HomeMy WebLinkAboutM0.0 - MECHANICAL COVER SHEETVIEW KEY
NAME- LEVELNAME iQ- INDICATESNOTEUSEDTODESCRBE
� 10'-0"�HEIGHTABOVE ADDITIONALINFORMATIONABOUT
PROJECTO'-0" WORKREQUIRED,SPECIFICTOTHE
SHEET AND/OR DETAIL
-INDICATES DIRECTION OF TRUE NORTH
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
/'` � VIEW NAME
11 � „8._,.0.
- PLAN OR DETAIL SCALE
N�Rj�
INDICATES SIMILAR DETAIL
SIMr� REFERENCED IN MULTIPLE LOCATIONS
�-DETAIL REFERRED TO BV SECTION CUT
1
�`. M101 .�SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
SIM ����� REFERENCED IN MULTIPLE LOCATIONS
� DETAIL REFERRED TO BV ELEVATION
14 2"5........
o T101� SHEET DETAIL IS LOCATED ON
LINE TVPE KEV:
NEW WORKBYTHISCONTRACTOR
(DARK SOLID LINE)
NEW W ORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
(DARK LONG DASHED LINE)
NEW W ORK BV OTHERS AND/OR EXISTING TO REMAIN
(LIGHT SOLID LINE)
EXISTING TO BE REMOVED BV THIS CONTRACTOR
(DARK BHORT DABHED LINE)
FIRE / SMOKE BARRIER DESIGNATIONS
THE LME TYPES SHOW N ARE FOR THE CONVEMENCE OF THE CONTRACTOR. THE CONTRACTOR
SHALL VERIFV RATINGS W ITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL
MATERIALS REQUIRED TO COM PLV W ITH THOSE RATINGS W HETHER SHOW N OR NOT.
ALL [FLOOR, FLOOR CEILING, AND ROOF CEILING] ASSEMBLIES SHALL BE DESIGNATED AS [i], [2],
[3y [4] HOUR FIRE [/SMOKEy BARRIER(S), UNLESS NOTED OTHERW ISE ON THE PLANS. RATMGS
W ERE ACQUIRED FROM THE ARCHITECTURAL PLANS DATED ["P'P'].
NTD: COORDINATE W ITH ARCHITECT
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
3 HOUR FIRE BARRIER
4 HOUR FlRE BARRIER
iHOURSHAFTENCLOSURE
2HOURSHAFTENCLOSURE
SMOKE BARRIER
1 HOUR FIRE/SMOKE BARRIER
2 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE/SMOKE BARRIER
4 HOUR FlRE/SMOKE BARRIER
1 HOUR FlRE/SMOKE SHAFT ENCLOSURE
2 HOUR FlRE/SMOKE SHAFT ENCLOSURE
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
A.C. ASBESTOSABATEMENTCONTRACTOR
ALC. AUTOMATICTEMPERATURECONTROLCONTRACTOR
A.V.C. AUDIONISUALCONTRACTOR
C.C. CNIL CONTRACTOR
C.M. CONSTRUCTION MANAGER
EC. ELECTRICALCONTRACTOR
F.P.C. FIREPROTECTIONCONTRACTOR
F.S.C. FOOD SERVICE CONTRACTOR
G.C. GENERALCONTRACTOR
H.C. HEATING CONTRACTOR
M.C. MECHANICALCONTRACTOR
N.C.C. NURSECALLCONTRACTOR
P.C. PWMBINGCONTRACTOR
S.C. SECURITV CONTRACTOR
T.G TECHNOLOGVCONTRACTOR
T.C.G TEMPERATURECONTROLSCONTRACTOR
V.C. VENTILATIONCONTRACTOR
MECHANICAL SYMBOL LIST
NOT ALL SVM BOLS MAV APPLV.
SYMBOL: DESCRIPTION:
-BD- BOILERBLOW DOWN
-BF- BOILER FEED WATER
-CA- COMPRESSEDAIR
-CR- CONDENSER WATER RETURN
�S- CONDENSERWATERSUPPLV
-CS15- CLEAN STEAM - NUMBER INDICATES PRESSURE IN PSIG.
