Loading...
HomeMy WebLinkAboutE400 - Electrical Lighting & Symbol Legendi TWICAL RECESSEO iROFFER IN HEAVY �l1iY i-BAR CEILING i i roa rixruaEs wEicHir�c �Ess TMnr� ss aouNos O MINIMUM TWO q12 GAUGE SLACK WIRE AT 45 DEGREES FROM OPPOSIiE FIXIDRE CORNERS 10 SiRUC1URE ABOVE. A11ACH �IRECiLV 10 Fl%il1RE WI1H 3 1URN 11GHi VRAP MINIMl1M. ATTACH TO SiRUCIDRE PER ACOl15TICAL CEILING ATTACHMENT DETAILS. SET WIRE SLIGHTLY SLACK, TO ALLOW FULL SEATING iNTO T-BAR. Ob POSIiIVELY AiiACH FI%iURE WiH MEiAL SCREW iHROUGH i-BAR INiO FIXIDRE AT OPPOSITE CORNERS. F F T W R R O 12 GAUGE Sl1PPORT WIRES WITH THREE IDRN TIGHT WRAP (WITHIN 1 1/7') MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECiLY ABOVE PER CEILING SUSPENSION DETAILS (4 PER FIXTURE). PEN�ANi HUNG FlXNRES O 9 GAUGE SUPPORT WIRES'MTH THREE TURN iIGHT WRAP (WITHIN 1 1/7') MINIMUM AT EACH END. ATTACH TO STRUCTURE DIRECILY ABOVE PER CEILING SUSPENSION �ETAILS. SURFACE CEILMG MOUNT SURFACE WALL MOUNT RECESSED CEILING MOUNT RECESSED WALL MOUNT 6ACKSTAGE ONLV BACKSTAGE ONLV SALES ONLV SALES ONLV �uu�� o ���� O ���� o LJW�� �1 EXIT SIGN MOUNTING DETAIL e�aoo N.T.S. NOTE: COORDINATE EXACT LOCATION OF RECEPTACLE & LIGHT WITH MECH. CONTR. SO AS NOT TO BLOCK ACCESS PANELS MAIN RUNNER rvcicn� RECEssEo FixTuaE T-BAR CEILING MEM9ER5 FIXTURE MOUNTING DETAIL NOT TO SCALE O MINIMUM 12 GAUGE SLACK WIRE AT 45 OEGREES FROM OPP09iE EpUIP. HOUSING CORNERS TO SiRUCIDRE ABOVE. ATTACH �IRECTLY TO FlXIDRE WIRi 3 IDRN TIGHT WRAP MINIMUM. ATTACH TO STRUCTURE PER ACOUSTICAL CEILING ATTACHMENT OEiAILS. SEi WIRE SLIGHiLY SLACK, i0 ALLOW FULL SEAiING INiO i-BAR. i-9AR CEILING MEMBERS -MAIN RUNNER RUNNER �19 Wil�Na1�GR131P1iH�D•]LIiJI _ , EQUIPMENT/FIXTURE MOUNTING Not to SCALE \A�'� i BURGLAR ALARM LEGEND �p coNrao�anNE�asiaEN KP USER KEVPAD � WALLMOTION � CEILINGMOTION ./I\_ —� REX MOTION QB GNSS BREAK � suRFncE000R coNrncr �� OVERHEAD DOOR CONTACT VIDEO LEGEND N�R EXACp NVR & POE � MONITORBCONTROLS � FlXE� ENTRVCAMERA OB -� FlXE� IP CAMERA � OUTDOORCAMERA ;O� IPPTZCAMERA � 3fi0CAMERA � WIRE RUN � COVERT WIRE ALIGN BOTTOM OF FIXTURE WITH TOP OF RTU �/ � 3/4" RIGID GALVANIZED STEEL CONDUIT