HomeMy WebLinkAboutE500 - Power Riser & Schedulesi MICARiA LABEL CONDUITANDWIRINGFORHVAC I TYPICAL FOR ALL PANELS I EpUIPMENT.SEEELECTRICALEpUIPMENT T CONNECTIONSCHE�ULEONTHISSHEET. I PANEL "B" 2" MiN. 120/208V, 36, 4W 12"WIREWAV GENERALCONTRACTOR � FURNISHED & INSTALLED. TO SALES AREA "EM" NEW (4)#3/OTHWN &(1)il6THWN GROUND IN NEW 2" CONDUIT TO BE EXTENDED TO SEPHORA IFS LOCATION. FlELD VERIFV EXACT LOCATIONS AND REpUIREMENTS PRIOR TO BIDS. � (APPRO%IMATELV 60'. FIELD VERIFV EXACT DISTANCE) LEASE LINE LANDLORD � TENANT SPACE SPACE PULL BOX BV I f TENANTS G.C. NEW METERANDMETERSOCKETFORSEPHORA ELECTRICAL SERVICE. VERIFV EXACT RE�UIREMENTS WITH LANDLORDAND UTILITV COMPANY PRIOR TO BID3 � NEW 200A3 POLE CIRCl11T BREAKER IN � LAN�LOR�SWITCHGEARFORSEPHORA O ELECTRICAL SERVICE VERIFV EXACT REOUIREMENTS WITH LANDLORD PRIOR TO BIDS.� �I EXISTMG2]]I480V,3m,4WLANDLORD /p0Al3P SWITCHBOARDLOCATEDINLANDLORD ELECTRICAL ROOM "Di". FlELD VERIFV I `O I EXACTCONDITIONSAND I I REQl11REMENTS PRIOR TO BIDS. � I I ,I� � �� �� �� PANEL .A. O i LIGHTING RXTURES LIGHTING I 4 MIN.� INVERTER Fn o (2) SETS OF #18/2 THWN. PANEL g LVa LVb LVc LVd LVe FLOOR LOW VOLTAGE OVERRI�E SWITCH EXTEN� CON�UIT AND WIREAS REOUIRED. BOARD "Ti" 45 KVA TRANSFORMER 480V DELTA PRIMARV TO 120I208V WVE I SECONDARV� I TRANSFORMERGROUNDTO /� I GROUNDBUSINIFSSWITCHGEAR(SN� NEW(2)2"CON�UITSSTUBBE� II N2GRDTOBLDG /�GRD.BUS� � \� INTO SPACE FOR �� STEEL PER N.E.0 � — �� TELECOMMUNICATIONS. NOTE:SEEFLOORPLAN(E-100)FORPROPERORIENTATIONOFIFSPANELS POWER RISER DIAGRAM POWER RISER GENERAL NOTES'. NTS A HVAC CIRCUIT BREAKERS SHALL BE "HACR" TVPE WHERE REOUIRED BV EOUIPMENT NAMEPLATE PER N.E.C.. q�� NEW TERMINATIONS SHALL BE ]5° C RATED B TENANT'SELECTRICALCONTRACTORSHALLFIELDVERIFVEXACTAJ.C.RATINGOFLANDLORD'SDISTRIBUTION pOWERRISERCODEDNOTES: Ep WPMENT, Fl1RNI5H AND INSTALL TENANTS SVSTEM TO MATCH. iO IFS SWITCHBOAR� PROVI�E� BV WESCQ PURCHASE� BV OWNER. E.C. SHALL RECENE, C ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL E�UIPMENT TO 310% BETWEEN INSPECT, INSTALL AND MAKE FlNAL CONNECTIONS PER MANUFACTURER'S INSTRUCTIONS. PHASES'. NB BIC, NC REGARDLESS OF QRCUITING INDICATEq EXCEPT FOR PANEL "A", WHICH SHALL BE FOR MFORMATION CONTACT WESCO @ 1-800-41]-]543. QRCUITED AS INDICATED. OLIGHTING CONTROL PANEL UTILIZING SOLENOID OPERATED'SMART' BREAKERS. E.C. SHALL D PROPER CLEARANCE M115T BE MAINTAINED ABOl1T ELECTRICAL EpWPMENT PER N.E.C. FIELD VERIFV EXACT WIRE BRANCH CIRCWTS E%ACTLV AS INDICATED IN THE PANEL SCHEDl1LE. PROGRAMMMG MOUNTWGSPACEAVAILABLEINELECTRICALROOMIAREAPRIORTOINSTALLATIONOFELECTRICAL