HomeMy WebLinkAboutA00.10 - GENERAL NOTES AND TYPICAL MOUNTING HEIGHTSRELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
of Sla�e antl Local Codes
City of Carmel
�I
`��¢m�' lamn�Ml1 �
onrE: 12/31/19
GRAPHIC SYMBOLS
POW ER AND COM MUNICATION
�g
WALL MOUNTED DUPLEX
N,y,
WALL MOUNTED DEDICATED DUPLEX
W WALL MOUNTED SEPARATE DUPLEX
� WALL MOUNTED FOURPLEX
��y WALL MOUNTED DEDICATED FOURPLEX
�y WALL MOUNTED HALF DEDICATED FOURPLEX
� WALLMOUNTEDTELE/DATASINGLEDROP
� WALL MOUNTED DATA RECEPTACLE
0 WALLMOUNTEDTELE/DATADUALDROP
An� WALLMOUNTEDNVTROUGH
y WALL MOUNTED NV RECEPTACLE
4 WALLMOUNTEDCABLENRECEPTAQE
� WALL MOUNTED VOICE/DATAJUNCTION BOX
Q WALL MOUNTED ELECTRICAL JUNCTION BOX
4 WALL MOUNTED SYSTEMS PANEL VOICE/DATA WFEED
� WALL MOUNTED SVSTEMS PANEL POWER INFEED
P
• POWERPOLE
� EpUIPMENT,POWERED-SEESCHEDULE
REFLECTED CEILWG
ACOUSTICAL CEILING AND GRID
�
� PX4'LIGHTFIXTURE
�� EXISTING TO BE REMOVED
L-_-_ J
'---" UNDERCABINETLIGHTFIXTURE
�� STRIPLIGHTFlXTURE
ii ii pENDANTFlXTURE
i�______�i
`_ ` ___'
� CEILINGHEIGHTCHANGE
�CEILWG FINISH
�X - CEILWGHEIGHT
X'-X" DIMENSION OF CEILING ABOVE FlNISH FLOOR
� CEILINGMOUNTEDEXITSIGN
�I WALL MOUNTED EXIT SIGN
� RECESSEDDOWNLIGHT
'O' ADJUSTABLEDOWNLIGHT
S RECESSED WALL WASHER
v v v TRACK LIGHTING
� SURFACE MOUNTED LIGHT FlXTURE
D WALLSCONCE
Q EXHAUSTFAN
SD SMOKEDETECTOR
ST STROBE
♦ FIRE SPRINKLER
O SPEAKER
MS MOTION SENSOR
� ACCESSDOOR
� SECURITYCAMERA
O THERMOSTAT
$ LIGHTSWITCH
$D DIMMERSWITCH
� PROJECTIONSCREEN
� RETURNAIR
� SUPPLVAIR
� EXHAUST
OO CIRCULARDIFFUSER
� LWEARDIFFUSER
E DENOTESEXISTINGTOREMAIN
R DENOTES EXISTING, RELOCATED FlXTURE
OEpUIPMENT,NOTPOWERED-SEESCHEDULE
X� EpUIPMENT,POWERED-SEESCHEDULE
SECTION INDICATIONS
.T�� � .\:\ STONE
� CONCRETE
CONCRETE MASONRV UNIT
� STEEL
� ALUMINUM
PLYWOOD
� WOOD(FlNISH)
� WOODICONTINUOUS)
� WOODBLOCKING)
� INSULATION (LOOSE OR BATT)
� GLASS(LARGESCALE)
� GYPSUM BOARD
� ACOUSTICAL TILE
� CARPET
CONSTRUCTION
1 COLUMNGRID
A
�
❑ NOTINCONTRACT
� EXISTING CONSTRUCTION TO REMAIN
_ _ _ _ EXISTING CONSTRUCTION TO BE
---- DEMOLISHED
NEW PARTITION
XXX - REFERENCETOPARTITIONTYPE
� 1 HR. RATED PARTITION
� SMOKE PARTITION
OFFlCE- ROOM NAME
XXX ROOM NUMBER
XXX- DOORTVPE
}pp� - DOOR NUMBER
k## kk# HARDWARE
DOORiYPE
ALIGN
�ALIGNWITHESTABLISHEDSURFACES
1
� KEV NOTE
� REVISIONCLOUDANDTAG
XX.
