Loading...
HomeMy WebLinkAbout19120125 Building PlansGENERAL PROJECT NOTES I. BUILDINGCODECOMPLIANCE:ALLwORKSHALLCOMPLYwIiHiHE REQUIREMENTS OF THE EXISTI NG BUILDING CONSTRUCTION iVPE AS DEFINED BY SEQION 601 OF iHE INDIANA BUILDING CODE AND ALL APPLICABLESiAiE AND LOCAL BUILDING CODES. CONiRACiORS ARE RESPONSIBLE FOR VERIFVW G THE Cl1RRENT APPLICABLE Bl11LDW G CODE S �) FOR iHEIR RESPEQIV E SCOPE OF W ORK ENSURE iHAi ALL MAiERIALS AND LABOR ARE IN ACCORDANCE wliH iHE BESi QUALIiY SiANDAR0.S OF EACH RESPECTIVE TRADE WHETHER SPECIFlED OR NOT. THE GENERAL CONiRACiOR I$ RESPONSIBLE FOR ENSURING iHAi ALL W ORK I$ IN ACCORDANCE wliH ALL FEDERAL, SiAiE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL MECHANICAL AND ELECTRICAL CONARUCiION_ 2. CONiRACiOR SIiE VISITS: CONiRAQOR�S) SHALL VISIi iHE WORKSIiE PRIOR TO COMMENCEMENT. THE DRAW WGS CONTAW ED HEREIN MAV NOiBEALLINCLUSNEOFE%IAWGCONDIiIONSORNEW WORK REQUIREMENTS. CONTRACTOR�S�SHALLMAKETHEMSELVESFAMILIARWITH THE W ORK SITE IN THE FlELD I N ORDER TO BE Fl1LLV AW ARE OF THE REQUIREMENiS OF iHE SCOPE OF W ORK. 3. CONiRACiOR FIELO VERIFICAiION: FlELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. WFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSiRUCiION IF EXISiING CONDIiIONS PREVENi OBiAINING RESULiS AS SHOwN OR SPECIFIED. DO NOi SCALE DRAwINGS; NOTED DIMENSIONS TAKE PRECEDENCE VERIFV E%ISTWG CONDITIONS INDICAiED ON iHE DRAW WGS AND REPORi ANV DISCREPANCIES iHROUGH iHE GENERAL CONiRACiOR i0 SCHOii DESIGN, W C. 4. GENERALCONiRACiORCOORDINAiIONWIiHOWNER:THEGENERAL CONiRACiOR SHALL COORDINAiE W IiH iHE OW NER REGARDW G ALL ONSIiE ACiI VIiIES SUCH AS, BUi NOi LIMIiED i0: wORK SCHEDULE, MAiERIALS SiORAGEAND HANDLING, DELIVERIES, ACCESS i0 iHE WORK SITE TRAFFlC CONTROL AND Bl11LDING/Pl1BLIC SAFEiV PROCEDl1RES DURING CONSiRUCiION_ iHE CONiRAQOR SHALL ALSO COORDINAiE WORK "BY OiHERS" WIiH HIS/HER OW N AQIVIiIES PS NECESSARY i0 EXEC UTE THE OV ERALL PROJECT SCOPE THE GENERAL CONTRACTOR SHALLCOORDINAiE WIiHiHE UNDLORD, DAILV WORKWGHOURS. wEEKEND HOURS AND HOURS iHAi MAY BE wORKED PRIOR i0 AND DURING HOLIDAVS. LANDLORD RESERVES THE RIGHTTO RESTRICT CONARUCiION i0 NIGHiS AND W EEKENDS W HEN iHAi CONARUCiION IS DEEMED i0 INiERFERE wliH iHE OPERAiIONS OF ADJACENi iENANiS. 5. PROJECiMAiERIAL LEAD iIMEt FOR THOSE ITEMS TO BE ORDERED REQl11RW G LEAD TIME THE CONTRACTOR SHALL COORDINATE THE PROJEQ SCHEDU LE ACCORDINGLY AND COMMUNICAiE i0 iHE O W NER, iENANi, AND SCHOii DESIGN W HEN DECISIONS MUSi BE RENDERED I N ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDl1LE THE OW NER, iENANi, OR DESIGNER/ARCHIiECi IS NIN RESPONSIBLE FOR DELAYS RESULiING FROM iHE CONiRACiORS FAILURE i0 COMMUNICAiE MATERIAL LE4D TIMES. 6- MAiERIAL5UB5iliUilONS: SUBAIiUiIONS FOR SPECIFlCALLV NAMED PRODUCiS WILL NOi BE ALLOWED WIiHOUi PRIOR APPROVAL FROM iHE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS W ITH APPROPRIATE Sl1PPORT I NFORMATION TO THE DESIGNER. ALLOW REASONABLV SUFFlCIENi iIME FOR iHE DESIGN ER i0 REVIEW iHE REQUESi AND RENDER A DECISION. ]. SAFEWORKAREA:SCHOTfDESIGN,INC.,SHALLNOTHAVECONTROL OVER, BE W CHARGE OF, OR BE RESPONSIBLE FOR A CONiRACiOR'S CONSiRUCiION ME4NS, MHHODS, SCHEDULES, SEQUENCES, OR SAFHY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMEM FOR WORKERS AND iHE PUBLIC Ai ALL iIMES_ 8. GENERALCONiRACiORCLEANUPPROCEDURES:iHEGENERAL CONiRAQOR SHALL ESiABLISH W IiH iHE LANDLORD QE4NUP PROCEDURES AND GUIDELW ES TO BE FOLLOW ED ON A DAILV BASIS IN ORDER i0 CONDUQ BUSINESS IN A SAFE AND CLEAN ENVIRONMENi. 9. SiAGING/PARKING/OUMPSiERS/RESiROOMS:iHEGENERAL CONTRACTOR SHALL COORDINATE W ITH THE LAN DLORD AN AREA FOR SiAGI NG OF CONSiRUQION MAiERIALS, EQUIPMENi, DUMPSiER AND PARKING CONSiRUQION AND DELNERY VEHIQES. iHE USE OF EXISiING RESTROOM FACILITIES SHALL BE APPROVED BV THE LANDLORD.ONLV iHOSE DESIGNAiED AREAS SHALL BE USED BV CONARUCiION CREWS- 10. DUSiCONiROL:iHEGENERALCONiRACiORSHALLUSEDUSi PARTITIONS TO MINIMIZE DISTl1RBANCES OF DAI LV TENANT OPERATIONS DURWG DEMOLIiION AND CONARUCiION WORK_ DUA PARiIiIONS SHALL BE CONSiRUQED OF 2X4 WOOD SiUDS s 24"O.C., INSULAiION AND 6 MIL VAPOR BARRIER ON EACH SIDE. II. PROJECiINSiALLAiIONCONFLICiS:CONiAQiHEDESIGNER IMMEDIAiELY IF CONFLICiS ARE DISCOVERED IN iHE FIELD BEiwEEN COMPON ENTS OF DIFFERENT SVSTEMS THAT PREV ENT THE WSTALLATION OF iHOSE COMPONENiS AS INDICAiED ON iHE DRAwINGS. �LE. wHERE EXISiING MECHANICAL DUCiWORK MAY PREVENi iHE INSiALLAiION OF LIGHiING FIXiURES AS INDICAiED ON iHE CEILING PUN�. 12. SCHOiT DESIGN HAZARDOUS MAiERIALS WAIVER: SCHOii DESIGN, INC., IS NOT RESPONSIBLE FORTHE IDENTIFlCATION, DISCOVERV, PRESENCE HANDLWG. REMOVAL DISPOSAL OF, OR E%POSURETOANV PERSONS, iHAi OF HAZARDOUS MAiERIALS IN ANY FORM ON iHE PROJECT SITE. 13- WOOD BLOCKING IN WALR: PROVIDE FlRE-iREAiED WOOD BLOCKING IN WALLS FORALL WALLHUNG IiEMS WCWDING MILLWORK, WALLSiOPS, CABWHRY, HC. 14. SHOPDRAWINGS:SHOPDRAWWGSORCATALOGCl1TSMl1STBE SUBMIiiED i0 SCHOii DESIGN, INC- FOR APPROVAL ON ALL MAiERIAL$ OR IiEMS wHERE iHE CONiRACiOR CHOOSES i0 DEVIAiE FROM wHAi IS SHO W N ON THE DRAW INGS OR IF THE DRAW INGS DO NOT INDICATE A SPECIFlC MANUFAQURER OR MODEL NUMBER. EXPEDIiE PREPARAiION AN D SUBMIiiAL OF ALL SHOP DRAwINGS i0 ALLOw SUFFICIENi iIME FOR CHECKING, APPROVAL, ORDERING, FABRICAiION, AND DELNERY OF MATERIALS AND EQUIPMENT. I5. PROJECiAPPROVALS:ALLDEiAILS,MAiERIALS,ANDINSiALUiIONS ARE SUBJEQ i0 FlRSi APPROVAL BY SCHOii DESIGN, INC., AND FlNAL APPROVAL BV THE OW NER. 16. CHANGEORDERS:REVIEWANDCOORDINAiEALLNEWWORKAND EXISiING CONDIiIONS wliH ALL OiHER iRADES. FIELD wORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANV CONDITIONS OR CONFLICiS iHAi COULD HAVE BEEN ACCOUMED FOR BV iHE BIDDER DURING PRE-BID FIELD INSPECiION AND AFiER AwARD OF CONiRACi. V. FURNIiURE AND EOUIPMENiEXCLUSIONt FURNITURE OFFlCE EQUIPMENi, OFRCE PARiIiION SVAEMS. REFRIGERAiORS. VENDWG MACHINES, AND OiHERSIMILAR IiEMS SHOwN DASHED ON iHIS DRAwING AND NOi AiiACHED i0 iHE BUILDINGARE f-0R REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE W ORK 11NLESS SPECIFlCALLV SiAiED i0 BE PROVIDED. I8. WALLPAiCHING:PAiCHALLGYPSUMWALLBOARDAiAREASOF ELECTRICAL DATA AND SW ITCH DEVICES BEWG REMOVED. PATCH HOLE RELEASED FOR CONSTRACTION °RE FOR F'"'S" Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ onrE: 01 /13/20 19. CONSiRUCiIONCLEANING:EXECUiEAiHOROUGHFINALCLE4N AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXiURES, AND EQUIPMENi SHALL BE CLEAN, AND iHE SPACE SHALL BE iURNED OVER i0 iHE OwNER IN A CONDIiION iHAi REPRESENiS iHE HIGHESi LEVEL OF CAREAND PROFESSIONALISM. ENSUREALL GENERAL CONTRACTOR INSTALLED APPLIANCES W ORK & DO NOT LEAK_ 20. O 8 M MAiERIALS: PROVIDE i0 iHE OW NER ALL OPERAiION AND/OR MAINiENANCE MANUALS, OR INSiRUCiIONS FOR ALL EQUIPMENi AND SVSTEMS AT THE COMPLETION OF THE PROJECT. 