OFCONTROLPANELBVOWNER. EpUIPMENT. O3 MOMENTARVCONTACTSWITCHESFOROVERRIDEOFALLLIGHTINGZONESMOUNTEDON E ELECTRICALCONTRACTORSHALLMAKEALLFlNALELECTRICALCONNECTIONSFORACOMPLETEELECTRICAL FACEOFTCSLIGHTINGCONTROLPANEL. DISTRIBUTION SVSTEM. O4 E.C.TOINSTALLAMOMENTARVCONTACTSWITCHFORTHEOVERRIDEOFALLLIGHTMG F TENANT'SNAMEANDSPACENl1MBER5HALLBEAPPLIEDTODISCONNECTSWITCHATSWITCHGEARWITH ZONES.PROVIDEWIREANDMAKEALLFINALCONNECTIONS. BLACK PLASTIC LAMENT WITH WHITE LETTERS. OS CABLED BV IFS SWITCHGEAR MANUFACTURER PER N.E.G GUIDELINES. G TENANTB ELECTRICAL CONTRACTOR SHALL VERIFV EXISTING CONDITIONS PRIOR TO BID. ELECTRICAL EQUIPMENT CONNECTION SCHEDULE MOCP GROl1NDEDANDl1NGROl1NDED CONNECTION UNIT VOLTAGE FLA MCA �pOLE CONDUCTORS CONDUIT SWITCHDISCONNECTATUNIT CIRCUIT NOTES RTU -1 480V, 3 PHASE 36.80 A 49.00 A 50/3 (3) k8 THW N&(1) k10 GND 3/4" 60A, 3-POLE, NONFUSED, WP H-2/4/6 NEW UNIT RTU -2 480V, 3 PHASE 36.80 A 49.00 A 50/3 (3) #8 THW N&(1) #10 GND 3/4" 60A, 3-POLE, NONFUSED, WP H-]/9/11 NEW UMT RT113 480V,3PHASE 1630A 2200A 25/3 (3)#10THWN&(1)#10GND 3/4" 30A,3-POLE,NONFUSED,WP H-8/10H2 NEWl1NIT NOTE: VERIFV EXACT OVER Cl1RRENT PROTECTION/DISCONNECT REpl11REMENTS (PER N.E.C. #440) WITH Epl11PMENT MANl1FACTl1RER NAMEPLATE DATA 11PON RECEIPT AT JOB SITE. CONTACT ENGMEERWITHANVDISCREPANCIES. ELECTRICALCONTRACTORTOMAKEALLFlNALELECTRICALPOWERCONNECTIONS. No[es BreakerOptions: ' All circui[ breakers [o be 20-Amp, 1-Pole unless o[herwise no[ed. AS Powetlink AS Breaker " All Phases to be balanced to withln 10% using ACNaI Load Totali LO Handle lock-on device N.E.G Connected Totals: Ph A 384]6 kVA ST Shun[ Trip Type N.EC. Connec[ed To[als'. Ph.B 38]21 kVA AUX Auxiliary Con[ac[s E ExlstlngClrcul[roremaln N.EL.Connec[edTo[als:Ph.0 39.183 kVA PA HandlePadlockA[tachmen[ IG Isole[etl Grountl Ciraui[ Total 116.386 kVA GFCI Ground FaW[Clrcul[In[errup[er HACR Heatlng, NC & Refrigeratlon Connec[etl Loatl: 140.0 amps SF Subfeed NEC Demand Feeder Load: 1532 amps qFCI Arc Fault Clrwit Interrupter Panel Wiring Schedule (3-Phase) Penelboertl "B" Voltega 200Y/120 PM1ese 3 OylionslNolas PenelTypa IFSSVJRCHGEAR OCPO 100AMCB. Wre 0 NEMAType 1 Moun4ng IFS Buss 225A AICReOng 65,000 No[es BreakerOp[ions'. " All circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. AS Powedlnk AS Breaker " All Phases [o be balanced [o wi[hin 10 % using Ac[ual Load To[als. LO Handle lock-on device N.E.C. Connec[ed To[als: Ph A 5.628 kVA ST Shunt Trip Type N.E.G Connected Totals: Ph.B 5.922 kVA AU% Auxiliary Con[ac[s N.EC. Connec[ed To[als'. Ph.0 5580 kVA PA Handle Padlock A[[achmen[ To[al 1].130 kVA