- ELEVATION NUMBER ON SHEET
AXX DIRECTION OF ELEVATION
� SHEETWHERESHOWN
�XX' _
- DETAIL NUMBER
SHEET W HERE SHOW N
XX.
� n�vrvl-�":.
� 1 � � DESCRIPTIONOFSIMILAROROPPOSITE
l � �"� ROOR LEVEL AND AREA OR PHASE QF APPLIC )
� AREATOBEDETALLED
�Ld ... MILLWORK
MILLW ORK SCHEDULE TAG QF USED)
XXXX �
e FIREHOSECABINET
� FlREEXTWGUISHERWITHOUTCABWET
p FIRE EXTINGUISHER CABINET
O FIREVAWEWITHOUTCABINET
a FIRE VAWE CABINET
FA
Q FlREALARMPULL
FINISH
� WALL FINISH
� XXXx �� BASE FINISH
� EXTENTOFFINISH
' XXX ` WqLLFINISH
O SPECIAL FINISH
XXX FLOOR FINISH
XXXX CEILWGFINISH
�- CEILWG FINISH
�X CEILWG HEIGHT
� CHANGE IN FLOOR FINISH
� STARTWGPOINT
R14tlI1:i1 V�Ui�/[N4:.
CR
EH
EL
ES
DR
MS
DC
EM
KS
HO
IC
0
DD
�
IA
O
PIR
CARDREADER
ELECTRIC HWGE
ELECTRICLOCKSET
ELECTRIC STRIKE
DOOR RELEASE
DOOR RELEASE MOTION SENSOR
DOOR MONITOR CONTACT
ELECTRO-MAGNETIC LOCK
KEY SWITCH
DOOR HOLD OPEN
INTERCOM
BELL PUSH BUTTON
DOUBLE DOOR MONITOR CONTACT
REMOTEDOORRELEASEBUTTON
INTRUSION ALARM
DOOR BELL
PIR (REQUEST TO EXIT, PASSIVE
INFRARED DETECTOR) CEILWG
MOUNTED
TYPICAL MOUNTING HEIGHTS
6•
Y i
.
m
�
O
�
O
a ,
O _
O
z �
¢
v
DEVICES AT DOOR IN OPEN POSITION
�
el
�
I
w
O
O
O
________________I_I______
� � ..,'� ��� � s l/:
ti
�
� Q
�
OUTLINE OF
DOOR IN OPEN
POSITION
ALIGN TOP OF
DEVICES
� � �
, / ....:r�.i `..
- p.
- THERMOSTAT
- GANG OF DIMMER
SWITCHES
� FWORESCENT
SW ITCH (SECU RIN
DEVICE W HERE
OCCURS.I.E. CARD
READERS,ETC.)
DOORFRAME
AUDIBLE/VISIBLE STROBE
FlRE EXTINGUISHER
AND/OR HOSE CABINET
PEEP SCOPE, WHERE
SCHEDULED
HOLD UP LIGHT
ALIGN
-� I I II
� I� �I
T�I
� I
4 VY'
�........� L
THERMOSTAT LOCATION.
DONOTLOCATE
DIRECTLV ABOVE
DIMMERS.
� LOCATION FOR: LIGHT
_ SWITCH,DIMMERS,
EGRESSBUTTON,CARD
M READER,(ETC)CLUSTER.
SEE PLAN FOR �UANTITY
OF EACH CWSTER. USE
GANGNPE COVER
PLATES FOR MORE THAN
ONE DEVICE OF THE SAME
TYPE.
