HomeMy WebLinkAboutE201 POWER AND SYSTEMS PLAN■
�
E
3
A!
5
0
I_1
ca
cE �,E
I7
CD.S
0
� g � H FIXED
� R20
E18
��EC F. ix�i r
I E16 � DC /� E1] ��A-8....
: —5���2 � �-
C3.5 � � , WEH-i i
B 12
C3
d
czs
RELEASED FOR CONSTRl1CTI0N
s�e;e��m�om,na��e.�maiire9�iaua�� A6, POWER AND SYSTEMS PLAN
ofS�a�eantllncalCodes `.._/ ��4"=�'-0" 0�� 6'
City of Carmel
� ,�,,,�,�:,��ti�a �
�, e
onrE: 01 /13/20
[y
CD
�T� -
METER:�� E33 �
B-22 E32 A-10.12.14 I
� E14 -
y.,i� ;.
� E34 I..� B-I12 B A PA�EIR R9,��6-21
SH ED B ��
I TX B-26 =� :°' B-10f
B-21�
A2 R1C
..,�400 !B-21
Eqfi� � E31 omce B-21�
� Eis "
�� g 7 fJ%f
Ri!
RHC 1 .
_—_—_ ' A-2.46��
FIXED
R18 B-"12
# �� �
I �-� �� B.�. � _ ' —
� eza �.�JEF-� 1 eiz F`_e'� � eia �� eaoo � i� —
� �.(�B-2 3� DSIi �
�MX/1 / E A-7.9.11 I �_ .
MX/1 �u RTU-1 WP I i
� �B 19 �� BFIq . E35 � i�.
I ; �
�W GFl E29
B 3� . / E36 m �
� �`_���� —
B 34;
5lOLN �
PMM
1W �B-
FlXED u-
[y
CGS
U7
�«sa�E
�o
� /
iz
S1
5�
lii tl!il; ,�.
�..._�
I!I tllii�.. 5�
S1
U7
CC
- �� -
CB.S
CB
— Fr� —
H E
GENERAL POWER AND SYSTEMS NOTES , Z z
1. FIREALARM:
A. PROVIDEALLNEWFIREALARMDEVICESAND w -
CONNECTIONSTOEXISTINGFIREALARMSVSTEMAT "
MALL FlELD VERIFV MOUNTWG LOCATIONSAND -� @ 3
REpUIREMENTS WITH MALL PRIOR TO BID. �= 3
B. PROVIDEADRVCONTACTCLOSUREFROMTHEFlRE � Z '��
ALARM SVSTEM TO THE SOUND SVSTEM SUCH THAT w� m
THESOUNDSVSTEMSHUTSDOWNWHENTHEFIRE —m
ALARM SVSTEM GOES INTO ALARM.
C. REFERTOFIREALARMSPECIFICATIONSECTIONON � � � �
SHEET E000 FOR MORE WFORMATION. ` F N LL =
7 �m
I �a —
I/1�1 V �tO
�/ 1 ¢ m 3
\:�z`.,�E�isrcaea �'o�:
�� � v�nn��wsno �
%A'. SWiEOF : 4
i�TF • :ry0 i P�P' 2�:
,/,',��ONINII tl�0\��
`n-m-- X %�.-c.�.
&pires:07-31-2@0
1111119 1:59 PM
2
3
CA2
_ �
CA.CA
G
KEYNOTES
Ep4 WINDOWDISPLAVRECEPTACLEMOUNTEDHORIZONTALLVAT60TTOMSILLMETAL
RAIL ROUTE CONNECTION THROUGH METAL RAIL AS REpUIRED.
E05 MOUNT BUZZER ON TOP OF SHELVING AND HIDDEN FROM PUBLIC VIEW. CONNECT
TO DELNERV SERVICE PUSH BUTTON AT REAR ENTRANCE. REFER TO REAR
ENTRANCE SECURITV ORDER OF OPERATIONS ON THIS SHEET FOR MORE
INFORMATION.
E06 PROVIDEONE(1)PANICBUTTONATCENTEROFCASHWRAPCOUNTER.ROUTE22/4
STRANDED W IRE UNDER FLOOR TO WALL W ITH CONDUIT STUBBED UP TO ABOVE
ACCE5518LE CBLING. PANIC BUTTON IS NOT A NETWORK �EVICE BURGLAR ALARM
PANEL IS THE ONLV DEVICE TO BE RUN TO THE EpUIPMENT RACK.
E0� MOUNTALLPOWERANDDATADEVICESINSTOREFIXTUREANDCOORDINATEWITH
MILLWORK. POW ER AND DATA TO CASHWRAP RXTURE SHALL BE FED VIA FLOOR
POKE THRUS. NO SAW CUTTI NG OR TRENCHING OF THE SLAB IS ALLOW ED.
