Loading...
HomeMy WebLinkAboutP1.1 - FIRST FLOOR PLAN - PLUMBINGRELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�Ml1 � onrE: 12/31/19 �'� 1.1 r �2 �' �2.2;(2.3 ;24i i2.5i � � �, .� ---- � — ---------- ir I �T I I �T — — — — — — � — — — — — � 3•.STS I — 3,.Sj5� .. - 3 � � p��� " ��� I I I ��o � I I �o�o. i i i i i I I I I I I I I I � I I o CT — ❑ — _ — — — , _ O FCO ;� 1/2"HW �3 1 � � DROP PIPING ON WARM SIDE OF INSULATION. I ' PIPMGSHALLBEINSULATEDWITH2X THE SPEGFlED THICKNESS OF INSULATION. NJEL W ESS ROOM I CT I9 � — �� � — .�i I I . VY'HW V� .,.. I � 1/2CW R� 2VUPTHRUROOF I��—� �O ET-1 T�H�1 WORK �g I I _ �_ ROOM TELLER o- � g'� � 112 � . 113 � C. 3/4"HW 1 1/2' P' FD FCOO I , VY'CW �.� VY'CW�.:. 3l4"GW 3/4" C W UP TO RH � � 2"GW p� � '-� —2"GW 1112"GW i V2"V— V2HW � LAV - UPT04"RD��. : UPT04"RD A HEDF .—UPT04"R� X ���4CW ��� WH � ����� MENS � � �'F'� '� ' �� � � ��(;�' �� RESTROOM � 3/4 CW STORAGE >> WATER METER 8 WATER PIPE SIZES ARE BASED ON A M INIMUM c�i WORKING PRESSURE OF ? 44 (PSIG) AT A FLOW RATEOF �S�GPM). CORRI�OR WH � FCOO 1111112•'G �4"CW GAS •. .......... 1 1/2" GAS UP WITH METER SHUT OFFVALVE ELECTRICAL — ���TI6A� — CLOSET � 111 I i � ESTIMATED TOTAL G--4' CONNECTEDLOAD: 456CFHOFNATURAL ' OFFICE GAS 105 � SBBOFFICE � 1� HL OFFICE 103 CC CENTRAL ZONE 101 �.31 �1.4 � � '-��.� ��;2a-{�- 11/2"V11 , 1 V2"V , v /PA \ 1 — 2 FD M / � UPT04"RD �. 1/2"CW _. :._'1 _11/P'V , � .-3/4"CW / . �,� 1/2CW , LAVv�i 1/2"HW MS�•�ET2TWH-�. 1/2"CW FA�4 �� UPT04"FD V2'CW -. � � � � �i VYV � n LAV �3/4"HW"— WOME $'.1/2CW` 6"STDN , � L-�..� ..-� '""_'"__ �T � OFCO 1/2 HW �� 1 HW 4•'ST CO � RESTROOM � HWCi-> I-2 V VY'HW .,._ _ 11/4"CW� � � UR .. — — .1 1/2"CW ._..�� 1 VY'V — — — — — — — �� — — ii/a•'cw-.. p c�02"F� 12a .._."____� fFVJCi H� � p^V �I pFCO CO � r � � 11/4"GW� I � � � � Y'V UP THRU ROOF �� WORKSTATIONS I' FA�Z p 127 I I � I I 0� I � iW MAIL M 121 — — — — — � I — — — — — — — — — ' TM WORK I HPd � I ROOM I 12B i 1� i _____ RECEPTION - 120 I I I I r——n--� FSAOFFICE � I I CONFERENCE I 102 II I 125 — — — — — — — — — — — �— FA 1 — — — HP 1 — — — — 123 124 I I ��/ ML � VESTIBULE 119 I — o_ — — —❑ _ � � — C , — � — ❑ — — — — ❑ — za Ha. I I VESTIBU E 100 � � � — . L— � — — � — — — — — — — — — — �1 FIRST FLOOR PLAN-PLUMBING 'I � 3/16._�.�. �oRT� I � ii I NER \q� — O � �� UNISEX iESTR00M 1� /� — � C _ ��p� — �D,1j �� - �� �i' .�'i�,.%► � BANK OF AMERICA & MERRILL LYNCH 10800 N. Michigan Road Zionsville, IN 46077 SERIAL NUM./MANH. ID: DESIGNATION: NRSP VERSION: 2.0 BULLETIN: 07-2018 Gensler 11EMadison Te1 312 456 0123 Sui�e300 Fax 312456.0124 CMragq IL 60G02 Uni�etl States Jones Lang LaSalle T: 612271.8218 Attn: Patrick Hassett � I M EG rnzw c�a +eomu+oo� �, nima�ossa•v��na��.n�a.x�mm�cnm�a uze me Exc��sive rHorEHraor iMEc coHr Arvopsn�Rpnor eE �sEo oH�a wrzirrery aroaovn�nrvoauaimannomoFimcocoaa ezmeimeocoaa. excesc<ieixixcxes o � s a `'�..Oale Oescriplion 1 08D22019 ISSUE FOR PERMIT � 07,31.Zo Seal I Sigreture Praject Name CARMEL Praject Numher 21.0352.000 Descriptian FIRST FLOOR PLAN - PLUMBING Scale 3/16" =1'-0" P1.1 o zois ce�sie