DEVICES AT DOOR IN CLOSED POSITION
NOTE: ALL DIMENSIONS TO CENTER LWE OF DEVICES U.N.O.; INTERCOM TO BE MOUNTED AT
3'-9" AFF UN.O.; CENTER ALL DEVICES BELOW SW ITCH. ALL OPERABLE PARTS SHALL BE
OPERABLE W ITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR
TW IST WG OF THE W RIST W ITH A MAX OF 5 LBS. OF FORCE TO OPERATE. A CLEAR SPACE TO
BE PROVIDED OF 30" MIN. X 48" MIN.
ACCESSIBILITY NOTES
1. THEAMERICANWITHDISABILITIESACT�A.D.A�PROVIDESTHATALLNEW
CONSTRUCTION FACILITIESMUSTBEBUILTINSUCHAMANNERTHAT,TOTHE
MAXIMUM EXTENT FEASIBLE, THE FACILITV IS READILV ACCESSIBLE TO INDIVIDUALS
W ITH DISABI LITIES. BANK OF AMERICA AND THE GENERAL CONTRACTOR
ACKNOW LEDGE THAT THE REpUIREMENTS OF A.D A. W I LL BE SUBJECT TO VARIOUS
ANDPOSSIBLVCONTRADICTORVINTERPRETATIONS. THEARCHITECTTHEREFORE
W ILL USE H IS/ HER BEST PROFESSIONAL EFFORTS TO INTERPRET A.D.A.
RWUIREMENTS AND OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODE
OR�INANCES AN� REGULATIONS AS THEY APPLY TO THE PROJECT. THE ARCHITECT,
HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT BANK OF
AMERICA W ILL COMPLV W ITH ALL INTERPRETATIONS OF THE A.D.A. REpUIREMENTS
AND/ OR THE REpUIREMENTS OF OTHER FEDERAL, STATE AND LOCAL LAW S, RULES,
CODES, ORDINANCES AND REGULATIONS AS THEV APPLV TO THE PROJECT.
2 FLOORSURFACESSHALLBESLIP-RESISTANT.
3 EVERVCORRIDORANDAISLESERVINGANOCCUPANTLOADOF100RMORE,SHALL
BE NOT LESS THAN 44" IN W I�TH.
4. ABRUPT CHANGES W LEVELALONG ANV ACCESSIBLE ROUTE SHALL NOT EXCEED VY'
INHEIGHT. LEVELCHANGESNOTEXCEEDINGI/4"MAVBEVERTICAL. BEVELOTHERS
W ITH A SLOPE NOT GREATER THAN 1:2.
S LATCHINGANDLOCKINGDOORSTHATAREHANDACTIVATEDANDWHICHAREINA
PATH OF TRAVEL SHALL BE OPERABLE W ITH A SI NGLE EFFORT BY LEVER. TYPE
HARDWARE, PANIC BARS, PUSH-PULL ACTIVATWG BARS, OR OTHER HARDWARE
SHALL BE DESIGNED TO PROVIDE PASSAGE W ITHOUT REpUI RING THE ABI LITY TO
GRASPTHEOPENINGHARDWARE. MOUNTDOOROPENINGHARDWAREBETWEEN34"
AND 44" AEF.
6. CENTERHAND-ACTNATEDDOOROPENINGHARDWAREBETWEEN34"AND44"AF.F.
1. MAXIMUMPULLORPUSHEFFORTTOOPERATEDOORSSHALLNOTEXCEED5POUNDS
FOR EMERIOR DOORS AND 5 POUNDS FOR IMERIOR DOORS, MEASUREDAT RIGHT
ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDWG OR FOLDING DOORS.
CORRESPONDWG DEVICES OR AUTOMATIC DOOR OPERATORS MAV BE UTILIZED TO
MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE REpUIRED FIRE
DOORS MAV BE INCREASED BUT SHOULD NOT EXCEED 15 POUNDS.
8. THEBOTTOMIO"OFALLDOORS�EXCEPTSLIDING�SHALLHAVEASMOOTH
UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BV A W HEELCHAIR
FOOTREST W ITHOUT CREATW G A TRAP OR HAZARDOUS CONDITION.
