Loading...
HomeMy WebLinkAboutA102 - Architectural Power Plani i SEPHORA ♦ ,� 3-„ 3�4 �, F. I� > EXISTINGEGRESS II � � ,� COFFIDOF(N.I.CJ �'�-�_ � P� r__ J ,. w a 0 � M e � X �- ADJACENT TENANTSPACE (N.I.C) O O I _u i I I � I i i � i L L J J � LI� _ _ JJ .. �__ I `� L__J _ ____ k— �I � I . �� .t �r` .z�.er .cll� II z�.er �.sc ����� z�x.ee= - � ����� _ I' Yi ,9 — + A-SOfi n A-506 I' i �0'-0 �IB"V.I.F. � � �---�- i ! �: - .. .. _ —_—_—_— a � `� �j— _ i—��—_ —�=(y._— — � �--- -� - _� � � I . 1—_—� � _ �—F �_�— ,�� . , , . . , , ,� . . , , . � a.. ���� z ♦. � �. � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � ADJACENTTENANTSPACE(N.I.C) �0'-0"V.I.F. 104'8 112" LEASE LINE TO LEASE LWE, V.I.F. �F15ff6YI��AAY ��_ . ♦ % > > FRONT E%TERIOR OF BUILDING � : 525 MARKET STREET, 32ND FLOOR SAN FRANCISCO, CA 94105 I . � • � � • STAMP / � Q �ATE ISSUEDESCRIPTION BV CHECK 10.0I.19 �ESIGN�EVELOPMENT AE DM flA6.19 ISSUEFORPERMIT AE DM �a POWER PLAN ALP. _�-0. NOTIFVARCHITECTIMME�IATELVOFANVINCONSISTENQESOR�ISCREPANCIESWITHPLANSINRELATIONIDEXISTING � pOWERFL00R0UTLETATCOLORGONDOLA-REFERTOELECTRICALDRAWWGS. FIELD CONDITIONS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE ON THE CONSTRUCTION DOCUMENTS. DO NOT SCALE. �IMENSIONSAREFROMTHEFACEOFFINISHE�WALLTOFACEOFFINISHE�WALLUNLESSOTHERWISENOTE�ONPlANS. � POWERFORHAIRTOOLSFIXTURE-REFERTOELECTRICAL�RAWINGS. ALL MANUFACTURED ARTIQES, MATERIALS 8 E�UIPMENT SHALL BE APPLIED, INSTALLED, CONNECTEq ERECTED, USED. CLEANE�,BCON�ITIONE�INACCOR�ANCEWITHTHEMANUFACTURER'SWRITTENSPECIFICATIONSORINSTRUCTIONS. 3 NOTUSE�. ALL WORK SH4LL BE E%ECUTED IN A MANNER ACCEPTABLE TO THE OWNER. � UNLESSNOTEDOTHERWISE,THEGENERALCONTRACTORSHALLPROVIDEANDPAVALLLABOR,MATERIALSEQUIPMENT, q NONSED. TOOLS.CONSTRUCTIONEDUIPMENT.MACHWERV.TRANSPORTATION.PERMITSANDOTHERSERVICESANDFACILITIES � NECESSARV FOR PROPER AND TIMELV EXECUTION OF WORK. THETENANTSCONTRACTORWARRANTSTOTHEOWNERAN�TOTHEARCHITECTTH4TALLMATERIALSAN�EpUIPMENT 5 POWERPORGRAPHICLIGHTBO%-REPERTOCOLUMN-0ETAILS. FURNISHED UNDER THE CONTRACT ARE NEW UNLESS OTHERWISE SPECIFIED AND THATALL WORKS WILL BE AS SPEQFIE�AN�FREEOF�EFECTS. fi ELECTRICALOUTLETSHALLBEINSTALLE�ABOVEBACKWRAP-REFERTOELECTRICAL�RAWINGS. FOR ALL WOOD MEMBERS RE�UIRED BV CODE TO BE RRE RETARDANTTREATED, PROVIDE PRESSURE IMPREGNATION � WITHFIRERETAR�ANTCHEMICALSTOPROVI�EULCPRSFIREHAZAR�CLASSIFICATION,ALLWOO�SHALLBEI�ENTIFlE� � pOWERFORGRAPHICLIGHTBO%ATCASHWRAP-REFERTOELEVATIONSAN�ELECTRICAL�RAWINGS. W ITH A ULC LABEL CERTIFVING THIS