21. PLANDIMENSIONS:ALLPLANDIMENSIONSAREFROMFACEOF EXISiING FINISH i0 FACE OF NEw GYPSUM BOARD wALL, OR FACE i0 FACE OF NEW GVPSl1M BOARD WALL DO NOTSCALE DRAWWGS. WRIiiEN DIMENSIONS GOVERN_ 22. WINDOW BLINDS CONiRACiOR i0 PROVIDE AN ALLOwANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANV DAMAGED OR MISSWG WINDOW BIJNDS WIiH NEW i0 MAiCH BUILDWGAANDARD_ 23. PERMIIIING:iHEGENERALCONiRACiORSHALLBERESPONSIBLEFOR VERIFYINGiHE REQUIREMENiS REGARDING LOCAL PLAN REVIEW, PERMIiS, INSPECTIONS AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMIiiWG ALL REQUIRED DRAW WGS AND SUPPORiING DOCUMENiS i0 iHE LOCAL BUILDI NG OFFlCIAL AND/OR PERMIT DEPARTMENT. ALL REQl11RED LOCAL PERMIT FEES SHALL BE PAID BV iHE GENERAL CONiRACiOR UNLESS AIPUUiED OiHER W ISE IN iHE OwNER/CONiRACiOR AGREEMENi. 24. FIRESEALINGFlRESEALALLPENETRATIONSTHROUGHRATEDWALLS, FLOORS. AND CEILWGS WIiH APPROVED FlRE-RAiED CAULK AS DIRECiED BY LOCAL JURISDICiIONS. CONiRACiOR i0 BE AWARE iHAi EXISiING CON DIiIONS ARE NOi N ECESSARILY AN INDICAiOR OF BUILDING iYPE. BUILDWGiVPE LIAED ON LIFESAFHV PLAN IS BASED UPON AVAIUBLE INFORMAiION AND FIELD VERIFICAiION. 25. WALLPENEiRAiIONS:WHERESiRUCiURALBEAMS,DUQWORK,HC. PENETRATE SOUND OR FlRE RATED PARTITIONS GVPSUM WALLBOARD WALLiO BESCRIBE9 i0 Ri iIGHi, CAULKED AND RRE DAMPERED IF REQUIRED. 26. FLOORLEVELING:CONTRACTORTOALLOWFORl1NLEVELFLOOR CON DIiIONS_ ALL E%IAW G FLOOR AN D W ALL SUBARAiES SHALL BE LEVELED AND PAiCHED AS REQUIRED i0 RECEIVE NEW CONSiRUQION AND FlNISHES. ADJUST DOORS AND FRAMES AS REQUIRED. 2J. REPAIR GYPSOM WALLBOARD: REPAIR GVPSl1M WALLBOARD WHERE DEMOLIiIONHASOCNRREDAiREMAININGWALLS. REPAIRANY GYPSUM BOARD DAMAGED BY DEMOLIiION. PROVIDEEXPANSION JOINTS IN DRVWALL W HERE NE W W ALLS MEET OR ADJOIN TO E%ISTWG CORE WALLS. 28. EOUIPMENiINSiALLAiION:ALLEQUIPMENiAND/ORFIXiURESSHALL BE INSTALLED IN STRICT ACCORDANC E W ITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS- FINISH NOTES L SiAiE BUILDING COMPLIANCE FOR FINISHES: ALL FINISHES SHALL COMPLVWITHCHAPTERB �IMERIORFlNISHES�OFTHEINDIANABl11LDWG CODE FOR CLASS A FIRE RAiINGS. 2. GYPSUMASSOCIAiION CONFORMItt: FOR ALL NEw DRYwALL WSTALLATIONS WSTALL AS RECOMMEN DED BV THE GVPSl1M ASSOCIATION �SUCH AS, CONiROL JOINiS, FINISH LEVELS, FASiENERS, iAPING DEiAILS, CORNER BEADS EfC.�. PROVIDE NEW CEMENT BACKER BOARD AS A SUBSiRAiE FOR NEW WALLiILE PER MANUFAQURER'S RECOMMENDAiIONS. 3. COVER PLAiES: REFERENCE RERECiED CEILING PLAN AND ELECiRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEV ICES AND PLATES. REMOVE ALL PLAiES BEFORE PAINiING AND REINAALL AFiERWARD. CONiRACiOR i0 CONFIRM DESIRED COLOR PRIOR i0 PURCHASING N Ew. 4. PAINiING:ALLAREASRECEIVINGPAINTARETORECENE PRIMERCOAT AND iW0 �2) FINISH COAiS 5. FLOORING iRANSIiION SiRIP4 FOR CHANGE W FLOOR FlNISH MATERIAL PROVIDE TRANSITION STRIP AT DOOR OPENWGS AS NOTED ON FINISH PLAN UNLESS NOiED OiHERwISE �LE. wHERE VCi MEHS CARPH�. 6. DELNERV OF COMPREHENSNE WORK PRODUCi: WHERE LIMITS OF WORK ARE SHOWN, OiHER INCIDENiAL WORK LIKE PAINiWG WHERE NEW OUiLHS HAVE BEEN INSiALLED, IS CONSIDERED PARi OF iHE SCOPE OF WORK_ PROVIDEACOMPLHEANDFlNISHED PRODUQRE4DYFORiENANiAND Bl11LDWG OWNER. ]. WALL�EMOLIiION:REFINISHSURFACESiOMAiCHEXISiINGWHERE DEMOLIiION HPS OCCURRED. REPAIR GYPSUM wALLBOARD wHERE DEMOLITIONHASOCCURREDATREMAININGWALLS. REPAIRANVGVPSUM BOARD DAMAGED BY DEMOLIiION_ PROVIDE EXPANSION JOINiS IN DRYwALL wHERE NEw wALLS MEEi OR ADJOIN i0 EXISiING CORE wALLS. 8. PHONE BOARDS: WHERE PHONE BOARD IS PROVIDED, PAINT BOARD W ITH FlRE RETARDANT PAINT TO MATCH ADJACENT WALL FlNISH. 9. MILLWORKSAMPLES:SUBMIiFlNISHSAMPLEOFMILLWORK�SiAWEDOR PAIMED AS SPECIFlED) i0 SCHOii DESIGN FOR REVIE W AN D APPROVAL PRIOR i0 iHE FINISHING PROCESS OF ALL MILLwORK. 10. INiERIOR ELEVAiION DEiAIIS: REFERENCE INTERIOR ELEVATION & SECTIONS W HERE PROV IDED FOR ADDITIONAL FlNISH W FORMATION. II. PAINiBA�HE5IVEVOCS:ALLPAINiSANDADHESIVES/SEALANiSSHALL HAVE ZERO VOC CONiENi. 12. ADHESNEMANOFAQORERRECOMMENDAilONS:ALL ADHESIVES/SEALANiSiO BE USED AS RECOMMENDED BY PRODUQ MANUFACiURER. EFFECTIVE CODES GENERAL ADMINISTRATNE RULES �6J5 IAC 12) I NDIANA BUI LDING CODE, 2014 EDIiION �IBC, 2012 EDIiION, 6]51AC 13-26) HANDICAPPED ACCESSIBILIiV CODE:20141NDIANA BUILDWG CODE CHAPiER I I,ANSI AI pJ-2009, 6]51AC I&2.6-12) IN DIANA RRE CODE, 2014 EDIiION �IFC 2012 EDIiION, 6]51AC 22-25) INDIANA PLUMBING CODE 2006 EDIiION �6I51AC 16-1.4) INDIANA ELECiRICAL CODE, 2009 EDIiION �2008 NFPA ]0, 6]51AC V-I.B) INDIANA MECHANICAL CODE, 2014 EDIiION �IMC, 2012 EDIiION, 675 IAC IS-Ib) ENERGY CONSERVAiION CODE, 2010 �ASHREA 90.1, 2007 EDIiION, 6IS IAC 19 3) MECHANICAL & ELECTRICAL NOTES I. M/E/P: iHE MECHANICAL ELECiRICAL AND PLUMBINGSCOPES OF WORK ARE LIMITED TO BASIC DESIGN-Bl11LD ALTERATIONS WHICH ARE OUiLINED IN iHESE PUNS. iHE DESIGN-BUILD CONiRAQORS FOR EACH iRADE MUSi NOiIFY iHE ARCHIiECi IF iHEY FIND iHAi iHESCOPE OF W v ORK EXCEERS iHE LE EL OF MECHANICAL ELEQRICAL OR PLUMBING WORK INDICAiED ON iHESE DRAW WGS SO iHAi ANV NECESSARV ENGWEERING CAN OCCUR AND ADDIiIONAL PLANS CAN BE FILED, OR IF ADDIiIONAL I NFORMAiION IS NEEDED IN ORDER i0 COMPLHE iHE W ORK IN THE RELD. STATE BUILDING CODE THE CONTRACTOR�S) SHALL PROVIDE DESIGN/Bl11LD DRAW WGS FOR MECHANICAL PWMBWG, ELECTRICAL OR FIRE SUPPRESSION_ DRAWINGS SHALL BE CERiIFIED BY A LICENSED ENGW EER AND SUBMIiiED BY iHE CONiRACiOR FOR SiAiE DESIGN REVIEw. 24. Ep01PMENiINSiALLAilONS:ALLEQl11PMENTAND/ORFl%Tl1RES $HALL BE INSiALLED IN $iRICi ACCORDANCE WIiH iHE MANUFACiURER'S RECOMMENDAiIONS OR INSiRUCiIONS. 2 HVAC: MECHANICAL WORK IS LIMIiED i0A DESIGN-BUILD SCOPE AND IS OUiLWED IN iHESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAW EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL W ORK IS LIMIiED i0 RELOCAiION OF DIFFUSERS AND FLE% DUCi PER NEW WALL LAYOUi. MECHANICAL CONiRACiOR IS i0 NOiIFY APPLICABLE PARTIES IF ADDITIONAL W ORK IS REQUI RED SO THAT ADDIiIONAL PLANS CAN BE FlLED AN D MUA COMPLV W IiH iHE INDIANA MECHANICAL CODE AND ALL OiHER APPLICABLE CODES. 3. HVACHEAiLOADS:VERIFYHE4iLOARSOFANYSPECIAL EQUIPMENT IN THE TENANT SPACE AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED_ CONFIRM W IiH O W NER PRIOR i0 ANY PURCHASE OF NEW EQUIPMENi. REVISEZONINGIFREQUIRED.CONiRAQORiOENSURE THAT ALL HVAC ZONES ARE LOCATED APPROPRIATELV Sl1CH THAT NO SPLIi ZONES ARE IN OFFlCES OR CONFERENCE ROOMS UNLESS APPROVED BY BUILDING OwNER/LANDLORD. 4. HVAC DIFFUSER LOCAiIONS: RELOCATEAIR-SUPPLV DIFFUSERS AND RHURN-AIRGRILLESASREQUIRED_ PROVIDEPROPERAIRSUPPLVFOR DIFFUSERS AND REiURN AIR FROM REiURN AIR GRILLES. CONiRACiOR SHALL PLACE DIFFUSERS AND RHURN AIR GRILLES AS REQUIRED BY CODE. 5. HVAC iHERMOSiAi LOCAilONS: POSIiION ALLiHERMOSiAiS WHEREAPPROPRIAiE PER MECHANICAL DESIGN. COORDINAiE W IiH TENANT AND Bl11LD W G OW NER FOR Fl1RNITl1RE PANEL OR OTHER CONFLIQS. 6. ELECiRICAL: ELECiRICAL wORK IS LIMIiED i0 A DESIGN-BUILD SCOPE AND IS OUTLW ED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS IJMIiED i0 ADDIiIONS OR RELOCAiIONS OF ELECiRICAL OUiLH DEVICES AND LIGHiINGiHAi DO NOi EXCEED iHE CAPACIiY OFiHE EXISTING ELECTRICALSERVICE IN THE BUILDING. ELECTRICAL CONiRACiOR IS i0 NOiIFV APPIJCABLE PARiIES IF ADDIiIONAL W ORK IS REQUIRED SO iHAi ADDIiIONAL PUNS CAN BE FlLED AND MUSi COMPLY W IiH ALL APPLICABLE CODES. ]. ELECiRICALCODECOMPLIANCE:COMPLYWIiHiHEINDIANA ELECTRICAL AN D MECHANICAL CODE AND ALL OTHER APPLICABLE CODFS. 