9. EVERVRWUIREDENTRANCEORPASSAGEDOORWAVSHALLNOTBELESSTHAN3'IN
W I�TH AN� NOT LESS THAN 6'-8" IN HEIGHT. �OORS SHALL BE CAPABLE OF OPENING
AT LEAST 90 DEGREES AND SHALL BE MOUNTED SO THAT THE CLEAR W IDTH OF THE
DOORWAV IS NOT LESS THAN 32".
10. WHEREAPAIROFDOORSISUTILIZED,ATLEASTONEOFTHEDOORSSHALLPROVIDE
A CLEAR, UNOBSTRUCTED OPENI NG W IDTH OF 32" W ITH THE LEAF POSITIONED AT AN
ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.
11. IDENTIFY ACCESSIBLE ENTRANCES W ITH IMERNATIONAL SVMBOL OF ACCESSIBILITV
AND WITH ADDITIONAL DIRECTIONALSIGNS, AS REpUIRED, VISIBLE FROM
APPROACHING PEDESTRIAN WAVS.
12 THE FLOOR OR LAN�WG ON EACH SI�E OF AN ENTRANCE OR PASSAGE �OOR SHALL
BELEVELANDCLEAR. THELEVELANDCLEARAREASHALLBEATLEAST60"LONGIN
THE DIRECTION OF THE DOOR SW ING AND 48" QEAR IN THE DIRECTION OPPOSITE
THE DOOR S W ING MEASURED IN RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS
CLOSED POSITION.
13. FLOORS AND LANDINGS SHALL NOT BE MORE THAN 1/2" LOWER THAN THE
THRESHOLD OF THE DOORWAV. CHANGE IN LEVEL BETWEEN il4" AND il2" SHALL BE
BEVELE� W ITH A SLOPE NO GREATER THAN t2.
14. TOALERTTHEVISUALLVIMPAIRED,MARKTHEUPPERAPPROACHANDTHELOWER
TREAD OF EACH INTERIOR STAIR W ITH A STRIP OF QEARLV CONTRASTING COLOR AT
LEAST P' W IDE PLACED PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSE OF
THE STEP OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS
SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR.
15. ELECTRICALRECEPTACLEOUTLETSONBRANCHCIRCUITSOF30AMPERESORLESS
AND COMMUNICATION SVSTEM RECEPTACLES SHALL BE MOUNTED 15" MIN. A.F.F. TO
THE BOTTOM OF THE BOXAND 48" MAX. AEE TO THE TOP OF THE BOX.
FIRE DEPARTMENT NOTES
1. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON
DRAW I NGS, AND ADDITIONAL SIGNS AS R W UIRED BV BUILDING DEPARTMENT
INSPECTORORFIREDEPARTMENTFIELDINSPECTOR. CONNECTEXITSIGNSTO
EMERGENCV POWER CIRCUITS. COMPLV W ITH BUILDING CODES.
2. MAINTAINAISLESATLEAST44"WIDEATPUBLICAREAS.
3. EVERVEXITDOORSHALLBEOPERABLEFROMTHEINSIDEWITHOUTTHEUSEOFA
KEV OR ANV SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE
OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES.
4. DOOR OPENINGS INTO REpUIRED 1-HOUR, FlRERESISTNE CORRIDORS SHALL BE
PROTECTED W ITH A SMOKE OR DRAFT STOP ASSEMBLV HAV W G A 45 MI NUTEDOOR IN
A 1 HR WALL RATWG AND SHALL BE SELF-0LOSWG.
5. 20-MI NUTE DOOR JAMBS TO BE TIGHT-FlTTING, SMOKE AND DRAFT CONTROLLED.
6. EXITDOORSSHALLSWINGINTHEDIRECTIONOFTRAVELWHENSERVINGSOORMORE
PERSONS AND IN ANY HAZARDOUS AREAS.
]. INTERIOR WALL AND CEILING FlNISHES FOR EXIT CORRIDORS SHALL NOT EXCEED AN
END POINT FLAME SPREAD RATING:
-0LASS A, FLAME SPREA� 0-25, SMOKE �ENSITV i5Q FOR MATERIALS INSTALLE� IN
VERTICAL EXITS.