GFCI GroundFaWtCircuitlnterrupter E Existing Circuitto remain HACR Hea[ing, NC8 Rebigere[ion IG Isolated Ground Circuit Connected Load: 4].5 amps SF Subfeed RELEASED FOR CONSTRACTION "E� °e'"a"° Fee°e' `°a°' ".9 a'"°s "F°' "'° Fa°"�"°°"'"`e"°°`e' Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �I `��¢m�' lamn�Ml1 � onrE: 01 /16/20 I LIGHTING ZONES ZONE A: STORE FRONT coNsisrs oF�. SHOW WINDOW LIGHTING SHOW WINDOW RECEPTACLES EXTERIOR LIGHTMG SIGNS FRAGRHNCELAUNCH ZONE B: SALES LIGHTING CONSISTS OF: 2/3 OF WALL �ISPLAV GONDOLAS DISPLAV LIGHTING 'NOTE TO TCS BASVS-ENSURE LIGHTMG ZONE IS MANUAL ON ONLV' ZONEC'. STAFFLIGHTING CONSISTS OF�. 1/3 OF WALL �ISPLAV 'NOTE TO TCS BASVS-ENSURE LIGHTING ZONE IS MANUAL ON ONLV' ZONED'. il2OFGENERALLIGHTING CONSISTS OF: 1/2 OF GENERAL LIGHT W G "NOTE TO TCS BASVS-ENSURE LIGHTING ZONE IS MANUAL ON ONLV' ZONEE: V20FGENERALLIGHTWG CONSISTS OF: 1/2 OF GENERAL LIGHTING 'NOTE TO TCS BASVS-ENSURE LIGHTING ZONE IS MANUAL ON ONLV' No[es BreakerOp[ions: ' All circui[ breakers [o be 20-Amp, 1-Pole unless o[herwise no[ed. AS Powedlnk AS Breaker " All Phases to be balanced to withln 10 % using AcNal Load Totals. LO Hantlle lock-on tlevice N.E.C. Connec[ed Totals: Ph.A ].935 kVA ST Shun[TripType N.EC.ConnectedTotals:Ph.B �.892 kVA AUX AuxiliaryContacts N.E.C. Connec[ed To[als'. Ph.0 8.690 kVA PA Handle PadlockA[[achmen[ Total 24.51] kVA GFCI GroundFaN[Circui[In[errup[er E Existing Circui[ ro remein HACR Hea[ing, AIC & Re(ngeretlon IG Isola[ed Ground Circui[ Connected Load: 68.1 amps SF Subfeed NEC Demand Feeder Load'. ]9.6 amps qFCI Arc FaN[ Circui[ In[errup[er SECTION NUMBER SECTION WIDTH SHIPPING SECTIONS i FLOOR PLAN NO BOTTOM CONOUIT ENTRV THIS SECTION PANEL H q OMC9 0 Pao-is /� M/0 XFMR T-1 00000 o e � 2 3 �36.00�20.00--'—� �36.00y29.00 900 ELEVATION DRAWING NTS GENERALNOTES: 1 INFORMATION REGARDMG THIS EpUIPMENT MAV BE OBTAINED FROM WESCO AT 1-800-4114543. 2 WHEREAPPLICABLE,ALLPANELBOARDANDTRANSFORMERSWILLBE FACTORV INSTALLED AND CABLED W ITH NEC S IZED CONDUCTORS. SEE THE ONELINE DIAGRAM FOR DETAILS. THE CONTRACTOR W ILL BE REpl11RED TO MAKE ALL FINAL TERMINATION FOR PROPER TORpUE. 3 ALL INTEGRATED PANELBOARD WILL BE RECE55 MOUNTED IN THE SWITCHBOARD TO ALLOW FOR TOTAL FRONT ACCESS. 4 WHEREFACTORVINSTALLEDCABLINGOCCl1R5BETWEENSWITCHBOARD SHIPPMG SPLITS, THE G.C. WILL BE RESPONSBLE FOR FIELD TERMINATION OF THE CABLES. SEE ELEVATION VIEW DRAWINGS FOR SHIPPING SPLIT INFORMATION. 5 EACHSWITCHBOARDSHIPPINGSPLITWILLBEPALLETIZEDANDSHIPPEDIN AN ENCLOSED SEMI-TRAILER. THE G.C. SHALL ARRANGE FOR A FORK TRl1CK TO UNLOADAND SET THE EpUIPMENT IN PLACE. A24-HOUR NOTICE WILL BE GIVEN PRIOR TO DELIVERV. 