Loading...
HomeMy WebLinkAboutGN020.0GENERAL PROJECT NOTES I. BUILDINGCODECOMPLIANCE:ALLWORKSHALLCOMPLYWIiHiHE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION iVPEAS DEFINED BY SEQION 601 OF iHE INDIANA BUILDWG CODE AND ALL APPLICABLE SiAiE AND LOCAL BUILDING CODES. CONiRACiORS ARE RESPONSIBLE FOR VERIFVING TH E Cl1RRENT APPLICABLE Bl11LDING CODE S �) FOR iH EIR RESPEQIV E SCOPE OF W ORK. ENSURE iHAi ALL MAiERIALS AND LABOR ARE IN ACCORDANCE WIiH iHE BESi QUALIiY SiANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFlED OR NOT. THE GENERAL CONiRACiOR IS RESPONSIBLE FOR ENSURWG iHAi ALL WORK IS IN ACCORDANCE WIiH ALL FEDERAL, SiAiE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL MECHANICAL AND ELECTRICAL CONARUCiION_ 2. CONiRACiORSIiEVISITS:CONiRAQOR�S�SHALLVISIiiHEWORKSIiE PRIOR TO COMMENCEMENT. TH E DRAW INGS CONTA W ED HEREIN MAV NOiBEALLINCLUSNEOFE%IAWGCONDIiIONSORNEW WORK REQUIREMENTS. CONTRACTOR�S�SHALLMAKETHEMSELVESFAMILIAR WITH TH E W ORK SITHN TH E RELD I N ORDER TO BE Fl1LLV AW ARE OF THE REQUIREMENiS OF iHE SCOPE OF WORK. 3. CONiRACiOR FIELO VERIFICAiION: FlELD VERIFY ALL DIMENSIONS AN D MEASUREMENTS. W FORM TH E GENERAL CONTRACTOR BEFORE BEGINNWG ANY CONSiRUQION IF EXISiWG CONDIiIONS PREVENi OBiAINING RESULiS AS SHOW N OR SPECIFIED. DO NOi SCALE DRAW INGS; NOTED DIMENSIONS TAKE PRECEDENCE VERIFV E%ISTING CONDITIONS INDICAiE9 ON iHE DRAW WGS AND REPORi ANV DISCREPANCIES iHROUGH iHE GENERAL CONiRACiOR i0 SCHOii DESIGN, WC. 4. GENERALCONiRACiORCOORDINAiIONWIiHOWNER:THEGENERAL CONiRACiOR SHALL COORDINAiE W IiH iH E OW NER REGARDW G ALL ON-SIiE ACilvlilES SUCH AS, BUi NOi LIMIiED i0: WORK SCHEDULE, MAiERIALS SiORAGE AND HANDLING, DELNERIES, ACCESS i0 iHE WORK SITE TRAFFlC CONTROL AND Bl11LDING/Pl1BLIC SAFEiV PROCEDl1RES DURW G CONSiRUQION. iH E CONiRAQOR SHALL ALSO COORDINAiE WORK "BY OiHERS" WIiH HIS/HER OW N AQIVIiIES AS NECESSARY i0 EXEC UTE TH E OV ERALL PROJECT SCOPE THE GEN ERAL CONTRACTOR SHALL COORDINAiE W IiH iHE LANDLORD, DAILV WORKWG HOURS. W EEKEND HOURS AND HOURS iHAi MAY BE WORKED PRIOR i0 AND DURING HOIJDAVS. LANDLORD RESERVES THE RIGHTTO RESTRICT CONARUCiION i0 NIGHiS AND W EEKENDS W H EN iHAi CONARUCiION IS DEEMED iOINiERFERE W IiH iHE OPERAiIONS OF ADJACENi iENANiS. 5. PROJECiMAiERIALLEADiIMESFORTHWEITEMSTOBEORDERED REQl11RING LEAD TIME THE CONTRACTOR SHALL COORDINATE THE PROJEQ SCHEDULE ACCORDW GLY AND COMMUNICAiE i0 iHE O W NER, iENANi, AND SCHOii DESIGN W H EN DECISIONS MUSi BE RENDERED I N ORDER FOR THE CONTRACTOR TO MEEf TH E PROJECT SCHEDl1LE THE OW NER, iENANi, OR DESIGNER/ARCH IiECi IS NIN RESPONSIBLE FOR DELAYS RESULiING FROM iHE CONiRACiOR'S FAILURE i0 COMMUNICAiE MATERIAL LEAD TIMES. 6- MAiERIAL5UB5iliUilONS: SUBAIiUiIONS FORSPECIFlCALLV NAMED PRODUQS WILL NOi BE ALLOW ED WIiHOUi PRIOR APPROVAL FROM iHE DESIGNER. SUBMIT REQUESTS FOR SU&STITUTIONS WITH APPROPRIATE Sl1PPORT W FORMATION TO THE DESIGNER. ALLOW REASONABLV SUFFlCIENi iIME FOR iH E DESIGN ER i0 REVIEW iHE REQUESi AND RENDER A DECISION. ]. SAFEWORKAREA:SCHOTfDESIGN,INC.,SHALLNOTHAVECONTROL OVER, BE W CHARGE OF, OR BE RESPONSIBLE FOR A CONiRACiOR'S CONSiRUCiION MEANS, MHHODS,SCHEDULES,SEQUENCES, OR SAFHY. TH E CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMEM FOR WORKERS AND iHE PUBLIC Ai ALL iIMES_ 8. GENERALCONiRACiORCLEANUPPROCEDURES:iHEGENERAL CONiRACiOR SHALL ESiABLISH W IiH iH E LANDLORD QEANUP PROCEDURES AND GUIDEIJN ES TO BE FOLLOW ED ON A DAILV BASIS IN ORDER i0 CONDUQ BUSIN ESS IN A SAFE AN D CLEAN ENVIRONMENi. 