-CLASS B, FLAME SPREAD 26-15, SMOKE DENSITV 30Q FOR MATERIALS INSTALLED IN
HORIZONTAL EXITS.
-0LASS Q FLAME SPREAD ]6-200, SMOKE DENSITV OF450, FOR MATERIALS INSTALLED
IN ANV OTHER LOCATION.
8. PROVIDE FlRE DAMPERS WHEREAIR DUCTS PENETRATE FlRERATED WALLS OR
CEILWGS.
9. WOODBLOCKING,CLEATS,GROUNDS,SHEATHINGANDOTHERMISCELLANEOUS
CARPENTRV ITEMS SHALL BE FlRETREATED IN ACCORDANCE W ITH APPLICABLE
CODES.
10. HEARING IMPAIRED: FLASHING VISUAL WARNINGS SHALL HAVEA FREpUENCV OF NOT
MORE THAN 60 FLASHES PER MINUTE, AND SHALL BE SVNCHRONIZED.
1t LOCATETHEHIGHESTPOINTOFTHEACTIVATINGHANDLEOFAMANUALFIREALARM
BOX A MINIMUM OF 4Y' AND A MAXIMUM OF 48" ABOVE FINISH FLOOR.
12. CONTRACTOR SHALL PERMANENTLV IDENTIFV ALL PROTECTED OPENINGS, CORRIDOR
PARTITIONS, SMOKE STOP PARTITIONS, HOPoZONTAL EXIT PARTITIONS, EXIT
ENCLOSURES ANDALL FIRE RATED WALLS WITH CORRESPONDING HOURLV RATING
BV EITHER INSTALLING SIGNS OR BV STENQLING IN CONCEALED SPACES THE
FOLLOW ING "1 HOUR FlRE AND SMOKE BARRIER - PROTECT ALL OPENINGS," NOTE
IDENTIFlCATION SHALL BE SPACED NO MORE THAN 15 FEET FROM EACH END WALL
AND THIRTV FEET ON CENTER W ITH A MINIMUM LETTER SIZE OF THREE INCHES IN
HEIGHT ON A CONTRASTWG BACKGROUN�.
13. PROJECT �OES NOT INCW�E STORAGE, �ISPENSWG OR USE OFANV FLAMMABLE OR
COMBUSTIBLE LIpUIDS, FLAMMABLE GAS OR HAZARDOUS SUBSTANCES.
14 FLOOR COVERINGS PoR CORRIDORS, LOBBIES, STAIRS AND OTHER EXIT PATHS OR
EXIT AREAS ARE SPECIFIED TO BE CLASS B OR BETTER.
15. INTERIOR WALL, CEILING TRIM AND INCIDENTAL FINISH, (OTHER THAN WALL BASE,
BULLETIN BOARDS, POSTERS AND PAPER I N ACCORDANCE W ITH FlRE CODE) SHOULD
NOT EXCEED 10 PERCENT OF THE AGGREGATE WALL AND CEILING AREAS OF ANV
ROOM ORSMALLSPACE.
GENERAL NOTES
1. ALLWORKSHALLCONFORMTOTHEAMERICANWITH�ISA8ILITIESACT(ADA.)OR
INDIANA ACCESSIBILITVSTANDARDS WHEREAPPLICABLE ALONGWITHALLSTATE
COUNiY ANDLOCALAPPLICABLECODES ORDERS ORDINANCESANDREGULATIONS.
PRIOR TO START OF WORK, NOTIFV ARCHITECT OF ANV DISCREPANCIES BETWEEN
THE DRAW INGS AND CODE ALL WORK SHALL CONPoRM TO THE MOST RESTRICTIVE
REQUIREMENTS.
2. BEFORECOMMENCINGWORK,CONTRACTORSHALLBECOMEFAMILIARWITHTHE
DRAW INGS AND THE SCOPE OF W ORK. CONTRACTOR SHALL VERIFY EXISTING
CONDITIONS AND DIMENSIONS AT THE SITE ARCHITECT SHALL BE NOTIFlED OF
DISCREPANCIES.