-CWR- CHILLED WATER RETURN
-CWS- CHILLEDWATERSUPPLV
-DPP- DRAIN
-G- NATURALGAS
-GV- GAS REGULATOR VENT
-GWR- GLVCOLWATERRETURN
-GWS- GLVCOLWATERSUPPLV
-HCR- HEATING/CHILLED WATER RETURN
-HCS- HEATINGICHILLEDWATERSUPPLV
-HG- REFRIGERANTHOTGAS
-HPC- HIGH PRESSURE CONDENSATE
-HPS- HIGHPRESSURESTEAM
-HWR- HEATINGWATERRETURN
-HWS- HEATINGWATERSUPPLV
-LCS- LOW PRESSURE CLEAN STEAM
-LIQ- REFRIGERANTLIQUID
-LPC- LOW PRESSURECONDENSATE
-LPS- LOW PRESSURESTEAM
-LWR- LOOP WATER RETURN
-LWS- LOOP WATER SUPPLV
-MV- MEDICALVACUUM
�R- OIL RETURN
-OS- OILSUPPLV
-PC- PUMPEDCONDENSATE
-PD- PUMPEDDISCHARGE
-RWR- REHEATWATERRETURN
-RWS- REHEATWATERSUPPLV
-SUC- REFRIGERANTSUCTION
-SV- SAFETVRELIEFVENT
-VAC- LABVACUUM
] PIPECAP
J PIPEDOWN
� PIPEUPORUP/DOWN
�� PITCH PIPE IN DIRECTION
� DIRECTION OF FLOW IN PIPE
�i NEW CONNECTION
�i� DIELECTRICCONNECTION
�I� UNION/FLANGE
DG SHUTOFF VALVE NORMALLV OPEN
N SHUTOFF VALVE NORMALLV CLOSED
tq THROTTLING VALVE
Igi BALANCINGVALVE�NUMBERINDICATESGPM)
CI AUTOMATIC BALANCING VALVE
� MIXING VALVE
� CONTROL VAWE (THREEWAV)
p$ CONTROL VAWE (PNO-WAV)
� SOLENOIDVAWE
�'�� CHECKVALVE
y'y SAFETV/RELIEFVAWE
��
8 PRESSURE REDUCING VALVE (LIQUIDIGAS)
� PRESSURE REDUCMG VAWE (STEAM)
� TRIPLE DUTV VALVE (ANGLE TVPE)
0 TRIPLE DUTV VALVE QN-LINE TVPE)
� PUMP
Y VACUUM BREAKER
�� "WVE"-STRAMER
� "WVE"-STRAMERW/SHUTOFFVAWEANDHOSECONNECTIONWITHCAP
� BASKETSTRAINER
�Q1:=� REXIBLECONNECTION
� PRESSURE/TEMPERATURETESTPLUG
_� REDUCER-REFERENCESPECIFICATION
FOR CONCENTRIGECCENTRIC AND FOT/FOB
� SUCTION DIFFUSER W ITH SUPPORT FOOT
$ AUTOMATICAIRVENT
+ MANUALAIRVENT
Ta
} DRAIN VALVE W ITH HOSE CONNECTION AND CAP
i
�� PRESSURESENSOR(FURNISHEDWITHBALLVALVE)
� PO PRESSURE GAUGE (FURNISHED W ITH BALL VALVE)
�� DIFFERENTIALPRESSURESENSOR
t
t
_ gp STATICSWITCH
FM FLOW METER
� FLOW SWITCH
FS FLOW SENSOR
�T; STEAMTRAP�REFERTOSCHEDULE)
F8T STEAM TRAP ( REFER TO SCHEDULE)
DT•
R INVERTED BUCKET STEAM TRAP (REFER TO SCHEDULE)
u T•
- ALIGNMENTGUIDE
PIPE ANCHOR
�- EXPANSION JOINT
� METER
MECHANICAL SYMBOL LIST
NOT ALL SVM BOLS MAV APPLV.