8. ELECiRICALCIRCUIiING:SIZEANDQRCUIiELECiRICALPOWER ITEMS. PROVIDEORREUSEELECTRICALPOWERANDDATAOUTLETSAS REQUIRED_ 9_ GFCIOUiLEiS:ALLELECiRICALOUiLEiSWIiHIN6'-0"OFWAiERARE i0 BE GFQ. 10. PHONEANDDAiAACCOMMODAilONS:ATEACHPHONE/DATA A V i A V i X i A i' J CK,PRO IDEPULLS RINGFROM BO ECEILING OBO . EN N S DAiA CONiRACiOR IS RESPONSIBLE FOR PULLING CONDUCiORS AND PROVIDWG APPROPRIATE TERMINALS AT FACE PLATE. IL ELECiRICALSWIiCHPLAiES:PROVIDECOLOREDFACEPLAiESFOR ELECiRICAL OUiLEiS &SwIiCH PLAiES i0 MAiCH EXISiING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FlELD VERIFV PRIOR TO PURCHASE. 12 WORKSiAiIONPOWER:PROVIDEJUNCilONBO%ESORPOWER POLES Ai wORKSiAiIONS wHERE SHOwN. REFER i0 iHE PLAN FOR iHE APPROPRIATE DESIGNATIONS. DATA W ILL BE RU N BV THE TENANTS DATA VENDOR ELECTRICIAN TO MAKE FlNAL CONNECTION FROM W ORKSiAiION W HIP i0 JUNQION BOX_ iHE FURNIiURE V ENDOR IS RESPONSIBLE f-0R W IRING iHE BPSE PANELS OF iHE W ORKSiAiIONS. CONTRACTOR TO COORDINATE W ITH TENANT ON W ORKSTATION FURNIiURE SPECIFICAiIONS i0 OBiAW CIRCUIiRY REQUIREMENiS PRIOR i0 RUNNING ELECiRICAL CONDUIiS i0 JUNCiION BOXES. 13. LIGHiING CIRCUIiS: VERIFV EXISTING LIGHTING CIRCUITING; SIZE NEW CIRCUIiS AS REl3UIRED_ PROVIDE NEW OR REVISE E%IAWG CIRCUIiING FOR NEw LAYOUi OF LIGHi FIXiURES. 14. ELECiRICALOUiLETS:ENSUREiHAiALLMOUNiINGHEIGHiSOF ELECTRICAL DEVICES MEEf ADA REQUIREMENTS- I5. LIGHiINGSWIiCHPLAiES:WHEREMULiIPLESWIiCHESARESHOWN, PROV IDE � I � GANG BOX W ITH A SINGLE COVER PLATE. 16- FIXiURE PLACEMENi: CEMER CEILWG ELEMEMS IN CEILWG iILES. WCLUDING RECESSED DOwN LIGHiS,SMOKE DEiECiORS,SPRINKLER HEADS AND EXIT SIGNS 11NLESS OTHERW ISE NOTED. I]. EMERGENCY LIGHiING: PROVIDE EMERGENCV LIGHiWG IN iENANi SPACE AS REQUIRED PER NEMA AND IBG EMERGENCY BAiiERY PACKS OR LIGHiS CONN EQED i0 AN EMERGENCY POW ER SOURCE ARE REQl11RED IF THE SPACE CONTAINS 50 PERSONS OR MORE Fl%Tl1RES SHOW N ON PUN ARE FOR REFERENCE ONLY_ I8. FIREALARMSVSiEM:HRESUPPRESSIONANDRREALARMSYSiEMS SHALL BE INSTALLED BV THE APPROPRIATE DESIGN-Bl11LD CONTRACTOR AND MUSi COMPLY W IiH ALL APPIJCABLE SiAiE AND LOCAL BUILDING CODES. RRESUPPRESSION AND RREALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FlLINGTHEIR PLANS AND OBTAINWG THEIR PERMITS- PROVIDE ALARM NOTIFlCATION APPLIANC ES �HORNS/SiROBES�, EMERGENCY SPE4KERS, SMOKE DETECTORS FlRE Pl1LLS AND ANV OTHER REQl11RED ALARM & DEiECiION $YSiEM$ A$ NECE$$ARY i0 MEEi ALL APPLICABLE CODE$ �INTERNATIONAL BUILDING CODE INTERNATIONAL FlRE CODE NFPA�. 19. FIRE ALARM DEVICE LOCAilONS: COORDINAiE WIiH OWNER/iENANi PRIORiOINSiALLAiION OF FIRE DEiECiION DEVICES REGARDINGALL DEVICE LOCAiIONS iOAVOID CONFLICi WIiH FEAiURE WALL$ �CONFERENCE ROOMS AND RECEPiION AREAS) AND iENANi-INSiALLED IiEMS �LE PRESENiAiION BOARRS, A/V EQUIPMENi AND PROJECiION SCREENS�- FAILURE i0 DO SO MAY RESU Li IN CONiRACiOR RELOCAiI NG iHESE IiEMS Ai iHEIR EXPENSE. 20. EXISiING LIGHi FIXiURE RELAMP: IF REQUIRED, AND AS NECESSARV, PROVIDE NEW BALLAAS AND UMPS IN ALL IJGHiS W E%IAWG SPACES_ CONSULi wliH LANDLORD. 21. HVAC CONiRACiOR AIR BALANCE: CONTRACTOR TO PERFORM AIR BAUNCE UPON COMPLHION OF HVAC SCOPE PROVIDE REPORi i0 LANDLORD. 22 HVACFLEXDUCEFLEXDUCTMUSTMEEfASHRAESTANDARD Bl11LDW G CODES FOR FLE% Dl1CT LENGTH. 23. ENGMEERE�MEP�RAWINGS:iHEMECHANICAL,ELEQRICALAND PLUMBING DESIGN-BUILD CONiRACiORS SHALL COMPLY wliH ALL APPLICABLE STATE AND LOCAL Bl11LDING CODES. W HEN REQl11RED BV FIRE PROTECTION NOTES I. FIREEXiINGUI5HER5:CONTRACTORTOENSUREALLNEWAND E%ISTWG FlRE E%TWGl11SHERS ARE INSTALLED ACCORDWG TO NFPA 10. COORDINAiE W IiH OW NER/UNDLORD ON E%iW GUISHER iVPE AN D HOUSING. MAXIMUM iRAVEL DISiANCEOF]5 FEH FROMANY POINi TO A VISIBLE E%TWGl11SHER. iHE FOLLOWING NOiES APPLY ONLY W EXISiINGSPRWKLERED FACILIiIES- 2. OESIGN BUILO FIRE PROiECiION SYSiEM: FIRE PROiECiION wORK IS TO BE PROVIDED BV DESIGN/BUILD SERVICES UNDER THE GENERAL CONiRACL PROVIDE A COMPLHE WORKWG SVAEM_ SCHOii DESIGN, WG IS NOi RESPONSIBLE FOR iHE DESIGN, INSiALLAiION, OR RENOVAiION OF iHE FlRESPRINKLERSYSiEM. 3. FIREPROiECilON5Y5iEMCODECOMPLIANCE:THEDESIGN/Bl11LD CONiRAQOR SHALL COMPLY W IiH iHE I NDIANA BUILDING CODE, iHE INDIANA FlRE CODE AND ALL OiHER APPLICABLE LAWS, CODES, RULES AND REGl1LATIONS THATAPPLVTO DESIGN AND WSTALLATION OF FlRE SPRWKLER/RRESUPPRESSION SVAEMS- 4. FIRE PROiECiION DESIGN DRAWINGS: iHE FIRE PROiECiION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAW INGS AND SHALL RLE iHOSE DRA W WGS. AN D REUiED DONMEMS. W IiH iHE SiAiE AND LOCAL AUiHORIiIES HAVING JURISDICiION OVERiHE PROJECi. 5. SPRINKLERHEADS:PROVIDENEWORRELOCATEE%ISTWG SPRINKLERHEADSASREQUIRED. PROVIDEMISSING COVER/ESCUiCHEON PLAiES FORSPRINKLER HE4DS WHERE APPLICABLE FlELDVERIFVE%ISTINGCONDITIONSPRIORTOTHESTART OF W ORK. MILL/CASEWORK NOTES I_ CASEWORK/MILLORK:CASEWORKANDMILLWORKGENERALLY INDICAiED ON iHESE DRAwINGS AREiO BE PROVIDED UNDER iHE GENERAL CONTRACT. 2. AWICOMPLIANCE:l1NLESSINDICATEDOTHERWISECOMPLV W IiH ARCHIiEQURAL W OODW ORK INSiIiUiE �A. W.I.) CURRENi STANDARDS FOR CUSTOM GRADE WOODWORK. 3. MILLWORKSHOPDRAWINGSFURNISHSHOPDRAWWGSONALL MILLwORK AND CASEwORK FOR APPROVAL BY iHEiENANi AND SCHOTf DESIGN PRIORTO FABRICATION. 4. MILLWORKFIELDVERIFICAiION:WHERECASEWORKAND MILLwORK AREiO BE INSiALLED, VERIFY ALL DIMENSIONS ON PLANS AGAI NST DIMENSIONS OF AS-BUILT CONDITIONS W FlELD. REPORT ANV DISCREPANCIES i0 SCHOii DESIGN iHROUGH iHE GENERAL CONiRAQOR_ MAKEADJUSiMENiSiOCASEWORKANDMILLWORK i0 Ri RELD CONDIiIONS UNLESS DOINGSO WILLSIGMRCANiLY ALTER THE IMENT OF THE DESIGN SHOWN ON THE DRAW WGS. 5. �RAWING REVIEW AN� �ISCREPANCIES: VERIFY FINISHES �LAMINATE VENEER, STAINS EfC.) ON THE SECTIONS AND ELEVATION DRAW WGS W IiH RNISHES INDICAiED ON iHE HNISH PLAN/SCHEDULES IMMEDIAiEd REPORi ANY DISCREPANCIES i0 SCHOii DESIGN iHROUGH iHE GENERAL CONiRACiOR. 6. MILLWORKREQOIREMENiS:REFERTOMILLWORKSECTIONS& ELEVAiIONS . UNLESS OiHERWISE SHOWN, PUSiIC LAMINAiE CUD COUNiERiOPS wliH 4" BACKSPLASH wHERE INDICAiED, BACKSPLASH TO BE FlELD APPLIED. REFER TO MILLW ORK SECTIONS & ELEVATIONS FOR CABINEiRY SPEQFICAiIONS �CUSiOM PLASiIC LAMINAiE OR PREMANl1FACTl1REDSTOCKCABWEfRV�. EDGESOFPLASTIC LAMINAiE COUMERiOPS, CABWHS AND DRAW ERS i0 BE PUSiIC LAMINAiEAND NOi PVC OR OiHER SiOCK PLPSiIC EDGING UNLESS NOTED OTHERWISE. ]_ MILLWORKWALLBLOCKING:PROVIDEBLOCKWGINWALLSFOR ALL MILLwORK, wALL SiOPS, HARDwARE, AND CABW EiRY wHERE SPECIFlED. ALL WOOD BLOCKINGTO BE FlRE RATED. DOCUMENT APPROVAL DECONSTRUCTION NOTES I. DECONSiROCiIONDEFINIiION:CAREFl1LLVDISMAMLESPACES W IiH iHE GOAL OF MA%IMIZW G iHE REUSE POiENiIAL OF IiS COMPONENiS. 