CLASSIFICATION. APPROVED FIRE E%TINGUISHERS SHALL BE INSTALLED AS REQUIRED BV LOCAL AUTHORIiV. ALLPENETRATIONSOFFIRERESISTNEFLOORORSHAFTWALLSSHALLBEPROTECTE�BYMATERIALSAN�INSTALLATION 8 POWERFORBEAUTVSTUDIO-REFERTOSHEETAbO6ANDELECTRICALDRAWINGS. DETAILSTHATCONFORMSTOULSTANDARDSFORTHROUGHPENETRATIONRRESTOPSVSTEMS THECONTRACTOR SHALLSUBMITSHOP�RAWING�ETAILSWHICHSHOWCOMPLETECONFORMANCETOTHEULLISTINGTOTHEARCHITECT. g NOTUSED. SUCHDRAWINGSSHALLBEAVAILABLETOANVCITVINSPECTORS. THEDRAWINGSSH4LLBESPECIFICFOREACH � PENETRATION WITH ALL VARIABLES DEFINED. ALLOUTSIDECORNERSATDRVWALLPARTITION58FURRWGTOHAVEMETALCORNERBEADSSPACKLEDANDSMOOTH. 10 PINPADLOCATION-REFERTOELECTRICALDRAWINGS. THE CONTRACTOR IS TO REPLACE ANV RREPROORNG REMOVED OR DAMAGED FROM THE BUILDING STRUCTURE DURING �EMOLITIONICONSTRUCTION. �� POWERAN��ATAINSTALLE�WITHINBACKWRAPMILLWORK-REFERTOELEVATIONSAN�ELECTRICAL ALLGIASS,INTERIORANDE%TERIORANDALLSTOREFRONTMETALTOBECLEANEDWITHALIQUIDDETERGENTAT .DRAWWGS. COMPLETION OF CONSTRUCTION. CENTER LWE OF MANAGER'S DESK. REFER TO DETAIL t]IA506 AND ELECTRICAL DRAWINGS FOR MOUNTWG PROVIDEDIAGONALBRACINGTOSTRUCTUREABOVEALLDOORS.GLAZWGHEADSANDJAMBSASRE�UIREDTOMAKE �� LOCATIONSOFELECTRICALB�ATAOUTLETS. ASSEMBLV RIGI�. CONTRACTORISRESPONSIBLEFORMAWTAININGINTEGRITVOFRATE�PARTITIONS&STRUCTUREPARTICULARLV 13 APPRO%IMATESTUB-UPLOCATIONFORCASHWRAP.REFERTOAb06. WHERE PENETRATED BV VARIOUS TRADES AND SERVICES. THEGENERALCONTRACTORTOPROVI�EAN�INSTALLPAPERCOVERINGAPPLIE�TOTHEINSI�EOFTHESTOREFRONT �4 POWERFEEDERLOCATION.REFERTOELECTRICALDRAWWGS. GNZWG DURWG MERCHANDISWG. IF RE�UIRED. � THEGENERALCONTRACTORISRESPONSIBLEFORTHEFINALCLEANUPOFTHEENTIREPREMISESTOINCLU�EBUTNOT �CENTERLWEOFRECEIVING�ESK.REFERTO�ETAIL191A-SOfiAN�ELECTRICAL�RAWINGSFORPOWER,�ATA LIMITED TO FLOORS, MILLWORK, FIXTURES, ETQ 15 . AND THERMOSTAT MOUNTING LOCATIONS. "" """' """""'""'""" """""""""""""EWOODBLOCKINGTOSUPPORTALLOWNERSUPPLIEDANDMWC RELEA$EDFORCONSTRACTION NSTAUATiononwn��s.co�uMns.erc ccsnnucooRoinnre +s Noruseo '�VOFBLOCKINGRE�UIREMENTANDPROVIDEALLSUCHBLOCKING — Su6jec��ocompliancewithallregula�ions >.ETC.IFREpUIRE�BVCO�EAN�LOCALBUIL�INGOFFICIAL,SUCH �� NOTUSED ofSla�eantlLocalCodes EETSUCHREpUIREMENL � City of Carmel ��,«,����„��a! s A3E� KEY NOTES �, N,s onrE: 01 /16/20 � � � v N 94-,o•��F ADJACENTTENANT PACE(N.I.CJ . 3]'-31I4" T-10" _ —_— � � .— _ _ _. o --- o o c ._ _ _ _ — — o — — _ _ _ _ _ Zl o 0 0 —._ — _ _ — _ "' _ — — — _ _ _ F _ '�' _ ;�` _ o — o o — _ _ _ _ �- _ — _ _ _ _ o �.