STANCHION MOUNT LIGHT FIXTURE W ITH GLOBE AND GUARD AND 100W A-21 LAMP 3l4" RIGID GALVAWZED STEEL CONDUIT LEVITON #5299-I COMBINATION SINGLE POLE SWITCH AND GFI OUTLETIN WEATHERPROOF swircn eox ROUTE CONDUIT UP THRU OPENWG FlNISHED RW F SURFACE �� RTU LIGHT/RECEPTACLE DETAIL e�aoo N.T.S. (PROVIDED BY E.C.) ELECTRICAL DEVICE LEGEND ALL SYMBOLS DO NOT NECESSARILY IMouHnHc xct. ro cEwtExuHE uH�Ess otxEawisE rvotED APPLY SYMBOL � � � �wa �cFi �IG � CT � � �IG � � 0 � � � a fA fA3 EA4 � 0 �� � bp PC �� � �� � � � � C � -0 0 0 BB 0 HUB O � $v DESCRIPTION WIRE�JUNCTIONBOX WALL MOUMED JUNCTION BOX ouP�Ex aECEPrnc�E, s wiaE cao. ivPE, san �UPLE% RECEPTACLE,WEATHERPROOF,20A GROUND FAULT PROTECTED DUPLEXRECEPTAQE, 20A DUPLE%RECEPTACLE WITH ISOLATED GROIIND CONTROLLE� QUA�RAPLE% RECEPTACLE Qunoana�ex wnu aecearnc�e,zan �UPLE% RECEPTACLE, MOUNTE� ABOVE COUNTER (1) ISOLATED GROUND RECEPTACLE AND ONE DUPLEX RECEPTACLE AS A pUADRAPLEX WALL RECEPTACLE WALL MOUNTED NEMA L5�20R 20 AMP TWIST LOCK RECEPTAQE FLOOR MOUNTE� �UPLEX RECEPTAQE, 20A FLOOR MOUNTE�(RECESSE�)TWISTLOCKRECEPTACLE CEILING MOUNTE� �UPLEX RECEPTAQE, 20A PUSHBUTTONSTATION LOW VOLTAGE BUZZER TRANSFORMER 000aeuzzea TOGGLE SWITCH � SINGLE, 3�WAV 8 a�WAV OCCUPANCVSENSOR (TWO POLE WHERE NOTED) VACANCVSENSOR SWITCHED CIRCUIT uNswircneo ciacuir MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT DATA OIITLET � CATEGORY 6 PEOPLE COUNTER �EVICE SAFEN SWITCH MAGNETIC MOTOR STARTER COMBINATION STARTE WSAFETV SWITCH MOTOR OUTLET � 1 PHASE MOTOR OIITLET � 3 PHASE RRE ALARM HORNISTROBE SIGNAL �EVICE CEILMG MOl1NTED FIRE ALARM HORN/STROBE SIGNAL DEVICE FIRE ALARM STROBE SIGNAL �EVICE �UCT MID SYSTEM SMOKE �ETECTOR W/REMOTEINDICATORS FIRE ALARM PULL STATION SYSTEM SMOKE �ETECTOR FIRE ALARM BOOSTER BO% Kev ano HOL� UP BUTTON POWERPACK CE ILING MOUNTE� VACANCY SENSOR. WALL MOIINTE�, LOW VOLTAGE, MANUALON SWITCH. sEEoanwiNcs SEE DRAWINGS 18" 18" 18" 18' 18" 18" 68" 18" 20" 48" AS REQUIRE� 6" BELOW CEILING SP' � �i 48" 18" CEILING MID. AS REQUIRED AS REpl11RE� ns aEQuiaEo AS REQUIRED AS REpl11RE� 80" CEILING MTD. 80" ns aEQuiaEo 48" CEILING MID. ns aEQuiaEo 46" CEILING MID. AS REQUIRE� NorE