9. SiAGING/PARKING/OUMPSiERS/RESiROOMS:iHEGENERAL CONTRACTOR SHALL COORDINATE W ITH TH E LAN DLORD AN AREA FOR SiAGWG OF CONSiRUQION MAiERIALS, EpUIPMENi, DUMPSiER AND PARKING CONSiRUCiION AND DRIVERY VEHIQES. iHE USE OF EXISiING RESTROOM FACILITIES SHALL BE APPROV ED BV THE LANDLORD. ONLV iHOSE DESIGNAiED AREAS SHALL BE USED BV CONARUCiION CREW S- 10. DUSiCONiROL:iHEGENERALCONiRACiORSHALLUSEDUSi PARTITIONS TO MINIMIZE DISTl1RBANCES OF DAILV TENANT OPERATIONS DURWG DEMOLIiION AND CONARUCiION WORK_ DUA PARiIiIONS SHALL BE CONSiRUQED OF 2X4 W OOD SiUDS ts 24"O.C., INSULAiION AND 6 MIL VAPOR BARRIER ON EACH SIDE. IL PROJECiINSiALLAiIONCONFLICitCONiAQiHEDESIGNER IMMEDIAiELY IF CONFLICiS ARE DISCOVERED IN iHE FIELD BEiWEEN COMPONENTS OF DIFFERENT SVSTEMS THAT PREVENT THE WSTALLATION OF iHOSE COMPONENiS AS INDICAiED ON iHE DRAWINGS. �I.E. WHERE EXISiING MECHANICAL DUCiWORK MAY PREVENi iHE INSiALLAiION OF LIGHiWG FIXiURES AS INDICAiED ON iHE CEILWG PUN�. 12. SCHOiT DESIGN HAZARDOUS MAiERIALS WAIVER: SCHOii DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFlCATION, DISCOVERV, PRESENCE HANDLING. REMOVAL DISPOSAL OF, OR E%POSURETOANV PERSONS, iHAi OF HAZARDOUS MAiERIALS IN ANY FORM ON iHE PROJECTSITE. 13- WOOD BLOCKING IN WALR: PROVIDE FlRE-iREAiED WOOD BLOCKWG IN WALLS FOR ALL WALL HUNG IiEMS WCLUDWG MILLWORK, WALLSiOPS, CABWHRY, HC. 14. SHOPDRAWINGS:SHOPDRAWWGSORCATALOGCl1TSMl1STBE BMIiiEDi H iiDEl NIN F RAPPR VAL NALLMAiERIA SU OSC O SG , C. O O O LS OR IiEMS WHERE iHE CONiRACiOR CHOOSES i0 DEVIAiE FROM WHAi IS SHOW N ON THE DRAW INGS, OR IF THE DRAW INGS DO NOT INDICATEA SPECIFlC MANUFAQURER OR MODEL NUMBER. EXPEDIiE PREPARAiION AN D SUBMIiiAL OF ALL SHOP DRAW INGS i0 ALLO W SUFFICIENi iIME FOR CHECKING, APPROVAL ORDERING, FABRICAiION, AND DELNERY OF MATERIALS AND EQUIPMENT. I5. PROJECiAPPROVALS:ALLDEiAILS,MAiERIALS,ANDINSiALUiIONS ARESUBJECi i0 RRSi APPROVAL BY SCHOii DESIGN, INC., AND RNAL APPROVAL BV TH E OW NER. 16. CHANGEORDERS:REVIEWANDCOORDINAiEALLNEWWORKAND EXISiING CONDIiIONS WIiH ALL OiHER iRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BEAPPROVED FOR ANV CONDITIONS OR CONFLICiS iHAi COULD HAVE BEEN ACCOUMED FOR BV iHE BIDDER DURING PRE-BID FIELD INSPECiION AND AFiER AWARD OF CONiRACi. V. FURNIiUREANDEOUIPMENiEXCLUSIONSFURNITUREOFFlCE EQUIPMENi, OFFlCE PARiIiION SVAENS, REFRIGERAiORS. VENDWG MACHINES, AND OiHER SIMILAR IiEMS SHOW N DASHED ON iHIS DRAW ING AND NOi AiiACHED i0 iHE BUILDING ARE FOR REFERENCE ONLY AND ARENOTTO BEPROVIDED AS PARTOFTHE WORK 11NLESS SPECIRCALLV SiAiED i0 BE PROVIDED. I8. WALL PAiCHING: PAiCH ALL GYPSUM WALLBOARD Ai AREAS OF ELECTRICAL DATA AND SW ITCH DEVICES BEWG REMOVED. PATCH HOLE RELEASED FOR CONSTRACTION `RE FOR F'"'S"- Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V`iiY?A�i \ onrE: 12/31/19 19. CONSiRUCiIONCLEANING:EXECUiEAiHOROUGHFINALCLEAN AND INSPECTION OF THESPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXiURES, AND EQUIPMENi SHALL BE CLEAN, AND iH E SPACE SHALL BE iURNED OVER i0 iHE OW NER IN A CONDIiION iHAi REPRESENiS iHEHIGHESi LEVR OF CAREAND PROFESSIONALISM. ENSUREALL GENERAL CONTRACTOR INSTALLED APPLIANCES W ORK & DO NOT LEAK_ 20. O 8 M MAiERIALS: PROVIDE i0 iH E OW NER ALL OPERAiION AND/OR MAINiENANCE MAN UALS, OR INSiRUCiIONS FOR ALL EQUIPMENi AND SVSTEMS AT TH E COMPLETION OF THE PROJECT. 