3. BEPoRECOMMENCINGWORK,THEGENERALCONTRACTORSHALLSUBMITAN
ITEMIZED COST BREAKDOW N OF ALL SCOPE ITEMS AND A CONSTRUCTION SCHEDULE
TOTHEBANKOFAMERICAPROJECTMANAGERANDTHEARCHITECT. WORKSHALLBE
SCHEDULED TO MEET BANK OF AMERICA REpUIREMENTS.
4. ALLWORKDESCRIBEDORINDICATEDINTHESEDOCUMENTSANDALLWORK
DEPENDENT UPON OR NECESSARY TO COMPLETE TH IS W ORK SHALL BE EXECUTED IN
A W ORKMAN-LIKE MANNER CONSISTENT W ITH THE BEST STANDARDS OF THE TRADE.
ITEMS AND MATERIALS USED SHALL BE SUITED FOR THE INTENDED PURPOSE.
5. TRHDESMEN,CRAFTSMEN,INSTALLERS,FOREMENANDSUPERVISORSARETOBE
SKILLEq EXPERIENCED AND LICENSED IF RE�UIRED IN THE WORK THEV WILL BE
PERFORMWG.
6. PROJECTCONSTRUCTIONITEMSTOBENEW,UNLESSNOTEDOTHERWISE NO
SUBSTITUTIONS W ILL BE ALLOW ED UNLESS COMPLETE DESCRIPTIONS, DRAW W GS,
TEST DATA, SAMPLES, COST AND SCHEDULED CHANGES ARE SUBMITTED BV THE
CONTRACTOR AND APPROVED BV THE ARCHITECT PRIOR TO INSTALLATION. ANV
ITEMS NOTED ON THE DRAW INGS THAT ARE NOT AVAILABLE OR W OULD CAUSE A TIME
DELAV SHALL BE IDENTIFlED BV THE GENERAL CONTRACTOR AND THE ARCHITECT
SHALL BE NOTIFlED.
]. TVPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVERAPPLIABLE UN.O.
ALL SVMBOLS AND ABBREVIATIONS USED ON THE DRAW INGS ARE CONSIDERED
CONSTRUCTION STANDARDS. IF CONTRACTOR HAS ANV QUESTIONS REGARDING THE
SAME OR EXACT MEAN WG, ARCHITECT SHALL BE NOTIFIE� FOR CLARIFICATION.
8. DIMENSIONSARETOTHEFACEOFFINISHONEXISTWGORNEWWORK,UNLESS
NOTEDOTHERWISE. DIMENSIONSSHALLHAVEPRECEDENCEOVERSCALE LARGER
SCALE DRHWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS.
9. PROVIDESHOPDRAWWGSWHEREINDICATEDANDFORALLMETALFABRICATIONOR
W HERE NOTED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL
SUBMITFlVE(5)SETSTOTHEARCHITECTWITHAMPLETIMETOREVIEW. RE�UIRED
CORRECTIONS W ILL BE NOTED AND A COPY W ILL BE RETURNED TO THE
CONTRACTOR. THECONTRACTORSHALLREVISETHE�RAWWGSAN�RESUBMITFOR
FINAL APPROVAL PRIOR TO FABRICATION.
10. CONTRACTOR TO SUBMIT SAMPLES OF ALL FINISH MATERIALS TO THEARCHITECT FOR
APPROVAL PRIOR TO INSTALLATION.
11. CONTRACTORSHALLMAINTAINACOMPLETESETOFAS-BUILTDRAWWGSNOTWG
DEVIATIONS BETW EEN THE DRAW I NGS, THE ACTUAL FIELD CONDITIONS AND THE NEW
CONSTRUCTION OFALL TRADES. AS-BUILT DRAWINGS SHALL BE DELNERED TO BANK
OFAMERICAATTHEENDOFTHEPROJECT. GENERALCONTRACTORSHALLPROVIDE
ALL SUBCONTRACTORS W ITH THE MOST CURRENT CONSTRUCTION DOCUMENTS
THROUGHOUTTHE PROJECT INCLUDING ALL REVISIONS.