iN HnNoicnvvEo naEns, rHE aECEvrnc�Es nNo rE�EVHONE ounErs sHnu eE mouNrEo nr is° aF F�, THE TOGGLE S WITCHES, THERMOSTATS AN� MANUAL MOTOR S�ARTERS SHALL 8E MOUME� AT 09" AF F. Tag Sym6ol Description ManufacturerandModelnum6er Note Lamp Wattage VolWge LWEARLEDSTRIPLIGHTOFVARVINGLENGTHS, XAL gZgp XALBA502.S,SUSPENDEDFROMCEILINGVIACABLE, BA52-�SUSPENSIONLENGTHTBD)-5-11W/FT-D2-3500K- SUSPENDEDVIACABLE,OPENCEILIN6, N/A 11W/FT lID � OPENCEILIN6�PENDANTMOUNT) CRI90-EMGHS-(LEN6THPERARCHITEQURAL (PENDANTMOUNT) DRAWINGS) LWEARLEDSTRIPLIGHTOFVARVINGLENGTHS, XALBA52-�SUSPENSIONLENGTH TBD)-5-11W/FT-D2- XALBA502.S,SUSPENDEDFROMCEILINGVIACABLE, 3500K-CRI90-EMGHS-(LEN6THPERARCHITEQURAL BZ'SP- OPENCEILIN6�PENDANTMOUNT)ONEMER6ENCV DRAWINGS)ONEMERGENCVCIRCUITWIREDTO SUSPENDEDVIACABLE,OPENCEILING, N/A 11W/FT 120 EM � CIRCUITWIREDTOINVERTER(FOR90MINUTE INVERTER(FOR90MINUTEEMER6ENCYBATTERYBACK �PENDANTMOUNT) EMER6EN6YBATTERYBACKUPVIAINVERTER) UPVIAINVERTER) LINEARLEDSTRIPLIGHTOFVARVINGLENGTHS, xA� 64.OP e XALBA504.O,SUSPENDEDFROMCEILIN6VIACABLE, BA54-(SUSPENSIONLENGTHTBDf-5-11W/FT-D2-4000K- SUSPENDEDVIACABLE,OPENCEILING, N/A 11W/FT 120 OPENCEILING�PENDANTMOUNT) CRISO-EMC-HS-�LEN6THPERARCHITEC�URAL (PENDANTMOUNT) DRAWINGS) LINEARLEDSTRIPLIGHT,4'INLENGTH, XAL gqpp. XALBA504.O,SUSPENDEDFROMCEILIN6VIACABLE, BA54-(SUSPENSIONLENGTHTBDf-5-11W/FT-D2-4000K- SUSPENDEDVIACABLE,OPENCEILIN6, N/A 11W/FT 120 EM � �PEN CEILING (PENDANT MOUNT) WITH 90 MINUTE CRISO-EMP-HS-�4') WITH 90 MINUTE EMER6ENCY (pENDANT MOUNT) EMERGENCYBATTERYBACKUPINTEGRALBATTERYPACK BATTERVBACKUPVIAINTEGRALBATTERVPACK XAL 64.OSM- o LINEARLEDSTRIPLI6HT,4'INLEN6TH, BA54-SM-511W/FT-D2-40K-CRI80-EMP-H8-4'WITH90 SURFACEMOUNTEDONDRVWALL EM XALBA504.O,SURFACEMOUNTEDONDRVWALLCEILING MINUTEEMER6EN6YBATTERYBACKUPVIAINTE6RAL �EILING N/A 11W/FT 120 BATTERV PACK K1B � �EILIN6 RECESSED LED LI6HT, 1 LAMP SQUARE, XAL RECESSED IN DRYWALL CEILING N/A 11W 120 XALKARO 100,eLACK N665-R-25-1-7-11W-7-2-7-1-M-0-8 INVERTER � INVERTERWITHEMERGENCYBACK-UPPOWER STACOUNISTARSCLI924-SJ50 FURNISHEDBYWESCO N/A N/A 120V RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�Ml1 � onrE: 01 /16/20 Tag Sym6ol