COOR�INATE EXACT POKE THRU LOCATIONS WITH EXISTING CON�ITIONS.
E08 PROVIDEALLCAT6CA8LWGFOREACHWIRELESSACCESSPOINTUSWGKEVSTONE
CONNECTORS (DO NOT AFRX KEVSTONE IN A BOH) ON THE W IRELESS ACCESS
POINT END WITH TERMINATION OF THE OTHER CABLE END INTO THE PATCH PANEL
IN THE E�U IPMENT RACK (ATTACHMENTS INCLUDED W ITH THE DEVICE CAN BE
MOUNTED TO THE CBLING GRID OR TLLE BV OW NER'S IT DEPARTMENT). PROVIDE
15' OF A��ITIONAL CA6LE ON WIRELESS ACCESS POINT END FOR FLEXI6ILITV IN
PLACEMENT.
E09 POINT OF SALE ISOLATED GROUND RECEPTAQE MINIMUM QRCUIT SIZE SHALL BE
2#12+1#12 GND+1#12150 GROUND,'/." C.
E10 VOICE OVER INTERNET PROTOCOL (VOIP) PHONE IN THIS LOCATION SHARES THE
SINGLE NETWORK RUN TO THE REGISTER. ADDITIONAL NETWORK RUN SHALL BE
ROUTED TO EACH REGISTER LOCATION FOR FUTURE USE.
E11 PROVIDECAT6CABLEFOREACHCAMERHUSINGKEVSTONECONNECTORS(DO
NOT AFFlX KEVSTONE I N A BOX) ON THE CAMERA END W ITH TERMINATION OF THE
OTHER CA6LE END INTO THE PATCH PANEL IN THE EpUIPMENT RACK. PROVIDE 10'
OF ADDITIONAL CABLE ON CAMERA END FOR FLEXIBILITV IN CAMERA PLACEMENT.
ALL CAMERA CABL W G SHALL BE TESTED PRIOR TO COMPLETION DATE W ITH
OW NER.
E12 RECEPTACLEFORFAUCETANDTRAPPRIMERPOWER.COORDINATEEXACT
LOCATION W ITH PLUMBING CONTRACTOR PRIOR TO ROUGH-IN.
E13 CONNECT BUZZER TO DELNERV SERVICE PUSH BUTTON AT REAR ENTRANCE.
REFER TO REAR ENTRANCE SECURITV ORDER OF OPERATIONS ON THIS SHEET FOR
MORE INFORMATION.
E14 VOICEOVERINTERNETPROTOCOL(VOIP)PHONEATMANAGER'SDESKSHARES
THE SINGLE NETWORK RUN TO THE MANAGER'S COMPUTER.
E15 COORDINATEALLLOCATIONSOFPOWERANDDATAWITHFlNALOFFlCEFURNITURE
LOCATIONS PRIOR TO ROUGH-IN. REFER TOARCHITECTURAL ELEVATIONS FOR
MORE INFORMATION.
Ei6 PROVI�E120VPOWERCONNECTIONANDCOMPATIeLELOWVOLTAGE
TRANSFORMER FOR DELIVERV PUSH BUTTON SVSTEM. CONNECT DELIVERV
SERVICE PUSH BUTTON TO LOW VOLTAGE BUZZER MOUNTEDAT BACKWRAP AND IN
THE BACK OF HOUSE AREA. PROVIDE REFERTO REAR ENTRANCE SECURITV
ORDER OF OPERATIONS ON THIS SHEET FOR MORE WFORMATION.
Ei] EMPLOVEEACCESSKEVPAD.CONTRACTORSHALLPROVIDEONE(1)'/."CONDUIT
AND 18/4 STRANDED W IRE FROM KEVPAD TO BURGLAR ALARM PANEL. ALL FlNAL
CONNECTIONS SHALL BE MADE eY SECURITV SVSTEMS VENDOR. COORDINATE
EXACT REQUIREMENTS WITH SECURITV SVSTEMS VENDOR PRIORTO ROUGH-IN.
KEVPAD IS NOT A NETWORK DEVICE. BURGLAR ALARM PANEL IS THE ONLV DEVICE
TO BE RUN TO THE EpUIPMENT RACK.
E18 ELECTRICALCONNECTIONFORDOORPOWERSUPPLV.PROVIDEPOWERANDALL
NECESSARY PATHWAYS FOR DETEX ALARM SYSTEM.
E28 EXHAUST FAN SHALL eE CONTROLLE� VIA OCCUPANCV SENSOR IN RESTROOM.
OCCUPANCV SENSOR SHALL BE SET TO A 3� MINUTE TI ME DELAV.
E29 PROVIDE DUCT DETECTOR IN RETURN DUCT OF NEW ROOF TOP UNIT. DUCT
DETECTOR HOS W G SHALL eE FURN ISHE� eY ELECTRICAL CONTRACTOR, AND
INSTALLED BV MECHANICAL CONTRACTOR. FINAL CONNECTION BV APPROVED FIRE
ALARMVENDOR.