6 THEELECTRICALSWITCHGEARSHALLBEANCHOREDTOTHESUPPORTING SLAB-ON-GRADE USING (2) 5/8" DIAMETER HILTI "KWIK BOLT 3" EXPANSIONS ANCHORS WITH 2314" EMBEDMENT AT THE E%TREME (4) CORNERS OF THE UNIT. THE FOUR HOL� �OWN BRACKETS WILL BE PROVI�E� BV THE SWITCHGEAR MANUFACTURER AND SHIPPED WITH THE SWITCHGEAR. i CONTROLS RESPONSIBILITIES: ELECTRICAL CONTRACTOR TO COOR�INATE LIGHTING CONTROL WORK WITH TCS BASYS. CONTACTJORDAN POWERS- JPOWERS@TCSBASVSLOM 1-80P288-9383 x9429. ELECTRIC LOAD SUMMARY (TRANSFORMER) 208V/120V LOADS NEC. NEC N£C. NEC. 21PTION CONNECTE� OEMANO OEMANO OEMANO kVq NOTES FqGTOF kVq irvc�corvnrvuous) »oe� �i� izs zi33a ( LIGHT OEMANO ALLOWANCE 1�I 0.000 WINOOWOEMANOALLOWANCE 13� 0000 aunNce onoo lal �.00 onoo =rnaes a.�2o Is� 0.�20 as o000 �s� o000 SYSTEM 0.000 I6� 0.000 SYSTEM-NONCOINGOENT 0000 I�I 00 0000 �aicwnTeaHenTea snoo �.o snoo LLANEOUS 16.060 - 1.0 16.060 01 fi0] 05910 N.E.C.oEM.KVAX1000 - MINIMUMFEEOERAMPERAGE SYS. VOLTAGE X 1 ]32 ass�axi000 = �zza nmvs 200 X 1.]32 GBOV/2]]V SVSTEM NEc. NEc N.Ec. NEc. SCRIPTION CONNECTEO OEMANO OEMANO OEMANO kVA NOTES FACTOR kVA ;H1iNc�coNnNuous� ».os� I�I �.�s xiasa ACNLIGHTOEMANOALLOWANCE - 121 - 0.000 owwiNoowoemnNonuownNce - 131 - o.aoo -naaunmce o.000 Ia1 too o.000 CEPTACLES 0 ]20 I5� p]20 ITORS OD00 �6� OD00 ACSYSTEM ]4.]39 I6� ]6.639 ACSYSTEM-NONCOINCI�ENT ���� I]� pp pppp ecTwcwnTeaHenTea s.000 i.o s.000 SCEWNEOUS 16060 - 10 16060 TOTAL 116306 TOTAL 12]353 N.EC.�EM.KVAX1000 = MINIMIIMFEE�ERAMPERAGE sys. w�ince x i.�s2 12]353X1000 = 1532 AMPS 400 X 1 ]32 no suMMnav NOTEs: [i] aowEaFncToaisn�aEnoviNc�uoEoiNucHnNc�ono. [2] i5�VA2FTOFLMEVOLTA6ETRACKfSUMLOWVOLTA6EXFRMS-CONNECTEOLOAO [3] 2oovnaF-nclun�coNNecleo�ono [Q] KITAGGLIANCE�EMAN�FACTORGERNEC220�56 [5] oo<ioKw=iooi,aemnitiitio=5ni [6] �q6%OFTHELARGESTMOTORORCOMPRESSORINSYSTEMAPPLIFDONONEUNR. ��� EOl11GMENTWILLNOT9EOGERATINGWHILESYSTEMISATMA%IMIIM�EMAN�. ELECTRICAL RESPONSIBILITY SCHEDULE FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIG THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT E%ISTING FIELD CONDITIONS. THIS CONTRACT SHALL INC W DE ALL LABOR AND MATERIALS NECESSARV FOR FIELD MODIFICATIONS DUE TO EXISTMG CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGMEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFlCATIONS MADE BV THE ARCHITECT, ENGMEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTEDAT CONTRACTORSCOST. BIDDMG CONTRACTORS SHALL HAVE A WORKMG KNOWLEDGE OF LOCAL CO�ES AN� OR�INANCES AN� SHALL INCLU�E IN THEIR BI�S THE COSTS