Description ManufacturerandModelnum6er Note �mp Wattage VolWge BARTC0B55305-45-30-DIM-S-F-SWl-WH FURNISHEDANDINSTALLED SWATTS UNDER COUMER LED FIXTURE WITH 120V ROCKER N/A 120 UC �� SWITCH44-3/16"LONG,3000K,WHITEFINISH FURNISHEDANDINSTALLEDBVSEPHORAG.C. BVSEPHORAG.C. PERFOOT EXITRONIX COORDINATE WHITE OR BLACK E1F � EDGELIT EXIT 1 FACE, CEILING OR WALL MOUNT, BASED ON SURFACE COLOR, COLOR N/A 35 120 RECESSED OR SURFACE 590bW8-SR-RM-WH PERLOCALCODE EXITRONIX PROVIDE BLACK WHEN LOCATED ON E2F � ED6ELITEXIT2FACECEILIN60RWALLMOUNT, 5903-WB-SR-RM-WH B�CKSURFACEATSALES,COLOR N�A 35 120 � RECESSEDORSURFACE 2DARROWSASREQUIRED PERLOCALCODEFACEMUSTBE WHITE OR MIRROR 6D SALESAREALED60NDOLADISPLAYSEQION ARRAVCUSTOMLEDFIXTURE.NOTSUPPLIEDBVXAL, LEDLIGHTINGTOTALING86WATT5 N�A S6 lID SEPHORA DIREC� PURCHASE PER SELTION � SALESAREALEDPERIMETERWALLLINEARDISPLAY ARRAVCUSTOMLEDFIXTURE.NOTSUPPLIEDBVXAL, LEDLIGHTINGTOTALING43WATT5 W� FlXTURE SEPHORADIREQPURCHASE PERSEQION N�A 43 120 NOTES: SL -EM/SL -EM SECURITV LIGHT SECURITV LIGHT/EQUIPPE� WITH 6ATTERV 6ACKUP EMERGENCV LIGHT EQUIPPED WITH BATTERV BACK UP EMERGENCV LIGHT A. ALL FIXTURES TO 6E PROVI�E� BV SEPHORA LIGHTWG SUPPLIER UNLESS NOTE� OTHERWISE. B. FlXTURES TVPES "B4.OP"AND "B4.OSM" AS INDICATED WITH CODED NOTES #3AND#S ON THE SHEET E200, SHALL BE SUPPLIED WITH EMERGENCV BATTERV PACKS TO PROVIDE PROVIDE 90-MINUTES OF EMERGENCV OPERATION. C. ALL LIGHTS INSTALLED AT BLACK METAL CEILINGS ARE TO HAVE BLACK TRIM RINGS. I I I I i SEPHORA 525 MARKET STREET, 32ND FLOOR SAN FRANCISCO, CA 94105 Ber me er g Y � �11� M-Engineering ]50 Brooksedge Blvd. Westervllle, Ohlo 43081 phone: 614.839.4639 lar: 6f4.8392222 www meigineering.us.com STAMP ��_4-�9 .....G� A Mo..., �d�����STE'qF..n�O� � 0'.. i #i99oasa8 ; 1'•.. STATE Of J f. Q I DATE I ISSUEDESCRIPTION I BV I CHECK 10.01.19 I DESIGNDEVELOPMENT i1.0A]9 I ISSUE FOR PERMIT PROJECTLOCATION: CLAY TERRACE 14390 CLAY TERRACE BLVD SPACE D13 CARMEL, IN 46032 AREA: 4,129 SF SHEET TITLE: LIGHTING AND SYMBOLS LEGEND PROJECT N0. 19122 STORE N0. 1326 SCALE: AS NOTED DATE: 11.04.2019 DRAWN BY: NH REVIEWED BY: DFG SHEET N0. E-400 � �za�s(az��srza�e� �_