2. RECVCLING: GENERALCONiRACiOR6RESPONSIBLEFOR RECVCIJNG OF ALL CARPH AND MHALS Ai A MINIMUM, AND COORDINAiING iHE APPROPRIAiE HAULING CONiAWERS W IiH iHE WPSiE MANAGEMENi SUB-CONiRACiOR AND KRUSE CARPH RECVCLWG. REFERTODECONSTRl1CTIONDIIISHEETFORSPECIFlC INSiRUQIONS 3. EXISiINGSiRUCiURALELEMENiSOFBUIL0ING:NOSiRUCiURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESUQ OF iH1S PROJECi UNLESS SPECIRCALLYNOiEDOiHERWISEONiHEDRAWINGS. PROiECiALL EXISTING STRUCTURAL MEMBERS DURING DEMOIJiION/CONARUCiION_ iHE CONiRACiOR SHALL V ERIFV IN iHE FIELD, PRIOR i0 DEMOLIiION, iHAi ALL IiEMS NOiED i0 BE DEMOLISHEDARENOiSiRUCiURAL CONiACiSCHOiiDESIGN IMMEDIAiELY IF iHE CONiRACiOR�S) IN iHE FIELD SUSPECi iHAi AN IiEM NOiED FOR DEMOLIiION APPE4RS i0 BESiRUCiURAL OR OTHERWISELOAD-BEARING. BEWAREOFSTRUCTURALCOWMNS AND/OR BEAMS iHAi MAV BE CONCEALED BEHIND FlNISHE$ iHAi ARE NOiED FOR REMOVAL EXERCISE CAUiION wHEN DEMOLISHING BUILDING RNISHES OR PARiIiIONS ADJACENi i0 OR AROUND STRUCTURAL MEMBERS- THE CONTRACTOR IS SOLELV RESPONSIBLE FOR INADV ERiENi DAMAGE i0 iHE BUILDING SiRUCiURAL SYSiEM. 4. EOUIPMENi, FIXiURE, FINISH RE�USE: WHERE EQUIPMENL FlXiURES OR FlNISHES ARE MOVED FROM ANV OTHER PART OF THE Bl11LDWG TO BE REUSED IN iHE PROJECi AREA, iHE CONiRAQOR SHALL WCLUDE IN iHEIRSCOPE OF wORK ANY NECESSARY PAiCHING OR REPAIRING OF THE REMAINING AREAS FROM W HERE THE ITEMS W ERE RELOCATED, UNLESS OiHERW ISE DIRECiED BY OWNER. 5. DECONSiRUCiION PLANS: REMOVE ALL EXISiING wALLS AND DOORS WHERE INDICATED BV NOTE SVMBOL OR DASHED LWES. NOiE iHAi SOME IiEMS HAVE NOi BEEN SHOWN ON DECONSiRUQION PUN_ VISIi AREA OF WORK i0 ASSURE EXiENi OF DECONSiRUCiION. 6. FIELD VERIFICAiION OF EXISiING CONDIilONS: REMOVEALL CARPEi, VINYL BASE, VQ, W ALL FABRIC, AN D ANY OiHER FINISHES AS REQUIRED FOR NEW CONSiRUQION. CONiRAQORiO FlELD VERIFY E%ISTWGCONDITIONS. REFERTOFlNISHPLAN/SCHEDl1LEFOR CURIRCAiION OF E%IAWG RNISHES i0 REMAIN_ ]. PROiECiIONOFBUILDINGELEMENiSiOREMAIN:USECAREiO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS i0 REMAW SUCH AS. BUi NIN LIMIiED i0. E%IAWG CEILWG GRID, iILES, FIRESUPPRESSION EQUIPMENi, DIFFUSERS, LIGHi FIXiURES, EQUIPMENi, CASEWORK, AND RNISHES. iHE CONiRAQORSHALL REPLACE AND/OR REPAIR AT THE CONTRACTOR'S COSL ANV Sl1CH ELEMENiS DAMAGED DURING CONSiRUQION iHAi COULD HAVE OiHERW6E BEEN REASONABLY PROiEQED AND MAINiAWED IN GOOD CONDITION FOR THE OW NER S 11SE IN THE PROJECT. 8. REMOVALOFABAN�ONEDCABLINGBWIRING:PERiHEINDIANA ELECiRICAL CODE �SPREAD OF FlRE OR PRODUQS OF COMBUSiION) REMOVE ALL ACCESSIBLE PORiIONS OF ABANDONED CABLES AND WIRIN W L DIN B iN iIJMIiEDi _DAiAWIRIN G C U G U O O G, COMMUNICAiIONS WIRING, HREALARM CABLES, AUDIO CABLES, COA%IAL CABLES FlBER OPTIC CABLES/RACEWAVS AND PLTC CABLE$_ REFER i0 $ECiION 300 21 _ ANY $UCH CABLE OR W IRING SHOULD BE PULLED AND REMOV ED BACK i0 iHEIR MAI N SOURCES ON THE FLOOR �1 E ELECTRICAL PANELS. PHONE BOARDS ETC-) 9. PROiECiIONOFABANDONED/iERMINAiEDBUILDING5Y5iEM ELEMENiS: WHERE FlXTURES OR EQUIPMENTARE REMOVED FROM ANV ELECiRICAL PLUMBWG. MECHANICAL OR VOICE/DAiA SVAEMS. ALL REMAINING iERMINAiIONS SHALL BE CLOSED AND PROiECiED IN SiRIQ ACCORDANCE W IiH INDUSiRY SiAN DARRS AN D GOV ERNING SAFEfV REGl1LATIONS OR PROCEDl1RES. MARK, LABEL OR FLAG ALL iERMINAiED SYSiEMS FOR FUiURE REFERENCE. CONiRAQOR i0 PROVIDEAN "PS-BUILi"SH INDICAiING iHELOCAiION OFALL PERMANENTLV ABANDONED SVSTEMS. 10- HAZARDOUSMAiERIALS-GENERALCONiRACiOR IS RESPONSIBLE FOR IDENiIFYING ANY AND ALL IiEMS iHAi MAY CONiAIN HAZARDOUS OR HARMFUL MAiERIALS. ALL IDENiIFlED IiEMS MUST BE PROPERLV DISPOSED OF PER EPA AND INDIANA DEPARTMENT OF ENVIRONMENiAL MANAGEMENi RULES AND REGULAiIONS_ TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAWED IN THESE DOCUMENTS. iENANi/CLIENi COMPANY NAME DAiE iENANiREPRESENiAiIVESIGNAiURE iENANiREPRESENiAiIVEPRINiEDNAME ALL COSTS INCl1RRED Dl1E TO ANV CHANGES REQl1ESTED AFTER SIGN-0FF OF THESE DOCl1MENTS SHALL BE THE Fl1LL RESPONSIBILIiV OF THE iENANi/CLIENi. iHESE DRAwINGS, AND iHE IDEAS, DESIGNS AND CONCEPA CONiAWED HEREIN, ARE iHE EXCLUSNE INiELLECiUAL PROPERiY OFSCHOii DESIGN, ING, AND ARE NOi i0 BE USED OR REPRODUCED IN WHOLE OR IN PARi, W IiHOUi iHE WRIiiEN CONSENi OFSCHOii DESIGN. �, o . � 9 �. _...,:0 n�,w�. 'awr..wansTe� � _ .,, ��... Oca o r . . . , s.�e� Evemsi 0 Q ��o VICINITY MAP NOT TO SCALE O O KEY PLAN - 1ST FLOOR N NOiiOSCALE � INDEX OF DRAWINGS illl COVERSHEHANDGENERALPROJECiNOiES LI00 LIFESAFEiYPLAN DI I I DECONSTRUCTION PLAN Alll ARCHIiECiURALFLOORPUN AI21 REFLECiEDCEILINGPLAN la��il�ilpi�y�a�l A211 DOORSCHEDULE/IMERIORDHAILS EIII ELECiRICALPLAN �i � � •� o � � J � N b O J � Q o � JJ �nZ� - r ^ y m J � .� � . P Qn 7 w p � n O C ,_ `n O p 3 � � 5 C iHIS DRA W ING. AND iH E IDEAS. DESIGNS AND CONCEPiS CONiA W ED HEREIN.AREiHEEXCW$IVE INiELLKiUAL PROPERiY OF SCHOii DESIGN. W C.. AND ARE NOi i0 BE USED OR REPRODUCED IN W HOLE OR IN PARi, wIiHOUi iHE wRIIIEN GONSENi OF SGHOII DESIGN. Q � N � � � � � J�vi W�� W=0 � N Q N � Z Q � � � W�z O Z � � � W�� � JQ? � � � w Q � � ISSUE DAiE DESCRIPiION 11.11.19 REVIEW SEi 11.]6.19 PERMIiSEi REVISIONS MAR DAiE DB DESCRIPiION I��. AR10700017 SiATE OF PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB 1ST FLOOR COVER SHEET AND GENERAL NOTES T111 �i CODE SUMMARY 1 I SCOPEOFWORK I OFFlCEREMODELOFPREVIOl1SLVBl11LT-Ol1TOFFlCESPACE I p PREVIOUSUSEOFSPACE B�l1SWESSf 3 OCCUPANCYCLASSIRCATION B�l1SWESSJ Q CHANGEOFOCCUPANCYCLASSB NO 5 TOTALBUILDINGAREA 24,626 SF/FLOOR X SSTORIES = 123,130SF 5 TOTALPROJECTAREA 4,605 SF � OCCUPANCYCALCULATIONS SPACETYPE AREA SFPEROCCUPANT OCCUPLOAD GEN.OFFlCE 4,605SF 100 36 iOiAL OCCUPANiS IN PROJECi AREA 104 8 9 10 11 12 13 14 15 ifi NUMBER OF EXIiS SPRINKLERSYSTEM �YES/NO� iOiAL AREA OF AGGESSORY USES iOiAL AREA ON iHE FLOOR ACCESSORYAREA EXCEE9S l0% FIRE WALLS, AND/OR OGGUPANGY SEPARATIONS �IF REQUIRED� ASHRAE 90J SUMMARY BUILT BEFORE 19I82 :wnei.�e�wum:u�iwuw�a REOUIRED:2 PROVIDED:3 YES - EXISiING i0 REMAIN 0 SF 2q626 SF NO N/A E%EMPi �SEE REFLECiED CEIIJNG PLANJ NO II-B �PER ORIGINALI6FRJ LEGEND Ep EXISiINGELECiRICALPANELLOCAiION EX exisriNc exir FE IO FIRE EXiINGUISHER Q EXIi51GN ��.nu EMERGENCYLIGHi --- iRAVELDISiANCE EX LIFE SAFETY NOTES I. PROVIDEEMERGENCYLIGHiINGINiENANiSPACEASREQUIREDPER NEMAAND IBG EMERGENCY BATfERY PACKS OR LIGHTS CONNECiED i0 AN EMERGENCY POW ER SOURCE ARE REQUIRED IF iHE SPACE CONiAINS 50 PERSONS OR MORE. FIXiURES SHOwN ON PLAN ARE FOR REFERENCE ONLY. 2 PROVIDEALARM NOiIFlCAiION APPIJANCES �HORNS/SiROBES�, EMERGENCY SPEAKERS, SMOKE DHECiORS, FlRE PULLS, AN D ANY OTH ER REQUIRED ALARM & DETECTION SYSTEMS AS N ECESSARY TO MEEi ALLAPPLICABLE CODES �INiERNAiIONAL BUILDING CODE, INTERNATIONAL FlRE CODE NFPA�. IN RECEPTION AREAS, CONFERENCE ROOMS AND OiHER HIGH PROFlLEAREAS WIiHIN SUIiE, ALL LOCAiIONS OFSUCH DEVICES MUSi BE APPROVED BYSDI OR TENANT PRIOR TO INSTALLATION. FAI W RE TO DO SO MAY RESULT IN CONiRACiOR RELOCAiWG iHESE IiEMS Ai iHEIR E%PENSE. 3. FIREEXiINGUISHERS: CONiRACiORiOENSUREALLNEwAND GENERAL NOTES LI. REFER i0 ARCHIiECiURAL PLAN FOR wALL iYPEAND CONSiRUCiION DETAILS. L2 E%IAWG E%li SIGNS FlRE Pl1LLS FlRE E%iWGl11SHERS ALARM NOiIRCAiION APPLIANCES i0 REMAIN. RROCAiE EXISiING EXIi SIGNS FlRE PULLS, FlRE EXTINGUISHERS AN D ALARM NOTIFlCATIONS AS REQUIRED TO MEETALL LOCALAND STATE CODES. c � .� O Y J � N b O J � Q o � o� �nZ� .— L — I� y � J � .� � . P Qn 7 LL O c� J O c � O p 3 � < C rHis orenwiN�. nNo mE ioEns. oesi�Ns nNo coNcePrs coNrnweo HEREIN. AREiHE ExCWSNE IMELLKiUAL PROPERtt OF SCHOii �ESIGN, WC.. AN� ARE NOi i0 BE useo ore reePreoouceo w wHo�e ore IN PqRi, wIiHOUi iHf wRIIIfN CONSENi OF SCHOII �ESIGN. 