1;8" MIN \A1;{\H1x;GRADE} \A1;TYP. SILL PLATE -SEE 1/SD.01 TYP. BSMT. SLAB\P-SEE 1/SD.01 \A1;2x4 WALL\P-SEE PLANS 13ATYPICAL GARDEN BASEMENT FOUNDATIONSCALE: 3/4"=1'-0" \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL CODE) \A1;8" MIN \A1;7 {\H0.7x;\S1#2;\H1.4286x;"} PLAIN CONC. FDN. STEM WALL\A1;{\H1x;GRADE} \A1;TYP. SILL PLATE -SEE 1/SD.01 TYP. FOOTING w/BRICK\P-SEE 2/SD.01 TYP. BSMT. SLAB\P-SEE 1/SD.01 \A1;3'-8 1/2" BRICK VENEER (QUEEN BRICK) \Pw/ 1" W. x 22GA CORRUGATED GALV. METAL WALL TIES \P@ 32" o.c. HORIZ.\P& @ 16" o.c. VERT. (TYP.) GROUT SOLID TO \PWEEP HOLES @ 24" o.c. 1" AIR SPACE \A1;2x4 WALL\P-SEE PLANS \A1;2x4 WALL\P-SEE PLANSBRICK VENEER (QUEEN BRICK) \Pw/ 1" W. x 22GA CORRUGATED GALV. METAL WALL TIES \P@ 32" o.c. HORIZ.\P& @ 16" o.c. VERT. (TYP.) GROUT SOLID TO \PWEEP HOLES @ 24" o.c. 1" AIR SPACE TYPICAL EXT. GARAGE FOUNDATION w/ BRICK VENEER w/ BRICK VENEER w/ BRICK VENEER 14TYPICAL CONCRETE HEADER @ BASEMENTSCALE: 3/4"=1'-0" FLOOR JOISTS \P-SEE PLAN \A1;1 {\H0.7x;\S1#8;\H1.429x;" OSB RIM JOIST OR FLUSH BEAM\P-SEE PLAN} LINE OF FOUNDATION WALL BEYOND \A1;CONC. HEADER \P(16" MIN. HT) \A1;(2) #5 BARS ON ALL SIDES EXTENDED 24" PAST OPENING @ EACH END \A1;1 1/2"\PCOVER \A1;TYP. SILL PLATE -SEE 1/SD.01 TYP. BSMT. WALL\P-SEE 1/SD.01 \A1;WINDOW HT. PER ARCH \A1;{\H1x;FOOTING}\A1;SLAB \A1;TOP OF FOUNDATION WALL CONC. WALL OPENING\P-SEE ARCH ELEVATION (N.T.S.) \A1;3 {\H0.7x;\S1#2;}"\A1;4" SD.0217CONCRETE FDN. @ GARAGE SLABSCALE: 3/4"=1'-0" \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL \PCODE) \A1;9'-0" MAX. \A1;{\H1x;GRADE} FASTEN SHEATHING TO SILL PLATE PER EXT. WALL/ SHEARWALL EDGE NAILING REQUIREMENTS (SEE PLANS) 8" REINFORCED CONC. WALL w/ #4 BARS @ 18"o.c. VERT AND (4) #4 BARS HORZ. LOCATE REINF IN CENTER OF WALL \A1;8'-0" MAX. OVERDIG AREA \PTO 95% COMPACTED FILL\P/ VIRGIN SOIL \A1;VARIES \A1;TYP. SILL PLATE -SEE 1/SD-1.0 \A1;\pxql;EPOXY SET #4 DOWELS W/ HILTI HY-200 EPOXY SYSTEM AND 4 {\H0.7x;\S1#4;}" EMBEDMENT @ 16" o.c. \P- LAP 24" (MIN.) w/ SLAB REINF. {\LSTRUCTURAL GARAGE SLAB @ OVERDIG:\P}5" REINF. CONC. SLAB w/ #4 BARS @ 16" o.c. EA. WAY @ MID-DEPTH {\LGARAGE WALL FOOTING:\P}8x24 PLAIN CONC. FTG.\P-PROVIDE #4 BENT DOWELS DOWELS @ 18" o.c. w/ 4" HOOK AND 30" LAP w/ VERT REBAR \A1;UNCOMPACTED FILL\A1;4 1/4" LOW GRADE EXTERIOR 17CONCRETE FDN. @ GARAGE SLABSCALE: 3/4"=1'-0" \A1;MIN. FROST DEPTH\A1;(CONSULT LOCAL \PCODE) \A1;5'-0" MAX. \A1;{\H1x;GRADE} FASTEN SHEATHING TO SILL PLATE PER EXT. WALL/ SHEARWALL EDGE NAILING REQUIREMENTS (SEE PLANS) 8" REINFORCED CONC. WALL w/ #4 BARS @ 24"o.c. VERT AND (3) #4 BARS HORZ. LOCATE REINF IN CENTER OF WALL \A1;8'-0" MAX. OVERDIG AREA \PTO 95% COMPACTED FILL\P/ VIRGIN SOIL \A1;VARIES \A1;TYP. SILL PLATE -SEE 1/SD-1.0 \A1;\pxql;EPOXY SET #4 DOWELS W/ HILTI HY-200 EPOXY SYSTEM AND 4 {\H0.7x;\S1#4;}" EMBEDMENT @ 16" o.c. \P- LAP 24" (MIN.) w/ SLAB REINF. {\LSTRUCTURAL GARAGE SLAB @ OVERDIG:\P}5" REINF. CONC. SLAB w/ #4 BARS @ 16" o.c. EA. WAY @ MID-DEPTH {\LGARAGE WALL FOOTING:\P}8x20 PLAIN CONC. FTG.