SYMBOL: DESCRIPTION:
- -- DIRECTION OF AIR FLOW
�� I I I I I C- FLEXIBLE DUCT
-�- MANUALVOLUMEDAMPER
-- R- RISE IN DIRECTION OF AIR FLOW
-� D- DROP IN DIRECTION OF AIR FLOW
� DUCTCAP
-�� DUCTDOWN
--_� DUCT UP
� SUPPLV/OUTSIDEAIRDUCTSECTION
� RETURN AIR DUCT SECTION
� EXHAUST/RELIEFAIRDUCTSECTION
� 4-WAV DIFFUSER WITH BLANKOFF IN ONE DIRECTION
CD-1 qIRTERMINALPROPERTIESSVMBOL
6/115 NECK SIZE/CFM
�I###I TERMINALAIRBOX�REFERTOSCHEDULE)
� ��I TERMINALAIRBOXw/REHEATCOIL�REFERTOSCHEDULE)
SERIES FAN POWERED TERMINAL AIR BOX wIREHEAT COIL
� (REFERTOSCHEDULE)
� PARALLELFANPOWEREDTERMINALAIRBOXw/REHEAT
COIL (REFER TO SCHEDULE)
� �` HUMIDIFIER
O OPPOSED BLADE DAMPER (REFER TO SCHEDULE)
O PARALLELBLADEDAMPER(REFERTOSCHEDULE)
�� DIFFERENTIALPRESSURESENSOR
HQ HUMIDISTATSENSOR
H❑ HUMIDISTATISENSOR
CQ CARBON MONOXIDE SENSOR
O CARBONDIOXIDESENSOR
2
OO OCCUPANCVSENSOR
� PRESSURE SENSOR/MONITOR
P� PRESSURESENSOR�DUCTMOUNTED)
QRTU-X PRIMARVTHERMOSTATW/DIGITALDISPLAV
QT ADDITIONALAVERAGNGTHERMOSTATISENSOR�NODISPLAV)
�T TEMPERATURE SENSOR
T� THERMOSTAT/SENSOR WITH HEAW DUTV ENCLOSURE
4 �� TEMPERATURESENSORWITHWELL
Q THERMOMETERWITHWELL(DIALTVPE)
��
4 THERMOMETERWITHWELL�FILLEDTVPE)
U
� XX-V AIRFLOWMEASUREMENTSVMBOL
-� XX-AHUSVMBOL
V -SEQUENTIAL NUMBER
ABBR:
AD
AFF
C
CO
CD-E
CFSD
DPO (0-2")
DPS
EA
ECFSD
EFD
EFSD
EP
ESD
FD
FOB
FOT
FSD
MA
MV
NC
N.C.
NIC
N.O.
OA
PS
RA
SA
SD
TAB
TD
TVP
UC-1
UNO
VD
MECHANICAL ABBREVIATION KEY
DESCRIPTION:
ACCESSDOOR
ABOVE FINISHED FLOOR
COMMON
CLEANOUT
CEILMG DIFFUSER - EXISTMG
CONTROIJFIRE/SMOKE DAMPER
DIFFERENTIAL PRESSURE GAUGE (RANGE)
DIFFERENTIAL PRESSURE SW ITCH
EXHAUSTIRELIEF AIR
EXISTING CONTROL FIRE SMOKE DAMPER
EXISTING FIRE DAMPER
EXISTING FIRE SMOKE DAMPER
ELECTRICAL TO PNEUMATIC VAWE
EXISTING SMOKE DAMPER
FIRE DAMPER
FLAT ON BOTTOM
FLAT ON TOP
FIRE/SMOKE DAMPER
MIXEDAIR
MIXMG VALVE
NEW CONNECTION
NORMALLVCLOSED
NOT IN CONTRACT
NORMALLV OPEN
OUTSIDE AIR
PRESSURESWITCH
RETURN AIR
SUPPLV AIR
SMOKE DAMPER
TERM INAL AIR BOX
TRANSFERDUCT
TVPICAL
DOOR UNDERCUT BV OTHERS (1"TVPICAL)
UNLESS NOTED OTHERW ISE
VOLUME BALANCMG DAMPER
MECHANICAL GENERAL NOTES:
THESE NOTES APPLV TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIM ITED
TO PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. DRAWINGSSHOWINGLOCATIONSOFEQUIPMENT,DUCTWORK,PIPING,ETC.ARE
DIAGRAMMATIC AND MAV NOT ALWAVS REFLECT EXACT INSTALLATION CONDITIONS.
DRAW MGS SHOW THE GENERALARRANGEMENT OF DUCTWORK, PIPMG, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THEDRAWINGSSHALLBEFOLLOWEDASCLOSELVASACTUALBUILDING
CONSTRUCTION AND THE W ORK OF OTHERS W ILL PERMIT.
2. DONOTSCALEDRAWINGS. VERIFYALLDIMENSIONSAND0.EARANCESFROM
ARCHITECTURAL, STRUCTURAL, SUBM ITTALS, AND OTHER APPROPRIATE DRAW INGS OR
PHVSICALLV ATSITE REVIEW ALL DRAWMGS, INCLUDMG THOSE OF OTHER TRADES.