0 � N � � oz � J�vi LJJ �, J W�O � N � �/i � Z � � � W�z Z�� W�� � JQ? a � o� w O � � ISSUE DAiE DESCRIPiION 11.11.19 REVIEW SEi 11.]6.19 PERMIiSEi REVISIONS MAR DAiE DB DESCRIPiION O I��. AR10700017 SiATE oF PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB 1ST FLOOR LIFE SAFETY RELEASEU FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ onrE: 01 /13/20 % ■ AREA NOi W CONiRACi AREA OF W ORK LIFE SAFETY PLAN 0 4' 8' 16' � �� � � �� LEGEND E%ISTING TO BE REMOVED E%ISTING TO REMAIN ------ WALL WALL ______ PARiIAL HEIGHi WALL ----- PARiIAL HEIGHi WALL � DOORANDFRAME � DOORANDFRAME -�--r-WINDOW/SIDELIGHi xWINDOW/SIDELIGHi �i —� I�CHLINGGRIDAND �__7__�r iILES 2k2' F:? SUPPLYAIRDIFFUSERS �c_v i�i EXHAUSTFAN Ln� �� �� LIGHTR�TURE �L __ �j FLUORE$CENL 2'%4' r-a ucnrFi�ueE �L_�j FLUORESCENi,2k2' 'j LIGHi Fl%IDRE CAN � LIGHiSWIiCH F^y EXITLIGHT �tP �-� EMERGENCY LIGHi �� ��° ELECiRIC OUiLEi�Sf 0 J) DAiA OR '� COMMUNICATION our�er NINB EXISTING RXTURES THATARE REMOVED CAN BE REUSED IHN GOOD CONDITION. RECYCLING INSTRUCTIONS CO-MINGLE RECVCLING CONiAINER: L CONiAQ WASiE HAULER i0 ORDER iRASH DUMPSiER�S� AS REQUIREDAND (I� COMINGLE RECYCLING BIN FOR THE DEMOLIiION PORiION OF PROJECi ONLV_ SIZE OF CPMWGLE CONiAW ER IS DEiERMW ED BV iHE AMOUNi OF DEMOLIiION � I O-00 YARD CONTAW ERS AVAIL4BLE�. 2 DRVWALLMIISiBEREMOVEDFROMALLMEiALSiIIDSPRIORiO PLACING IN CO-MINGLE CONiAINER. ANY A��E� LABOR COSi WILL BE COVERED BV MEfAL CREDITS RECEIVED FROM WASTE HAULER. 3_ WASiE HAIILER WILL APPLV CREDIi FOR MEiALt OBiAWED IN CO-MINGLE CONiAINER iOWARD$ CONiRAQOR$ OVERALL INVOICE. 4_ DAiA/DNERSION REPORiS ARENOi REQl11RED NORANV LEED PROCESSES OR PAPERWORK. 5. MEiALS:METALSTUDSDOORFRAMESDOORHARDWARE CEILWG GRI0. LIGHi BOX FlXiURES. MEiAL CABWEiS. MEiAL PLUMBING FIXiURES, ELECiRICAL AN� �AiA WIRING/CON�UIi, HVAC COMPONENTS, AND ELEQRICAL/DATA/SWITCH BOXES NON�MEiALS:SHIPPWG/PACKAGWG CARDBOARDS AND PLASiICS, UNiREAiE� WOOD SiUDS AN� iRIM CARPEiRECVCLING: 6_ CONiACiKRIISECARPEiRECVCLINGiOSCHEDIILEPICKIIPOF ALLCARPEi BEING REMOVED (BROADLOOM AND CARPEi iILE�. COORDINATE REQUIREMENTS AND PICK UP W ITH SUSAN SHAFER �31]) 33]-1950. DEMOLIiION CREW IS NOi RESPONSIBLE FOR KRUSE SERVICE FEES AND WILLALSO RECOGNIZEA SAVINGS BY NO LONGER PAVING HAULING/TIPPING FEES ON CARPET �ISPOSAL WIiH WASiE HAULER. ]. KRUSE WILL PROVIDEAN ON-SITE BIN ON DAYS REQUIRED, OR PICK UP IN A BORTRUCK. DEMOLITION CREW IS TO PLACE CARPET DIRECiLV INiO iRIICK OR BIN; DOES NOi NEED i0 BE PALLEfIZED_ CONiRACiOR IS RESPONSIBLE FOR KEEPING BINS CLEAN AN� �RY AS TO NOT CONTAMINATE CONTENTS. 8- KRUSEPICKUPANDRECVCIJNGFEESAREiOBEPAIDiHROUGH SCHOII �ESIGN'S "NO COSi A�� PROGRAM". CARPEi MANUFAQURER IS i0 PAV $I _00 PER SQUARE VARD FOR CARPEi RECVCLWG BV REDIICWG PRICE OF CARPEi MAiERIAL BV $I 00_ FLOORWG CONiRAQOR IS RESPONSIBLE FOR DEDUQWG MAiERIAL PRICEAND PAVWG $L00 PER SQUAREVARD i0 KRUSE SCHOiiXCHANGE: 9. CONTAQSCHOiTXCHANGEBEFOREDEMOLITIONOFITEMSTHAT CANNOiBERECVCLED ORSALVAGEFORLANDLORD_ SCHOIIXCHANGE CONSI�ERS: �OORS, GLASS WIN�OW SYSiEMS, CABWETS, DECORATNE LIGHTS, AND FURNITURE IF ITEMSARE ACCEPiED FOR OIIR INVENiORV, COORDINAiE PICKIIP AFiER DEMOLIiION WIiH CRYSiAL BRAY �31]� ]62-012] Ai SCHOiTRCHANGE AT NO COSTTO THE PROJECT. CONiACi CRYSiAL BRAY (31]) ]64-OID AiSCHOII DESIGN FOR ANV OUESiIONi REGARDING iHE RECVCLING PROCESSES. GENERAL NOTES I_ REFERiOALLDECONSiRIICiIONNOiESONiIiLESHEEiilll_ 2 ALLIiEMSBEINGREMOVEDFROMPROJECiAREAAREiOBE CAREFULLY CONSIDERED FOR REUSE IN THE PROJEQOR SALVAGED FOR LANLORD_ FOR ALL IiEMS DEiERMWED FOR REMOVAL, REFER i0 iHE RECYCLING INSiRUCiIONS. 3. REMOVEEXISTINGRECEPTAQESAND/ORSWITCHESASSHOWN ON PLAN PER LEGEND_ PAiCH WALLAND PREPARE f-0R NEW FlNISHES AS REQUIRED. 4. REMOVEALLEXISiINGWALLCOVERINGiHROUGHOUi EXPANSION SUITE PREPARE WALLS FOR NEW FlNISHESAS REQUIRED. 5. ALL �OORS BEING REMOVE� i0 BE SALVAGE� FOR LAN�LOR�. PLAN NOTES D01 REMOVEE%ISiWGCABWEfRVANDCOIIMERiOP_SALVAGE CABINEiS FOR SCHOIIXCHANGE. D02 REMOVEEXISTINGSINK. NOSERVICESINKSAREBEINGREMOVED. D03 REMOVEE%ISiWGCERAMICiILEFLOORWGAiENiRVAREA_ CARPEi iILE IN RECEPiION ARE i0 REMAIN. D04 REMOVEEXISiINGDRYWALLINORDERiOEXPOSEEXISiING CROSSBRACING AND V ERTICAL CO W MN ON W EST SIDE OF ROOM. CONSULi WIiH S�I IF A��IiIONAL �ESIGN IS REQUIRED PER CODE Ai REDUCED HEAD HEIGHi. 0 �i � � .� o Y J � N b O J � Q o � JJ in Z �. . r n L m J � .� � . P Qn 7 LL O c� J o� s `n O p 3 � 0 2 C iHIS DRA W ING. AND iH E IDEAS. DESIGNS AND CONCEPiS CONiA W ED HEREIN. ARE iHE E%CW $NE IMELLECiUAL PROPERtt OF SCHOii DESIGN. WC..ANDARENOiiO BE useo ore reePreoouceo w wHo�e ore IN PqRi, wIiHOUi iHE wRIIIEN CONSENi OF SCHOII DESIGN. Q � N � � � � � J�vi LJJ �, J W�O � N Q N � � "a � � � W�z ZI� W�� � JQ� � � � w Q � � ISSUE DAiE DESCRIPiION 11.11.19 REVIEWiEi 11.]6.19 PERMIiSEi REVISIONS MAR DAiE DB DESCRIPiION I��. AR10700017 SiATE oF RELEASEU FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ onrE: 01 /13/20 i% ■ AREA NOT IN CONTRAQ AREA OF WORK DECONSTRUCTION PLAN N 0 1' 4' 8' 16' � � � - PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB 1 ST FLOOR DECONSTRUCTION PLAN D111 ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN WALL WALL W? � PARiIAL HEIGHi WALL � PARiIAL HEIGHi WALL �u WINDOW/SIDEIJGHT �¢ WINDOW/SIDELIGHi a� DOORANDFRAME � DOORANDFRAME �SEE DOOR SCHEDl1LEf NOiE: IF IN GOOD CONDIiION, IXISiING DOORS SALVAGED FROM DEMOLIiION CAN BESUBSiIiUiED FOR NEW DOORS- WALL TYPES NOiE: ALL PLAN DIMENSIONS ARE FROM FACEiO FACE OF FINISHED WALL. ALL WALLS ARE TO BE wl UNLE55 OTHERWISE NOTED. PROVIDE MOISiURE RFSISiANi / GREEN BOARD AS REOUIRED IN RESiROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELO W ARE N ECESSARILV USED ON THIS PROJECi. REFER i0 REFLECiED CEILING PLAN FOR CEILING HEIGHiS. W� SiANDARD WALL 35/g" MPAL SiUDS Ai I 6" O.C.; ONE LAVER OF s�" iVPE "k' GVPSUM BOARD EACH SIDE IXiEND WALL i0 UNDERSIDE OF CEILING � W� WALL WIiH INSULAiION 3�g"MEiALSiUDSAi 16"O.C.; ONE LAYER OF 5/" iYPE "k' GYPSUM BOARD EACH SIDE E%iEND WALL i0 UNDERSIDE OF CEILING; FlBERGLASS SOUND BAII INSULAiION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING. PROVIDESEPARAiE PRICE FOR 100% COVERAGE QUIH BARRIER Ai iHIS LOCAiION. w3 PARiIALHEIGHiWALL 35/g" MEfAL SiUDS Ai I 6" O.C.; ONE IAVER OF s�" iVPE "X" GVPSUM BOARD EACH SIDE; SEE ELEVAiION FOR WALL HEIGHi PROVIDE I"SiEEL PIPE ANCHORS INiO CONCREiE FLOOR FOR SUPPORi AS REpUIRED; .._ �_� _—� _— . _ - _ WALL iHICKNE55 � MHAL Sil1D EXIAWG WIN MULLION PRE-FINISHED ALUMINUM RECEIVER iRIM- FASiEN Ai WINDOW SILLAND SET IN A CONiINUOUS BEAD OF CAULKAi WINDOW MULLION WHERENEW WALLSMEEf. iRIM COLOR i0 MAiCH BUILDING wINDOw MULLIONS. PLAN NOTES AQ� ALIGN RNISHED WALLSURFACES. PROVIDESAMETHICKNESS SiUDS AS EXISiWG WALLAi DOOR WFlLLS OR WHERE NEW WALLS ARE IN LIN E wliH EXISiING wALLS. PROVIDE NEW 24" WIDE PLASTIC LAMINATE WALL CABWET A02 ABOVEiOILEi.DOORSiOHAVEMIRRORINSEiSANDSiANDARD BRUSHE9 ALUMINUM GPULLS NEW BRUSHE9 ALUMINUM RRE EXiINGUISHER RECESSED CABW H A03 TOBEPROVIDEDANDWSTALLEDBVCONTRACTOR.ALLFlRE EXiINGUISH ERS ARE i0 BE PROVIDED BY iENANi AND INSiALLED ACCORDING i0 