\P-PROVIDE #4 BENT DOWELS DOWELS @ 24" o.c. w/ 4" HOOK AND 30" LAP w/ VERT REBAR \A1;UNCOMPACTED FILL\A1;4 1/4" LOW GRADE EXTERIOR \A1;1'-0"\A1;8"\A1;1'-4"\A1;8" \A1;STRUCTURAL SLAB SHALL EXTEND 24" MIN ONTO BEARING SOIL \A1;STRUCTURAL SLAB SHALL EXTEND 24" MIN ONTO BEARING SOIL CL\POF WALL CL\POF WALL COMPACTED BACKFILL{\LTYP. PORCH SLAB:}\PSEE 3/SD.01 BRICK MASON TO LEAVE OUT EVERY OTHER BRICK OF FIRST COURSE TO ALLOW PORCH SLAB TO POUR ONTO CONCRETE WALL LEDGE BRICK VENEER (QUEEN BRICK)\Pw/ 1" W. x 22GA CORRUGATED GALV. METAL WALL TIES \P@ 32" o.c. HORIZ.\P& @ 16" o.c. VERT. (TYP.) GROUT SOLID TO \PWEEP HOLES @ 24" o.c.1" AIR SPACE \A1;VARIES TYP. GARAGE SLAB\P-SEE 5/SD.01 \A1;TYP. SILL PLATE -SEE 1/SD.01 AT PORCH \A1;08/05/2013 9'-0" MAX UNBALANCED FILL 5'-0" MAX UNBALANCED FILL \A1;2"\A1;4"\A1;3" \pxql;12" PLAIN CONC. TRENCH FOOTING (@2000 PSF SOIL)\P16" WIDE (@1500 PSF SOIL) w/ 16" LONG #4 REBAR DOWELS INTO STEM WALL (MIN 4" IN TRENCH FTG. & 12" EXT. INTO STEM WALL) \A1;3" \A1;6"x16" FND. STEM WALL w/ 1{\H0.7x;\S1#2;}" WIDE x 5{\H0.7x;\S1#2;}" SLAB LEDGE \A1;2"\A1;4"\A1;3 1/2"\A1;2 1/2"\pxql;12" PLAIN CONC. TRENCH FOOTING (@2000 PSF SOIL)\P16" WIDE (@1500 PSF SOIL) w/ 16" LONG #4 REBAR DOWELS INTO STEM WALL (MIN 4" IN TRENCH FTG. & 12" EXT. INTO STEM WALL) 8"x16" FND. STEM WALL w/ 4" BRICK LEDGE \A1;03/14/2014 \A1;CORBEL BRICK {\H0.7x;\S1#2;}" MAX. PER COURSE & 1" MAX TOTAL AS REQUIRED \A1;CORBEL BRICK {\H0.7x;\S1#2;}" MAX. PER COURSE & 1" MAX TOTAL AS REQUIRED \A1;CORBEL BRICK {\H0.7x;\S1#2;}" MAX. PER COURSE & 1" MAX TOTAL AS REQUIRED Indiana DivisionTypical Foundation DetailsNo Ledge at Porch\A1;04/28/2014 19TYPICAL STEPPED FOOTING @ GARAGE/BASEMENT INTERFACESCALE: 3/4"=1'-0" BASMENT AND SHALLOW STEM FDN WALLS TO BE POURED MONOLITHICALLY HIGH FOOTING AREA OF UNSTABLE SOIL \A1;3" MIN. COVER \A1;16" MIN. (2) #4 BARS 8'-0" LONG w/ 16" EXTENSION INTO BASEMENT WALL (BEND BAR AS REQUIRED AT PERPENDICULAR WALL INTERSECTION TO GET REQ'D EXTENSION \A1;3'-0" MAX. FOOTING BULKHEAD AT FACE OF BASEMENT OVER-DIG AREA LINE OF UNDISTURBED SOIL X-XSECTIONSCALE: 3/4"=1'-0" X PLAIN CONC. FTG.\P-SEE 1/SD.01 (2/SD.01 @ BRICK) TYP. BSMT. WALL\P-SEE 1/SD.01\P(2/SD.01 @ BRICK) TYP. BSMT. SLAB\P-SEE 1/SD.01 X \A1;7 {\H0.7x;\S1#2;}" PLAIN CONC. WALL TYP. GARAGE WALL FOOTING\P-SEE 7/SD.01 \A1;42" MAX VOID (2) #4 BARS 8'-0" LONG w/ 16" EXTENSION INTO BASEMENT WALL (BEND BAR AS REQUIRED AT PERPENDICULAR WALL INTERSECTION TO GET REQ'D EXTENSION PLOTTED: April 28, 2015 / Andrew Moore / IND CENTRAL ZONE - MASTER FOUNDATION DETAILS - NO LEDGE.DWG P:\Client Files\125 - Pulte Central Zone\Master Client admin\Master Details\Central Zone Master Fnd Detail Files\IND Central Zone - Master Foundation Details - No Ledge.dwg, 4/28/2015 2:05:42 PM, DWF6 ePlot.pc3 12/10/19 David Rutti