3. COORDINATEALLWORKWITHALLOTHERTRADESPRIORTOINSTALLATIONTOPROVIDE
CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO
VERIFV NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIORTO
VERIFlCATION OF NECESSARV CLEARANCES FOR ALL TRADES. BRMG ANV INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING
W ITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEWSPACEREQUIREMENTSOFEQUIPMENTSPECIFIEDORSUBSTITUTEDANDMAKE
REASONABLE ACCOMMODATIONS IN LAVOUT AND POSITIONING TO PROVIDE PROPER
ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BV THE CONTRACTOR W ITHOUT ADDITIONAL COST OR
EXPENSETO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED W ITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
1. REFERTO ARCHITECTURAL RERECTED CEILING PLAN, ELECTRICAL, TECHNOLOGV
AUDIONISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHMG TO MATCH ORIGINAL CONSTRUCTION, FIRE RATMG, AND
FINISH.
9. IN AREAS W ITH DRVWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS W ITH THE
GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETG COORDINATE
PANEL TYPE AND COLOR W ITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS
PANELS PRIOR TO BIDDING.
10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONSAIRTIGHT WHERE CONDUITS, PIPMG,
AND DUCTS PENETRATE PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE
SEALEDAIRTIGHT WITH WATERPROOFING MATERIALS RECOMMENDED BV MANUFACTURER
FOR OUTDOOR USE.
11. CAULK ALL PIPE AND DUCT PENETRHTIONS OF FULL HEIGHT NON-FlRE RATED WALL,
PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE
TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS
W ITHIN ROOMS.
12. WHEREPIPESANDDUCTSARESHOWNTOPENETRATEFLOORS,PROVIDESLEEVED
OPENMGS W ITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE W ITH ALL
RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.
13. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARV AMONG DIFFERENT
MANUFACTURERS. CONSULTAPPROVED SHOP DRAWMGS FOR EQUIPMENT S2ESAND
REQUIRED SERVICE CLEARANCES. COORDINATE W ITH LAVOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
14. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
15. MAMTAIN MINIMUM 3'-6" CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SW ITCHES, AND DISCONNECTS.
i6. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL
EXTEND MINIMUM 6" BEYOND ALL SIDES OF EQUIPMENT.
1]. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER
NON-STRUCTURAL BUILDMG ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE W ITH SPECIFlCATIONS.
ABBR:
AD
AFF
BFP
BT
CB
��
CO
CS
DB
DF
DI
E
EE
ES
ESE
EWC
FCO
FD
FM
FS
GD
GI
HB
I.E.
LAV
MB
MH
MV
NC
NIC
NT
OS
RD
SH
SK
SS
TD
TP
TYP
UR
VTR
WC
WCO
WF
WH
WMF
WM
WS
UB
UNO
VCO
PLUMBING ABBREVIATION KEY
DESCRIPTION:
ACCESSDOOR
ABOVE FINISHED FLOOR
BACKFLOW PREVENTER
BATHTUB
CATCH BASIN
CAST IRON
CLEANOUT
CLINICAL SINK
DIALVSIS BOX
DRINKING FOUNTAIN
DUCTILE IRON
EXISTING
EMERGENCVEVEWASH
EMERGENCVSHOWER
EMERGENCV SHOWER/EVEWASH
ELECTRIC WATER COOLER
FLOORCLEANOUT
FLOOR DRAIN
FLOW METER
FLOOR SINK
GARBAGE DISPOSER
GREASEINTERCEPTOR
HOSE BIBB
INVERTELEVATION (FOR REFERENCE ONLV)
LAVATORV
MOP BASIN
MANHOLE
MIXING VALVE
NEW CONNECTION
NOT IN CONTRACT
NEUTRALIZATION TANK
OIL SEPARATOR
ROOF DRAIN
SHOWER
SINK
SERVICE SINK
TRENCH DRAIN
TRAP PRIMER
TYPICAL
URINAL
VENTTHROUGHROOF
WATERCLOSET
WALL CLEANOUT
WASH FOUNTAIN
WATERHEATER
WASHING MACHINE FIMURE
WATERMETER
WATERSOFTENER
UTILITY BOX
UNLESS NOTED OTHERW ISE
VARD CLEANOUT
VENTILATION GENERAL NOTES:
1. ALIGNTEMPERATURESENSORSWITHLIGHTSWITCHESANDWHENINCLOSEPROXIMITVTO
EACH OTHER.