NFPA 10. LINEOFEXISiINGwINDOw A04 NOTUSED. SILLCOVER BELOW PROVIDE ADDIiIONAL BLOCKWG IN WALLAS REQUIRED FOR A05 iENANi'S WALL MOUNiED iELEVISION; COORDINAiE EXAQ LOCATION WITH TENANT. CONTINUOUS BEAD OF ACOUSiICALSEAUNi � WALL AT MULLION DETAIL A I I I NOT TO SCALE AOfi CONRRMTHATEXISTWGWALLMATCHESWALLTVPP'W2'LIFNOT, ALiER EXISiING wALL AS REQUIRED i0 MAiCH'W2". AO] PROVIDE�SflB"DEEPWHITEMELAMWESHELVESASSHOWNON PLAN ON HEAVY DUiY wHIiE K V. BRACKEiS. IN BREAK/SOCIAL HUB I10, PROVIDE WALLTO WALL 60" H. A08 SEGiIONOFiACK-BOARDWALLGOVERWGINSiALLEDFROM30" i090"AFFWALLSURFACEABOVEANDBELOW WALL COVERING TO BE PAIMED. A09 PROVIDESEPARAiEPRICEFORCONSiRUCiIONOFISUND. P�� PROVIDEPOiABLEHOiANDCOLDwAiERANDSANIiARYwASiE AND VENT PIPING FOR SINKS. REFER i0 LANDLORD FOR SOURCE OF HOi WAiER AND LOCAiION ALLOwED IN iHIS BUILDING. P02 PROVIDE WATER LWE FOR �2J COFFEE, WATER COOLER, AND REFRIGERAiOR CONFIRM LOCAiION WIiH iENANL P03 PROVIDEALLNECESSARYPLUMBINGANDDRAINSFORiHJANi PROVIDED DISHWASHER ATTHIS LOCATION. GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAVOUT_ 2 REFERiORNISHPLANFORALLACCENi/SPECIALiVPAINiOR WALLCOVERINGiHAi REQUIRES LEVEL 4 OR LEVELS DRYwALL RNISH. REFER TO MANUFACiURER RECOMMENDAiIONS. �i � .� O Y � � � N b O J � Q o � Jl �nZ� — r ^ y m � �,�� P Qn 7 LL O c+� o O c `� O p ? � � 2 C rHis orenwiNG. nNo m E ioEns. oesi�Ns nNo coNcePrs coNrnweo HereeiN. nreerHe Excwsive IMELLKiUAL PROPERiY OF SCHOii �ESIGN. WC.. AN� ARE NOi i0 BE useo ore reePreoouceo iN wHo�e, ore IN PARi, wIiHOUi iH f wRIIIfN CONSENi OF SCHOII DESIGN. 0 � N � � � � � J� vi 1.1„1 u,, J W�O � � Z Q X � � W�z Z�� W�N � Ja� �� � w 0 � � ISSUE DAiE DESCRIPiION 11.P7.19 REVIEW SEi 11.16.19 PERMIiSEi IREVISIONS MAR DAiE DB DESCRIPiION I��. AR10700017 SiATE oF RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ onrE: 01 /13/20 � nREn Nor w coNrRncr � AREAOFWORK ��%ill �.� l �ifl ��� ARCHITECTURAL PLAN 0 P' 4' 8' 16' � � - �� PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB 1ST FLOOR ARCHITECTURAL FLOOR PLAN Alll LEGEND NEW OR RELOCATED EXISTING TO REMAIN � � FWORESCENi,PARABOLIC � FWORESCENi,PARABOLIC FW%WERX - APERiURE A PENDANi; 6'-0" COORDINAiE WIiH JENNIFER HALL 31]�]50�]221 J HALL@ESLSP ECiR UM. COM PICASSO LIGHiING � iRUSS PENDANi; 6'-0" COOR�INAiE WIiH MELINDA DYKSiRA 31]�5]]�8100 M�VKSiRA@SLSI N � IANA. COM �� E%li LIGHi Fl%iURE qN LIGHiSWIiCH �N3 �IGHiSWIiCH,3-WAY �ND LIGHiSWIiCH,DIMMER i — � LIGHiCIRCUIi TTT CEILINGGRID, ii i SUSPENDED,2k2' � EMERGENCV LIGHi Fl%iURE � E%li LIGHi Fl%iURE � EMERGENCY LIGHi Fl%iURE y LIGHi$WIiCH �3 LIGHiSWIiCH,3-WAY �p LIGHiSWIiCH,DIMMER GENERAL NOTES I. REl1SEE%ISiWGCEIIJNGGRIDANDiILEl1NLESSOiHERWISENOiED. EXISiING GRID IS 2X2 Ai 8'-J" A F F_ iILES ARE 2e2 ACOUSiICAL LAY IN TILES. REPAIRANYDAMAGEDGRIDANDREPLACEANYDAMAGED iILES WIiH NEW i0 MAiCH E%ISiWG. 21FINGOODCONDIiION EXISiINGCEILINGiILESSALVAGEDFROM DECONSTRUCTION CAN BESUBSTITUTED FOR NEW. PROVIDE LIKE CEIIJNG TILES IN INDIVIDUAL ROONS WHERE POSSIBLETO CREATE UNIf-0RM LOOK 3. PROVIDE EMERGENCY LIGHiING IN iENANi SPACE AS REQUIRED PER NEMAANDIBQ EMERGENCVBAiTERVPACKSORLIGHTS CONNEQED i0 AN EMERGENCV POWER SOURCE ARE REQUIRED IF iHE SPACE CONiAINS 50 PERSONS OR MORE. FIXiURES SHOW N ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCEROOMSANDOiHERHIGH PRORLEAREAS WIiHIN SUIiE, ALL LOCAiIONS OF SUCH DEV ICES MUSi BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT TH HR EXPENSE. 4. UNLESS NOiED OiHERW ISE, iHE LIGHiS SHOWN AS'NEW OR RELOCAiED" AREiO BE RELOCAiED FROM A PREVIOUS LOCAiION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LE55 iHAN 50%OF iHE LIGHiS ARE ACiUALLY BEING REPLACED W IiH NEW AND OVERALL WAiTAGE IS STAYING THE SAME OR DECREASING. LAVOUT SHO W N IS INTEN DED TO MEEf ASH RAE 90J STAN DARDS. ELECiRICAL CONiRACiOR IS RESPONSIBLE FOR COMPLIANi INSiALLAiION_ IF ADJUSiMENi IS REQUIRED i0 MEEf ASH RAE 90J, CONTRACTOR MUST NOTIFY SDI. 5. NEW DEVICES AND FACE PLAiES i0 MAiCH E%ISiWG. W HERE POSSIBLE, GANG MULiIPLE SW IiCHES i0 ACCOMMODAiE MULTISW ITCH PLATE WHEN SW ITCHES ARESHOWN ADJACENT ON PLAN. : --\ LIGHi GRCUIi 6- ELECiRICAL W ORK IS LIMIiED i0 A DESIGN-BUILD SCOPE AND IS OUiLINED IN iHESE DRAWINGS- ALL ELECiRICAL WORK IS LIMIiED i0 ADDITIONS OR RELOCATIONS OF ELECTRICAL OURET DEVICES AND LIGHiWG iHAi DO NOi E%CEED iHE CAPACIiV OF iHE E%ISiWG CEILINGGRID, ELECiRICALSERVICEINiHEBUILDING-ELECiRICALCONiRACiORIS SUSPENDED,2k2' �ONOiIFYAPPLICABLEPARiIESIFADDIiIONALWORKISREQUIRED 50 THAT ADDITIONAL PLANS CAN BE RLED AND MUST COMPLV W ITH ALL APPLICABLE CODES. � GYPSUM60ARDCEILING ❑ GYPSUM60ARDCEILING �RELOCAiED DIFFUSER, DIFFUSER, �nr-iN, zxz �nr-iN, zxz o RELOCAiED DIFFUSER, m DIFFUSER, LAV-IN, 4'k4' LAV-IN, 4'k4' NOTE: IF IN GOOD CONDITION, EXISTING H.VA.C. DEVICES AND CEIIJNGTILES SANAGED FROM DEMOLIiION CAN BE SUBSiIiUiED FOR NEW. NO NEW HVAC DUCiWORK ISiO BE INSiALLED PER iHISSHEEi_ MECHANICAL NOTES I. MECHANICALWORKISIJMITE9TOADESIGN-BUILDSCOPEANDIS Ol1iLWED IN iHESE DRAW WGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENi ARE BEING PROVIDED_ ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLE%Dl1Ci PER NEW WALL LAVOl1iJF W GOOD CONDIiION, E%ISiWG H_VA_C_ DIFFUSERS SALVAGED FROM DECONSiRUCiION MAV BE SUBSTITUTED FOR NEW. NO NEW HARD DUQWORK OR EQUIPMENT IS BEINGADDED; MECHANICALCONTRACTORISTONOTIFV APPLICABLE PARiIES IF ADDIiIONAL W ORK IS REQUIRED SO iHAi ADDIiIONAL PLANS CAN BE FILED AND MUSi COMPLY WIiH iHE INDIANA MECHANICAL CODEAND ALL OTHER APPLICABLE CODES. PLAN NOTES R01 CONiROLSOCIAL Hl1B, ALL OPEN AREA, AND HALLWAV LIGHiWG WIiH EXISiING 3-WAY SWIiCH Ai iH1S LOCAiION_ PROVIDE SEPARATE PRICE FOR CEILING IN BREAK/SOCIAL HUB 110 R02 �WHERESHOWNONPLAN�iOBEARMSiRONG-MEfALWORKS- 24X24 MESH EXPANDED MEiAL CEILING IN GUNMEiAL GRAY. CEIIJNG TO BE 12'X8' AND INSTALLED 8" BELOW EXISTING CEILING. E%ISiW G CHIJNG GRID AND iILES ABOV E MEiAL CLOUD i0 REMAIN. REMOVE EXISiING LIGHiING ABOVE CLOUD AS REQUIRED. ATMETAL CEILING CLOUD, PROVIDE 2" AXIOM TRIM IN Gl1NMEfAL GRAV. R03 NOCEILWGWORKREQUIREDAiiHISLOCAiION. 0 �i � � .� o Y J � N b O J � Q O � JJ r�nZ� - r - n L � J � .