2L PLANDIMENSIONS:ALLPLANDIMENSIONSAREFROMFACEOF EXISiING FINISH i0 FACE OF NEW GYPSUM BOARD WALL, OR FACE i0 FACE OF NEW GVPSl1M BOARD WALL DO NOT SCALE DRAWINGS. WRIiiEN DIMENSIONS GOVERN_ 22. WINDOW BLINDS: CONiRACiOR i0 PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACEANV DAMAGED OR MISSWG WINDOW BIJNDS WIiH NEW i0 MAiCH BUILDWGAANDARD_ 23. PERMIIIING: iHE GENERAL CONiRACiOR SHALL BE RESPONSIBLE FOR VERIFYINGiHE REQUIREMENiS REGARDING LOCAL PLAN REVIEW, PERMIiS, INSPECTIONS, AND FEES. THE GEN ERAL CONTRACTOR SHALL BE RESPONSIBLE f-0R SUBMIiiWG ALL REpUIRED DRAW WGS AND SUPPORiING DOCUMENiS i0 iHE LOCAL BUILDI NG OFFlCIAL AND/OR PERMIT DEPARTMENT. ALL REQl11RED LOCAL PERMIT FEES SHALL BE PAID BV iHEGENERAL CONiRACiOR UNLESS AIPULAiED OiHERWISHN iHE OW NER/CONiRACiOR AGREEMENi. 24. FBESEALINGRRESEALALLPENETRATIONSTHROUGHRATEDWALLS, FLOORS. AND CHLWGS WIiH APPROVED FlRE-RAiED CAULK AS DIRECiED BY LOCAL JURISDIQIONS. CONiRAQOR i0 BE AWARE iHAi EXISiWG CONDIiIONS ARE NOi NECESSARILY AN INDICAiOR OF BUILDINGiYPE. BUILDWGiVPE IJAED ON LIFESAFHV PLAN IS BASED UPON AVAILABLE INFORMAiION AND FIELD VERIFlCAiION. 25. WALLPENEiRAilON3: WHERESiRUCiURAL BEAM& DUQWORK, HC. PENETRATESOUND OR HRERATED PARTITIONS, GVPSUM WALLBOARD WALL i0 BE SCRIBE9 i0 Fli iIGHi, CAULKED AND FlRE DAMPERED IF REQUIRED. 26. FLOORLEVELING:CONTRACTORTOALLOWFORl1NLEVELFLOOR CONDIiIONS_ ALL E%IAWG FLOOR AND WALLSUBARAiES SHALL BE LEVELED AND PAiCHED AS REpUIRED i0 RECEIVE NEW CONSiRUQION AND RN ISHES. ADJUST DOORS AND FRAMES AS R EQUIRED. 2J. REPAIR GYPSOM WALLBOARD: REPAIR GVPSl1M WALLBOARD WHERE DEMOLIiIONHASOCNRREDAiREMAINWGWALLS. REPAIRANY GYPSUM BOARD DAMAGED BY DEMOLIiION. PROVIDE EXPANSION JOINTS IN DRVWALL W HERE NEW WALLS MEET OR ADJOIN TO E%ISTING CORE WALLS. 28. EOUIPMENiINSiALLAiION:ALLEQUIPMENiAND/ORFIXiURESSHALL BE INSTALLED IN STRICTACCORDANCE W ITH THE MANUFACTURERS RECOMMENDATIONS OR INSTRUCTIONS- FINISH NOTES L SiAiE BUILDING COMPLIANCE FOR FINISHES: ALL FINISHES SHALL COMPLVWITHCHAPTERB �IMERIORRNISHES�OFTHHNDIANABl11LDING CODE FORCLASSAFIRERAiWGS. 2. GYPSUMASSOCIAiIONCONFORMItt:FORALLNEWDRYWALL WSTALLATIONS WSTALL AS RECOMMENDED BV THE GVPSl1M ASSOCIATION �SUCH AS, CONiROL JOINiS, FINISH LEVELS, FASiENERS, iAPWG DEiAILS, CORNER BEADS EfQ�. PROVIDE NEW CEMENT BACKER BOARD AS A SUBSiRAiE FOR NEW WALL iILE PER MANUFAQURER'S RECOMMENDAiIONS. 3. COVER PLAiES: REFERENCE RERECiED CEILING PLAN AND ELECiRICAL PLAN FOR COLOR OF ELECTRICALAND DATA DEVICESAND PLATES. REMOV E ALL PLAiES BEFORE PAI Ni WG AND REWAALL AFiERW ARD. CONiRACiOR i0 CONFIRM DESIRED COLOR PRIOR i0 PURCHASING NEW. 4. PAINiING:ALLAREASRECEIVINGPAINTARETORECEIVE PRIMERCOAT AND iW0 �2) FINISH COAiS. 5. FLOORING iRANSIiION SiRIP4 FOR CHANGE W FLOOR FlN6H MATERIAL PROV IDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN UNLESS NOiED OiHERWISE �I.E. WHERE vCi MEEiS CARPEi�. 