12. CONTRACTORTONOTIFVARCHITECTANDBANKOFAMERICAPROJECTMANAGEROF
ALL REVISIONS TO THE DRAW INGS AND CHANGES TO THE SCOPE OF WORK OR
SCHEDULE AS REpUIRED BV GOVERNWG AGENCIES, FIELD CONDITIONS OR BANK OF
AMERICA PERSONNEL REGARDLESS OF EXTENT. ALL REVISIONS TO BE IN WRITING AS
CHANGE ORDERS AND APPROVED PRIOR TO STARTING W ORK.
13. CONTRACTOR TO VERIFV EXISTING STRUCTURAL CONDITIONS AND REpUIREMENTS
OF NEW CONSTRUCTION PRIOR TO START OF WORK. CONTRACTOR SHALL FURNISH
ADE�UATE SHORING, BRACING, ETC. AS RE�UIRED TO SAFETLV EXECUTE ALL WORK
AND SHALL BE RESPONSIBLE FOR THE SAME, UNLESS SPECIFICALLY DETAILED IN THE
�RAW WGS- CONTRACTOR SHALL PROVI�E BLOCKWG, BACKWG, FRAMWG, HANGERS,
OR OTHER SUPPORTS AS NECESSARV FOR ALL FIXTURES, EpU IPMENT AND ALL
OTHER ITEMS AS NECESSARV.
14. SITEANDBUILDINGSHALLBEMAINTAWEDINAQEAN,SAFEMANNER. DIRTVOR
NOISV W ORK SHALL BE PERFORMED AT SUCH A TI ME AS DI RECTED BV THE 0 W NER
AND/ OR CITV. ALL TRASH DEBRIS, SURPLUS MATERIAL, TWLS AND EpUIPMENT TO
BEREMOVEDFROMTHESITEANDDISPOSEDOFINALEGALMANNER. LEAVE
PREMISES IN A CONDITION ACCEPTABLE TO BANK OF AMERICA OR OW NER.
15. PROTECTAREAOFWORKANDADJACENTAREASFROMDAMAGE. WHEREEXISTING
CONSTRUCTION, FlNISHES OR EpUIPMENT IS DAMAGED BV WORK IN THIS CONTRACT,
IT SHALL BE PATCHED, REPAIRED OR REPLACEDAS RE�UIREDTO MATCH EXISTING AT
NO COST TO BANK OF AMERICA.
i6. THELOCATIONAN�ELEVATIONSOFALLWORKTOBECONSTRUCTE�ISSHOWNON
THEDRAWINGS. UNLESSDISCREPANCIESAREBROUGHTTOTHEATTENTIONOFTHE
ARCHITECT PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE HELD
RESPONSIBLE FOR THE PROPER LOCATION AND ELEVATIONS AS SHOWN AND
INTENDED.
1]. THE CONTRACTOR SHALL LAV-OUT THE WORK, ESTABLISH AND MAINTAIN NECESSARV
MARKERS AND BE RESPONSIBLE PoR THE ACCURACV OF THE W ORK. THE
CONTRACTOR SHALL MARK, AS A GUI�E TO ALL TRA�ES AN� TO HIS
SUBCONTRACTORS, THE EXACT LOCATIONS OF NEW OR REMODELED WORK WITH
RESPECT TO ALL CHANGES TO EXISTI NG.
18. INSTALLANDAPPLV ITEMS, MATERIALS, EQUIPMENT, FlNISHES, ETC.INCLUDWG THE
PREPARATION OF SURFACES IN STRICTACCORDANCE WITH THE MANUFACTURER'S
PRINTED RECOMMENDATIONS AND INSTALLATION REpUIREMENTS.
19. PERTAINWGTOEQUIPMENT:GENERALCONTRACTORISRESPONSIBLEFORTHE
REMOVAL AND RELOCATION OF ANV EXISTING EpUIPMENT OR CONSTRUCTION AS
NECESSARY FOR A COMPLETE INSTALLATION.