� � . P Qn 7 w p � � o c ,_ `� O p i � � 2 C iHIS DRA W ING. AND iH E IDEAS. DFIGNS AND CONCEPiS CONiA W ED HereeN. nree rHe Excwsve IMELLECiUAL PROPERtt OF SCHOii DESIGN. W C.. AND ARE NOi i0 BE USED OR REPRODUCED IN W HOLE, OR IN PqRi, wIiHOUi iHf wRIIIfN GONSENi OF SGHOII DESIGN. � � N � � � � � J�vi 1.1„1 u,, J W�O � N � � � z Q X � � W�z Z�� W�� � JQ� a � o� w O � v ISSUE DAiE DESCRIPiION 11.31.19 REVIEW SEi 11.26.19 PERMIiSEi REVISIONS MAR DAiE DB DESCRIPiION RELOCAiE DIFFUSERS 8 nMECHANICAL DIFFUSER RELOCATION RELEASEDFORCONSTRACTION `REFERro^^E�H^N��^�NorEs�RF�RrHER�N�R^^^r�oN Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ onrE: 01 /13/20 � AREA NOT IN CONTRAQ � AREA OF WORK REFLECTED CEILING PLAN 0 3' 4' 8' 16' � � - �� I��. AR10700017 SiATE oF PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB 1ST FLOOR REFLECTED CEILING PLAN A121 LEGEND FINISHES SHALL MEEi ALL CLASS A FIRE RAiINGS AND COMPLY WIiH CHAPiER 8 OF INiERNAiIONAL BUILDING CODE. FLOOR COVERINGS EX EXISiWGFLOORWGiOREMAIN CARPEi NOTE SHAW MANUFACTURER PARTICIPATES IN SCHOTf DESIGN'S RECYQING NO COSiADD i0 CUENi OR PROJECi PROCESS. REFER iOSCHOii DESIGN DECONSiRUQION NOTES ON TI I I AND DI I I FOR PROCESS DETAILS. ��� MFG: SHAW CONiRAQ TVPE: MODULARTILE PAiiERN: SHINE59328 COLOR: GLEAM D585 NOTE: MATCH E%ISTWG WSTALL MEfHOD �PTz MFG: SHAW CONiRAQ TVPE: BROADLOOM PATTERM FLARE 5A V5 COLOR_ GLOSS 2]]61 CPT3 MFG: iBD (SEPARAiE PRICE FOR NEW OFFICES) iYPE: $19/YDMODULARiILE PAiiERN: — COLOR: — VINYL COMPOSIiION iILE VCTt MFG: ARNSTRONG sze izxir PAiiERN: SiANDARDEXCELON co�oa: - WXURV VINVLTILE NOTE: AT ALL LVT LOCATIONS, PROVIDESKIMCOAT OF ARDE% LEVELWG LAiE%AS NEEDED FOR SMOOiH SUBFLOOR iHAi wILL NOi ALLOw FOR iELEGRAPHING OF IMPERFEQIONS IN iH E ROOR ��� MFG: SHAW CONTRACT SIZE_ 6"X48" PAiiERN: SOLIiUDE0648v COLOR: WOODLAND48I60 WALL BASE E% EXbiING WALL BASEiO REMAIN MFG: MANNINGiON VBl 7YPE: 4" OPiIMUM EDGE, Y" GAUGE COLOR_ SVNC913MWERALGRAV PAINT / WALLCOVERING E% E%ISTING WALL RNISH TO REMAIN Pi1 MFG: SHERWIN WILLIAMS TVPE: LATE% COLOR_ SW ]051 ANALYiICALGRAY RNISH: EGGSHRL PT2 MFG: SHERWIN WILLIAMS TVPE: LATEX COLOR: SWI053ADAPTNESHADE FINISH: EGGSHELL PT3 MFG: SHERWIN WILLIAMS iYPE: LAiEX COLOR: SW6684BRITfLEBWSH RNISH: EGGSHELL pT4 MFG: SHERWIN WILLIAMS PRIMER: PRO-CRVL iOPCOAi: PROINDUSiRIALRECAiALYZEDwAiERBASED EPDXY K46W I51 COLOR: SW6684BRITfLEBWSH FINISH: SEMbGLOSS INSiALL: PREPANDINSiALLPERMANUFACiURER'S RECOMMENDATIONS FOR MAXIMUM ADHESION. THIS WC W DES CLEANWG AND SCUFF SANDWG PRIOR i0 APPLYING NEw FINISH. APPLY USINGSPRAY APPLICAiION. PT5 MFG[ SHERWIN WILLIAMS PRIMER: PREPRIiE PROBLACK LAiEX PRIMER, B51 SERIES TOPCOAT: PROINDUSTRIALACRVLIC B66-650SERIES COLOR' - FINISH: SEMI-GLOSS INSTALL: PREPANDINSTALLPERMANUFACTURER'S RECOMMENDATIONS FOR MA%IMl1M ADHESION. iHIS INCLUDES CLEANWG AND SCUFF SANDWG PRIOR i0 APPLYING NEW FlNISH. APPLY USING SPRAY APPLICATION. W�� MFG: SiUDIOSOURCE PAiiERN: - COLOR: MBI013 WC2 MFG:iBD�$20/YARDMAiERIALALLOWANCE) PAiiERN: - COLOR: - PLASTIC LAMINATE / SOLID SURFACE EX E%ISTINGTOREMAIN p�� MFG- FORMICA �CABWHS) COLOR: BLACK-PLEXFINISH909-PX on MF�: coRinN IcouNrERroP� COLOR: CALACATfA NATURA RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ GENERAL NOTES I. REFERTOLEGENDFORALLACCENT/SPECIALTVPAINTOR WALLCOVERWG iHAi REQUIRES LEVEL 4 OR LEVEL 5 DRYwALL FlNISH. REFER i0 MANUFAQURER RECOMMENDAiIONS. 2 CONTRACTORTOEVAWATEE%ISTINGFLOORINGCONDITIONS AFiER DEMOLIiION IS COMPLEiE AND PREP AS NECESSARY PER MANUFACiURERSRECOMMENDAiIONS. SEALCOAiiHE CONCREfE FLOOR PRIOR TO LAVING ADHESNE IF DEEMED NECESSARV. 3. AiALLFLOORiILELOCAiIONSPROVIDEwAiERPROOFINGCRACK ISOLATION MEMBRANE: TEC HVDRAFLE%Fl1LL COVERAGE PER iCNA FI2SI I FULL PROVIDE CONiROUOIMS EVERY 12 Ai MINIMUM OR AS RECOMMENDED BY MANUFACiURER. 4. AiNEWWALLiILELOCAiIONSPROVIDEAPPROPRIAiESU&SiRAiEFOR WALL➢LE �Ai EXISiING WALL$$CHLUiER KERDI BOARD OR EQUAL� �Ai NEW WALLS CEMENi BACKER BOARD�AS RECOMMENDED BY MANOFACipRER. 5. PROVIDESEPARAiEPRICEiOPAINiALLNEWANDEXISiINGDOORS QN EXPANSION SOIiE AND EXISiING SOIiE�. OSE SHER WIN WILLIAMS PRO-CRYL PRIMER WIiH PRO INDUSiRIAL PRECAiALYZED WAiER BASED EPDXY K46W I51 iOP COAi IN SEM6GLOSS. PREP EXSIiING DOORS AS REQOIRED i0 RECENE PAINi i0 ACMEVE SMOOiH FlNISH. � lO� PT2 �I� CPT2 CPT2 VB1 PT1 V81 pT� PPV�PY 0 6. PROVIDESEPARAiEPRICEiOREPAINi�3�WOOD-iRIMMEDDOOR FRAMES OFF RECEPiION AND CONFERENCE I 16 WOOD CPTt DOOR/WINDOW FRAMES PLAN NOTES � VB, Wc, F01 PROVIDEJOHNSONITESLIMLWESLT-%%-FPROFlLETRANSITIONSTRIP Ai FLOORING iRANSIiION; COLOR: iBD. CONiRACiOR MUSi PROVIDE LEVELING LAiEX SUCH iHAi HEIGHiS OF MAiERIALS ARE APPROPRIATE FOR USE WITH SPECIRED PRORLETRANSITION. BE AW ARE iRANSIiION SiRIP MUSi BE ORDERED IN A iIMELY MANN ER AS li IS NOi ALWAYS IMMEDIAiELY AVAILABLE. DESIGN INTENT IS FOR TRANSITION FROM CARPET TO LVT TO BE �z SMOOTHWIiHNOTRANSITIONARIPSINCEHHGHTOFCARPHPILE IS SAME HEIGHi AS Lvi iHICKNESS. IF NOi POSSIBLE, COORDINAiE WITH SDI. F03 REPUCECUiTILESFORCOMINUOUSLOOK F04 EXISiING CROSS BRAQNG i0 REMAIN AND BE PAINiED �Pi4�. SEAM SEAL TRANSITION BEf W EEN EXISTING CARPET AN D NEW F05 CARPELSLIGHiDYELOiDIFFERENCEWILLOCCURBEiWEEN EXISiING AND N Ew CARPEi. �6 PROVIDESCHWTERSCHIENETRANSITIONSTRIPATCARPETTOTILE iRANSIiION, FlNISH_ BRUSHED AAWLESS AEEL �EB�_ PROVIDE LEVRING LAiEX UNDER CARPH AS SUCH iHAi iOP OF RNISHES ARELEVEL SEAMSEALCARPETEDGES. TRANSITIONSTRIPMl1STBE LEVEL WIiH OR SIJGHiLV HIGHER iHAN iILE EDGE iRANSIiION PROFILE MUSi BE APPROPRIAiE FOR FLOORING MAiERIALS AND MUST BESUBMITTED TO SDI FOR RNAL APPROVAL PRIOR TO WAALLAiION_ FW NOFlNISHWORKREQUIREDAiiHbLOCAiION. F08 TOl1CHl1PRNISHESASREQl11REDTOLIKENEWCONDITIONPER DECONSiRUCiION OF CASEWORK. F08 PROVIDE SEPARAiE PRICE FOR CONSiRUCiION OF ISLAND. F09 REATfACH ANV EXISTING VINVLBASHN THIS LOCATION. OREPAINi WOOD DOOR AND FRAME IN iHIS LOCAiION (Pi5). F�� COORDINAiEWIiHiENANiFORCOLORSELECiION. F0� . ■ nREn Nor w coNrRncr AREA OF WORK LVrt VBt WC2 sr��A�E c�cs-i 0 IIIICI 0 CPT2 VB1 PT1 F22AK/:_Clh HA 0 LVrt VB1 C2 , :'Ill:'I l O CPT2 VB1 PT1 CPT1 VBt WCt ��JVFEREPCE 0 0 � � .� o Y J � N b O J � Q o � JJ ✓�iZ� — r — n y m � � .� � . P Qn 7 LL O c� J o� s `n O p 3 � � 2 c iHl$ DRA W ING. AND iH E IDEAS. DESIGNS AND CONCEPiS CONiA W ED HereeN. nreerHe Excwsive IMELLKiUAL PROPERiY OF $CHOii � � DFIGN. WC..ANDARENOiiO BE � USED OR REPRODUCED IN W HOLE OR �p7p IN PARi, W IiHOUi iH f W RIIIfN CONSENi OF SCHOII DESIGN. E CPT2O VB1 EX �� Q � N � � � � � � r � I.IJ �, J W�O � � Z � � � W�z ZI� W�� � JQ? � � � �.�..� Q � � ISSUE DAiE DESCRIPiION 11.11.19 REVIEW SEi 11.]6.19 PERMIiSEi REVISIONS MAR DAiE DB DESCRIPiION I��. AR10700017 SiATE oF PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB 1ST FLOOR FINISH PLAN A131 onrE: 01 /13/20 FINISH PLAN 0 1' 4' 8' 16' � � — iza ELEVATION - BREAK/SOCIAL HUB 110 ISLAND `ISLAND UNIi i0 BESEPARAiELV PRICED 0 I' 3' 4' � DOOR SCHEDULE # DIMENSIONS DOOR TYPE MATERIAL FINISH O� 3,�„x8,�„x�3�q, D2 SOLIDCORE STAINTC BIRCH VNR. MATCH EX 08 3�_��k8�_��kla/a' D2 souocoee srniNrc BIRCH VNR. MATCH EX 09 3�_��k8�_��kla/a' D2 souocoee sTniNTc BIRCH VNR. MATCH EX 19 3'_0"x8'_0"x13/q' Dl souocoee srniNrc BIRCH VNR. MATCH EX 20 3'_0"x8'_0"x13/q'(PAIR) p� souocoee siniNic BIRCH VNR. MATCH EX SOLID CORE STAIN TC 23 l6DOORSI �� siRch'vNR. nnqich'Ex DOOR/FRAME TYPES I I 0 U O 0 O D1 � D2 RUSry BEnD sr�nwco ro Mnrr.H o�re FRAME TYPE MATERIAL FINISH Fl TIMELY MATCH EXIST. Fl TIMELY MATCH EXIST. Fl TIMELY MATCH EXIST. Fl TIMELY MATCH EXIST. F2 TIMELY MATCH EXIST. DRYWALL WRAPPED OPENING 34• 3'-0" f 0 U O 0 O Fl REMARKS HARDWARE REM. RI.PROVIDEDOUBLESLIDINGDOORiRACKSYSiEMWIiHDOUBLE RAIL IMENi IS FOR EVERV OiHER DOORS i0 BE ON SEPARAiE iRACKS PROVIDE RECESSED FINGER PULLON CENiER OF EACH DOOR. PS PS PS SL RL,DL d d• q. 6,_p. F2 HARDWARE LEGEND CL CLOSER CH COAiHOOK CR CARD READERBViENANi�NJ.C.) DB DEADBOLi DL DUMMY LEVER Rl E� E��rRomncNEric�ocK�Peaiaczmz� ES ELECiRICSiRIKEBYiENANi�N.LC.