6. DELNERV OF COMPREHENSNE WORK PRODUCi: WHERE LIMITS OF WORK ARESHOWN, OiHER INCIDENiAL WORK IJKE PAINiWG WHERE NEW OUiLHS HAVE BEEN WSiALLED, IS CONSIDERED PARi OF iHE SCOPE OF WORK. PROVIDEACOMPLHEANDFlN6HED PRODUCiREADYFORiENANiAND Bl11LDING OWNER. ]. WALL�EMOLIiION:REFINISHSURFACESiOMAiCHEXISiWGWHERE DEMOLIiION HAS OCCURRED. REPAIR GYPSUM WALLBOARD WHERE DEMOLITIONHASOCCURREDATREMAININGWALLS. REPAIRANVGVPSUM BOARD DAMAGED BY DEMOLIiION. PROVIDE EXPANSION JOINiS IN DRYWALL W HERE NEW WALLS MEEi OR ADJOIN i0 EXISiING CORE WALLS. 8. PHONE BOARDS: WHERE PHONE BOARD IS PROVIDED, PAINT BOARD W ITH FlRE RETARDANT PAINT TO MATCH ADJACENT WALL FlNISH. 9. MILLWORKSAMPLES:SUBMIiRNISHSAMPLEOFMILLWORK�SiAWEDOR PAIMED AS SPECIFlED) i0 SCHOii DESIGN FOR REVIE W AN D APPROVAL PRIOR i0 iHE FINISHING PROCESS OF ALL MILLW ORK. 10. INiERIOR ELEVAiION DEiAIIS: REFERENCE INTERIOR ELEVATION & SECTIONS W HERE PROV IDED FOR ADDITIONAL FlNISH W FORMATION. IL PAINiBA�HE5IVEVOCS:ALLPAINiSANDADHESIVES/SEALANiSSHALL HAVE ZERO vOC CONiENi. 12 ADHESNEMANOFAQORERRECOMMENDAilONS:ALL ADHESIV ES/SEALANiS i0 BE USED AS RECOMMENDED BY PRODUQ MANUFACiURER. EFFECTIVE CODES GENERALADMINISTRATNE RULES �6]51AC 12) I NDIANA BUILDW G CODE, 2014 EDIiION �IBC, 2012 EDIiION, 6]51AC 13-26) HANDICAPPED ACCESSIBILIiV CODE_ 20141NDIANA BUILDWG CODE CHAPiER I I, ANSI AI pJ-2009, 6]51AC I&2.6-12) IN DIANA FlRE CODE, 2014 EDIiION �IFC 2012 EDIiION, 6]51AC 22-25) INDIANA PLUMBING CODE 2006 EDIiION �6I51AC 16-1.4) INDIANA ELEQRICAL CODE, 2009 EDIiION �2008 NFPA ]0, 6]51AC V-I.B) INDIANA MECHANICAL CODE, 2014 EDIiION �IMC, 2012 EDIiION, 675 IAC I&Ib) ENERGY CONSERVAiION CODE, 2010 �ASHREA 90.1, 2007 EDIiION, 6IS IAC 19.3) MECHANICAL & ELECTRICAL NOTES I. M/E/P: iHE MECHANICAL ELECiRICAL AND PLUMBINGSCOPES OF WORK ARE LIMITED TO BASIC DESIGN-Bl11LD ALTERATIONS WHICH ARE OUiLINED IN iHESE PUNS. iHE DESIGN-BUILD CONiRAQORS FOR EACH iRADE MUSi NOiIFY iHE ARCHIiECi IF iHEY FIND iHAi iHE SCOPE OF WORK EXCEEDS iHE LEVEL OF MECHANICAL ELECiRICAL OR PLUMBING WORK INDICAiED ON iHESE DRAW WGS SO iHAi ANV NECESSARV ENGIN EERING CAN OCCUR AND ADDIiIONAL PLANS CAN BE FILED, OR IF ADDIiIONAL WFORMAiION b NEEDED IN ORDER i0 COMPLHE iHE W ORK IN TH E RELD. STATE BUILDING CODE TH E CONTRACTOR�S) SHALL PROVIDE DESIGN/Bl11LD DRAWINGS FOR MECHANICAL PWMBING, ELECTRICAL ORFIRESUPPRESSION. DRAWWGSSHALLBECERiIFIEDBYALICENSED ENGW EER AND SUBMIiiED BY iHE CONiRACiOR FOR SiAiE DESIGN REVIEw. 24. EQOIPMENiINSiALLAilONS:ALLEQl11PMENTAND/ORFl%Tl1RES SHALL BE INAALLED IN ARICi ACCORDANCE WIiH iHE MANUFACiURER'S RECOMMENDAiIONS OR INSiRUCiIONS. 2 HVAC: MECHANICAL WORK IS LIMIiED i0A DESIGN-BUILD SCOPE AND IS OUiLINE9IN iHESE DRAWINGS. NO NEW MAIN MECHANICAL APPIJANCES OR MAW EQUIPMENTARE BEING PROVIDED. ALL MECHANICAL W ORK IS LIMIiED i0 RELOCAiION OF DIFFUSERS AND FLE% DUCi PER NEW WALL LAYOUi. MECHANICAL CONiRACiOR 6 i0 NOiIFY APPIJCABLE PARTIES IFADDITIONAL W ORK IS REQUIREDSO THAT ADDIiIONAL PLANS CAN BE FlLED AN D MUA COMPLV W IiH iHE INDIANA MECHANICAL CODE AND ALL OiH ER APPLICABLE CODES. 