20. ACCESS PANELS SHALL BE PROVIDED FORALL EpUIPMENT SWITCHES, VALVES AND
OTHERCONTROLDEVICESTHATARECONCEALED. EXACTLOCATIONSTOBE
APPROVED BV ARCHITECT PRIOR TO INSTALLATION.
21. BESIDESGUARANTEESREpUIREDELSEWHERE,THECONTRACTORSHALL
GUARANTEE ALL W ORK PoR A MIN IMUM PERIOD OF ONE VEAR AFTER THE DATE OF
ACCEPTANCE OF W ORK W ITHOUT EXPENSE TO BANK OF AMERICA. GUARAMEE
SHALL INC W DE ANV W ORK THAT MAV BE DISPLACED BV GENERAL CONTRACTOR'S
WORK.
22. OBTAIN AND PAV PoR PERMITS AND INSPECTIONS REQUIRED BV PUBLIC AUTHORITIES
GOVERNWGTHE WORK.
23. SUBMIT REpUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT
FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.
24. OW NER W ILL PROVIDE W ORK NOTED "BV OTHERS" OR "NIC" UNDER SEPARATE
CONTRACT. CONTRACTOR SHALL INCLUDE SCHEDULE REpUIREMENTS IN
CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLV
SE�UENCE OF INSTALLATION.
25. CONTRACTORTOCOORDINATETELECOMMUNICATIONS,DATAANDSECURITVSVSTEM
INSTALLATIONS.
26. PROTECTAREAOFWORKANDADJACENTAREASFROMDAMAGE.
2]. DONOTSCALEDRAWINGS. WRITTENDIMENSIONSGOVERN.INCASEOFCONFLICT,
CONSULT THE ARCHITECT.
28. COOR�INATEAN�PROVI�EBLOCKWGFORMILLWORKAN�ITEMSATTACHE�OR
MOUNTED TO WALLS OR CEILINGS.
29. UNDERCUT DOORS TO CLEARTOP OF FLOOR FlNISHES BV 1I41NCH, UNLESS NOTED
OTHERWISE.
30. CONCEALED INSULATWG MATERIALS INSTALLED WITHIN WALL SHALL HAVE A FLAME
SPREAD I NDEX OF NOT MORE THAN ]5 AND A SMOKE DEVELOPED INDEX OF NOT
MORE THAN 450.
31. INSULATING MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE TO POTENTIAL
FlRE ON THE INSIDE OFTHE BUILDING DUE TO INSTALLATION IN UNCONCEALED
SPACES SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE
DEVELOPED INDEX OF NOT MORE THAN 450.
32. MATERIALSEXPOSEDWITHINPLENUMSAREREpUIREDTOBENONCOMBUSTIBLEOR
SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE
DEVELOPED INDEX OF NOT MORE THAN 50 AS DETERMWED IN ACCORDANCE WITH
ASTM E 84.
���
�
BANK OF AMERICA
& MERRILL LYNCH
10800 N. MICHIGAN RD.
ZIONSVILLE,IN 46077
SERIAL NUM./MANH. ID:
DESIGNATION:
NRSP VERSION: 2.0
BULLETIN: 07-2018
G�r�sl�r
11EMadison Te1 312 456 0123
Sui�e300 Fax 312A56.0124
CMragq IL 60G02
Uni�etl 9ates
Jones Lang LaSalle
T: 612271.8218
Attn: Patrick Hassett
!`.. Dale Descriplion
1 02.06.19 ISSUE FOR SO
2 03.18.19 ISSUEFOR00
3 W 26.19 ISSUE FOR CO
4 05.16.19 ISSUEFORDESIGNRELEASE
5 06.05.19 ISSUE FOR COE W COMMENTS
6 08.02.19 ISSUE FOR PERMIT
Seal I Sigreture
��,m (23t-t�i
Praject Name
ZIONSVILLE
PrajectNumher
21.0352.000
DesCriptian
GENERAL NOTES AND NPICAL
MOUNTING HEIGHTS
Scale
As indicated
A00.10