2. PROVIDEACCESSDOORSATALLDUCTMOUNTEDEQUIPMENT.
3. PROVIDE A MANUAL BALANCING DAMPER ON EACH DUCT BRANCH THAT SERVES A
DIFFUSER OR REGISTER.
,. THES�Meo�s PD UMBINGSGENERAL�NNOTESTHE�oNTRA�TOR.
CONTRACTOR SHALL VERIFY QUANTITIESAND FURNISH ALL MATERIALS REQUIRED FOR
FULLV OPERATIONAL SVSTEMS, WHETHER SPEQFlED OR NOT.
2. CATALOGNUMBERSSHALLNOTBECONSIDEREDCOMPLETE,BUTAREGIVENASANAIDTO
THECONTRACTORANDTOINDICATETHEQUALITYREQUIRED. CONTRACTORIS
RESPONSIBLE FOR A COMPLETE DESCRIPTION OF MATERIAL ON THESE DRHW MGS AND IN
THE SPECIFICATIONS BEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES
PRECEDENCE OVER THE CATALOG NUMBER. THE FIRST MANUFACTURER LISTED ISTHE
BA515 OF DESIGN.
3. CONTRACTORSHALLVERIFVTHATFIXTURESSUPPLIEDAREAPPROVEDPERALL
APPLICABLE STATE, LOCAL AND GOVERNING AUTHORITIES.
4. ALL FlXTURES SHALL CONFORM TO FEDERAL ACT 5.3814
5. INVERT ELEVATIONS ARE FROM DRAW INGS AND MAY NOT BE ACCURATE. VERIFY ALL
ELEVATIONS BEFORE BEGINNING WORK.
6. VERIFVUNDERGROUNDPIPESRES,INVERTELEVATIONS,ANDLOCATIONSPRIORTO
BEGINNING ANY WORK.
1. REFERTOTHEPLUMBMGROUGH-INSCHEDULEFORTHESIZESOFBRANCHPIPESTO
PLUMBMG FlXTURES.
8. FOR CLARITV, NOTALL VALVES HAVE BEEN SHOWN. PROVIDE SHUTOFF VALVES IN
DOMESTIC WATER PIPMG SERVMG EACH ROOM W ITH FIXTURES. ANGLE STOPS SHALL NOT
BE CONSIDERED SHUTOFF VALVES.
MECHANICAL SHEET INDEX
M0.0 MECHANICALCOVERSHEET
M1.1 FlRSTFLOORPLAN -MECHANICAL
M12 ROOFPLAN-MECHANICAL
M2.0 MECHANICAL DETAILS
M3.0 MECHANICALSCHEDULES
M4.0 MECHANICALCONTROLSWIRMG�IAGRAMS
M4.1 MECHANICALCONTROLSWIRMG�IAGRAMS
PLUMBING SHEET INDEX
P1.0 11NDERFLOOR PWMBING PLAN
P1.1 FIRSTFLOORPLAN-PLUMBING
P12 ROOFPLAN-PLUMBING
P2.0 PLUMBING DETAILS
P2.1 PLUMBING RISERS
P3.0 PLUMBINGSCHEDULES
.�'i�,.%►
�
BANK OF AMERICA
& MERRILL LYNCH
10800 N. Michigan Roatl
Zionsville, IN 46077
SERIAL NUM./MANH. ID:
DESIGNATION:
NRSP VERSION: 2.0
BULLETIN: 07-2018
Gensler
11EMadison Te131245G0123
Suite300 Fax 312A56.0124
Chiragq IL 60602
Unitetl States
Jones Lang LaSalle
T: 612271.8218
Attn: Patrick Hassett
�IMEG anzwc�a+eomu+oo��,
nima� ossa• v�� napo-n�oox�mmisn m�a
,:a�nmoaaqnciaanomorimeccoaa �zo�simeacoAa I
excesuieixw�xes
o � a
i�`.. Dale Descriplion
1 08.022019 ISSUE FOR PERMIT
�
07,31.Zo
Seal I Sigreture
Praject Name
CARMEL
PrajectNumher
21.0352.000
DESClipfian
MECHANICAL COVER SHEET
Scale
NOT TO SCALE
RELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
of Sla�e antl Local Codes
City of Carmel
�i
`��¢m�' lamn�Ml1 �
onrE: 12/31/19
M0.0
� zai s ce�s e