HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION
Customer Name
{\C256;* Market Home *, 6838-02800#2}
Address{\C256;13041 COPPER RUN BOULEVARD}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074}
Community{\Fsimplex|c0;\C256;6838}{\C256;COPPER RUN}{\C256;6838-02800}{\C256;LOTNUM 123}
Plan Features{\C256;Elevation HR3W}
MUNICIPALITY
STRUCTURAL ENGINEER APPLICABLE CODES
MECHANICAL ENGINEER
BUILDING CODE ANALYSIS
DESIGN LOADS and CRITERIA
AREA CALCULATION (SQ. FT.)
\pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; }
ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF
\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}
\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}
SHEET LIST TABLE
SHT DESCRIPTION
CC.01 Cover Sheet
CC.02 Notes - Schedules and Legends
A0.01 Foundation - Basement
A1.01 Finished Basement Floor Plan
A1.11 1st Floor Plan
A1.21 2nd Floor Plan
A2.02 Building Section
A2.03 Building Section
A3.01 Front Elevation
A3.02 Left Elevation
A3.03 Right Elevation
A3.04 Rear Elevation
A4.01 Roof Plan
U1.01 Finished Basement Utility Plan
U1.11 1st Floor Utility Plan
U1.21 2nd Floor Utility Plan
Structural Plan - Foundation Basement (IN Code)
Structural Plan - 1st Floor (IN Code)
Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt. Additional Cabinets at Pulte Planning CenterOpt. Base Cabinet at PPCBath 7 OptionBedroom 7 OptionBuilt in Kitchen OptionOpt Coach Light - Location 1Opt Coach Light - Location 3Opt Deck at RearElevation HR3WNo OptionFinished Basement OptionStandard Flex RoomBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageGathering Room - Additional WindowMasonry Wrap - Sides and RearOwners Suite - Additional WindowsBase Owner's BathIndianaOpt SunroomOpt. Tray Ceiling at Dining RoomOpt Tray Ceiling at Owners SuiteOpt Basement Window Well - Location 1Opt Basement Window Well - Location 4
SQUARE FOOTAGE
TOTAL:CONDITIONED - LIVABLE SF
1st Floor
1st Floor - Sunroom
2nd Floor
Basement - Finished
Basment - Finished - Sunroom
1746 SF
168 SF
1777 SF
1257 SF
162 SF
5110 SF
TOTAL:CONDITIONED - NON-LIVABLE SF
Basement - Storage & Mech
Basement - Storage & Mech
124 SF
211 SF
335 SF
TOTAL:UNCONDITIONED SF
3 Car Garage Side
3 Car Garage Side
Front Porch
22 SF
676 SF
140 SF
838 SF
6283 SF
COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc.
PRODUCT MANAGERRICK STARKEYVERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Deer Valley
2107.300Home for * Market Home *, 6838-02800#213041 Copper Run Boulevard, Carmel, IN 46074CC.01
12/31/19
David Rutti