3. HVACHEAiLOADS:VERIFYHEAiLOAPSOFANYSPEQAL EQUIPMENT IN THE TENANT SPACE AND PROVIDE ADDITIONAL AIR FLOW IF REpUIRE0. CONFIRM W IiH O W NER PRIOR i0 ANY PURCHASE OF NEW EQUIPMENi. REVISE ZONING IF REQUIRED. CONiRACiOR i0 ENSURE THAT ALL HVAC ZON ES ARE LOCATED APPROPRIATELV Sl1CH THAT NO SPLIi ZONES ARE IN OFFlCES OR CON FERENCE ROOMS UNLESS APPROVED BY BUILDING OW NER/LANDLORD. 4. HVAC DIFFUSER LOCAiIONS: RELOCATEAIRSUPPLV DIFFUSERSAND RHURN-AIRGPoLLESASREQUIRED_ PROVIDEPROPERAIRSUPPLVFOR DIFFUSERS AND REiURN AIR FROM REiURN AIR GRILLES. CONiRACiOR SHALL PLACEDIFFUSERS AND RHURN AIR GRILLES AS REQUIRED BY CODE. 5. HVAC iHERMOSiAi LOCAilONS: POSIiION ALLiHERMOSiAiS WHEREAPPROPRIAiE PER MECHANICAL DESIGN. COORDINAiE WIiH TENANT AND Bl11LDING OW NER FOR Fl1RNITl1RE PANEL OR OTH ER CONFLIQS. 6. ELECiRICAL: ELECiRICAL WORK IS LIMIiED i0A DESIGN-BUILD SCOPEAND IS OUTIJNED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMIiED i0 ADDIiIONS OR RELOCAiIONS OF ELECiRICAL OUiLH DEVICES AND LIGHiWG iHAi DO NOi EXCEED iHE CAPAQiY OF iHE EXISTING ELECTRICALSERVICE IN THE BUILDING. ELECTRICAL CONiRACiOR IS i0 NOiIFV APPIJCABLE PARiI ES IF ADDIiIONAL W ORK IS REQUIRED SO iHAi ADDIiIONAL PLANS CAN BE FlLED AND MUSi COMPLY W IiH ALL APPLICABLE CODES. ]. ELECiRICALCODECOMPLIANCE:COMPLYWIiHiHEINDIANA ELECTRICAL AN D MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 8. ELECiRICALCIRCUIiING:SIZEANDQRCUIiELECiRICALPOWER ITEMS. PROVIDEORREUSEELECTRICALPOWERANDDATAOUTLETSAS REQUIRED_ 9. GFCIOUiLEiS:ALLELEQRICALOUiLEiSWIiHIN6'-0"OFWAiERARE i0 BE GFQ. 10. PHONEANDDAiAACCOMMODAilONS:ATEACHPHONE/DATA JACK, PROVIDE PULL SiRING FROM ABOVE CEILING i0 BOX. iENANi'S DAiA CONiRACiOR IS RESPONSIBLE FOR PULLING CONDUCiORS AND PROV IDING APPROPRIATE TERMINALS AT FACE PLATE. IL ELECiRICALSWIiCHPLAiES:PROVIDECOLOREDFACEPLAiESFOR ELEORICAL OUiLEiS & SWIiCH PLAiES i0 MAiCH EXISiING, UNLESS OTHERWISENOTED. ELECTRICIANTOFlELDVERIFVPRIORTOPURCHASE. 12 WORKSiAiIONPOWER:PROVIDEJUNCilONBO%ESORPOWER POLES Ai WORKSiAiIONS W HERE SHOW N. REFER i0 iHE PLAN FOR iHE APPROPRIATE DESIGNATIONS. DATA W ILL BE R UN BV THE TENANTS DATA VENDOR ELECTRICIAN TO MAKE FlNAL CONNECTION FROM WORKSiAiION W HIP i0 JUNQION BOX. iHE FURNIiURE VENDOR IS RESPONSIBLE f-0R W IRING iH E BASE PANELS OF iHE W ORKSiAiIONS. CONTRACTOR TO COORDINATE W ITH TENANT ON W ORKSTATION FURNIiURE SPECIFlCAiIONS i0 OBiAW CIRNIiRY REQUIREMENiS PRIOR i0 RUNNING ELECiRICAL CONDUIiS i0 JUNCiION BOXES. FIRE PROTECTION NOTES I. FIRE EXiINGUI5HER5: CONTRACTOR TO ENSUREALL NEW AND E%ISTING RRE E%TINGl11SH ERS ARE INSTALLE9 ACCORDING TO NFPA 10. COORDINAiE WIiH OWNER/LANDLORDON E%iWGUISHERiVPEAND HOUSING. MAXIMUM iRAVEL DISiANCE OF ]5 FEH FROM ANY POINi TO A VISIBLE E%TINGl11SHER. iHE FOLLOW WG NOiES APPLY ONLY IN EXIAWG SPRINKLERED FACILIiIES. 2. OESIGN BUILO FIRE PROiECiION SYSiEM: FIRE PROiECiION WORK IS TO BE PROVIDED BV DESIGN/BUILDSERVICES UNDER THE GENERAL CONiRACL PROVIDEACOMPLHE WORKWGSVAEM_ SCHOii DESIGN, WC.IS NOi RESPONSIBLE FOR iHE DESIGN, INSiALLAiION, OR RENOVAiION OF iH E RRESPRINKLER SYSiEM. 3. FIREPROiECilON5Y5iEMCODECOMPLIANCE:THEDESIGN/Bl11LD CONiRAQOR SHALL COMPLY WIiH iHE INDIANA BUILDWG CODE, iHE INDIANA RRECODE AND ALLOiHER APPIJCABLE LAWS, CODES, RULES AND REGl1LATIONS THATAPPLVTO DESIGN AND WSTALLATION OF FlRE SPRWKLER/FlRESUPPRESSION SVAEMS- 4. FIRE PROiECiION DESIGN DRAWINGS: iHE FIRE PROiECiION CONTRACTOR SHALL GENERATEALL REQUIRED DRAW INGS, AND SHALL FlLE iHOSE DRAW WGS. AND RELAiED DONMEMS. W IiH iHE SiAiE AND LOCAL AUiHORIiIES HAVING JURISDICiION OVER iHE PROJECi. 