FORALL WORK INSTALLED IN STRICTACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFlCATIONS NOT W ITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR O W NER OF ANV APPARENT DISCREPANCIES BETWEEN GOVERNMG CODES AND DESIGN INTENT. FURNISHED BY INSTALLED BY '� z ¢ ¢ v� ~ ~ w o � Q o � Q U p K N U � K N N O ¢ O ¢ �j 0 2 W �j p 2 W � J � w F J � w F I \ W g v� O W g v� O ¢ Z MAIN OVERCURRENT DEVICE M � � 2 FIEL� VERIFV EXISTMG LAN�LOR�'S ELECTRIC ROOM O CONDITIONS PRIORTO BID PANEL BOARD CONDUIT TO SPACE • � O RELD VERIFV EXISTING CONDITIONS PRIORTO BID PANELBOARD FEEDERS TO SPACE • � O RELD VERIFV EXISTING CONDITIONS PRIORTO BID METER REpUIREMENTS • � O REL� VERIFY EXISTING CONDITIONS PRIORTO BID TENANT IFS PANELBOARD AND � � O TRANSFORMER LIGHT FlXTURES AND LAMPS • • INVERTER • • FURNISHEDBVWESCO CURRENT LIMITMG PANEL • OUTLETSANDSWITCHES • • GENERALCONDUIT&WIRING • • TELEPHONECONDUITW/PULLWIRE • � O FIEL�vERIFVEXISTMG CONDITIONS PRIORTO BID TELEPHONE CABLING • • Oj TELEPHONEE�UIPMENT • • LOWVOLTAGEDATACONDUIT • • LOW VOLTAGEDATACABLMG • • Oi COOR�INATE W REL� VIDEO/TVCONDUIT • • FUTURE VIDEO/NCABLING • • FUTURE TEMPORARV UTILITV CHARGES • • TENANT FIREALARM SVSTEM � OFlELD VERIFV EXACT REOUIREMENTS PRIOR TO BID FLOOR BOXES • • LIGHTINGCONTROLS • • DISCONNECTSWITCHESANDMOTOR � � STARTERS AHII LIGHTIRECEPTACLE • RTU LIGHT/RECEPTACLE • • MOTORIZED / ZONE DAMPER POW ER AND TRANSFORMERS � RESPONSIBILITV SCHEDULE CODED NOTES Ot ALLFINALCONNECTIONSTOEQWPMENTBVOTHERS. O2 SEEPOWERRISERDIAGRAMFORADDITIONALMFORMATION. O3 VERIFV EXACT REQUIREMENTS WITH LANDLORD AND AHJ PRIOR TO BID. I I I i SEPHORA 525 MARKET STREET, 32ND FLOOR SAN FRANCISCO, CA 94105 Ber me er g Y �11� M-Engineering ]50 Brooksedge Blvd. Westervllle, Ohlo 43081 phone: 614.839.4639 lar: 6f4.8392222 www meigineering.us.com STAMP ��A_1y ..•"Gti A. M�-.,,, � �� :��STE,qF�O� 0.2F' O . � #19900608 ; Q DATE ISSUEDESCRIPTION BV CHECK 10.01.19 DESIGNDEVELOPMENT i1.0A]9 ISSUE FOR PERMIT PROJECTLOCATION: CLAY TERRACE 14390 CLAY TERRACE BLVD SPACE D13 CARMEL, IN 46032 AREA: 4,129 SF SHEET TITLE: POWER RISER AND SCHEDULES PROJECT N0. 19122 STORE N0. 1326 SCALE: AS NOTED DATE: 11.04.2019 DRAWN BY: NH REVIEWED BY: DFG SHEET N0. E-500 � �za�s�azr�srza�e7 �_ Panel Wiring Schedule (3-Phase) va�emoam '�n'� vonega wevnw vn�e a opuo�sirvoo� va�eirype iFsswircH�ena ocao isonmce. wire a NEMAType 1 MounOng IF9 9uss P25A AICRa[Tg 65,000 Panel Wiring Schedule (3-Phase) ae�eiooem 'H" vorcaqe aeonxn anwsa s opro�siNoeas PenelType IFSSWRCHGEAR OCPO 200AM.C.B. Wre 4 NEMATyye 1 Mounling IFS Buss 400A AICReIing 65,000