� H HOLDOPEN KP KICK PLAiE KS KICKSiOP OL OFRCELOCKSH PH PANIC HARDWARE PL PRNACY LOCKSEi PP PUSH/PULL PS PASSAGELAiCHSEi PV PNOiHWGE RL ROLLER LAiCHES SL SiOREROOM LOCKSEf iS iOPSiRIKES DOOR/FRAME NOTES I. REl1SE DOORS FROM DECONSiRlICiION WHERE POSSIBLE iOl1CH 11P EXISiING DOOR SiAIN AS REQUIRED. PROVIDE NEW BUILDING SiANDARD DOORS MAiCHING EXISiING VENEER AS REQUIRED. SiAIN NEW DOORS i0 MAiCH E%ISiING. PRE-MACHWE NEW DOORS FOR CVLINDRICAL LOCKSEiS. 2 PROVIDE NEW HARDWARE i0 MAiCH EXISiING ON NEW DOORS. REUSE EXISiING HARDwARE ON EXISiING DOORS wHERE POSSIBLE. FOR NEw DOOR HARDWARE PROVIDE GRADE 2 MINIMUM BUILDING SiANDARD. PROVIDE A D A_ ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LAiCHSEiS. 3. PROVIDENEW BUILDINGSiANDARDFRAMESASREQUIRED. REUSEEXISiING FROM DEMOLIiION WHERE POSSIBLEJF FRAMES ARE NOi BEING REPAIMED, iOUCH UP EXISiING FRAMES i0 BE REUSED. 4 FRAMEALL DOOR ROUGH OPHJINGS 4" FROMADJACENi WALL CORNERS 11NLESS OiHERW ISE NOiED ON PLAN. 5. REFERiOiENANiANDLANDLORDFORKEYINGREQUIREMENiSAND LOCKSEA. 6. iENANiS SECURIiV VENDOR IS RESPONSIBLE FOR iHE SPECIFlCAiION, PURCHASE AND INSiALLAiION OF ALL ACCESS CONiROLLED ELEQRON IC AND/OR MAGNEiIC HARDwARE AND ASSOCIAiED DEVICES. ALL SPECIFlCAiIONS AND INSiALLAiIONS MUSi COMPLV W IiH iHE INDIANA Bl11LDING CODE CHAPiER IQ MEANS OF EGRESS. J. PROVIDEBUiiHINGESONALLDOORSASFOLLOWS: • ]'-0"Hi.iOHAVE3HINGES • GREAiER iHAN ]'-0" IN Hi. i0 HAVE 4 HINGES • FINISHiOMAiCHHARDWARESEi 8. PROVIDE�I�SEiOFSILENCERSONALLDOORFRAMESUNLESSOiHERWISE NOiED. 9. PROVIDE WALL SiOP �ROOR SiOP W HEREAPPLICABLE) Ai EACH DOOR 11NLESS OiHERW ISE NOiED. PROVIDE W OOD BLOCKING BEHIND WALL SiOP. � .� o Y J � N b O J ��o� o� N Z � ' L n L ro o � .� � . P Qn 7 � o m � o c � o a s � � 5 C iHIS �RA W ING. AN� iH E I�EAS. �ESIGNS AN� CONCEPiS CONiA W E� HEREIN. ARE iHE E%CWSNE INiELLKiUAL PkOPEkiY OF SCHOv �ESIGN. WC..AN�AkENOiiOBE useo ore reePreoouceo w wHo�e ore iN aqer, wimour mE wemEN CONSENi OF SCHOii DESIGN. Q � N`^ V � �1^ � _/ J�vi LJJ �, J W�O t/i �,;� Z `Y ' Q I \ � � WOz Z�� W�� � JQ� � � � w Q � � ISSUE DAiE DESCRIPiION 11.31.19 REVIEW SEi 11.26.19 PERMIiSEi REVISIONS MAR DAiE DB DESCRIPiION I��. AR10700017 SiATE oF PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB 1ST FLOOR DOOR SCHEDULE/ INTERIOR DETAILS � _ .o E�=.��� SiACK IfY I Ir � I I �� I I \ JI i� v. III I II �:zVx rvorE�.reEFEreroF�ooRv�Ary uao cnsewore. e�evnnows fOH$INKLOGnOVS a�W- —~BWNirvG DRary � RISER DIAGRAM A211 iVPICALALLSINGLELOCAiIONSNOiiOSCALE ($EE 24'DEEPQpARiZ�QZ1�COI1MERiOP �. WIIH BACKSVLASH. PROVI�ESEPAAAIE = PAICE FOH SOLI� SUHFACE W LIEU OF CONFlRM FlNqLSIZE OF MICRO WAVE W i1H IENAM VRiOR 10 FABRiCA➢ON PIq91C IAMINqIE (PLI � BISE CABWP$ ($EECASEWORK uorE ii 3'J' , 3�" , 3'3" , 3�" 3-3' aerw� er r�nNr MICROWAVE MICROWAVE qpq . BOX BOX ��,H� oisnwnsnea — — BY iENAM i. y' I 'i' S" I 'i' S" I 'i' d' I 3' d' 2' 3' I 1' a' ELEVATION - B °'�I IIIIIIIL — JIIIIIII CASEWORK NOTES GENERAL NOiE: CONiRACiOR i0 CONFIRM iHAiSINKS NOiED IN ELEVAiIONS PROPERLV COORDINAiE WIiH WIDiH AND DEPiH OF BASE CABW Ei PRIOR i0 ORDERING. L PROVIDEA W LNSiOM GRADE, FLUSH-OVERLAY CABINEiS FABRICAiE WIiH PLPSiIC LAMINAiE �AS NOiED W REVAiIONS) COVERED M.D O. BOARD WIiH CKP BRAND PREMIUM SERIERS SiAINLESS BAR PULL #8000-128MM. COORDINAiE wliH ELEVAiIONS FOR Ql1ANiliIES. -Ai BREAK/SOCIAL HUB I 10 PROVIDE_ 24" DEEP COUNiERiOPS 23" DEEP BASE CABW EiS I I��" DEEP �INiERIOR CLEAR DIMENSION) UPPER CABINEiS - J" BASE Ai CABWEiS i0 BE VINVL BASE AS SPECIFlED, UNLESS NOiED OiHERWISE. SINCLE BO WL IIN�ER-MOIIM SINK�. 10 GAUGE S1A W LE55 S1EEL ELKAY 234k1�'K5-`/a' kELI1HAD21IS55 �OR EQIIAL� WIIH KOHLER SImPLICF FAUCFT MKS9J-%% �OR EQOAL� AN� GARBAGE �bPOSAL �No�o� OCIAL HUB 110 0 1' P' 4' � vaovioe a-o� x iz-o� ouna�z�ozi � isnNo nr arz� n F v. wirH mirea vom EDGEDPAILqiCORNERSUCHiHAi HORiZON1AL QOARRPAl1ERN IRANSIIIONS IO VERIICAL�IRECIION nNo �ieNoS �o aooa. 6�nNo CEMERED ON WqLL BELO W. PROVIDE CONCEALED/ IN-WqLLSI1PPORTSAS REQIIIR E�. PHOVI�E SEPAAAIE PAICE FOH vnann� ne�cni wnu BELO W. W /LLLCOV ERING BASEA$ RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ onrE: 01 /13/20 A211 LEGEND NEW CONSTRUCTION � POWER OURET,DUPLEX Jk POWEROUiLEi, �� QUADRUPLEX � JUNCiION BOX �: CEILINGMOUMED JUNCiION BO% '�j BOR BLANK COVER PLATE V BOX,OPEN P PROVIDEJUNCiION BO% U ABOVECEILINGFOR POWER POLE CONNECiION. POWER POLE BY OiHERS. FLOOR BOX WIiH POWER �b AND DATA, FLUSH MOUMED FLOOR BOX WIiH ;J�IQ JUNCTION BOXAND DAiA, FLUSH MOUMED DAiA/COMMUNICAiION q OUiLEi �PROVIDE BOX AND PULLSiRWG ONLVJ DED DEDICAiEDCIRCUIi GFCI GROUND FAULi QRCUIi INTERRUPT OUREf +42" HHGHTOFELECTRICAL OR DAiA DEVICE USB RECEPiAQEiOBE QUAD WITH 2 USB PORTS E%ISTING TO REMAIN � POWER OURET,DUPLEX � POWEROUiLEi, QUADRUPLEX �J JUNCiION BOX O CEILINGMOUMED JUNCiION BO% QB BOX, BLANK COVER PLATE �o BOX,OPEN � POWERANDDAiAPOLE FLOOR BOX WIiH POWER �b ANDDATA,FLUSH MOUMED FLOOR BOX WIiH QJ IC� JUNCTIONBOXAND DAiA, FLUSH MOUMED a DAiA/COMMUNICAiION OUTLET GENERAL NOTES I. iENANi'S FURNIiURE VENDOR IS RESPONSIBLE FOR INSiALLAiION OF FURNIiURE AND FIELD V ERIFICAiION OF ALL CRIiICAL DIMENSIONS. 2. ALLOURETSARETOINSTALLEDIS"MIN.A.FFTOTHECENTEROF iHE DEVICE PERADA GUIDELWES UNLESS NOiED OiHERWISE ALL NEW DEVICES AND FACE PLAiES i0 MAiCH EXISiWG. 3. R EFER TO DOOR SCHEDULE AND COORDINATE W ITH iENANi/OW NER REGARDING POWER LOCAiIONS i0 ACCOMMODAiEELECiRIC SiRIKES. CARD READERS AND/OR MAG-LOCKS. CARDREADERSAREiYPICALLYINSiALLEDBYiHE TENANTS SECURIiV CONTRACTOR AND NOT SPECIRE9 BV SDI. 4 ELECiRICAL W ORK IS LIMIiED i0 A DESIGN-BUILD SCOPE AND IS OUiLWED IN iHESE DRAwINGS. ALL ELEQRICAL wORK IS LIMRED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OURET DEVICES AND LIGHiING iHAi DO NOi E%CEED iHE CAPACIiV OF iH E EXISiWGELECiRICALSERVICEINiHEBUILDWG. ELECiRICAL CONiRACiOR IS i0 NOiIFY APPLICABLE PARiIES IF ADDIiIONAL W ORK IS REQUIRED SO iHAi ADDIiIONAL PLANS CAN BE FlLED AND MUSi COMPLV W IiH ALL APPLICABLE CODES. 0 �i � � .� O Y J � N b O J � y O � JJ ti Z � — r — n L m J � .� � . P Qn 7 LL o m � O c ,_ _ `� O p i � 0 3 C rH�s orenwiNG. nNo m e ioens. f]61GNS AND CONCEPiS CONiA W ED HereeN.nreerHeExc�usive IMELLECiUAL PROPERtt OFSCHOii �ESIGN. W C.. AND ARE NOi i0 BE USE� OR REPRODUCED IN W HOLE OR IN PARi, W IiHOUi iHE W RIIIfN GONSENi OF SGHOII DESIGN. Q � N � � � � � J� vi 1.1„1 u,, J W�O � N Q �/i � Z Q � � � W�z Z�� W�N � Ja� �� � w 0 � � ISSUE DAiE DESCRIPiION 11.11.19 REVIEW SEi 11.]6.19 PERMIiSEi REVISIONS MAR DAiE DB DESCRIPiION I��. AR10700017 SiATE oF PROJECT NUMBER 2017.403 PROJ. MGR DRAWN BY SDH/MS CRB RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y\0.v��i �\p;,V'iiY?A�i \ onrE: 01 /13/20 � nREn Nor iN coNrRncr � AREA OF WORK PLAN NOTES E01 COORDINAiECOPIERRECEPiACLEWIiHiENANi. PROVIDE DEDICAiED RECEPiACLEAS REQUIRED. OPROVIDE DEDICATED POWER OURET IN RECESSED BOX INSET E02 INiO CABWEi/ WALL FOR iENANiS MICROWAVE CEMERED Ai 24" A F.F. E03 PROVIDE POWER AND DATA FOR TENANTS WALL MOUNTED iELEVISION Ai HEIGHi NOiED ON PLAN. COORDINAiE E%ACi LOCAiION WIiH iENANi. E04 PROVIDEPOWERAiiHISLOCAiIONFORiENANi'SDISHWASHER AND GARBAGE DISPOSAL. E05 NOELECiRICALWORKREQUIREDAiiHISLOCAiION. ELECTRICAL PLAN 0 1' 4' 8' 16' � � - �� 1ST FLOOR ELECTRICAL PLAN E111