5. SPRINKLERHEADS:PROVIDENEWORRELOCATEE%ISTING SPRINKLERHEADSASREQUIRE0. PROVIDEMISSWG COVER/ESCUiCHEON PLAiES FORSPRINKLER HEADS WHERE APPLICABLE FlELDVERIFVE%ISTINGCONDITIONSPRIORTOTHESTART OF W ORK. MILL/CASEWORK NOTES I A EW RK MILL RK: A EW RK AND MILLW RK ENERALLY C 5 O/ O C S O O G INDICAiED ON iHESE DRAWINGS ARE i0 BE PROVIDED UNDER iHE GENERAL CONTRACT. 2 AWICOMPLIANCE:l1NLESSINDICATEDOTHERWISECOMPLV WIiH ARCHIiECiURAL WOODWORK INSiIiUiE �A.W.I.) CURRENi STANDARDS FOR CUSTOM GRADE WOODWORK. 3- MILLWORK SHOP DRAWINGS FURNISH SHOP DRAW WGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY iHE iENANi AND SCHOTf DESIGN PRIOR TO FABRICATION. 4. MILLWORKFIELDVERIFICAiION:WHERECASEWORKAND MILLWORK ARE i0 BE INSiALLED, vERIFY ALL DIMENSIONS ON PLANS AGAINSTDIMENSIONSOFAS-BUILTCONDITIONSWRELD. REPORT ANV DISCREPANCIES i0 SCHOii DESIGN iHROUGH iHE GENERAL CONiRAQOR. MAKEADJUSiMENiSiOCASEWORKANDMILLWORK i0 Ri RRD CONDIiIONS UNLESS DOINGSO WILLSIGMRCANiLY ALTERTHHMENTOFTHEDESIGN SHOWN ON THEDRAWINGS. 5. DRAWING REVIEW AND �ISCREPANCIES: VERIFY FINISHES �LAMINATE VENEER,STAINS EfC.) ON THESECTIONSAND ELEVATION DRAW WGS W IiH FlNISHES INDICAiED ON iHE FNISH PLAN/SCHEDULES. IMMEDIAiELY REPORi ANY DISCREPANCIES i0 SCHOii DESIGN iHROUGH iHE GENERAL CONiRACiOR. 13. LIGHiINGCIRCUliS:VERIFVEXISTINGLIGHTINGCIRCUITING;SIZE 6. MILLWORKREQOIREMENiS:REFERTOMILLWORKSECTIONS& NEWCIRCUIiSASREQUIRED_PROVIDENEWORREVISEE%IAWG ELEVAiIONS.UNLESSOiHERWISESHOWN,PUSiICLAMINAiECUD CIRCUIiING FOR NEW LAYOUi OF LIGHi FIXiURES. COUNiERiOPS WIiH 4" BACKSPLASH WHERE INDICAiED, BACKSPLASH TO BE FlELD APPLIED. REFER TO MILLW ORK SECTIONS & ELEVATIONS 14. ELECiRICAL OUiLETS: ENSUREiHAi ALL MOUNiING HEIGHiS OF FOR CABINEiRY SPEQFICAiIONS �CUSiOM PLASiIC LAMINAiE OR ELECTRICALDEVICESMEEfADAREQUIREMENTS- PRE-MANl1FACTl1REDSTOCKCABWEfRV�. EDGESOFPLASTIC LAMI NAiE COUMERiOPS, CABW HS AND DRAW ERS i0 BE PLAAIC I5. LIGHiINGSWIiCHPLAiES:WHEREMULiIPLESWIiCHESARESHOWN, �AMINAiEANDNOiPVCOROiHERSiOCKPLASiICEDGINGUNLESS PROVIDE�I�GANGBOXWITHASINGLECOVERPLATE NOTEDOTHERWISE. 16- FIXiURE PLACEMENi: CEMER CEILWG ELEMEMS IN CEILWG iILES. �- MILLWORK WALL BLOCKING: PROVIDE BLOCKWG IN WALLS FOR WCLUDINGRECESSEDDOWNLIGHiS,SMOKEDEiECiORS,SPRINKLER A��MILLWORK,WALLSiOPS,HARDWARE,ANDCABINEiRYWHERE HEADS, AND EXITSIGNS 11NLESS OTHERWISE NOTED. SPECIFlED. ALL WOOD BLOCKINGTO BE FlRE RATED. I]. EMERGENCY LIGHiING: PROVIDE EMERGENCV LIGHiWG IN iENANi SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BAiiERY PACKS OR LIGHiS CONN ECiED i0 AN EMERGENCY POW ER SOURCE ARE REQl11RED IF THE SPACE CONTAINS 50 PERSONS OR MORE Fl%Tl1RES SHOW N ON PUN ARE FOR REFERENCE ONLY. I8. FIREALARMSVSiEM:FlRESUPPRESSIONANDFlREALARMSYSiEMS SHALL BE INSTALLED BV THE APPROPRIATE DESIGN-Bl11LD CONTRACTOR AND MUA COMPLY W IiH ALL APPIJCABLE SiAiE AND LOCAL BUILDW G CODES. RRESUPPRESSION AND RREALARM DESIGN-BUILD �oNrRA�ro�ARERESPONs�B�E�R�oMP�Er�N�ANOF���N�r�E�R DOCUMENT APPROVAL PLAN AND BTAININ THEIRPERMIT.PR VIDEALARMN TIFl ATI N S O G S O O C O APPLIANC ES �HORNS/SiROBES�, EMERGENCY SPEAKERS, SMOKE DETECTORS RRE Pl1LLS, AND ANV OTHER REQIII RED ALARM & DECONSTRUCTION NOTES I. DECONSiROCiIONDEFINIiION:CAREFl1LLVDISMAMLESPACES W IiH iH E GOAL OF MA%IMIZW G iHE REUSE POiENiIAL OF IiS COMPONENiS. 