Loading...
HomeMy WebLinkAboutMDC A400 BUILDING SECTIONS���. ♦ T.O. STEEL ELEV.110'_1 1/4" — FLOOR ELEVA R-12 RIGID INSULATION � \ DARK BRONZE METAL COPING R-18 RIGID INSULATION CUSTOM CAST STONE PAN ELS, 2" TH I C K 1" AIR SPACE — BUILDING WRAP — 5/8" EXTERIOR SHEATHING — BRONZE INFlLL PANEL REFER TO SHEET A600 � FLASHING AS NECESSARY � OHC GRADE 1 IPE, TEX-GAP 1X4 PRORLE, INSTALL PER MANUFACTURER'S REQ. � BUILDING WRAP � 5/8" EXTERIOR SHEATHING � R19 BATT INSULATION IN 6" METAL STUD FRAMING AT 16" O.C. CANOPY WITH EXPOSED CHANNEL STEEL, REFER TO 5104 & 5201 FOR DEfAILS OHC GRADE 1 IPE, TEX-GAP 1X4 PRORLE, INSTALL PER MANUFACTURER'S REQ. FLASHING AS NECESSARY STOREFRONT WINDOW REFER TO SHEEf A600 � OWALL SECTION uz.-„o. FLASHING AS NECESSARY DARK BRONZE MEfAL � COPING R-18 RIGID INSULATION CUSTOM CAST STONE PAN ELS, 2" TH I C K 1"AIR SPACE � BUILDING WRAP � 5/8" EXTERIOR SHEATHING — BRONZE INFILL WSULATED PANEL — REFER TO SHEEf A600 FLASHING AS NECESSARY � OHC GRADE 1 IPE, TEX-GAP � 1X4 PRORLE, INSTALL PER MANUFACTURER'S REQ. BUILDING WRAP � 5/8" EXTERIOR SHEATHING � R19 BATT INSULATION IN � 6" METAL STUD FRAMING AT 16" O.C. CANOPY WITH EXPOSED CHANNEL STEEL, REFER TO 5104 & 5201 FOR DEfAILS OHC GRADE 1 IPE, TEX-GAP 1X4 PRORLE, INSTALL PER MANUFACTURER'S REQ. FLASHING AS NECESSARY STOREFRONT WINDOW REFER TO SHEET A600 \ O � FLASHING AS NECESSARYI I �� � OWALL SECTION i�2��_„��� T.O.PARAPEf ELEV. 12p-2' T.O. STEEL ELEV.110'1 1/4" _ FLOOR ELEVATION ELEV. 100'_0" R-12 RIGID INSULATION OWALL SECTION I/2��_�� ��� 4 A201 C�W INJULHIIVN �ARK BRONZE METAL OPING /OOD BLOCKING T.O.PARAPEf ELEV.11q-2" HELSEA IRONSPOT BRICK AIR SPACE FLASHING AS NECESSARY 1ARDIE LAP SIDING, NSTALL ALTERNATING 12" AND 4" EXPOSURES, 'AINT'PT-X' BUILDIIJG WRAP 5/8" EXTERIOR SHEATHING 219 BATT INSULATION IN S" METAL STUD FRAMING 4T 16" O.C. �FLOOR ELEVATION ELEV. 100'_0" NG AS NECESSARY DARK BRONZE MEL" COPING CUSTOM CAST STC PANELS, 2" THICK 1" AIR SPf BUILDING Wf 5/8" EXTERIOR SHEATHI R-19 BATT INSULATI IN 6" MEfAL STUD FRAMING AT 16" C RASHING AS NECESSA OWALL SECTION I/2��_�� ��� T.O.PARAPET ELEV.125-2" RIGID INSULATION ,�FLOOR ELEVATION ELEV. 100' 0" R-12 RIGID INSULATION C'"= �E z ,� � - �" o E a 0 0 `o_' �Ua °N� Ca =vo c u�,a,�a Oa i�a Zm �M3 °� g o 3 a 3 `o � a No. ' 0600116 NTE OF . � o v � m' n v v o �`3 0 m o o u I..L W � Z � � W° � U` N � Z° U V ^ O , ^ O v I O W � 0 � � � O Z� � Q� � QO � U � N I..L ^ W < 9/l0/l9 Pcrmi�Sc� Job Nurnber- RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �I `��¢m�' lamn�Ml1 � DATE: O1IZ1IZO OKEY PLAN � NOSCALE NORiH o�a�,n„e Na,.,a�. BUILDING SECiIONS o,�:�.��„e rv�,.,�e�- A400 ( � 1 DVILVIIVV JCI.IIVIV �J I/8��_�� ��� OBUILDING SECTION I/8��_�� 0��