�= o o i. _ _ _ o -)_ o __ J i 1'9" � 18'-2'. � �i � 8] 112' � 9 9 9 a'. � 9-0'. � 19'A 11a'. -, - -,� , - _ . --- �-�------ .- — ❑ — — �'��� �{ - 2-�` o '�=� ��� �-�-� � I � i I �— , , . _ � ]'Q 0l4" � ]'Q 0l4" � ]'Q 0l4" � fi'-fi 1@" 1'A 1/2" ]'-2014" � x \ 6-z„z•��F ' I� A�JACENT TENANT SPACE (N.I.0 ) � . . '� . . . � �I � � �--- i-` �— I __mr � � i —�r— —� —rr � i ''s" � oi u i� iui I u i� iui � i� � iui � i � iui , _� � i � - �im�ul, u i� ��a�oS u i� �om�o� u � ^,n�<< i i�om�l� .i, I I i .� I m i m i I i uu I i uu I i uu uu � � : . ia m — '-*.�------I�— �-a�+�+----- �I�--�Ffr------ —I��3-------���I'------ -�i-�.���.;.-�, i�----- i � I n --— I I I I II I � I II I � I II I I I II I I p � I � 21 I _ - - , _ �_ —��_ — — - y _�µ il — � . - . n � - , .Mfli I �,Ml.li I . �.I'. i / LJ " I ._ ,. � , — I � �� ��_ � i I' I' � � � �.�—_� 18 NOTUSED � 19 � POWER OUTLET INSTALLE� ON WALL. REFER TO ELEVATIONS FOR MOUNTING HEIGHT. OUTLET AN� COVER PLATE . SHALL BE BIACK. 20 EASCONTROL-REFERTOELECTRICAL�RAWINGS. 21 VOLUME CONTROL TO BE LOCATED IN THE BACKWRAP -REFER ID ELECTRICAL DRAWINGS. � 22 � IN SL4B EAS SVSTEM EXTEN� LOW VOLTAGE WIRE FROM SVSTEM IN SL4B TO FLOOR BOXANTENNA. MAX . DISTANCE FROM SLAB SVSTEM TO FLOOR BO%ANTENNA IS 20'-0". � FLOOR BO%ANTENNA (12 i"L% 6"T % 1'p' DJ AND AM CONTRO W NIT (21b'W %6S" D%9.8" �- LOCATE IN WALL �3 CAVITV.(LOCATEABOVECEIIJNGIF20'-0"MA%DISTANCEFROMSIABSVSTEMALLOWSJ.LOCATEINWALLTO � �ALLOWACCESSPANELTOBEINSTALLEDASSHOWNINELEVATION. SYMBOL DESCRIPTION - FLUSH FLOOR MOUNTED GROUNDED DUPLEX RECEPTA0.E WI COVER. SEE ELECTRICAL — DRAWINGS. �II�� WMLLRECEPTACLE.SEEELECTRICAL�RAWINGSFORMOUNTINGHEIGHT. QUA� WALL RECEPTACLE. SEE ELECTRICAL �RAWINGS FOR MOUNTING HEIGHT. � WALLMOUNTEDDATARECEPTACLE.SEEELECTRICALDRAWINGS. �� FLUSHFLOORMOUNTEDDATARECEPTACLE.SEEELECTRICALDRAWINGS. �� FLOORiVJISTLOCK.SEEELECTRICAL�RAWINGS. � � � SECTIONAL WIREMOLD GANG BO%. SEE ELECTRICAL DRAWINGS. . �� WALL J-BOX. SEE ELECTRICAL DRAWINGS. �. LOOPVENT(SKINCARESTUDIO).SEEPWMBING�RAWINGS. ;�; WALLiWISTLOCK.SEEELECTRICALDRAWINGS. '�.S) TEMPERATURESENSOR.SEEMECHANICALDRAWWGS. '.:T�:'. THERMOSTAT.SEEMECHANICAL�RAWINGS. NOTES. 1.'EXTRA FLOOR RECEPTACLE (ALWAVS A�� 68 OUiLETS TO FILL IN GAPS FOR FUTURE USE) � POWER NOTES & SYMBOLS � NOT USED \� PROJECT LOCATION: CLAY TERRACE 14390 CLAY TERRACE BLVD SPACE D13 CARMEL, IN 46032 AREA: 4,129 SF SHEET TITLE: ARCHITECTURAL POWER PLAN PROJECT N0. 19122 STORE N0. 1326 SCALE: ASNOTED DATE: 11.04.2019 DRAWN BY: AE REVIEWE� BY: EB SHEET N0. A-102 (SHEET UPDATED 101011201AJ �