2. RECVCLING: GENERAL CONiRACiOR 6 RESPONSIBLE FOR RECVCIJNG OF ALL CARPH AND MHALS Ai A MINIMUM, AND COORDINAiING iHE APPROPRIAiE HAULING CONiAINERS W IiH iHE WASiE MANAGEMENi SUB-CONiRACiOR AND KRUSE CARPH RECVCLING. REFERTODECONSTRl1CTIONDIIISHEETFORSPECIFlC INSiRUQIONS. 3. EXISiINGSiRUCiURALELEMENiSOFBUIL0ING:NOSiRUCiURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESUQ OFiH1S PROJECi UNLESS SPEQFlCALLYNOiEDOiHERWISEONiHEDRAWINGS. PROiECiALL EXISTINGSTRUCTURALMEMBERS DURING DEMOIJiION/CONARUCiION_ iHE CONiRACiOR SHALL V EPoFV IN iHE FIELD, PRIOR i0 DEMOLIiION, iHAi ALL IiEMS NOiED i0 BE DEMOIJSHEDARENOiSiRUCiURAL CONiACiSCHOiiDESIGN IMMEDIAiELY IF iHE CONiRAQOR�S) IN iH E FIELD SUSPEQ iHAi AN IiEM NOiED FOR DEMOLIiION APPEARS i0 BESiRUCiURAL OR OTHERWISELOAD-BEARING. BEWAREOFSTRUCTURALCOWMNS AND/OR BEANS iHAi MAV BE CONCEALED BEHIND FlNISHE$ iHAi ARE NOiED FOR REMOVAL EXERCISE CAUiION WHEN DEMOLISHING BUILDING RNISHES OR PARiIiIONS ADJACENi i0 OR AROUND STRUCTURAL MEMBERS- THE CONTRACTOR IS SOLELV RESPONSIBLE FOR INADVERiENi DAMAGE i0 iHE BUILDING SiRUCiURAL SYSiEM. 4. EOUIPMENi, FIXiURE, FINISH RE�USE: WHERE EQUIPMENL FlXiURES OR RNISHES ARE MOV ED FROM ANV OTH ER PART OF TH E Bl11LDING TO BE REUSED IN iHE PROJEQ AREA, iHE CONiRACiOR SHALL WCLUDE IN iHEIR SCOPE OF WORK ANY NECESSARY PAiCHING OR REPAIRING OF TH E REMAINING AREAS FROM W H ERE TH E ITEMS W ERE RELOCATED, UNLESS OiHERW ISE DIRECiED BY OWNER. 5. DECONSiRUCiIONPLANS:REMOVEALLEXISiINGWALLSAND DOORS WHERHNDICATED BV NOTE SVMBOL OR DASHE9 LWES. NOiE iHAi SOME IiEMS HAVE NOi BEEN SHOWN ON DECONSiRUQION PUN. VISIi AREA OF WORK i0 ASSURE EXiENi OF DECONSiRUCiION. 6. FIELD VERIFICAiION OF EXISiING CONDIilONS: REMOVEALL CARPEi, VINYL BASE, VQ, WALL FABRIC, AND ANY OiHER FINISHES AS REQUIRED FOR NEW CONSiRUCiION. CONiRACiOR i0 FlELD VERIFY E%ISTINGCONDITIONS. REFERTOFlNISHPLAN/SCHEDl1LEFOR CLAPoFlCAiION OF E%IAWG FlNISHES i0 REMAIN_ ]. PROiECiION OF BUILDING ELEMENiS i0 REMAIN: USE CARE i0 PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS i0 REMAW SUCH AS. BUi NIN LIMIiED i0. E%IAWG CEILWG GRID, iILES, FIRE SUPPRESSION EOUIPMENi, DIFFUSERS, LIGHi FIXiURES, W EQUIPMENLCASE ORKANDFlN6HES. iHECONiRACiORSHALL REPLACE AND/OR REPAIR AT TH E CONTRACTOR'S COST, ANV Sl1CH ELEMENiS DAMAGED DURWG CONSiRUQION iHAi COULD HAVE OiHER W6E BEEN REASONABLY PROiECiED AND MAINiAWED IN GOOD CONDITION FOR TH E OW NER'S 11SE IN TH E PROJECT. 8. REMOVALOFABAN�ONEDCABLINGBWIRING:PERiHEINDIANA ELECiRICAL CODE �SPREAD OF FlR E OR PRODUCiS OF COMBUSiION) REMOVE ALL ACCESSIBLE PORiIONS OF ABANDON ED CABLES AND WIRWG WCLUDWG BUi NOi IJMIiED iO-DAiA WIRWG, COMMUNICAiIONS WIRING, HREALARM CABLES, AUDIO CABLES, COA%IAL CABLES, FlBER OPTIC CABLES/RACEWAVS, AND PLTC CABLES. REFERiOSECilON300.2LANYSUCHCABLEORWIRWG SHOULD BE PULLED AND REMOVED BACK i0 iHEIR MAIN SOURCES ON THE FLOOR (I E ELECTRICAL PANELS. PHONE BOARDS ETC-) 9. PROiECiIONOFABANDONED/iERMINAiEDBUILDING5Y5iEM ELEMENTS: WHERE FlXrURES OR EQUIPMENT ARE REMOVED FROM ANV ELECiRICAL PLUMBWG. MECHANICAL OR VOICE/DAiA SVAEMS. ALL REMAINWG iERMINAiIONS SHALL BE CLOSED AND PROiEQED IN SiRIQ ACCORDANCE W IiH INDUSiRY SiANDARRS AND GOVERNING SAFEfV REGl1LATIONS OR PROCEDl1RES. MARK, LABEL OR FLAG ALL iERMINAiEDSYSiEMSFORFUiUREREFERENCE CONiRAQORiO PROV IDE AN "AS-BUILi" SH INDICAiING iH E LOCAiION OF ALL PERMAN ENTLV ABANDONED SVSTEMS. 