E31 PROVIDENEWWALLMOUNTEDTRANSFORMERANDWALLBRACKETS.REFERTO
RISER DIAGRAMS AND WALL MOUNT XFMR ELEVATION FOR MORE WFORMATION.
E32 PROVI�E NEW PANEL. REFER TO RISER DIAGRAMS FOR MORE INFORMATION
E33 PROVIDEANEW100AMETER.REFERTORISERDIAGRAMSFORMORE
WFORMATION.
E34 PROVIDE A NEW FlREALARM CONTROL PANEL. PROVIDE NEW FlRE ALARM DEVICES
AND CONNECTIONS TO EXISTING FlRE ALARM SVSTEM AT MALL FlELD VERIFV
MOUNTWG LOCATIONS AND REQUIREMENTS PRIOR TO 81D. PROVIDE A DRV
CONTACT CLOSURE FROM THE FIREALARM SVSTEM TOTHE SOUND SVSTEM SUCH
THAT THE SOUND SVSTEM SHUTS DOW N W HEN THE FI RE ALARM GOES INTO
ALARM.
E35 RECEPTAQEANDJELLVJARLIGHT(F10)ATRTUSHALLBEPOWEREDFROMTHE
SAME CIRCUIT AS SHOW N. REFER TO RTU MAINTENANCE LIGHT AND OURET
DETAIL ON SHEET E400 FOR MORE WFORMATION.
E36 PROVIDE REMOTE TEST STATION FOR �UCT �ETECTOR. COORDINATE EXACT
LOCATION W ITH MECHANICAL CONTRACTOR AND FIRE ALARM VENDOR PRIOR TO
CA.8 CAS
, Eo5
�f' � . � �� ��
� B-25� � ❑ �B-25
0 0
/ 1 j�� rI E400 j� II il' II'I�I
III o� � E08 R4 ' i�l I
� I ��� ..- I� FR 5D i. .i g26.. R1+R2�Pg23'�623;R22 g26, 63*R23 i i � III_— � ��,��
(TVP) EI�B .�f'26" "., �.� r—� � - ��
(T�,P�� E.�p �. , � EO] , � �
� -� �,�IIIIIIII� II .�. f E11 �.
�' � �
FIXED
R16
�� .. _ l� � flll�'.'„ ,�r' IIII�'�..
� � � . i� • �S�
LJ L
B 45
= ����II !ill��i �� '
� I
. i� -���.�:
"L'=
�� ��`�� '�.o����l� � 111,� Illi� � 5 f �iii �
FLOOP I� � �j �
__ �� ._. �II . I � IIII��' , `���,:
FCCESSQilES
tLpJ
F� u F� u F�m��
ase osc +oso
E
E F
REAR ENTRANCE SECURITY
SEQUENCE OF OPERATIONS
• REAR ENTRANCE SHALL BE USED FOR'.
A. INITIAL STORE OCCUPANCV
B. DELIVERIESTOSTOREATTHEBEGINNINGOFEACHDAV
• MANAGERDAILVARRNAL:
A. USES KEV TO UNLOCK DOOR
B. DISARMSALARMATKEYPADLOCATEDJUSTINSIDEREARENTRANCE
� DETEXALARMATREARENTRANCESHALLALWAVSREMAINONANDACTIVE
A. MANAGERSHALLONLYDISARMDETEXALARMTOALLOWDELNERIES
THROUGHOUTTHEDAV
• PUSHBUTTON ON THE EMERIOR OF THE REAR ENTRANCE W HEN PUSHED
SHALL EMIT SOUND VIA BUZZERS LOCATED AT'.
A. BACKWRAP
B. BACK OF HOUSE
-5r
L� � _ Si
���,� , ,
C /
F
_ I� —
"�__ _ I..IIII I� I��I III �I�� __ -.
" I I I "�
I IIIIII IIII I lil
G
GLG � �
-- I iiJ g-ig
=- Ild L
���� �'�� I
��
e-z�
� E04 �
I�
�
� E04 � �
B-2�
r=
- L
II �I ' 6
� CLG�
__- qllil '��I�i I� B 42 ..
CLG:u.
�� B 43 6
�
�
H
W
r
�
U
w
U
Q
d'^
Vl
W
Q
4 �
w
�
�
Q
J
U
5
N
0
�
a
Z
J
W
�
�
a
U
❑
>
m
w
¢
�
�
w
t� ~
� Q
O U
0
y �;
� a
�
(�
z
0
0
m
~ N
� m
� y d' O�i
Y � d m
O
w O F O
O
z o o w m
� rc � w o
�aN��w
� Q N 0 4 IL
Z
s Q
� J
za
¢ cn
��
wW
H
O�
a�
E201