10- HAZARDOUSMAiERIALS-GENERALCONiRACiOR IS RESPONSIBLE FOR IDENiIFYING ANY AND ALL IiEMS iHAi MAY CONiAIN HAURDOUS OR HARMFUL MAiERIALS. ALL IDENiIRED IiEMS MUST BE PROPERLV DISPOSED OF PER EPA AND INDIANA DEPARTMENT OF ENVIRONMENiAL MANAGEMENi RULES AND REGULAiIONS. oerecnoNsysremsnsNecessnevroMeernunPPucna�ecooes TENANT/CLIENT,UPONSIGNATURE,APPROVESALLASPECTSOFTHESCOPEOFWORKCONTAWEDINTHESE �INTERNATIONALBUILDINGCODEINTERNATIONALFlRECODENFPA�. DOCUMENTS. 19. FIRE ALARM DEVICE LOCAilONS: COORDINAiE WIiH OWNER/iENANi PRIOR iOINSiALLAiION OF FIRE DEiEQION DEVICES REGARDINGALLDEVICELOCAiIONSiOAVOIDCONFLICiWIiH iENANi/CLIEMCOMPANVNAME DAiE FEAiURE WALL$ �CONFERENCE ROOMS AND RECEPiION AREAS) AND iENANi-INSiALLED IiEMS �LE PRESENiAiION BOARPS, AN EQUIPMENi AND PROJEQION SCREENSf. FAILUREiO DOSO MAY RESULi IN CONiRACiORRELOCAiINGiHESEIiEMSAiiHEIREXPENSE. iENANiREPRESENiAiIVESIGNAiURE iENANiREPRESENiAiIVEPRINiEDNAME 20. EXISiINGLIGHiFIXiUREREIAMP:IFREQUIRED,ANDASNECESSARV, q��COSiSWCURREDDUEiOANYCHANGESREQUESiEDAFiERSIGN-OFFOFiHESEDOCUMENiSSHALLBEiHEFULLRESPONSIBILIiYOFiHE PROVIDENEWBALLAASANDLAMPSINALWGHiSWE%IAWGSPACES_ TENANT/CLIENT. CONSULi WIiH LANDLORD. 21. HVACCONiRACiORAIRBAIANCE:CONTRACTORTOPERFORMAIR BALANCE UPON COMPLHION OF HVAC SCOPE PROVIDE REPORi i0 LANDLORD. 22. HVACFLEXDUCEFLEXDUCTMUSTMEEfASHRAESTANDARD Bl11LDING CODES FOR FLIX Dl1CT LENGTH. 23. ENGMEERE�MEP�RAWINGS:iHEMECHANICAL,ELEQRICALAND PLUMBING DESIGN-BUILD COMRACiORS SHALL COMPLY WIiH ALL APPLICABLE STATE AND LOCAL Bl11LDING CODES. W HEN REQIII RED BV iHESE DRAW WGS. AND iHE IDEAS. DESIGNS AND CONCEPiS CONiAWED HEREIN, ARE iHE E%CLUSNE IMELLECiUAL PROPERiV OF SCHOii DESIGN, WC., AND ARE NOi i0 BE USED OR REPRODUCED IN W HOLE, OR IN PARi, WIiHOUi iHE W RIiiEN CONSENi OF SCHOii DESIGN. s�...pm v1 s - �limirvr., - _ �.vi...�.si c..�,�o.�.�u �.. � VICINITY MAP NOT TO SCALE KEY PLAN - 2ND FLOOR � NOT TO SCALE � INDEX OF DRAWINGS illl COVERSHEHANDGENERALPROJECiNOiES LI00 LIFE SAFEiY PLAN All I DECONSTRUCTION PLAN I ARCHITECTURAL ELECTRICAL&RNISH PLAN AI21 REFLECiE9CEWNGPLANI DOORSCHEDULEIIMERIORDHAILS �i � � •� o � � J � N b O J � Q o � JJ �nZ� - r ^ y m J � .� � . P Qn 7 w p � n O C `n O p 3 � 0 3 C iHl$ DRA W ING. AND iH E IDEAS. DESIGNS AND CONCEPiS CONiA W ED HeeeiN. neerHe Excwsive INiELLKiUAL PROPERiY OF $CHOii DFIGN. WC..ANDARENOiiO BE USED OR REPRODUCED IN W HOLE OR IN PARi, wIiHOUi iHf wRIIIfN CONSENi OF SCHOII DESIGN. • OO � V" W � J � QN � N U� � N O Q � 5Z Z L W a 2 J J �<.�..� VN < � Z Z Q Qw U � ZZ Wr � ^ Wr 2 r ISSUE DAiE DESCRIPiION 11.1].19 PERMIiSEi 1].6.19 REVIEW SEi REVISIONS MAR DAiE DB DESCRIPiION I� �. neimaoan STATE OF PROJECT NUMBER 2019.344 PROJ. MGR DRAWN BY ACM ACM/CRB 2ND FLOOR COVER SHEET AND GENERAL NOTES T111